RESUMEN
The analysis of highly polar pesticides is challenging due to their unique physicochemical properties, requiring specialized chromatographic techniques for their accurate and sensitive detection. Furthermore, the high level of co-extracted polar matrix components that can co-elute with the analytes can interfere with the analysis. Consequently, there is lack of pesticide monitoring data, as the European Food Safety Authority has pointed out. This article explores the overcoming of such difficulties in the analysis of these compounds. Analytical methodologies for the extraction, clean-up, and direct determination of 11 highly polar anionic pesticides, including glyphosate, glufosinate, ethephon, fosetyl-aluminium, and their related metabolites in complex food matrices such as honey and pollen by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry were successfully developed and validated. Solid-phase extraction and micro-solid-phase extraction employing strong anion exchange (SAX) cartridges were implemented for clean-up. The automation and miniaturization of SAX clean-up for these compounds were achieved for the first time. For method validation, SANTE/11312/2021 guideline was followed. Recoveries were between 70 and 120%, with RSDs below 20%. Limits of quantitation ranged from 0.005 to 0.020 mg kg-1. Linearity was evaluated from 0.002 to 0.200 mg kg-1. Matrix effects were assessed, showing medium to low signal suppression for most compounds. AMPA and glufosinate presented the highest signal suppression, but it was reduced after SAX clean-up. Analysis of real honey and pollen samples revealed the occurrence of the studied compounds in beehive products and showed the applicability of the validated methodologies for routine control of these complex samples.
Asunto(s)
Residuos de Plaguicidas , Plaguicidas , Plaguicidas/análisis , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Extracción en Fase Sólida , Residuos de Plaguicidas/análisisRESUMEN
Abundant studies have been published evaluating different parameters of reverse-phase liquid chromatography (LC) and supercritical fluid chromatography (SFC), both coupled to electrospray (ESI)/mass spectrometry (MS) for pesticide residue analysis. However, there is a lack of a comprehensive comparative study that facilitates deep knowledge about the benefits of using each technique. In the present study, the same mass spectrometer was used coupled to both liquid and supercritical fluid chromatographies with a multiresidue method of 215 compounds, for the analysis of pesticide residues in food samples. Through the injection of the spiked extracts, separate experiments were conducted. A study of the optimum ion source temperature using the different chromatography modes was performed. The results were evaluated in terms of sensitivity with tomato, leek, onion, and orange as representative fruit and vegetable matrices. The compounds which reported the highest area values in each chromatography were evaluated through their substance groups and polarity values. The impact of matrix effects obtained in tomato matrix was similar for both cases; however, SFC clearly showed better results in analyzing matrices with a higher number of natural co-extracted compounds. This can be explained by the combination of two effects: (i) chromatography separation and (ii) ion source efficiency. The chromatographic elution presented different profiles of matrix components, which had diverse impact on the coelution with the analytes, being more beneficial when SFC was used in the matrices studied. The data showed that the best results obtained in SFC are also related to a higher ionization efficiency even when the ESI emitter tip was not optimized for SFC flow. In the present study a comprehensive evaluation of the benefits and drawbacks of these chromatography modes for routine pesticide residue analysis related to target compounds/commodities is provided.
Asunto(s)
Cromatografía Liquida/métodos , Cromatografía con Fluido Supercrítico/métodos , Residuos de Plaguicidas/análisis , Espectrometría de Masa por Ionización de Electrospray/métodos , Residuos de Plaguicidas/normas , Estándares de ReferenciaRESUMEN
In this comprehensive study, we evaluated the feasibility of using hydrogen instead of helium as a carrier gas in a GC-MS/MS system for pesticide residue analysis, spanning three matrices: pepper, tomato, and zucchini. Initial assessments focused on the ion source's chemical inertness, employing nitrobenzene as a benchmark to monitor the hydrogenation process. A method with a duration of less than 12 minutes was developed, achieving good chromatographic peak resolution attributable to the enhanced chromatographic performance of hydrogen as a carrier gas. The study emphasized the optimization of system parameters, testing various ion source temperatures, detector voltages, and injection volumes. Sensitivity assessments, based on the DG-SANTE criteria, indicated that the majority of compounds were identifiable at a concentration of 5 µg kg-1 (81% in tomato, 84% in pepper and 73% in zucchini). Detailed validation for reproducibility, matrix effects, and linearity across 150 pesticides unveiled generally favorable outcomes, with a notable majority of compounds displaying low matrix effects, satisfactory linearity ranges and good reproducibility with most compounds returning a relative standard deviation (RSD) below 10%. When applied to 15 real samples, the hydrogen-based system's performance was juxtaposed against a helium-based counterpart, revealing that results are very comparable between both systems. This comparative approach highlights hydrogen's potential as a reliable and efficient carrier gas in pesticide residue analysis for routine food control laboratories, overcoming difficulties resulting from the lack of helium supplies.
Asunto(s)
Residuos de Plaguicidas , Plaguicidas , Espectrometría de Masas en Tándem/métodos , Frutas/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Verduras/química , Plaguicidas/análisis , Helio/análisis , Residuos de Plaguicidas/análisis , Residuos de Plaguicidas/química , Reproducibilidad de los Resultados , Hidrógeno/análisisRESUMEN
Highly polar pesticides are frequently used in agriculture. However, their physicochemical properties make very difficult the analysis of these compounds following common procedures. Polar pesticides show poor retention and peak shapes in the common stationary phases used for multiresidue methods of pesticides. For this reason, multiple columns with different stationary phases have been developed to perform the analysis of these particular compounds. The column evaluated in this method uses a new hybrid stationary phase with a mixed-mode between hydrophilic interaction liquid chromatography (HILIC) and ion exchange interactions. The retention modes are dependant on mobile phase conditions and can be easily switched. The aim of this study can be summarized in the next bullet points: ⢠Performance evaluation of 10 anionic compounds in different column sizes of the hybrid stationary phase. ⢠Validation of the method in terms of sensitivity, linearity, and matrix effects in four different matrices: tomato, orange, onion and quince. ⢠Improvement of the retention time robustness.
RESUMEN
Serious difficulties in evaluating the fungicides captan and folpet by the usual chromatography systems coupled to mass spectrometry are well known. These compounds are highly prone to degradation due to different conditions into tetrahydrophthalimide (THPI) and phthalimide (PHI). Such an effect can be produced at different stages of the analytical procedure or during the growing crop, making their evaluation troublesome. As a consequence, the quantification of captan and folpet is typically performed through or together these metabolites. However, imide ring metabolites can be produced by other unknown sources, including other phthalimide derived pesticides enabling false positive results. For this reason, in the last decade, laboratories demand a robust method to quantify captan and folpet, that overcomes such a situation. In the present work, various operational parameters were optimized to ensure the no degradation of captan and folpet facilitated by supercritical fluid chromatography coupled to mass spectrometry (SFC-MS/MS). A direct comparison with reverse-phase LC-MS/MS and GC-MS/MS was conducted for comparative purposes. The representative commodities selected for this evaluation were pepper and tomato. Furthermore, possible oxidative degradation during the sample milling step was also evaluated and avoided by the application of crio-milling conditions and ascorbic acid addition. By the proposed procedure, captan and folpet were recovered in both matrices at the 84%-105% range and with an RSD below 8% at two concentration levels: 10 and 50 µg/kg. On the contrary, with GC-MS/MS, captan and folpet were not recovered, and, as a consequence, their evaluation was possible only by THPI and PI. In the case of LC-MS/MS a significant decrease in the sensitivity was observed compared to SFC-MS/MS. Other validation parameters evaluated were satisfactory. This new approach can assess the correct analysis of captan and folpet at low concentrations in fruits and vegetables.
RESUMEN
The presence of pesticide residues in bees is of great interest, given the central role of bees as indicators for environmental assessment. The goal of this article is to propose a method to capture enhanced chemical information for these central environmental indicators. Most of the methods rely on the analysis of pooled samples rather than individual specimens due to practical sample preparation method considerations and limitations in sensitivity. This leads to miss information on the mapping of pesticides and actual amount of pesticide per specimen. In this article, a nanoflow liquid chromatography system coupled to high resolution mass spectrometry (using a hybrid quadrupole-Orbitrap instrument) has been applied for the development of a multiresidue pesticide method for the determination of 162 multiclass pesticides in specific part of honeybee samples (ca. abdomen, head or thorax). The reduced flow rate provided an enhancement in sensitivity and a strong reduction of matrix effects, thus only a quick and simple ultrasound assisted extraction using minute amount of sample was required. Satisfactory results were obtained for all tested analytes with concentration levels detected lower than 0.5â¯ngâ¯g-1 in all cases, thus being acceptable for monitoring purposes. Matrix effect was negligible for 94% of compounds. Extraction recoveries ranged from 70% to 105%, being within SANTE guidelines. Finally, the applicability of the method was demonstrated, by successful application to the analysis of contaminated honeybee samples, extracting useful information from specific bee parts of single specimens, thus, enabling pseudo spatially resolved chemical information.
Asunto(s)
Residuos de Plaguicidas/análisis , Animales , Abejas , Cromatografía Liquida , Espectrometría de Masas en TándemRESUMEN
Evaluation of chiral pesticides remains a frequently neglected matter in routine food control laboratories. This fact is due to the existence of many residue definitions but also due to the lack of robust instrumental methods for the evaluation of these isomeric compounds. However, supercritical fluid chromatography coupled to mass spectrometry (SFC-ESI-MS/MS) has been demonstrated to perform fast and highly efficient separations without the need to change the mobile phase employed in multiresidue pesticide analyses. Regarding chiral stationary phase columns, the polysaccharide-based ones clearly demonstrate the best separation technology. Two polysaccharide-based columns were tested in this study, and the robustness of their combination with SFC was verified. The enantiomers of lambda-cyhalothrin and metalaxyl were studied precisely due to their markedly distinct toxicity and enantioselectivity. Furthermore, the acute reference dose for gamma-cyhalothrin is half in comparison with its enantiomer (0.0025 and 0.005 mg/kg respectively), which is present in the lambda-cyhalothin residue definition. These enantiomers were analyzed in terms of linearity, reproducibility, and matrix effects in four representative matrices (tomato, orange, leek, and cayenne). Additionally, field tests under greenhouse conditions for these compounds were performed. The results obtained after different sample collections revealed a similar degradation in lambda-cyhalothrin enantiomers (R, S, S, and S, R, R) but not in the case of metalaxyl-M (mefenoxam) where the degradation in tomato was 2 to 6 times less in comparison with its S-enantiomer.
Asunto(s)
Alanina/análogos & derivados , Cromatografía con Fluido Supercrítico/métodos , Nitrilos/análisis , Plaguicidas/análisis , Piretrinas/análisis , Alanina/análisis , Alanina/química , Nitrilos/química , Plaguicidas/química , Polisacáridos/química , Piretrinas/química , Reproducibilidad de los Resultados , Estereoisomerismo , Espectrometría de Masas en TándemRESUMEN
This study describes a comprehensive comparison between supercritical fluid chromatography (SFC) and gas chromatography (GC) coupled to mass spectrometry for the analysis of pyrethroids in vegetable matrices. The ionization process used was electrospray ionization (ESI) in SFC and electron ionization in GC. In general, liquid chromatography coupled to mass spectrometry with ESI sources provides poor results for pyrethroid detection, as described in previous literature. A total of 14 pyrethroids were selected, together with 6 representative matrices. The differences in chromatographic separation and ionization process were assessed. Similar results were obtained in terms of sensitivity (limits of quantification close to 2 µg/kg, injecting the same amount of sample), matrix effect, and linearity. A total of 17 real samples were analyzed by both systems, obtaining similar results. These data suggest that SFC offers a suitable alternative to GC in the analysis of pyrethroids and allows for their inclusion in a wider multiresidue method.
Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Insecticidas/química , Piretrinas/química , Espectrometría de Masas en Tándem/métodos , Verduras/química , Contaminación de Alimentos/análisis , Estructura MolecularRESUMEN
This study describes the high sensitivity and the reduced ion suppression and matrix effect that can be achieved by supercritical fluid chromatography (SFC) in the analysis of dried spices as complex matrices. Samples selected for the evaluation were cayenne and black pepper, which are representative of complex dried spices. To carry out the evaluation of this technique, blank samples were fortified with a solution containing 162 pesticides at two concentration levels (50 and 200⯵gâ¯kg-1). During the modified QuEChERS method, EMR sorbent was used as dispersive SPE in the clean-up step. The samples were analysed by supercritical fluid chromatography coupled to tandem mass spectrometry. The validation parameters studied were recovery, inter and intraday precision, linearity and matrix effect. Recoveries for the majority of compounds were in the 70-120% range recommended by DG-SANTE guidelines and showed a precision lower than 20% in terms of RSD. Matrix effect was low (0-20% signal suppression) for 132 pesticides in cayenne and 91 in black pepper. The method was used to analyse 47 real samples of spices from different countries. A high number of these samples presented one or more pesticides (81%). Some of these detected pesticides are not approved in the European Union and, in many cases, the positive findings exposed concentrations that exceed the EU MRLs.
Asunto(s)
Contaminación de Alimentos/análisis , Residuos de Plaguicidas/análisis , Especias/análisis , Cromatografía con Fluido Supercrítico/métodos , Magnoliopsida/química , Espectrometría de Masas en Tándem/métodosRESUMEN
Ion chromatography coupled to a quadrupole Orbitrap mass analyzer was used to develop a multiresidue method for the determination of highly polar pesticides and their metabolites (chlorate, perchlorate, fosetyl-aluminum, glyphosate, aminomethylphosphonic acid (AMPA), phosphonic acid, N-acetyl AMPA, and N-acetyl glyphosate) in fruits and vegetables. After extraction with methanol, samples were diluted 5× with water. No derivatization was applied. Pesticides were separated in an anion-exchange column. Water was used as the ion chromatography mobile phase. A gradient was created by increasing the concentration of KOH in the mobile phase. Ion chromatography provided good and stable retention and separation for all studied compounds. All investigated pesticides had an LOQ of 0.01 mg/kg and a linear range of 0.01-0.50 mg/kg. The ion ratio of the m/z ions produced was stable and adequate (deviation <30%) in all cases. The obtained mass errors (always in full-scan MS and MS2 mode) were <0.2 mDa. The high resolution (>100 000) provided by the Orbitrap analyzer with the low m/z ions obtained (e.g., m/z 80) was effective in obtaining low background matrix signals. The influence of postcolumn infusion of organic solvent on sensitivity was investigated. Acetonitrile was found to be more effective than methanol, increasing the sensitivity 3× with respect to water. The method was validated for five vegetable-based matrixes. Both the sample processing and the analytical measurement were very fast. Hence, the methodology is ideal for high-throughput work.
Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Contaminación de Alimentos/análisis , Frutas/química , Espectrometría de Masas/métodos , Residuos de Plaguicidas/análisis , Verduras/química , Acetonitrilos/química , Metanol/químicaRESUMEN
Supercritical fluid chromatography coupled to triple quadrupole mass spectrometry has been evaluated for pesticide residues in food. In order to check its advantages and limitations it was developed a method to identify and quantify 164 pesticides in three different matrices (tomato, orange and leek). A carbon dioxide gradient with methanol (containing 1â¯mM ammonium formate) was used allowing a flow rate of 1.5â¯mL/min that made the total run time of 12â¯min without any problem of overpressure. Addition of a post column flow 150⯵L/min of Methanol with ammonium formate/formic acid was necessary to improve the ionization. The matrix effect study revealed that the percentages of pesticides with irrelevant matrix effect (suppression lower than 20%) was 99% in tomato, 87% in orange and 62% in leek, whereas significant suppression (higher than 50%) was not found in tomato and only 1% of the compounds in orange and 3% in leek.These results compare favorably with that typically obtained in LC-MS/MS. The absence of water in the mobile phase, also provided some important advantages regarding LC-MS/MS as (i) higher retention of polar compounds in the column, which elute with high sensitivity and good peak shape and (ii) a general increase of the sensitivity of the analysis, consequence of the high ionization and ion extraction efficiency. Pesticides evaluated were identified following the SANTE/11813/2017. At the spiking concentration of 5⯵g/kg, 98% of the pesticides were identified in tomato, 98% in orange and 94% in leek, whereas for the concentration of 10⯵g/kg all the compounds were identified in tomato and only spiromesifen was not identified in orange and leek. At the concentration of 20⯵g/kg, spiromesifen was also identified in these two matrices. The linearity and reproducibility of the method were evaluated with results which guarantee high quality in the analytical measurements. Even though only 2⯵L of final extract were injected, the sensitivity of the SFC method was enough to achieve stringent LOQs.Real samples, including 6 different fruits and vegetables, were analyzed by the SFC-MS/MS proposed method, the results being similar to those obtained by LC-MS/MS. The method was also applied to a proficiency test of fipronil in eggs with good results in all the cases. Carbon dioxide as mobile phase with methanol as modifier can represent a good alternative to LC-MS/MS with reduction of matrix effects and shorter run times.
Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Alimentos , Residuos de Plaguicidas/análisis , Espectrometría de Masas en Tándem/métodos , Ácido 2,4-Diclorofenoxiacético/análisis , Dihidropiridinas/análisis , Frutas/química , Reproducibilidad de los Resultados , Verduras/químicaRESUMEN
In the last decade, the consumption trend of organic food has increased dramatically worldwide. However, the lack of reliable chemical markers to discriminate between organic and conventional products makes this market susceptible to food fraud in products labeled as "organic". Metabolomic fingerprinting approach has been demonstrated as the best option for a full characterization of metabolome occurring in plants, since their pattern may reflect the impact of both endogenous and exogenous factors. In the present study, advanced technologies based on high performance liquid chromatography-high-resolution accurate mass spectrometry (HPLC-HRAMS) has been used for marker search in organic and conventional tomatoes grown in greenhouse under controlled agronomic conditions. The screening of unknown compounds comprised the retrospective analysis of all tomato samples throughout the studied period and data processing using databases (mzCloud, ChemSpider and PubChem). In addition, stable nitrogen isotope analysis (δ15N) was assessed as a possible indicator to support discrimination between both production systems using crop/fertilizer correlations. Pesticide residue analyses were also applied as a well-established way to evaluate the organic production. Finally, the evaluation by combined chemometric analysis of high-resolution accurate mass spectrometry (HRAMS) and δ15N data provided a robust classification model in accordance with the agricultural practices. Principal component analysis (PCA) showed a sample clustering according to farming systems and significant differences in the sample profile was observed for six bioactive components (L-tyrosyl-L-isoleucyl-L-threonyl-L-threonine, trilobatin, phloridzin, tomatine, phloretin and echinenone).
Asunto(s)
Productos Agrícolas/metabolismo , Alimentos Orgánicos , Metabolómica/métodos , Solanum lycopersicum/metabolismo , Solanum lycopersicum/química , Espectrometría de Masas , Residuos de Plaguicidas/análisis , Análisis de Componente Principal , Reproducibilidad de los Resultados , Estaciones del AñoRESUMEN
In this work, a new method based on nanoflow LC with high-resolution MS was developed for the determination of eight pesticides in pollen and nectar samples, including neonicotinoid insecticides and other selected pesticides commonly found in bees and beeswax. Detection was undertaken with a hybrid quadrupole-Orbitrap mass spectrometer (Q Exactive™) equipped with a commercial nanospray ion source. The extraction of pesticides from pollen samples was performed by a modified micro-QuEChERS method scaled down to Eppendorf tubes, whereas nectar samples were simply diluted with a water-methanol (95 + 5, v/v) solution. Good linearity (>0.999 in all cases) was obtained between 0.05 and 500 µg/kg and between 0.04 and 400 µg/kg for pollen and nectar, respectively. Recovery rates in pollen ranged from 85 to 97%, with RSDs <12%. Matrix effect was evaluated and showed negligible effects for all studied pesticides. The lowest concentration levels tested and validated were 0.5 and 0.4 µg/kg for pollen and nectar matrixes, respectively. In addition, selected incurred samples were studied, obtaining several positive findings in pollen and nectar samples, demonstrating the sensitivity and applicability of the proposed method.
Asunto(s)
Insecticidas/análisis , Neonicotinoides/análisis , Néctar de las Plantas/análisis , Polen/química , Cromatografía Liquida , Espectrometría de Masas en TándemRESUMEN
The goal of this work was to evaluate the efficiency of several sorbents on removal fats from edible oils (olive, soya and sunflower) during the clean-up step for posterior determination of 165 pesticides by UHPLC-QqQ-MS/MS system. The extraction procedure employed in this work was the citrate version of QuEChERS method followed by a step of freezing out with dry ice and clean-up evaluation using i) PSA with magnesium sulfate (d-SPE); ii) magnesium sulfate and Z-sep sorbent (d-SPE); iii) Z-sep (column SPE) and iv) Agilent Bond Elut QuEChERS Enhanced Matrix Removal-Lipid (EMR-Lipid). After evaluation of the recovery results at 10, 20 and 50µgkg(-1), the EMR-Lipid showed important advantages comparing to the other sorbents evaluated, such as better recovery rates and RSD%. The method was validated at the three concentrations described above. Analytical curves linearity was evaluated by spiking blank oil samples at 10, 20, 50, 100 and 500µgkg(-1). The method demonstrated good recoveries values between the acceptable range of 70-120% and RSD%<20 for most of evaluated pesticides. In order to evaluate the performance of the method, this same procedure was employed to other oils such as soya and sunflower with very good results.