Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38837387

RESUMEN

BACKGROUND: Comprehensive, patient-specific models are essential to study calcium deposition and mobilization during dialysis. We aim to develop tools to support clinical prescriptions with a more accurate approach for the prediction of calcium mobilization while also considering major electrolytes and catabolites. METHODS: We modified a multi-solute model predicting patient-specific dialysis response by incorporating a calcium buffer to represent bone exchanges. Data from four centers, involving 127 patients with six sessions each, were utilized. For each patient, three sessions were allocated for model training (ID123), while the remaining sessions were for validation (PRED456). The normalized root mean square error (nRMSE%) was used to evaluate both descriptive and predictive accuracy. Correlations between initial data and calcium exchanges were also assessed. RESULTS: The overall nRMSE% for ID123 was 3.92%. For PRED456, it was 3.46% (ranging from a minimum of 1.17% for [Na+] to a maximum of 6.62% for [urea]). The median nRMSE% for plasma calcium varied between 1.13 and 8.32 for SHD sessions, depending on whether Ca_dialysis fluid (Cad) was ≥ or <1.50 mmol/L, respectively. For HDF sessions, the range was between 2.90 and 5.89. A significant and moderate correlation was found between overall calcium removal and the buffer balance. The most robust correlation observed was between the amount of calcium administered via post-dilution fluid and the overall calcium removal in the dialysis filter. CONCLUSIONS: Identical therapy settings do not uniformly affect calcium mobilization, and our approach offers insight into calcium distribution across body compartments. This understanding will enhance clinical prescription practices.

2.
Artif Organs ; 47(7): 1133-1150, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37042396

RESUMEN

BACKGROUND: Infants with single-ventricle (SV) physiology undergo the 3-stage Fontan surgery. Norwood patients, who have completed the first stage, face the highest interstage mortality. The Berlin Heart EXCOR (BH), a pediatric pulsatile ventricular assist device, has shown promise in supporting these patients. However, clinical questions regarding device configurations prevent optimal support. METHODS: We developed a combined idealized mechanics-lumped parameter model of a Norwood patient and simulated two additional patient-specific cases: pulmonary hypertension (PH) and post-operative treatment with milrinone. We quantified the effects of BH support across different device volumes, rates, and inflow connections on patient hemodynamics and BH performance. RESULTS: Increasing device volume and rate increased cardiac output, but with unsubstantial changes in specific arterial oxygen content. We identified distinct SV-BH interactions that may impact patient myocardial health and contribute to poor clinical outcomes. Our results suggested BH settings for patients with PH and for patients treated post-operatively with milrinone. CONCLUSIONS: We present a computational model to characterize and quantify patient hemodynamics and BH support for infants with Norwood physiology. Our results emphasized that oxygen delivery does not increase with BH rate or volume, which may not meet patient needs and contribute to suboptimal clinical outcomes. Our findings demonstrated that an atrial BH may provide optimal cardiac loading for patients with diastolic dysfunction. Meanwhile, a ventricular BH decreased active stress in the myocardium and countered the effects of milrinone. Patients with PH showed greater sensitivity to device volume. In this work, we demonstrate the adaptability of our model to analyze BH support across varied clinical situations.


Asunto(s)
Corazón Auxiliar , Milrinona , Lactante , Humanos , Niño , Milrinona/uso terapéutico , Resultado del Tratamiento , Hemodinámica , Simulación por Computador , Oxígeno , Corazón Auxiliar/efectos adversos
3.
Artif Organs ; 47(8): 1326-1341, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36995361

RESUMEN

BACKGROUND: Parametric multipool kinetic models were used to describe the intradialytic trends of electrolytes, breakdown products, and body fluids volumes during hemodialysis. Therapy customization can be achieved by the identification of parameters, allowing patient-specific modulation of mass and fluid balance across dialyzer, capillary, and cell membranes. This study wants to evaluate the possibility to use this approach to predict the patient's intradialytic response. METHODS: 6 sessions of 68 patients (DialysIS© project) were considered. Data from the first three sessions were used to train the model, identifying the patient-specific parameters, that, together with the treatment settings and the patient's data at the session start, could be used for predicting the patient's specific time course of solutes and fluids along the sessions. Na+ , K+ , Cl- , Ca2+ , HCO3 - , and urea plasmatic concentrations and hematic volume deviations from clinical data were evaluated. RESULTS: nRMSE predictive error is on average equal to 4.76% when describing the training sessions, and only increases by 0.97 percentage points on average in independent sessions of the same patient. CONCLUSIONS: The proposed predictive approach represents a first step in the development of tools to support the clinician in tailoring the patient's prescription.


