Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38289867

RESUMEN

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Asunto(s)
Taquicardia Ventricular , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Ganglio Estrellado , Volumen Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Fibrilación Ventricular/etiología , Función Ventricular Izquierda , Persona de Mediana Edad
2.
J Cardiovasc Electrophysiol ; 35(2): 290-300, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38098308

RESUMEN

INTRODUCTION: Mitral valve prolapse (MVP) is a common clinical condition in the general population. A subgroup of patients with MVP may experience ventricular arrhythmias and sudden cardiac death ("arrhythmic mitral valve prolapse" [AMVP]) but how to stratify arrhythmic risk is still unclear. Our meta-analysis aims to identify predictive factors for arrhythmic risk in patients with MVP. METHODS: We systematically searched Medline, Cochrane, Journals@Ovid, Scopus electronic databases for studies published up to December 28, 2022 and comparing AMVP and nonarrhythmic mitral valve prolapse (NAMVP) for what concerns history, electrocardiographic, echocardiographic and cardiac magnetic resonance features. The effect size was estimated using a random-effect model as odds ratio (OR) and mean difference (MD). RESULTS: A total of 10 studies enrolling 1715 patients were included. Late gadolinium enhancement (LGE) (OR: 16.67; p = .005), T-wave inversion (TWI) (OR: 2.63; p < .0001), bileaflet MVP (OR: 1.92; p < .0001) and mitral anulus disjunction (MAD) (OR: 2.60; p < .0001) were more represented among patients with AMVP than in NAMVP. Patients with AMVP were shown to have longer anterior mitral leaflet (AML) (MD: 2.63 mm; p < .0001), posterior mitral leaflet (MD: 2.96 mm; p < .0001), thicker AML (MD: 0.49 mm; p < .0001), longer MAD length (MD: 1.24 mm; p < .0001) and higher amount of LGE (MD: 1.41%; p < .0001) than NAMVP. AMVP showed increased mechanical dispersion (MD: 8.04 ms; 95% confidence interval: 5.13-10.96; p < .0001) compared with NAMVP. CONCLUSIONS: Our meta-analysis proved that LGE, TWI, bileaflet MVP, and MAD are predictive factors for arrhythmic risk in MVP patients.


Asunto(s)
Leucemia Mieloide Aguda , Prolapso de la Válvula Mitral , Humanos , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico por imagen , Medios de Contraste , Gadolinio , Válvula Mitral/diagnóstico por imagen , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/patología , Leucemia Mieloide Aguda/patología
3.
Artículo en Ro | MEDLINE | ID: mdl-38583089

RESUMEN

A 16-year-old female with dual-chamber pacemaker (Medtronic Azure XT DR), due to symptomatic third-degree congenital atrioventricular (AV) block, presented to our ambulatory with dizziness and presyncopal episodes preceded by prodromes, occurring over the last few months. The device was programmed in DDD mode with an upper rate of 150 bpm. A head-up Tilt Test (HUTT) revealed the unexpected emergence of 2:1 electronic AV block at a sinus rate of 130 bpm.

4.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493490

RESUMEN

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Asunto(s)
Miocarditis , Sarcoidosis , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas/etiología , Arritmias Cardíacas/complicaciones , Medios de Contraste , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/epidemiología , Gadolinio , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética/efectos adversos , Miocarditis/complicaciones , Pronóstico , Medición de Riesgo , Factores de Riesgo , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico por imagen , Volumen Sistólico , Función Ventricular Izquierda
5.
Eur J Clin Invest ; 53(9): e14013, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37144525

RESUMEN

BACKGROUND: QT interval varies with the heart rate (HR), so a correction in QT calculation is needed (QTc). Atrial fibrillation (AF) is associated with elevated HR and beat-to-beat variation. AIM: To find best correlation between QTc in atrial fibrillation (AF) versus restored sinus rhytm (SR) after electrical cardioversion (ECV) (primary end point) and to determine which correction formula and method are the best to determine QTc in AF (secondary end point). METHODS: During a 3-month period, we considered patients who underwent 12-lead ECG recording and received an AF diagnosis with indication for ECV. Exclusion criteria were as follows: QRS duration >120 ms, therapy with QT-prolonging drugs, a rate control strategy and a nonelectrical cardioversion. The QT interval was corrected using Bazzett's, Framingham, Fridericia and Hodges formulas during the last ECG during AF and the first one immediately after ECV. QTc mean was calculated as mQTc (average of 10 QTc calculated beat per beat) and as QTcM (QTc calculated from the average of 10 raw QT and RR for each beat). RESULTS: Fifty consecutive patients were enrolled in the study. Bazett's formula showed a significant change in mean QTc value between the two rhythms (421.5 ± 33.9 vs. 446.1 ± 31.9; p < 0.001 for mQTc and 420.9 ± 34.1 vs. 441.8 ± 30.9; p = 0.003 for QTcM). On the contrary, in patients with SR, QTc assessed by the Framingham, Fridericia, and Hodges formulas was similar to that in AF. Furthermore, good correlations between mQTc and QTcM are present for each formula, even in AF or SR. CONCLUSIONS: During AF, Bazzett's formula, seems to be the most imprecise in QTc estimation.


Asunto(s)
Fibrilación Atrial , Humanos , Frecuencia Cardíaca/fisiología , Electrocardiografía/métodos , Cardioversión Eléctrica
6.
Pacing Clin Electrophysiol ; 46(12): 1652-1661, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37864437

RESUMEN

BACKGROUND: Conduction system pacing (CSP) and atrioventricular junction ablation (AVJA) improve outcomes in patients with symptomatic, refractory atrial fibrillation (AF). Superior approach (SA) from the pocket via axillary or subclavian vein has been proposed as an alternative to the conventional femoral venous access (FA) to perform AVJA. OBJECTIVE: To assess the feasibility and safety of SA for AVJA performed simultaneously with CSP, and to compare this approach with FA. METHODS: A prospective, observational study, enrolling consecutive patients with symptomatic, refractory AF undergoing simultaneous CSP and AVJA. RESULTS: A total of 107 patients were enrolled: in 50, AVJA was primarily attempted with SA, in 69 from FA. AVJA with SA was successful in 38 patients (76.0%), while in 12 patients, a subsequent FA was required. AVJA from FA was successful in 68 patients (98.5%), while in one patient, a left-sided approach via femoral artery was required. Compared with FA, SA was associated with a significantly longer duration of ablation (238.0 ± 218.2 vs. 161.9 ± 181.9 s; p = .035), a significantly shorter procedure time (28.1 ± 19.8 vs. 19.8 ± 16.8 min; p = .018), an earlier ambulation (2.7 ± 3.2 vs. 19.8 ± 0.1 h; p < .001), and an earlier discharge from procedure completion (24.0 ± 2.7 vs. 27.1 ± 5.1 h; p < .001). After a median follow-up of 12 months, the rate of complications was similar in the two groups (2.0% in SA, 4.3% in FA; p = .483). CONCLUSION: Simultaneous CSP and AVJA with SA is feasible, with a safety profile similar to FA. Compared to FA, this approach reduces the procedure times and allows earlier ambulation and discharge.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Nodo Atrioventricular/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter/métodos , Fascículo Atrioventricular
7.
Pacing Clin Electrophysiol ; 46(5): 432-439, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37036831

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) reduces heart failure (HF) hospitalization and all-cause mortality in HF patients with left bundle branch block (LBBB). Biventricular pacing (BVP) is the gold standard for achieving CRT, but about 30%-40% of patients do not respond to BVP-CRT. Recent studies showed that left bundle branch pacing (LBBP) provided remarkable results in CRT. Therefore, we conducted a meta-analysis aiming to compare LBBP-CRT versus BVP-CRT in HF patients. METHODS: We systematically searched the electronic databases for studies published from inception to December 29, 2022 and focusing on LBBP-CRT versus BVP-CRT in HF patients. The primary endpoint was HF hospitalization. The effect size was estimated using a random-effect model as Risk Ratio (RR) and mean difference (MD). RESULTS: Ten studies enrolling 1063 patients met the inclusion criteria. Compared to BVP-CRT, LBBP-CRT led to significant reduction in HF hospitalization [7.9% vs.14.5%; RR: 0.60 (95%CI: 0.39-0.93); p = .02], QRSd [MD: 30.26 ms (95%CI: 26.68-33.84); p < .00001] and pacing threshold [MD: -0.60 (95%CI: -0.71 to -0.48); p < .00001] at follow up. Furthermore, LBBP-CRT improved LVEF [MD: 5.78% (95%CI: 4.78-6.77); p < .00001], the rate of responder [88.5% vs.72.5%; RR: 1.19 (95%CI: 1.07-1.32); p = .002] and super-responder [60.8% vs. 36.5%; RR: 1.56 (95%CI: 1.27-1.91); p < .0001] patients and the NYHA class [MD: -0.42 (95%CI: -0.71 to -0.14); p < .00001] compared to BVP-CRT. CONCLUSION: In HF patients, LBBP-CRT was superior to BVP-CRT in reducing HF hospitalization. Further significant benefits occurred within the LBBP-CRT group in terms of QRSd, LVEF, pacing thresholds, NYHA class and the rate of responder and super-responder patients.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Tabique Interventricular , Humanos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Sistema de Conducción Cardíaco , Bloqueo de Rama , Fascículo Atrioventricular , Electrocardiografía/métodos
8.
Pacing Clin Electrophysiol ; 46(11): 1430-1439, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37812165

RESUMEN

BACKGROUND: High-power-short-duration (HPSD) radiofrequency (RF) ablation is a viable alternative to low-power-long-duration (LPLD) RF for pulmonary vein isolation (PVI). Nevertheless, trials showed conflicting results regarding atrial fibrillation (AF) recurrences and few data concerning complications. Therefore, we conducted a meta-analysis of randomized trials comparing HPSD versus LPLD. METHODS: We systematically searched the electronic databases for studies published from inception to March 31, 2023 focusing on HPSD versus LPLD. The study endpoints were AF recurrence, procedural times and overall complications. RESULTS: Five studies enrolling 424 patients met the inclusion criteria (mean age 61.1 years; 54.3% paroxysmal AF; mean LVEF 58.2%). Compared to LPLD, HPSD showed a significantly lower AF recurrence rate [16.3% vs. 30,1%; RR: 0.54 (95% CI: 0.38-0.79); p = 0.001] at a mean 10.9 months follow-up. Moreover, HPSD led to a significant reduction in total procedural time [MD: -26.25 min (95%CI: -42.89 to -9.61); p = 0.002], PVI time [MD: -26.44 min (95%CI: -38.32 to -14.55); p < 0.0001], RF application time [MD: -8.69 min (95%CI: -11.37 to -6.01); p < 0.00001] and RF lesion number [MD: -7.60 (95%CI: -10.15 to -5.05); p < 0.00001]. No difference was found in either right [80.4% vs. 78.2%; RR: 1.04 (95% CI: 0.81-1.32); p = 0.77] or left [92.3% vs. 90.2%; RR: 1.02 (95% CI: 0.94-1.11); p = 0.58] first-pass isolation and overall complications [6% vs. 3.7%; RR: 1.45 (95%CI: 0.53-3.99); p = 0.47] between groups. CONCLUSION: In our metanalysis of randomized trials, HPSD ablation appeared to be associated to a significantly improved freedom from AF and shorter procedures, without increasing the risk of complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37378419

RESUMEN

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Asunto(s)
Vena Axilar , Incisión Venosa , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Vena Axilar/cirugía , Incisión Venosa/métodos , Vena Subclavia , Punciones/métodos , Corazón
10.
Echocardiography ; 40(3): 217-226, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36748264

RESUMEN

BACKGROUND: Early diagnosis of Coronary Artery Disease (CAD) plays a key role to prevent adverse cardiac events such as myocardial infarction and Left Ventricular (LV) dysfunction. Myocardial Work (MW) indices derived from echocardiographic speckle tracking data in combination with non-invasive blood pressure recordings seems promising to predict CAD even in the absence of impairments of standard echocardiographic parameters. Our aim was to compare the diagnostic accuracy of MW indices to predict CAD and to assess intra- and inter-observer variability of MW through a meta-analysis. METHODS: Electronic databases were searched for observational studies evaluating the MW indices diagnostic accuracy for predicting CAD and intra- and inter-observer variability of MW indices. Pooled sensitivity, specificity, and Summary Receiver Operating Characteristic (SROC) curves were assessed. RESULTS: Five studies enrolling 501 patients met inclusion criteria. Global Constructive Work (GCW) had the best pooled sensitivity (89%) followed by GLS (84%), Global Work Index (GWI) (82%), Global Work Efficiency (GWE) (80%), and Global Wasted Work (GWW) (75%). GWE had the best pooled specificity (78%) followed by GWI (75%), GCW (70%), GLS (68%), and GWW (61%). GCW had the best accuracy according to SROC curves, with an area under the curve of 0.86 compared to 0.84 for GWI, 0.83 for GWE, 0.79 for GLS, and 0.74 for GWW. All MW indices had an excellent intra- and inter-observer variability. CONCLUSIONS: GCW is the best MW index proving best diagnostic accuracy in the prediction of CAD with an excellent reproducibility.


Asunto(s)
Enfermedad de la Arteria Coronaria , Disfunción Ventricular Izquierda , Humanos , Reproducibilidad de los Resultados , Ecocardiografía , Miocardio , Función Ventricular Izquierda , Volumen Sistólico
11.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-36991870

RESUMEN

A diagnosis of Brugada syndrome (BrS) is based on the presence of a type 1 electrocardiogram (ECG) pattern, either spontaneously or after a Sodium Channel Blocker Provocation Test (SCBPT). Several ECG criteria have been evaluated as predictors of a positive SCBPT, such as the ß-angle, the α-angle, the duration of the base of the triangle at 5 mm from the r'-wave (DBT- 5 mm), the duration of the base of the triangle at the isoelectric line (DBT- iso), and the triangle base/height ratio. The aim of our study was to test all previously proposed ECG criteria in a large cohort study and to evaluate an r'-wave algorithm for predicting a BrS diagnosis after an SCBPT. We enrolled all patients who consecutively underwent SCBPT using flecainide from January 2010 to December 2015 in the test cohort and from January 2016 to December 2021 in the validation cohort. We included the ECG criteria with the best diagnostic accuracy in relation to the test cohort in the development of the r'-wave algorithm (ß-angle, α-angle, DBT- 5 mm, and DBT- iso.) Of the total of 395 patients enrolled, 72.4% were male and the average age was 44.7 ± 13.5 years. Following the SCBPTs, 24.1% of patients (n = 95) were positive and 75.9% (n = 300) were negative. ROC analysis of the validation cohort showed that the AUC of the r'-wave algorithm (AUC: 0.92; CI 0.85-0.99) was significantly better than the AUC of the ß-angle (AUC: 0.82; 95% CI 0.71-0.92), the α-angle (AUC: 0.77; 95% CI 0.66-0.90), the DBT- 5 mm (AUC: 0.75; 95% CI 0.64-0.87), the DBT- iso (AUC: 0.79; 95% CI 0.67-0.91), and the triangle base/height (AUC: 0.61; 95% CI 0.48-0.75) (p < 0.001), making it the best predictor of a BrS diagnosis after an SCBPT. The r'-wave algorithm with a cut-off value of ≥2 showed a sensitivity of 90% and a specificity of 83%. In our study, the r'-wave algorithm was proved to have the best diagnostic accuracy, compared with single electrocardiographic criteria, in predicting the diagnosis of BrS after provocative testing with flecainide.


Asunto(s)
Síndrome de Brugada , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Síndrome de Brugada/diagnóstico , Bloqueadores de los Canales de Sodio/farmacología , Bloqueadores de los Canales de Sodio/uso terapéutico , Flecainida , Estudios de Cohortes , Electrocardiografía , Algoritmos
12.
J Cardiovasc Electrophysiol ; 33(8): 1874-1879, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35695789

RESUMEN

BACKGROUND: Fever is a potential side effect of the Covid-19 vaccination. Patients with Brugada syndrome (BrS) have an increased risk of life-threatening arrhythmias when experiencing fever. Prompt treatment with antipyretic drugs is suggested in these patients. AIM OF THE STUDY: To evaluate the incidence and management of fever within 48 h from Covid-19 vaccination among BrS patients. METHODS: One hundred sixty-three consecutive patients were enrolled in a prospective registry involving five European hospitals with a dedicated inherited disease ambulatory. RESULTS: The mean age was 50 ± 14 years and 121 (75%) patients were male. Prevalence of Brugada electrocardiogram (ECG) pattern type-1, -2, and -3 was 32%, 44%, and 24%, respectively. Twenty-eight (17%) patients had an implantable cardioverter-defibrillator (ICD). Fever occurred in 32 (19%) BrS patients after 16 ± 10 h from vaccination, with a peak of body temperature of 37.9° ± 0.5°. Patients with fever were younger (39 ± 13 vs. 48 ± 13 years, p = .04). No additional differences in terms of sex and cardiovascular risk factors were found between patients with fever and not. Twenty-seven (84%) out of 32 patients experienced mild fever and five (16%) moderate fever. Pharmacological treatment with antipyretic drugs was required in 18 (56%) out of 32 patients and was associated with the resolution of symptoms. No patient required hospital admission and no arrhythmic episode was recorded in patients with ICD within 48 h after vaccination. No induced type 1 BrS ECG pattern and new ECG features were found among patients with moderate fever. CONCLUSION: Fever is a common side effect in BrS patients after the Covid-19 vaccination. Careful evaluation of body temperature and prompt treatment with antipyretic drugs may be needed.


Asunto(s)
Antipiréticos , Síndrome de Brugada , Vacunas contra la COVID-19 , COVID-19 , Desfibriladores Implantables , Adulto , Antipiréticos/efectos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiología , Síndrome de Brugada/terapia , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Electrocardiografía , Femenino , Fiebre/inducido químicamente , Fiebre/diagnóstico , Fiebre/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Vacunación/efectos adversos
13.
Pacing Clin Electrophysiol ; 45(12): 1345-1348, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36208140

RESUMEN

An 80-year-old woman received a dual chamber pacemaker (Boston Scientific Accolade MRI DR) for pre-syncopal episodes associated with transient II-degree atrioventricular block type 1 and 2:1, recorded in 24-h Holter monitoring. Due to residual AV conduction with I-degree AV block, the pacemaker was set with the RYTHMIQ® algorithm, in order to reduce inappropriate ventricular pacing. A month later the patient started to complain of severe asthenia and bradycardia (46-48 bpm). Telemetry-supported pacemaker control revealed III-degree AV block with junctional escape rhythm, unmasking missed switch of RYTHMIQ® algorithm.


Asunto(s)
Bloqueo Atrioventricular , Humanos , Anciano de 80 o más Años , Bloqueo Atrioventricular/terapia
14.
Pacing Clin Electrophysiol ; 45(12): 1409-1414, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36214206

RESUMEN

INTRODUCTION: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). OBJECTIVE: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. METHODS AND RESULTS: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. CONCLUSION: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Niño , Humanos , Desfibriladores Implantables/efectos adversos , Adolescente , Muerte Súbita Cardíaca/prevención & control
15.
Echocardiography ; 39(6): 768-775, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35524703

RESUMEN

INTRODUCTION: Two-dimensional strain echocardiography (2D-SE) is a reliable method for measuring deformation of the left ventricle. AIM OF THE STUDY: Aim of the study was to determine changes in 2D-SE parameters over time collected during dipyridamole stress echo-cardiography (dipy-stress) and prognosis of patients with non-diagnostic dipy-stress results. METHODS: In the first phase of the study, assessment of a prospective enrolled population with a non-diagnostic dipy-stress test result was conducted, checking through coronary CT angiography (CCTA) the presence of coronary artery disease (CAD). In the follow-up phase, an echocardiographic re-evaluation and outcome analysis during a mean follow-up of 78 months was carried out. RESULTS: In the first phase, Global Circumferential Strain (GCS) values were similar in the CCTA positive and CCTA negative groups at rest and after stress. For Global Longitudinal Strain (GLS), there was a significant reduction (p < .0001) in the CCTA positive group compared to the CCTA negative group. After 78 ± 9 months none of the enrolled patients experimented cardiac events. Values of GCS, both at rest and after stress, did not differ statistically comparing follow-up values with baseline ones. No statistically significant changes were seen in the same analysis for GLS rest and stress values, between baseline and follow-up in the two groups. CONCLUSIONS: Performing 2D-SE during dipy-stress can detect mild CAD that conventional stress-tests miss. Patients with mild coronary stenosis may have a favorable mid-term prognosis, but efforts should be made to investigate the decrease trend in GLS, at rest and after stress, reported in this patient group.


Asunto(s)
Enfermedad de la Arteria Coronaria , Isquemia Miocárdica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Ecocardiografía de Estrés/métodos , Estudios de Seguimiento , Humanos , Isquemia Miocárdica/diagnóstico por imagen , Pronóstico , Estudios Prospectivos , Reproducibilidad de los Resultados , Función Ventricular Izquierda
16.
J Electrocardiol ; 73: 52-54, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35660341

RESUMEN

Atrial fibrillation (AF) is the most common cardiac arrhythmia in adults with substantial morbidity and mortality. The diagnosis of AF is established by electrocardiogram showing heart rhythm without clear P waves with irregular RR intervals. The electrocardiographic diagnosis of AF is not always easy and can still hide pitfalls even for the most experienced cardiologist. We present the case of an 86 years old patient admitted to our hospital for Covid-19 infection affected by dilated cardiomyopathy with an electrocardiogram showing a non-specific intraventricular conduction delay mimicking sinus rhythm in the presence of AF.


Asunto(s)
Fibrilación Atrial , COVID-19 , Adulto , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Electrocardiografía , Bloqueo Cardíaco , Ventrículos Cardíacos , Humanos
17.
J Electrocardiol ; 74: 46-53, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35964522

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) is the main cardiac cause of stroke, but it frequently remains undetected. In patients with cryptogenic stroke an Holter electrocardiogram (ECG) monitoring for AF is recommended. OBJECTIVE: To evaluate the prognostic role of Non-Conducted Premature Atrial Complexes (ncPACs) recorded on Holter ECG. METHODS: We prospectively enrolled consecutive patients admitted to the Stroke Unit of our hospital with a diagnosis of cryptogenic stroke between December 2018 and January 2020; all patients underwent 24-h Holter ECG monitoring during hospitalization. Two follow-up visits were scheduled, including a 24-h Holter ECG at 3 and 6 months to detect AF. RESULTS: Among 112 patients, 58% were male with an average age of 72.2 ± 12.2 years. At follow-up, AF was diagnosed in 21.4% of the population. The baseline 24-h Holter ECG burden of ncPACs and Premature Atrial Complexes (PACs) was higher in patients with AF detected on follow-up (13.5 vs 2, p = 0.001; 221.5 vs 52; p = 0.01). ROC analysis showed that ncPACs had the best diagnostic accuracy in predicting AF (AUC:0.80; 95% CI 0.68-0.92). Cut-off value of ≥7 for ncPACs burden showed the highest accuracy with sensitivity of 62.5% and specificity 97.7% to predict AF onset at follow-up. Moreover, at multivariate Cox-proportional hazard analysis ncPACs burden ≥7 was a powerful independent predictor of AF onset (HR 12.4; 95% CI 4.8-32.8; p < 0.0001). CONCLUSIONS: NcPACs burden ≥7 represents a new predictor of AF that could guide the screening of this arrhythmia in cryptogenic stroke patients.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Electrocardiografía , Accidente Cerebrovascular/etiología
19.
J Electrocardiol ; 53: 31-35, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30611919

RESUMEN

Since its first description, Brugada Syndrome is characterized by definite ECG abnormalities (J wave, elevated ST segment) confined in right precordial leads. Brugada Pattern (BP) could be found in one or more right precordial leads, at conventional or higher intercostal spaces. A recent study, conducted by our group, reported that slightly less than one half of patients with type 1 BP show a definite ST segment depression (≥0.1 mV with duration ≥ 0.08 s) in the inferior leads. With these premises, 4 distinct ST abnormalities phenotypes can be recognizable in Type 1 BP. We speculated the key role of orientation of right ventricular outflow tract in the thorax, particularly the inclination of anterior wall compared to the sternum, contributing to the determination of these various ECG phenotypes. An interactive program, ECGsim, able to simulate ECG appearance in several anatomical and electrical models, confirmed this assumption. This computed model affirmed the strict relationship between ST segment depression in the inferior leads and the ST segment elevation in right precordial leads, typical of type 1 BP. A horizontal right ventricular outflow tract, in fact, gives raise to abnormal BP vector directed both superiorly and anteriorly, explaining, at the same time, typical BP appearance in right precordial leads and ST segment depression in the inferior leads.


Asunto(s)
Síndrome de Brugada/fisiopatología , Ventrículos Cardíacos/fisiopatología , Modelos Anatómicos , Potenciales de Acción , Simulación por Computador , Electrocardiografía , Humanos , Fenotipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA