Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Birth ; 50(3): 571-577, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36265127

RESUMEN

BACKGROUND: Multiple benefits for both, mother and baby have been reported from immediate skin-to-skin care (SSC). The aim of this study was to analyze the influence of SSC on operative time and blood loss in primary cesarean births for breech presentation. METHODS: A SSC protocol for cesarean birth was implemented in our institution on February 25, 2019. In this single-center retrospective cohort study, we compared the outcomes of planned primary cesarean births for breech presentation at term before and after its implementation. RESULTS: Data from 110 women who had a cesarean birth for breech presentation at term were analyzed, 55 in each group. Group 1 were women who had immediate SSC and Group 2 were women without immediate SSC. Maternal and surgical characteristics, and neonatal outcomes were similar in both groups. The mean operative time was 3.22 minutes shorter in the immediate SSC group compared with the not immediate SSC group (37.13 ± 12.27 vs 40.35 ± 12.23 minutes; P = 0.171). CONCLUSIONS: In conclusion, immediate SSC following a low-risk cesarean birth for breech presentation neither prolongs the operative time nor increases blood loss during the procedure. Although we were unable to demonstrate a significant reduction in the operative time with the immediate SSC protocol, a decrease of 3 minutes was noted.


Asunto(s)
Presentación de Nalgas , Embarazo , Recién Nacido , Femenino , Humanos , Masculino , Estudios Retrospectivos , Tempo Operativo , Cesárea , Madres , Parto Obstétrico
2.
Acta Obstet Gynecol Scand ; 99(10): 1387-1395, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32306380

RESUMEN

INTRODUCTION: Doppler ultrasound cardiotocography is a non-invasive alternative that, despite its poor specificity, is often first choice for intrapartum monitoring. Doppler ultrasound suffers from signal loss due to fetal movements and is negatively correlated with maternal body mass index (BMI). Reported accuracy of fetal heart rate monitoring by Doppler ultrasound varies between 10.6 and 14.3 bpm and reliability between 62.4% and 73%. The fetal scalp electrode (FSE) is considered the reference standard for fetal monitoring but can only be applied after membranes have ruptured with sufficient cervical dilatation and is sometimes contra-indicated. A non-invasive alternative that overcomes the shortcomings of Doppler ultrasound, providing reliable information on fetal heart rate, could be the answer. Non-invasive fetal electrocardiography (NI-fECG) uses a wireless electrode patch on the maternal abdomen to obtain both fetal and maternal heart rate signals as well as an electrohysterogram. We aimed to validate a wireless NI-fECG device for intrapartum monitoring in term singleton pregnancies, by comparison with the FSE. MATERIAL AND METHODS: We performed a multicenter cross-sectional observational study at labor wards of 6 hospitals located in the Netherlands, Belgium, and Spain. Laboring women with a healthy singleton fetus in cephalic presentation and gestational age between 36 and 42 weeks were included. Participants received an abdominal electrode patch and FSE after written informed consent. Accuracy, reliability, and success rate of fetal heart rate readings were determined, using FSE as reference standard. Analysis was performed for the total population and measurement period as well as separated by labor stage and BMI class (≤30 and >30 kg/m2 ). RESULTS: We included a total of 125 women. Simultaneous registrations with NI-fECG and FSE were available in 103 women. Overall accuracy is -1.46 bpm and overall reliability 86.84%. Overall success rate of the NI-fECG is around 90% for the total population as well as for both BMI subgroups. Success rate dropped to 63% during second stage of labor, similar results are found when looking at the separate BMI groups. CONCLUSIONS: Performance measures of the NI-fECG device are good in the overall group and the separate BMI groups. Compared with Doppler ultrasound performance measures from the literature, NI-fECG is a more accurate alternative. Especially, when women have a higher BMI, NI-fECG performs well, resembling FSE performance measures.


Asunto(s)
Cardiotocografía/instrumentación , Frecuencia Cardíaca Fetal , Tecnología Inalámbrica , Adulto , Índice de Masa Corporal , Cardiotocografía/métodos , Estudios Transversales , Electrodos , Femenino , Humanos , Embarazo , Estudios Prospectivos , Reproducibilidad de los Resultados
3.
J Perinat Med ; 48(7): 694-699, 2020 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-32692705

RESUMEN

Objectives The purpose of this study is to compare the vacuum extractor cup application technique described by Bird vs. the technique described by Vacca on a simulation model. Methods Six obstetricians participated in the study. Each obstetrician performed eight vacuum assisted deliveries using the Bird technique and eight vacuum assisted deliveries using the Vacca 5-Steps technique. Results A total of 96 vacuum assisted deliveries were performed. The mean distance from the centre of the cup to the flexion point was 1.78±0.96 cm for the Bird technique and 1.05±0.60 cm for the Vacca technique (p<0.001). The lateral distance (over the parietal bone) was 1.16±0.69 cm for the Bird technique and 0.66±0.52 cm for the Vacca technique (p<0.001). The vertical distance (towards the frontal or occipital bone) was 1.12±1.02 cm for the Bird technique and 0.67±0.55 cm for the Vacca technique (p=0.009). In occipito anterior positions, there were no significant differences between both techniques. Conclusions The Vacca technique was better in transverse and posterior positions.


Asunto(s)
Obstetricia/normas , Práctica Profesional , Extracción Obstétrica por Aspiración , Femenino , Enseñanza Mediante Simulación de Alta Fidelidad , Humanos , Posicionamiento del Paciente/clasificación , Embarazo , Diagnóstico Prenatal/métodos , Utilización de Procedimientos y Técnicas/estadística & datos numéricos , Mejoramiento de la Calidad , Extracción Obstétrica por Aspiración/instrumentación , Extracción Obstétrica por Aspiración/métodos
5.
J Perinat Med ; 43(2): 171-5, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25032803

RESUMEN

OBJECTIVES: To evaluate the accuracy of criteria followed by obstetricians when performing a Kristeller maneuver in cases of prolonged second stage of labor. METHODS: In this prospective observational study, the station of the fetal head was measured using the angle of progression (intrapartum ultrasound) just prior to the intervention of the managing obstetrician in 52 women with prolonged second stage of labor. The managing obstetricians were blinded to the sonographic results. The decision of performing a Kristeller maneuver was taken by the obstetricians based on digital palpation and their experience. Delivery mode, Apgar score, umbilical artery pH value, episiotomy, perineal tears, bleeding, and time to delivery were recorded. RESULTS: Kristeller maneuver was performed in 36/52 (69.2%) cases. There were no significant differences between the Kristeller and the non-Kristeller group regarding the angle of progression. There were no significant differences between both groups with respect to delivery mode, perineal tears, episiotomy, bleeding, Apgar score, and umbilical artery pH value. CONCLUSIONS: Our study failed to define any criteria followed by obstetricians when performing a Kristeller maneuver in cases of prolonged second stage of labor. There was no relation between the angle of progression and the decision to perform a Kristeller maneuver.


Asunto(s)
Parto Obstétrico/métodos , Distocia/terapia , Adulto , Parto Obstétrico/estadística & datos numéricos , Distocia/diagnóstico por imagen , Femenino , Humanos , Embarazo , Estudios Prospectivos , Ultrasonografía
6.
Eur J Obstet Gynecol Reprod Biol ; 301: 181-185, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39151253

RESUMEN

OBJECTIVE: The Kielland's forceps is the most used forceps for assisting rotational operative births. There are various maneuvers described for blade insertion. Among these, the most used ones are the direct, first posterior, and wandering maneuver. The objective of this study was to compare these three maneuvers using a simulator. STUDY DESIGN: In this experimental study, 144 rotational forceps-assisted births were conducted using a simulation model, with 72 starting in a right occiput-transverse position and 72 in a left occiput-transverse position. Each of the three maneuvers (direct, first posterior, or wandering) for blade insertion was performed 48 times by a total of 6 operators, comprising 3 obstetricians with over 10 years of experience and 3 trainees. The assessment of forceps application included evaluating the placement of the blades in terms of asymmetry and the distance from the lock to the posterior fontanelle. Additionally, the study evaluated the number of reinsertions and relocations required, the perceived difficulty of the procedure, and the operator's level of experience. RESULTS: There were no statistically significant differences in terms of asymmetry with the three maneuvers. Regarding the distance from the lock to the posterior fontanelle, the best results were obtained with the direct maneuver. There were no differences in the number of reinsertions, relocations, and the perceived difficulty by the operators among the three maneuvers. Experienced obstetricians had better outcomes in terms of the need for reinsertions. CONCLUSION: The direct maneuver offer advantages in the insertion of blades for rotational forceps.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38767218

RESUMEN

OBJECTIVE: Obstetric forceps play an important role in safe childbirth, yet there is a lack of distinction between various forceps types in clinical practice. This study aimed to evaluate and compare perineal pressure and forces on the baby during nonrotational forceps-assisted births using Simpson-Braun forceps, Kielland forceps, and Thierry spatulas on a simulation model. METHODS: This experimental study involved six obstetricians conducting 108 forceps-assisted births on a simulation model. Instruments were assessed for their impact on perineal pressure, traction force, and operator-assessed difficulty. RESULTS: Thierry's spatulas exerted the lowest force on the baby, while Kielland forceps exhibited the lowest perineal pressure, though not statistically significant. An experienced obstetrician demonstrated less perineal pressure with Simpson forceps. Notably, no significant differences in difficulty were observed between instruments. CONCLUSION: This study highlights distinctions in forceps performance, with Thierry spatulas applying the least force on the fetal head, while an experienced obstetrician fared better with Simpson forceps in terms of perineal pressure. Kielland forceps remain a viable alternative for nonrotational forceps births, showing comparable outcomes.

8.
Eur J Obstet Gynecol Reprod Biol ; 290: 88-92, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37742455

RESUMEN

OBJECTIVE: Maternal lateral postures provide advantages during childbirth. This study aims to investigate the feasibility of assisting vacuum births in maternal lateral postures in a simulation model. STUDY DESIGN: In a simulation model, four obstetricians and four medical students were randomly allocated to perform vacuum-assisted births first in maternal lateral posture or lithotomy. A modification of Aldo Vacca's 5-step technique was developed to assist vacuum-assisted births in lateral posture. The lateral distance, vertical distance, and distance from the cup center to the flexion point were measured for every placement of the cup. RESULTS AND CONCLUSIONS: A total of 128 vacuum-assisted births were performed. The mean distance to the flexion point was 1.15 ± 0.71 cm for the lithotomy posture and 1.31 ± 0.82 cm for the lateral posture (P = 0.127). There were no statistically significant differences in vacuum extractor cup placement accuracy based on maternal posture. Performing vacuum-assisted births in maternal lateral posture is feasible in a simulation model. The technique is easy to learn, and the differences in cup placement between the lateral and lithotomy postures are small.


Asunto(s)
Parto Obstétrico , Postura , Femenino , Humanos , Embarazo , Simulación por Computador , Parto Obstétrico/métodos , Extracción Obstétrica por Aspiración
9.
Eur J Obstet Gynecol Reprod Biol ; 285: 46-49, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37044018

RESUMEN

OBJECTIVE: This study aimed to assess whether intrapartum ultrasound (ITU) measurements in maternal lateral posture are superimposable to ITU measurements in semi-recumbent position. STUDY DESIGN: A single-center, repeated measures design was used. Women in the second stage of labor were randomized to ITU first in semi-recumbent followed by ITU in side-lying posture without and with contraction, or inversely. The angle of progression (AOP) and the head-perineum distance (HPD) between contractions (AOP1 and HPD1) and with contraction (AOP2 and HPD2) were measured in each maternal posture. The differences between AOP1 and AOP2 (dAOP), and between HPD1 and HPD2 (dHPD) were calculated. RESULTS AND CONCLUSIONS: Forty-two women participated in the study. A generalized estimating equation model showed that AOP1 (-3.00°; 95 % CI -5.77 to -0.23; p = 0.03) and AOP2 (-4.14°; 95 % CI -7.20 to -1.08; p = 0.008) were lower in semi-recumbent compared to maternal lateral posture. HPD1 (+1.43 mm; 95 % CI 0.05-2.81; p = 0.042) and HPD2 (+1.53 mm; 95 % CI 0.17-2.89; p = 0.03) were higher in semi-recumbent position. Differences in the ITU measurements in maternal lateral posture compared to semi-recumbent position are small. Monitoring the second stage of labor with ITU in lateral maternal posture is possible.


Asunto(s)
Trabajo de Parto , Parto , Embarazo , Femenino , Humanos , Postura , Ultrasonografía , Proyectos de Investigación
10.
J Matern Fetal Neonatal Med ; 35(15): 2976-2979, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32662314

RESUMEN

INTRODUCTION: The covid-19 pandemic has meant a change in working protocols, as well as in Personal Protective Equipment (PPE). Obstetricians have had to adapt quickly to these changes without knowing how they affected their clinical practice. The aim of the present study was to evaluate how COVID-19 pandemic and PPE can affect operative time, operating room time, transfer into the operating room to delivery time and skin incision to delivery time in cesarean section. METHODS: This is a single-center retrospective cohort study. Women with confirmed or suspected SARS-CoV-2 infection having a cesarean section after March 7th, 2020 during the COVID-19 pandemic were included in the study. For each woman with confirmed or suspected SARS-CoV-2 infection, a woman who had a cesarean section for the same indication during the COVID-19 pandemic and with similar clinical history but not affected by SARS-CoV-2 was included. RESULTS: 42 cesarean sections were studied. The operating room time was longer in the COVID-19 confirmed or suspected women: 90 (73.0 to 110.0) versus 61 (48.0 to 70.5) minutes; p < .001. The transfer into the operating room to delivery time was longer, but not statistically significant, in urgent cesarean sections in COVID-19 confirmed or suspected women: 25.5 (17.5 to 31.75) versus 18.0 (10.0 to 26.25) minutes; p = .113. CONCLUSIONS: There were no significant differences in the operative time, transfer into the operating room to delivery time and skin incision to delivery time when wearing PPE in cesarean section. The COVID-19 pandemic and the use of PPE resulted in a significant increase in operating room time.


Asunto(s)
COVID-19 , Equipo de Protección Personal , COVID-19/epidemiología , COVID-19/prevención & control , Cesárea/métodos , Femenino , Humanos , Tempo Operativo , Pandemias/prevención & control , Embarazo , Estudios Retrospectivos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA