Resultados 1 - 11 de 11
Filtrar
1.
J Endovasc Ther ; : 15266028231172368, 2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37154393

RESUMEN

PURPOSE: Endovascular aortic repair has become the preferred elective treatment of infrarenal aortic aneurysms. Aortic pulsatility may pose problems regarding endograft sizing. The aims of this study are to determine the aortic pulsatility in patients with aortic disease and to evaluate the effect of pulsatility on the growth of aneurysms. MATERIALS AND METHODS: In this retrospective study, analyses of computed tomography angiography (CTA) images of 31 patients under conservative treatment for small abdominal aortic aneurysms were performed. Reconstructions of the raw electrocardiography (ECG) gated dataset at 30% and 90% of the R-R cycle were used. After lumen segmentation, total aortic cross-sectional area was measured in diastole and systole in the following zones: Z0, Z3, Z5, Z6, Z8, and Z9. Effective diameters (EDs) were calculated from the systolic (EDsys) and diastolic (EDdia) cross-sectional areas to determine absolute (EDsys - EDdia, mm) and relative pulsatility [(EDsys - EDdia) / EDdia, %]. Diameter of the aneurysms was measured on baseline images and the last preoperative follow-up study of each patient. RESULTS: A total of 806 measurements were completed, 24 pulsatility and 2 growth measurements per patient. The mean pulsatility values at each point were as follows: Z0: 0.7±0.8 mm, Z3: 1.0±0.6 mm, Z5: 1.0±0.6 mm, Z6: 0.8±0.7 mm, Z8: 0.7±1.0 mm, Z9: 0.9±0.9 mm. Follow-up time was 5.5±2.2 years during which a growth of 13.42±9.09 mm (2.54±1.55 mm yearly) was observed. No correlation was found between pulsatility values and growth rate of the aneurysms. CONCLUSION: The pulsatility of the aorta is in a submillimetric range for the vast majority of patients with aortic disease, thus probably not relevant regarding endograft sizing. Pulsatility of the ascending aorta is smaller than that of the descending segment, making an additional oversize of a Z0 implantation questionable. CLINICAL IMPACT: Endovascular aortic repair reqiures precise preoperative planning. Pulsatile changes of the aortic diameter may pose issues regarding endograft sizing. In our retrospective single-centre study, aortic pulsatility of patients with AAA was measured on ECG gated CTA images. Pulsatility values reached a maximum at the descending aorta, however absolute pulsatility values did not exceed 1 mm at any point along the aorta. Therefore, significance of aortic pulsatility regarding the sizing of EVAR prostheses is questionable. Correlation between pulsatility and AAA growth was not found.

2.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37931067

RESUMEN

AIMS: Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. METHODS AND RESULTS: We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter-tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). CONCLUSION: Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Embolia Intracraneal , Venas Pulmonares , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/epidemiología , Incidencia , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento
3.
Comput Med Imaging Graph ; 115: 102372, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38581959

RESUMEN

PURPOSE: To investigate the feasibility of a deep learning algorithm combining variational autoencoder (VAE) and two-dimensional (2D) convolutional neural networks (CNN) for automatically quantifying hard tissue presence and morphology in multi-contrast magnetic resonance (MR) images of peripheral arterial disease (PAD) occlusive lesions. METHODS: Multi-contrast MR images (T2-weighted and ultrashort echo time) were acquired from lesions harvested from six amputated legs with high isotropic spatial resolution (0.078 mm and 0.156 mm, respectively) at 9.4 T. A total of 4014 pseudo-color combined images were generated, with 75% used to train a VAE employing custom 2D CNN layers. A Gaussian mixture model (GMM) was employed to classify the latent space data into four tissue classes: I) concentric calcified (c), II) eccentric calcified (e), III) occluded with hard tissue (h) and IV) occluded with soft tissue (s). Test image probabilities, encoded by the trained VAE were used to evaluate model performance. RESULTS: GMM component classification probabilities ranged from 0.92 to 0.97 for class (c), 1.00 for class (e), 0.82-0.95 for class (h) and 0.56-0.93 for the remaining class (s). Due to the complexity of soft-tissue lesions reflected in the heterogeneity of the pseudo-color images, more GMM components (n=17) were attributed to class (s), compared to the other three (c, e and h) (n=6). CONCLUSION: Combination of 2D CNN VAE and GMM achieves high classification probabilities for hard tissue-containing lesions. Automatic recognition of these classes may aid therapeutic decision-making and identifying uncrossable lesions prior to endovascular intervention.


Asunto(s)
Estudios de Factibilidad , Imagen por Resonancia Magnética , Enfermedad Arterial Periférica , Humanos , Enfermedad Arterial Periférica/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Distribución Normal , Algoritmos , Redes Neurales de la Computación , Aprendizaje Profundo
4.
EJVES Vasc Forum ; 61: 121-125, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38884072

RESUMEN

Introduction: Percutaneous deep venous arterialisation (DVA) is emerging as a promising alternative for limb salvage in chronic limb threatening ischaemia (CLTI) patients without any reasonable anatomical option for conventional revascularisation techniques. However, its mechanism of action remains incompletely understood. This report aimed to find some of the histological alterations occurring in the limb following DVA. Report: This short report presents the case of a 53 year old female who underwent DVA for Rutherford 5 CLTI. Although the intervention was successful and showed evidence of improved blood flow to the foot, the post-operative course was notable due to worsening infection leading to a below knee amputation four weeks later. The blood vessels were harvested for histological analysis, which found features of venous arterialisation such as smooth muscle cell proliferation and neointimal hyperplasia, even in the paired posterior tibial vein that did not undergo DVA. Discussion: This case demonstrated unexpected histological changes occurring in the paired posterior tibial vein that did not undergo DVA. This warrants further investigations to fully understand the mechanisms at play in DVA and to explore the role of the paired vein in sustaining arterialised flow to the foot.

5.
J Vasc Surg Cases Innov Tech ; 9(4): 101263, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37767348

RESUMEN

With the growing prevalence and mortality of peripheral arterial disease, preoperative assessment, risk stratification, and determining the correct indication for endovascular and open surgical procedures are essential for therapeutic decision-making. The effectiveness of interventional procedures is significantly influenced by the plaque composition and calcification pattern. Therefore, the identification of patients for whom endovascular treatment is the most appropriate therapeutic solution often remains a challenge. The most commonly used imaging techniques have their own limitations and do not provide findings detailed enough for specific, personalized treatment planning. Using state-of-the-art noninvasive and invasive imaging modalities, it is now possible to obtain a view, not only of the complex vascular anatomy and plaque burden of the lower extremity arterial system, but also of complex plaque structures and various pathologic calcium distribution patterns. In the future, as these latest advancements in diagnostic methods become more widespread, we will be able to obtain more accurate views of the plaque structure and anatomic complexity to guide optimal treatment planning and device selection. We reviewed the implications of the most recent invasive and noninvasive lower extremity imaging techniques and future directions.

6.
Diagnostics (Basel) ; 13(11)2023 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-37296778

RESUMEN

The novel approach of our study consists in adapting and in evaluating a custom-made variational autoencoder (VAE) using two-dimensional (2D) convolutional neural networks (CNNs) on magnetic resonance imaging (MRI) images for differentiate soft vs. hard plaque components in peripheral arterial disease (PAD). Five amputated lower extremities were imaged at a clinical ultra-high field 7 Tesla MRI. Ultrashort echo time (UTE), T1-weighted (T1w) and T2-weighted (T2w) datasets were acquired. Multiplanar reconstruction (MPR) images were obtained from one lesion per limb. Images were aligned to each other and pseudo-color red-green-blue images were created. Four areas in latent space were defined corresponding to the sorted images reconstructed by the VAE. Images were classified from their position in latent space and scored using tissue score (TS) as following: (1) lumen patent, TS:0; (2) partially patent, TS:1; (3) mostly occluded with soft tissue, TS:3; (4) mostly occluded with hard tissue, TS:5. Average and relative percentage of TS was calculated per lesion defined as the sum of the tissue score for each image divided by the total number of images. In total, 2390 MPR reconstructed images were included in the analysis. Relative percentage of average tissue score varied from only patent (lesion #1) to presence of all four classes. Lesions #2, #3 and #5 were classified to contain tissues except mostly occluded with hard tissue while lesion #4 contained all (ranges (I): 0.2-100%, (II): 46.3-75.9%, (III): 18-33.5%, (IV): 20%). Training the VAE was successful as images with soft/hard tissues in PAD lesions were satisfactory separated in latent space. Using VAE may assist in rapid classification of MRI histology images acquired in a clinical setup for facilitating endovascular procedures.

7.
J Clin Med ; 11(15)2022 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-35893427

RESUMEN

Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1: non-diagnostic, 2: severe artifacts, 3: mild artifacts, 4: no artifacts). Patients were stratified into four groups according to HR (<60/min, 60−65/min, 66−70/min and >70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60−65/min, 66−70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs.

9.
J Clin Med ; 11(15)2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35956102

RESUMEN

Nephroprotective imaging in peripheral arterial disease (PAD) is often crucial. We compared the diagnostic performance of non-contrast Quiescent-interval single-shot magnetic resonance angiography (QISS MRA) and carbon-dioxide digital subtraction angiography (CO2 DSA) in chronic lower extremity PAD patients. A 19-segment lower extremity arterial model was used to assess the degree of stenosis (none, <50%, 50−70%, >70%) and the image quality (5-point Likert scale: 1-non-diagnostic, 5-excellent image quality). Intra-class correlation coefficient (ICC) was calculated for inter-rater reliability. Diagnostic accuracy and interpretability were evaluated using CO2 DSA as a reference standard. 523 segments were evaluated in 28 patients (11 male, mean age: 71 ± 9 years). Median and interquartile range of subjective image quality parameters for QISS MRA were significantly better compared to CO2 DSA for all regions: (aortoiliac: 4 [4−5] vs. 3 [3−4]; femoropopliteal: 4 [4−5] vs. 4 [3−4]; tibioperoneal: 4 [3−5] vs. 3 [2−3]; all regions: 4 [4−5] vs. 3 [3−4], all p < 0.001). QISS MRA out-performed CO2 DSA regarding interpretability (98.3% vs. 86.0%, p < 0.001). Diagnostic accuracy parameters of QISS MRA for the detection of obstructive luminal stenosis (70%<) as compared to CO2 DSA were as follows: sensitivity 82.6%, specificity 96.9%, positive predictive value 89.1%, negative predictive value 94.8%. Regarding the degree of stenosis, interobserver variability for all regions was 0.97 for QISS MRA and 0.82 for CO2 DSA. QISS MRA proved to be superior to CO2 DSA regarding subjective image quality and interpretability for the imaging of chronic lower extremity PAD.

10.
PLoS One ; 16(8): e0256317, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34428222

RESUMEN

PURPOSE: To evaluate factors associated with pseudoaneurysm (PSA) development. METHODS: Between January 2016 and May 2020, 30,196 patients had invasive vascular radiological or cardiac endovascular procedures that required arterial puncture. All patients with PSA were identified. A matched (age, gender, and type of the procedure) control group of 134 patients was created to reveal predictors of PSA formation. RESULTS: Single PSAs were found in 134 patients. Fifty-three PSAs developed after radiological procedures (53/6555 [0.8%]), 31 after coronary artery procedures (31/18038 [0.2%]), 25 after non-coronary artery cardiac procedures (25/5603 [0.4%]), and 25 due to procedures in which the arterial puncture was unintended. Thirty-four PSAs (25.4%) were localized to the upper extremity arteries (vascular closure device [VCD], N = 0), while 100 (74.6%) arose from the lower extremity arteries (VCD, N = 37). The PSA prevalence was 0.05% (10/20478) in the radial artery, 0.1% (2/1818) in the ulnar artery, 1.2% (22/1897) in the brachial artery, and 0.4% (99/22202) in the femoral artery. Treatments for upper and lower limb PSAs were as follows: bandage replacement (32.4% and 14%, respectively), ultrasound-guided compression (11.8% and 1%, respectively), ultrasound-guided thrombin injection (38.2% and 78%, respectively), and open surgery (17.6% and 12%, respectively). Reintervention was necessary in 19 patients (14.2%). The prevalence of PSA for the punctured artery with and without VCD use was 37/3555 (1%) and 97/27204 (0.4%), respectively (OR, 2.94; 95% CI, 1.95-4.34; P<0.001). The effect of red blood cell (RBC) count (P<0.001), hematocrit value (P<0.001), hemoglobin value (P<0.001), international normalized ratio (INR; P<0.001), RBC count-INR interaction (P = 0.003), and RBC count-VCD use interaction (P = 0.036) on PSA formation was significant. CONCLUSION: Patients in whom the puncture site is closed with a VCD require increased observation. Preprocedural laboratory findings are useful for the identification of patients at high risk of PSA formation.


Asunto(s)
Aneurisma Falso/epidemiología , Arteria Braquial/cirugía , Procedimientos Endovasculares/efectos adversos , Arteria Femoral/cirugía , Anciano , Aneurisma Falso/etiología , Aneurisma Falso/patología , Arteria Braquial/fisiopatología , Femenino , Arteria Femoral/fisiopatología , Humanos , Extremidad Inferior/fisiopatología , Extremidad Inferior/cirugía , Masculino , Persona de Mediana Edad , Punciones/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos , Dispositivos de Cierre Vascular/efectos adversos
11.
Eur J Radiol ; 145: 110032, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34800835

RESUMEN

BACKGROUND: Filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) are ubiquitously applied in the reconstruction of coronary CT angiography (CCTA) datasets. However, currently no data is available on the impact of a model-based adaptive filter (MBAF2), recently developed for a dedicated cardiac scanner. PURPOSE: Our aim was to determine the effect of MBAF2 on subjective and objective image quality parameters of coronary arteries on CCTA. METHODS: Images of 102 consecutive patients referred for CCTA were evaluated. Four reconstructions of coronary images (FBP, ASIR, MBAF2, ASIR + MBAF2) were co-registered and cross-section were assessed for qualitative (graininess, sharpness, overall image quality) and quantitative [image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] image quality parameters. Image noise and signal were measured in the aortic root and the left main coronary artery, respectively. Graininess, sharpness, and overall image quality was assessed on a 4-point Likert scale. RESULTS: As compared to FBP, ASIR, and MBAF2, ASIR + MBAF2 resulted in reduced image noise [53.1 ± 12.3, 30.6 ± 8.5, 36.3 ± 4.2, 26.3 ± 4.0 Hounsfield units (HU), respectively; p < 0.001], improved SNR (8.4 ± 2.6, 14.1 ± 3.6, 11.8 ± 2.3, 16.3 ± 3.3 HU, respectively; p < 0.001) and CNR (9.4 ± 2.7, 15.9 ± 4.0, 13.3 ± 2.5, 18.3 ± 3.5 HU, respectively; p < 0.001). No difference in sharpness was observed amongst the reconstructions (p = 0.08). Although ASIR + MBAF2 was non-superior to ASIR regarding overall image quality (p = 0.99), it performed better than FBP (p < 0.001) and MBAF2 (p < 0.001) alone. CONCLUSION: The combination of ASIR and MBAF2 resulted in reduced image noise and improved SNR and CNR. The implementation of MBAF2 in clinical practice may result in improved noise reduction performance and could potentiate radiation dose reduction.


Asunto(s)
Angiografía por Tomografía Computarizada , Interpretación de Imagen Radiográfica Asistida por Computador , Algoritmos , Angiografía Coronaria , Humanos , Dosis de Radiación , Relación Señal-Ruido , Tomografía Computarizada por Rayos X