Asunto(s)
Modelación Específica para el Paciente , Diálisis Renal , Humanos , Equilibrio Hidroelectrolítico , Sodio
4.
Artif Organs ; 44(9): 976-986, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32348583

RESUMEN

Total artificial heart (TAH) represents the only valid alternative to heart transplantation, whose number is continuously increasing in recent years. The TAH used in this work, is a biventricular pulsatile, electrically powered, hydraulically actuated flow pump with all components embodied in a single device. One of the major issues for TAHs is the washout capability of the device, strictly correlated with the presence of blood stagnation sites. The aim of this work was to develop a numerical methodology to study the washout coupled with the fluid dynamics evaluation of a total artificial heart under nominal working conditions. The first part of this study focussed on the CT scan analysis of the hybrid membrane kinematics during TAH operation, which was replicated with a fluid-structure interaction simulation in the second part. The difference in percentage between the in vitro and in silico flow rates and stroke volume is 9.7% and 6.3%, respectively. An injection of contrast blood was simulated, and a good washout performance was observed and quantified with the volume fraction of the contrast blood still in the ventricle. The left chamber of the device showed a superior washout performance, with a contrast volume still inside the device after four washout cycles of 6.2%, with the right chamber showing 15%.


Asunto(s)
Corazón Artificial , Modelos Cardiovasculares , Diseño de Prótesis , Simulación por Computador , Humanos , Flujo Sanguíneo Regional/fisiología , Volumen Sistólico/fisiología
5.
Microvasc Res ; 122: 101-110, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30448400

RESUMEN

Fluid homeostasis is required for life. Processes involved in fluid balance are strongly related to exchanges at the microvascular level. Computational models have been presented in the literature to analyze the microvascular-interstitial interactions. As far as we know, none of those models consider a physiological description for the lymphatic drainage-interstitial pressure relation. We develop a computational model that consists of a network of straight cylindrical vessels and an isotropic porous media with a uniformly distributed sink term acting as the lymphatic system. In order to describe the lymphatic flow rate, a non-linear function of the interstitial pressure is defined, based on literature data on the lymphatic system. The proposed model of lymphatic drainage is compared to a linear one, as is typically used in computational models. To evaluate the response of the model, the two are compared with reference to both physiological and pathological conditions. Differences in the local fluid dynamic description have been observed using the non-linear model. In particular, the distribution of interstitial pressure is heterogeneous in all the cases analyzed. The resulting averaged values of the interstitial pressure are also different, and they agree with literature data when using the non-linear model. This work highlights the key role of lymphatic drainage and its modeling when studying the fluid balance in microcirculation for both to physiological and pathological conditions, e.g. uremia.


Asunto(s)
Simulación por Computador , Linfa/fisiología , Vasos Linfáticos/fisiología , Modelos Anatómicos , Análisis Numérico Asistido por Computador , Equilibrio Hidroelectrolítico , Análisis de Elementos Finitos , Humanos , Modelos Lineales , Linfa/metabolismo , Vasos Linfáticos/anatomía & histología , Vasos Linfáticos/metabolismo , Dinámicas no Lineales , Porosidad , Presión , Uremia/metabolismo , Uremia/fisiopatología
6.
Soft Matter ; 10(32): 6077-86, 2014 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-25005426

RESUMEN

It is well known that block copolymers with cylindrical morphology show alignment with shear, resulting in anisotropic mechanical properties. Here we show that well-ordered bi-directional orientation can be achieved in such materials by slow injection moulding. This results in a microstructure, and anisotropic mechanical properties, similar to many natural tissues, making this method attractive for engineering prosthetic fibrous tissues. An application of particular interest to us is prosthetic polymeric heart valve leaflets, mimicking the shape, microstructure and hence performance of the native valve. Anisotropic layers have been observed for cylinder-forming block copolymers centrally injected into thin circular discs. The skin layers exhibit orientation parallel to the flow direction, whilst the core layer shows perpendicularly oriented domains; the balance of skin to core layers can be controlled by processing parameters such as temperature and injection rate. Heart valve leaflets with a similar layered structure have been prepared by injection moulding. Numerical modelling demonstrates that such complex orientation can be explained and predicted by the balance of shear and extensional flow.


Asunto(s)
Polímeros/química , Ingeniería de Tejidos , Animales , Anisotropía , Válvula Aórtica , Dispersión del Ángulo Pequeño , Porcinos , Difracción de Rayos X
7.
J Prosthet Dent ; 112(5): 1201-11, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24993377

RESUMEN

STATEMENT OF PROBLEM: Metal ceramic systems are used for the majority of dental crowns and fixed dental prostheses. However, problems with porcelain bonding are encountered when titanium is used as the substrate. PURPOSE: The purpose of this study was to evaluate the effect of intermediate calcium oxide-stabilized zirconia (ZrO2-CaO) coatings deposited by cold thermal spraying on the titanium-porcelain bonding in dental restorations. MATERIAL AND METHODS: Two different types of ZrO2-CaO coatings obtained by oxyacetylene cold thermal spraying deposition were applied on commercially pure titanium bars before adding the porcelain layer. Type 1 was obtained by directly spraying the ZrO2-CaO powder on the titanium substrate. Type 2 was obtained by spraying a bond coat of nickel-aluminum-molybdenum alloy before spraying the ZrO2-CaO powder. Three-point bend tests according to International Organization of Standardization 9693-1:2012 were carried out to evaluate the debonding strength for the ZrO2-CaO-coated specimens (types 1 and 2) in comparison with a noncoated group (control), which received a traditional bonder-based adhesive technique. The results were compared with ANOVA, followed by the Student-Newman-Keuls test for pairwise comparisons. Scanning electron microscopy and energy dispersion spectroscopy were used to examine the interfacial properties and the failure mode of each group. RESULTS: Mean (±standard deviation) debonding strength values for type 1 coating (25.97 ±2.53 MPa) and control (23.51 ±2.94 MPa) were near the acceptable lower limit of 25 MPa indicated by the International Organization of Standardization 9693-1:2012 and were not significantly different (Student-Newman-Keuls test, P>.05). Type 2 coating produced an improved titanium-porcelain bonding (debonding strength=39.47 ±4.12 MPa), significantly higher than both type 1 (Student-Newman-Keuls test, P<.05) and control (Student-Newman-Keuls test, P<.05). Scanning electron microscopy-energy dispersion spectroscopy analysis confirmed these findings, which revealed a predominant cohesive failure mode for type 2. CONCLUSIONS: An intermediate coating layer of ZrO2-CaO plus a substrate of bonding nickel-aluminum-molybdenum alloy applied by oxyacetylene cold thermal spraying deposition provided an improved titanium-porcelain bond.


Asunto(s)
Compuestos de Calcio/química , Materiales Biocompatibles Revestidos/química , Recubrimiento Dental Adhesivo , Materiales Dentales/química , Porcelana Dental/química , Óxidos/química , Titanio/química , Circonio/química , Alquinos/química , Aluminio/química , Aleaciones Dentales/química , Análisis del Estrés Dental/instrumentación , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Molibdeno/química , Níquel/química , Docilidad , Espectrometría por Rayos X , Estrés Mecánico , Propiedades de Superficie
8.
Appl Ergon ; 117: 104223, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38219376

RESUMEN

Postpartum haemorrhage (PPH) is an obstetric emergency causing nearly one-quarter of maternal deaths worldwide, 99% of these in low-resource settings (LRSs). Uterine balloon tamponade (UBT) devices are a non-surgical treatment to stop PPH. In LRSs, low-cost versions of UBT devices are based on the condom balloon tamponade (CBT) technique, but their effectiveness is limited. This paper discusses the experimental study to assess the usability and performance of a medical device, BAMBI, designed as an alternative to current CBT devices. The testing phase involved medical and non-medical personnel and was focused on testing BAMBI's usability and effectiveness compared to a standard CBT solution. We collected measures of the execution time and the procedure outcome. Different training procedures were also compared. Results show a significant preference for the BAMBI device. Besides, medical and non-medical subjects reached comparable outcomes. This aspect is highly relevant in LRSs where the availability of medical personnel could be limited.


Asunto(s)
Muerte Materna , Hemorragia Posparto , Taponamiento Uterino con Balón , Embarazo , Femenino , Humanos , Hemorragia Posparto/prevención & control , Condones , Taponamiento Uterino con Balón/métodos , Personal de Salud
9.
Sci Rep ; 14(1): 10004, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693193

RESUMEN

The 3.1 target of the Sustainable Development Goals of the United Nations aims to reduce the global maternal mortality ratio to less than 70 maternal deaths per 100,000 live births by 2030. The last updates on this target show a significant stagnation in the data, thus reducing the chance of meeting it. What makes this negative result even more serious is that these maternal deaths could be avoided through prevention and the wider use of pharmacological strategies and devices to stop postpartum haemorrhage (PPH). PPH is the leading obstetric cause of maternal mortality in low- and middle-income countries (LMICs). Despite low-cost devices based on the uterine balloon tamponade (UBT) technique are already available, they are not safe enough to guarantee the complete stop of the bleeding. When effective, they are too expensive, especially for LMICs. To address this issue, this study presents the design, mechanical characterisation and technology assessment performed to validate a novel low-cost UBT kit, particularly a novel component, i.e., the connector, which guarantees the kit's effectiveness and represents the main novelty. Results proved the device's effectiveness in stopping PPH in a simulated scenario. Moreover, economic and manufacturing evaluations demonstrated its potential to be adopted in LMICs.


Asunto(s)
Países en Desarrollo , Mortalidad Materna , Hemorragia Posparto , Taponamiento Uterino con Balón , Humanos , Femenino , Taponamiento Uterino con Balón/economía , Taponamiento Uterino con Balón/métodos , Taponamiento Uterino con Balón/instrumentación , Hemorragia Posparto/terapia , Hemorragia Posparto/mortalidad , Hemorragia Posparto/prevención & control , Hemorragia Posparto/economía , Embarazo
10.
Biomedicines ; 12(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38255197

RESUMEN

Pancreatic surgery is extremely challenging and demands an extended learning curve to be executed with a low incidence of post-operative complications. The soft consistency of the human pancreas poses a primary challenge for pancreatic surgeons. This study aimed to analyze the preliminary mechanical characteristics of the human pancreas to develop a realistic synthetic phantom for surgical simulations in the near future. Pancreatic specimens, comprehensive of the pancreatic parenchyma and main pancreatic duct, were collected during pancreatic resections and analyzed through nano-bio-indentation (BioindenterTM UNHT3 Bio, Anton Paar GmbH, Graz, Austria) to measure the elastic modulus. Comparisons were made between slow and fast loading rates, immediate and post-freezing analyses, and multipoint indentations. The results demonstrated that a slow loading rate (30 µN/min), immediate analysis, and multipoint measurements are crucial for obtaining accurate values of the elastic modulus of the human pancreas (1.40 ± 0.47 kPa). In particular, the study revealed that analysis after freezing could impact the outcomes of the indentation. Moreover, the study suggested that both the pancreatic parenchyma and the main pancreatic duct should be analyzed to achieve a more precise and comprehensive definition of the. mechanical features of the pancreas. These preliminary findings represent the initial steps toward defining the consistency and mechanical characteristics of human pancreatic tissue with the goal of creating a realistic synthetic phantom.

11.
Int J Med Inform ; 172: 105002, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36739758

RESUMEN

BACKGROUND: Given the impact of bioengineering and medical informatics technologies in health care, the design and implementation of education programs able to combine medical curricula with a proper teaching on engineering and informatics is now of paramount importance. In Italy, this goal has to fit in with the existing higher education system, which is structured into Bachelor programs and Master programs. Medicine and Surgery programs, instead, are designed as a six-year single-cycle Degree Program in Medicine and Surgery which comprises both class attendance and hospital internship and training. This program allows students to become Medical Doctors (MD). The different organization of this University program makes it not easy to introduce further contents, namely hard science courses, in the educational program. Notwithstanding this, we present here some recent innovative programs aimed at widening MD curriculum by including biomedical engineering and informatics subjects. In particular, we will introduce three of them. Two are joint-degree programs, the first between Humanitas University and Politecnico di Milano (MEDTEC School), and the second between University of Calabria and University Magna Graecia of Catanzaro (Medicina e Chirurgia TD). The Third one is a Professional Master coupled with an MD degree, based on a joint program among Pavia University, Pisa University, the Institute of Advanced studies in Pavia and the Scuola Superiore S. Anna in Pisa (MEET). CONTRIBUTION: The paper provides a description of the fundamental design principles of the three above mentioned programs, and explores some aspects of the teaching modules, highlighting their positive aspects. In particular, we show how the three different programs allow students to enrich their knowledge by studying engineering subjects and innovative methods and technologies, as well as their applications to patient care. CONCLUSIONS: The MEDTEC program is the first degree program at Italian and international scale which integrates medical and engineering subjects. In the following years, other programs were issued in Italy, defining similar education programs to couple a degree in medicine education with bioengineering and medical informatics, among which Medicina e Chirurgia TD and MEET. We believe the experiences described here in this paper represent the possibility of bridging the gap between medical and technological competencies.


Asunto(s)
Ingeniería Biomédica , Informática Médica , Humanos , Ingeniería Biomédica/educación , Curriculum , Bioingeniería , Italia
12.
Biomedicines ; 11(4)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37189673

RESUMEN

The choice of the most appropriate suture threads for pancreatic anastomoses may play an important role in reducing the incidence of post-operative pancreatic fistula (POPF). The literature on this topic is still not conclusive. The aim of this study was to analyze the mechanical characteristics of suture materials to find the best suture threads for pancreatic anastomoses. A single-axial electromagnetic actuation machine was used to obtain the stress-deformation relationship curves and to measure both the ultimate tensile strength (UTS) and the Young's modulus at the 0-3% deformation range (E0-3) of four different suture materials (Poliglecaprone 25, Polydioxanone, Polyglactin 910, and Polypropylene) at baseline and after incubation in saline solution, bile, and pancreatic juice for 1, 3, and 7 days. Polydioxanone and Polypropylene showed stable values of UTS and E0-3 in all conditions. Polyglactin 910 presented significant UTS and E0-3 variations between different time intervals in all types of liquids analyzed. Poliglecaprone 25 lost half of its strength in all biological liquids analyzed but maintained low E0-3 values, which could reduce the risk of lacerations of soft tissues. These results suggest that Polydioxanone and Poliglecaprone 25 could be the best suture materials to use for pancreatic anastomoses. In vivo experiments will be organized to obtain further confirmations of this in vitro evidence.

13.
Int J Numer Method Biomed Eng ; 39(11): e3752, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37455669

RESUMEN

The vascular microenvironment is the scale at which microvascular transport, interstitial tissue properties and cell metabolism interact. The vascular microenvironment has been widely studied by means of quantitative approaches, including multi-physics mathematical models as it is a central system for the pathophysiology of many diseases, such as cancer. The microvascular architecture is a key factor for fluid balance and mass transfer in the vascular microenvironment, together with the physical parameters characterizing the vascular wall and the interstitial tissue. The scientific literature of this field has witnessed a long debate about which factor of this multifaceted system is the most relevant. The purpose of this work is to combine the interpretative power of an advanced multi-physics model of the vascular microenvironment with state of the art and robust sensitivity analysis methods, in order to determine the factors that most significantly impact quantities of interest, related in particular to cancer treatment. We are particularly interested in comparing the factors related to the microvascular architecture with the ones affecting the physics of microvascular transport. Ultimately, this work will provide further insight into how the vascular microenvironment affects cancer therapies, such as chemotherapy, radiotherapy or immunotherapy.


Asunto(s)
Neoplasias , Humanos , Neoplasias/terapia , Modelos Teóricos , Física , Microambiente Tumoral
14.
Bioeng Transl Med ; 8(5): e10557, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37693050

RESUMEN

Three-dimensional (3D) imaging techniques (e.g., confocal microscopy) are commonly used to visualize in vitro models, especially microvasculature on-a-chip. Conversely, 3D analysis is not the standard method to extract quantitative information from those models. We developed the µVES algorithm to analyze vascularized in vitro models leveraging 3D data. It computes morphological parameters (geometry, diameter, length, tortuosity, eccentricity) and intravascular flow velocity. µVES application to microfluidic vascularized in vitro models shows that they successfully replicate functional features of the microvasculature in vivo in terms of intravascular fluid flow velocity. However, wall shear stress is lower compared to in vivo references. The morphological analysis also highlights the model's physiological similarities (vessel length and tortuosity) and shortcomings (vessel radius and surface-over-volume ratio). The addition of the third dimension in our analysis produced significant differences in the metrics assessed compared to 2D estimations. It enabled the computation of new indices, such as vessel eccentricity. These µVES capabilities can find application in analyses of different in vitro vascular models, as well as in vivo and ex vivo microvasculature.

15.
Int J Med Inform ; 173: 104975, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36905746

RESUMEN

Intradialytic hypotension (IDH) is a common complication in patients undergoing hemodialysis therapy. No consensus on the definition of intradialytic hypotension has been established so far. As a result, coherent and consistent evaluation of its effects and causes is difficult. Some studies have highlighted existing correlations between certain definitions of IDH and the risk of mortality for the patients. This work is mainly focused on these definitions. Our aim is to understand if different IDH definitions, all correlated with increased mortality risk, catch the same onset mechanisms or dynamics. To check whether the dynamics captured by these definitions are similar, we performed analyses of the incidence, of the IDH event onset timing, and checked whether there were similarities between the definitions in those aspects. We evaluated how these definitions overlap with each other and we evaluated which common factors could allow identifying patients at risk of IDH at the beginning of a dialysis session. The definitions of IDH we analyzed through statistical and machine learning approaches, showed a variable incidence on the HD sessions and had different onset time. We found that the set of parameters relevant for the prediction of the IDH was not always the same for the definitions considered. However, it can be observed that some predictors, such as the presence of comorbidities such as diabetes or heart disease, and a low pre-dialysis diastolic blood pressure, have shown universal relevance in highlighting an increased risk of IDH during the treatment. Among those parameters, the one that showed a major importance is the diabetes status of the patients. Diabetes or heart disease presence are permanent risk factors pointing out an increased IDH risk during the treatments, while, pre-dialysis diastolic blood pressure is instead a parameter that can change at every session and should be used to evaluate the specific risk to develop IDH for each session. The identified parameters could be used in the future to train more complex prediction models.


Asunto(s)
Cardiopatías , Hipotensión , Fallo Renal Crónico , Humanos , Fallo Renal Crónico/epidemiología , Fallo Renal Crónico/terapia , Fallo Renal Crónico/complicaciones , Diálisis Renal/efectos adversos , Hipotensión/diagnóstico , Hipotensión/epidemiología , Hipotensión/etiología , Presión Sanguínea
16.
Front Physiol ; 14: 1070474, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37008002

RESUMEN

Introduction: Developing techniques for the tagless isolation of homogeneous cell populations in physiological-like conditions is of great interest in medical research. A particular case is Gravitational Field-Flow Fractionation (GrFFF), which can be run avoiding cell fixation, and that was already used to separate viable cells. Cell dimensions have a key role in this process. However, their dimensions under physiological-like conditions are not easily known since the most diffused measurement techniques are performed on fixed cells, and the fixation used to preserve tissues can alter the cell size. This work aims to obtain and compare cell size data under physiological-like conditions and in the presence of a fixative. Methods: We developed a new protocol that allows the analysis of blood cells in different conditions. Then, we applied it to obtain a dataset of human cord blood cell dimensions from 32 subjects, comparing two tubes with anticoagulants (EDTA and Citrate) and two tubes with different preservatives (CellRescue and CellSave). We analyzed a total of 2071 cells by using confocal microscopy via bio-imaging to assess dimensions (cellular and nuclear) and morphology. Results: Cell diameter measured does not differ when using the different anticoagulants, except for the increase reported for monocyte in the presence of citrate. Instead, cell dimensions differ when comparing anticoagulants and cell preservative tubes, with a few exceptions. Cells characterized by high cytoplasm content show a reduction in their size, while morphology appears always preserved. In a subgroup of cells, 3D reconstruction was performed. Cell and nucleus volumes were estimated using different methods (specific 3D tool or reconstruction from 2D projection). Discussion: We found that some cell types benefit from a complete 3D analysis because they contain non-spherical structures (mainly for cells characterized by poly-lobated nucleus). Overall, we showed the effect of the preservatives mixture on cell dimensions. Such an effect must be considered when dealing with problems highly dependent on cell size, such as GrFFF. Additionally, such information is crucial in computational models increasingly being employed to simulate biological events.

17.
Digit Health ; 9: 20552076231218858, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38107981

RESUMEN

Objective: The aim of the study was to develop an app to improve patients' adherence to therapy for osteoporosis and to test its usability. Methods: In Phase I, the app functions needed to improve medication adherence were identified through a focus group with six patients with osteoporosis and a joint interview with two bone specialists. The app prototype was then developed (Phase II) and refined after its feasibility testing (Phase III) for 13-25 days by eight patients. Finally, the app underwent usability testing (Phase IV) for 6 months by nine other patients. The mHealth App Usability Questionnaire (MAUQ) was used to collect the assessment of the app by the 17 patients. Results: The final version of the app provided information on osteoporosis, allowed patients to contact the bone specialist for an additional consultation, and generated a reminder for taking medications accompanied by feedback on adherence. The assessment of the app was positive but evaluations differed between the feasibility and usability testing, with the former displaying a significantly (p ≤ .05) better assessment across all MAUQ items. Conclusions: In this study, we tested an app for improving adherence to medical therapies in patients with osteoporosis. The usability testing revealed a lower "patient-centered" performance of the app as compared to that observed during the feasibility phase. Future developments of the study include increasing the testing cohort and adding a technical support during the usability testing.

18.
J Appl Biomater Biomech ; 9(2): 109-17, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22065388

RESUMEN

Over the last twenty years major advancements have taken place in the design of medical devices and personalized therapies. They have paralleled the impressive evolution of three-dimensional, non invasive, medical imaging techniques and have been continuously fuelled by increasing computing power and the emergence of novel and sophisticated software tools. This paper aims to showcase a number of major contributions to the advancements of modeling of surgical and interventional procedures and to the design of life support systems. The selected examples will span from pediatric cardiac surgery procedures to valve and ventricle repair techniques, from stent design and endovascular procedures to life support systems and innovative ventilation techniques.


Asunto(s)
Ingeniería Biomédica/métodos , Ingeniería Biomédica/tendencias , Sistemas de Manutención de la Vida/instrumentación , Modelos Cardiovasculares , Adolescente , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/tendencias , Niño , Preescolar , Humanos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/tendencias , Lactante , Programas Informáticos/tendencias
19.
Ann Biomed Eng ; 49(12): 3356-3373, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34184146

RESUMEN

We address a mathematical model for oxygen transfer in the microcirculation. The model includes blood flow and hematocrit transport coupled with the interstitial flow, oxygen transport in the blood and the tissue, including capillary-tissue exchange effects. Moreover, the model is suited to handle arbitrarily complex vascular geometries. The purpose of this study is the validation of the model with respect to classical solutions and the further demonstration of its adequacy to describe the heterogeneity of oxygenation in the tissue microenvironment. Finally, we discuss the importance of these effects in the treatment of cancer using radiotherapy.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Microcirculación/fisiología , Modelos Cardiovasculares , Consumo de Oxígeno/fisiología , Simulación por Computador , Hematócrito , Humanos
20.
Cancers (Basel) ; 13(5)2021 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-33803333

RESUMEN

Ionizing radiation (IR) is used in radiotherapy as a treatment to destroy cancer. Such treatment also affects other tissues, resulting in the so-called normal tissue complications. Endothelial cells (ECs) composing the microvasculature have essential roles in the microenvironment's homeostasis (ME). Thus, detrimental effects induced by irradiation on ECs can influence both the tumor and healthy tissue. In-vitro models can be advantageous to study these phenomena. In this systematic review, we analyzed in-vitro models of ECs subjected to IR. We highlighted the critical issues involved in the production, irradiation, and analysis of such radiobiological in-vitro models to study microvascular endothelial cells damage. For each step, we analyzed common methodologies and critical points required to obtain a reliable model. We identified the generation of a 3D environment for model production and the inclusion of heterogeneous cell populations for a reliable ME recapitulation. Additionally, we highlighted how essential information on the irradiation scheme, crucial to correlate better observed in vitro effects to the clinical scenario, are often neglected in the analyzed studies, limiting the translation of achieved results.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA