Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Reumatismo ; 73(2): 106-110, 2021 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-34342211

RESUMEN

The aim of this study was to evaluate the accuracy of synovial fluid analysis in the identification of calcium pyrophosphate dihydrate crystals compared to microscopic analysis of joint tissues as the reference standard. This is an ancillary study of an international, multicentre cross-sectional study performed by the calcium pyrophosphate deposition disease (CPPD) subgroup of the OMERACT Ultrasound working group. Consecutive patients with knee osteoarthritis (OA) waiting for total knee replacement surgery were enrolled in the study from 2 participating centres in Mexico and Romania. During the surgical procedures, synovial fluid, menisci and hyaline cartilage were collected and analysed within 48 hours from surgery under transmitted light microscopy and compensated polarised light microscopy for the presence/absence of calcium pyrophosphate crystals. All slides were analysed by expert examiners on site, blinded to other findings. A dichotomic score (absence/ presence) was used for scoring both synovial fluid and tissues. Microscopic analysis of knee tissues was considered the gold standard. Sensitivity, specificity, accuracy, positive and negative predictive values of synovial fluid analysis in the identification of calcium pyrophosphate crystals were calculated. 15 patients (53% female, mean age 68 yo ± 8.4) with OA of grade 3 or 4 according to Kellgren-Lawrence scoring were enrolled. 12 patients (80%) were positive for calcium pyrophosphate crystals at the synovial fluid analysis and 14 (93%) at the tissue microscopic analysis. The overall diagnostic accuracy of synovial fluid analysis compared with histology for CPPD was 87%, with a sensitivity of 86% and a specificity of 100%, the positive predictive value was 100% and the negative predictive value was 33%. In conclusion synovial fluid analysis proved to be an accurate test for the identification of calcium pyrophosphate dihydrate crystals in patients with advanced OA.


Asunto(s)
Condrocalcinosis , Osteoartritis de la Rodilla , Anciano , Pirofosfato de Calcio , Condrocalcinosis/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Masculino , Osteoartritis de la Rodilla/diagnóstico por imagen , Líquido Sinovial
3.
Ann Rheum Dis ; 76(1): 7-8, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27941072

RESUMEN

For over a decade, a large number of studies have highlighted the benefits of ultrasound (US) in the diagnosis and management of rheumatic diseases, especially rheumatoid arthritis (RA). However, its benefits in routine practice have been less studied and trials examining US as part of various clinical strategies are just emerging, with recent randomised trials examining the added value of US in tight-control paradigms. The conclusions of these trials have raised questions on the role of US in RA management. This Viewpoint analyses the recent studies, and discusses potential limitations in study designs as well as the methodological challenges of assessing the added value of an imaging technique.


Asunto(s)
Artritis Reumatoide , Ultrasonografía , Humanos , Enfermedades Reumáticas
4.
Ann Rheum Dis ; 75(2): 402-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25520476

RESUMEN

OBJECTIVE: Ultrasonography is sensitive for the evaluation of cartilage pathology and degree of osteophytes in patients with hand osteoarthritis (OA). High consistency of assessments is essential, and the OMERACT (Outcome Measures in Rheumatology) ultrasonography group took the initiative to explore the reliability of a global ultrasonography score in patients with hand OA using semiquantitative ultrasonography score of cartilage and osteophytes in finger joints. METHODS: Ten patients with hand OA were examined by 10 experienced sonographers over the course of two days. Semiquantitative scoring (0-3) was performed on osteophytes (carpo-metacarpal 1, metacarpo-phalangeal (MCP) 1-5, proximal interphalangeal 1-5 and distal interphalangeal 2-5 joints bilaterally with an ultrasonography atlas as reference) and cartilage pathology (MCP 2-5 bilaterally). A web-based exercise on static cartilage images was performed a month later. Reliability was assessed by use of weighted κ analyses. RESULTS: Osteophyte scores were evenly distributed, and the intraobserver and interobserver reliabilities were substantial to excellent (κ range 0.68-0.89 and mean κ 0.65 (day 1) and 0.67 (day 2), respectively). Cartilage scores were unevenly distributed, and the intraobserver and interobserver reliability was fair to moderate (κ range 0.46-0.66 and mean κ 0.39 (day 1) and 0.33 (day 2), respectively). The web-based exercise showed acceptable agreement for cartilage being normal (κ 0.47) or with complete loss (κ 0.68), but poor for the intermediate scores (κ 0.22-0.30). CONCLUSIONS: Use of the present semiquantitative ultrasonography scoring system for cartilage pathology in hand OA is not recommended (while normal or total loss of cartilage may be assessed). However, the OMERACT ultrasonography group will endorse the use of semiquantitative scoring of osteophytes with the ultrasonography atlas as reference.


Asunto(s)
Cartílago/diagnóstico por imagen , Articulaciones de los Dedos/diagnóstico por imagen , Mano/diagnóstico por imagen , Osteoartritis/diagnóstico por imagen , Osteofito/diagnóstico por imagen , Anciano , Cartílago/patología , Femenino , Articulaciones de los Dedos/patología , Mano/patología , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Osteoartritis/patología , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Ultrasonografía
5.
Ann Rheum Dis ; 74(11): 1946-57, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26245755

RESUMEN

To develop evidence based points to consider the use of imaging in the diagnosis and management of juvenile idiopathic arthritis (JIA) in clinical practice. The task force comprised a group of paediatric rheumatologists, rheumatologists experienced in imaging, radiologists, methodologists and patients from nine countries. Eleven questions on imaging in JIA were generated using a process of discussion and consensus. Research evidence was searched systematically for each question using MEDLINE, EMBASE and Cochrane CENTRAL. Imaging modalities included were conventional radiography, ultrasound, MRI, CT, scintigraphy and positron emission tomography. The experts used the evidence obtained from the relevant studies to develop a set of points to consider. The level of agreement with each point to consider was assessed using a numerical rating scale. A total of 13 277 references were identified from the search process, from which 204 studies were included in the systematic review. Nine points to consider were produced, taking into account the heterogeneity of JIA, the lack of normative data and consequent difficulty identifying pathology. These encompassed the role of imaging in making a diagnosis of JIA, detecting and monitoring inflammation and damage, predicting outcome and response to treatment, use of guided therapies, progression and remission. Level of agreement for each proposition varied according to the research evidence and expert opinion. Nine points to consider and a related research agenda for the role of imaging in the management of JIA were developed using published evidence and expert opinion.


Asunto(s)
Artritis Juvenil/diagnóstico , Articulaciones , Adolescente , Comités Consultivos , Artritis Juvenil/terapia , Niño , Preescolar , Manejo de la Enfermedad , Humanos , Articulaciones/diagnóstico por imagen , Articulaciones/patología , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Radiografía , Cintigrafía , Reumatología , Tomografía Computarizada por Rayos X , Ultrasonografía
6.
Ann Rheum Dis ; 74(3): 611-7, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24336336

RESUMEN

OBJECTIVE: To determine the tolerability, safety and yield of synovial tissue in an early arthritis cohort using a minimally invasive, ultrasound (US)-guided, synovial biopsy technique in small, medium and large joints. METHODS: 93 sequential biopsy procedures were assessed from a total of 57 patients (baseline and 36 repeat biopsies at 6 months) recruited as part of the 'Pathobiology of Early Arthritis Cohort' study. Patients completed a tolerability questionnaire prior to and following the synovial biopsy procedure. The synovial biopsy was performed under US guidance with US images of the joint recorded prior to each procedure. Synovial tissue was harvested for immunohistochemistry and RNA extraction. RESULTS: Five different joint sites were biopsied (knee, elbow, wrist, metacarpal phalangeal and proximal interphalangeal). No significant complications were reported following the procedure. No difference in pain, swelling and stiffness of the biopsied joint from before and after the procedure was demonstrated. A median of 14 biopsy samples was retrieved from each procedure with 93% of biopsy procedures yielding good quality tissue. RNA yield was good in all joints and in repeat biopsies. Multivariant analysis demonstrated a significantly greater yield of RNA and graded tissue in relation to a high prebiopsy, grey-scale synovitis score (0-3, semiquantitative). CONCLUSIONS: A minimally invasive approach to synovial tissue harvesting, using US guidance, is both safe and well-tolerated by patients. Tissue quality/RNA yield is preserved in subsequent biopsies following therapeutic intervention. A high US grey-scale synovitis score is a predictor of good quality/quantity of tissue and RNA.


Asunto(s)
Artritis Reumatoide/patología , Articulación del Codo/patología , Articulaciones de la Mano/patología , Biopsia Guiada por Imagen , Articulación de la Rodilla/patología , ARN/análisis , Membrana Sinovial/patología , Sinovitis/patología , Adulto , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/metabolismo , Estudios de Cohortes , Articulación del Codo/diagnóstico por imagen , Femenino , Articulaciones de la Mano/diagnóstico por imagen , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Membrana Sinovial/diagnóstico por imagen , Membrana Sinovial/metabolismo , Sinovitis/diagnóstico por imagen , Sinovitis/metabolismo , Ultrasonografía
7.
Ann Rheum Dis ; 74(7): 1327-39, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25837448

RESUMEN

A taskforce comprised of an expert group of 21 rheumatologists, radiologists and methodologists from 11 countries developed evidence-based recommendations on the use of imaging in the clinical management of both axial and peripheral spondyloarthritis (SpA). Twelve key questions on the role of imaging in SpA were generated using a process of discussion and consensus. Imaging modalities included conventional radiography, ultrasound, magnetic resonance imaging, computed tomography (CT), positron emission tomography, single photon emission CT, dual-emission x-ray absorptiometry and scintigraphy. Experts applied research evidence obtained from systematic literature reviews using MEDLINE and EMBASE to develop a set of 10 recommendations. The strength of recommendations (SOR) was assessed by taskforce members using a visual analogue scale. A total of 7550 references were identified in the search process, from which 158 studies were included in the systematic review. Ten recommendations were produced using research-based evidence and expert opinion encompassing the role of imaging in making a diagnosis of axial SpA or peripheral SpA, monitoring inflammation and damage, predicting outcome, response to treatment, and detecting spinal fractures and osteoporosis. The SOR for each recommendation was generally very high (range 8.9-9.5). These are the first recommendations which encompass the entire spectrum of SpA and evaluate the full role of all commonly used imaging modalities. We aimed to produce recommendations that are practical and valuable in daily practice for rheumatologists, radiologists and general practitioners.


Asunto(s)
Diagnóstico por Imagen/métodos , Espondiloartritis/diagnóstico , Espondiloartritis/terapia , Europa (Continente) , Humanos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Radiografía , Espondiloartritis/clasificación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía
8.
Arthritis Rheum ; 64(4): 1272-82, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22131049

RESUMEN

OBJECTIVE: To evaluate the intraobserver reliability, face validity, and discriminant capacity of different global ultrasound (US) scoring systems for measuring synovitis in rheumatoid arthritis (RA). METHODS: This study was ancillary to a 52-week, multicenter, prospective, randomized, open-label, parallel-group outpatient study conducted in patients with moderate RA who were randomized to receive either etanercept combined with methotrexate or various disease-modifying antirheumatic drugs. A total of 66 different synovitis scoring systems were constructed and evaluated, including 11 different joint combinations; data derived from clinical findings, gray-scale US, and power Doppler US (PDUS); and both binary counts and semiquantitative scores. RESULTS: Due to discontinuation of the trial, only 62 patients, a subset of the initially planned number of patients, were included in this study. Reliability was found to be better for gray-scale US and PDUS than for clinical evaluation of synovitis in patients with stable disease between the screening and baseline visits (range for intraclass correlation coefficient 0.6, 0.95 for gray-scale US and 0.56, 0.93 for PDUS versus 0.31, 0.75 for clinical indices). The median (range) difference in the discriminant capacities of clinical indices versus gray-scale US and versus PDUS was 0.25 (-0.64, 0.96) and -0.025 (-0.59, 0.53), respectively, in the period from baseline to 12 weeks. No relevant differences in metrologic properties were observed regarding the number and composition of joints between the different scoring systems. Our findings suggested that a simplified scoring system referring to gray-scale US and PDUS findings might be sufficient. CONCLUSION: Our findings indicate that gray-scale US and PDUS have better reliability than generally used clinical indices for evaluating synovitis in RA. PDUS has at least as good discriminant capacity as clinical assessment of synovitis for distinguishing between treatment arms.


Asunto(s)
Artritis Reumatoide/complicaciones , Articulaciones/diagnóstico por imagen , Sinovitis/diagnóstico , Adulto , Anciano , Antirreumáticos/uso terapéutico , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sinovitis/complicaciones , Sinovitis/diagnóstico por imagen , Resultado del Tratamiento , Ultrasonografía
9.
Ultraschall Med ; 34(5): 475-7, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23696065

RESUMEN

In order to optimize and standardize musculoskeletal ultrasonography education for rheumatologists, there is a need for competency assessments addressing the required training and practical and theoretical skills. This paper describes how these competency assessments for rheumatologists were developed and what they contain.


Asunto(s)
Competencia Clínica , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Reumatología/educación , Sociedades Médicas , Ultrasonografía/normas , Comparación Transcultural , Curriculum/normas , Europa (Continente) , Humanos , Consejos de Especialidades
10.
Osteoarthritis Cartilage ; 20(10): 1142-6, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22800773

RESUMEN

OBJECTIVE: To assess the reliability of ultrasound (US) in detecting cartilage abnormalities at the metacarpo-phalangeal (MCP) joints in people with cartilage pathology. METHODS: Nine expert ultrasonographers initially achieved consensus on definitions and scanning protocols. They then examined the second to fifth MCP joints of the dominant hand of eight people with hand osteoarthritis (OA). US examinations were conducted in two rounds, with independent blinded evaluations of cartilage lesions. Global cartilage abnormalities were assessed by applying a dichotomous (presence/absence) score; in addition, the following lesions were evaluated using the same scoring system: loss of anechoic structure and/or thinning of the cartilage layer, and irregularities and/or loss of sharpness of at least one cartilage margin. Reliability was assessed using kappa (k) coefficients. RESULTS: Thirty-two joints were examined. Intra-observer k values ranged from 0.52 to 1 for global cartilage abnormalities; k values ranged from 0.54 to 0.94 for loss of anechoic structure and/or thinning of cartilage layer and from 0.59 to 1 for irregularities and/or loss of sharpness of at least one cartilage margin. Values of k for inter-observer reliability were 0.80 for global cartilage abnormalities, 0.62 for loss of anechoic structure and/or thinning of cartilage layer, and 0.39 for irregularities and/or loss of sharpness of at least one cartilage margin. CONCLUSION: US is a reliable imaging modality for the detection of cartilage abnormalities in patients with cartilage pathology in the MCP joints. The analysis of specific cartilage measures showed more variable results that may be improved by modifying definitions and further standardization of US techniques.


Asunto(s)
Enfermedades de los Cartílagos/diagnóstico por imagen , Enfermedades de los Cartílagos/patología , Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Articulación Metacarpofalángica/diagnóstico por imagen , Articulación Metacarpofalángica/patología , Anciano , Técnica Delphi , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Ultrasonografía
11.
Ultraschall Med ; 33(7): E173-E178, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22194046

RESUMEN

PURPOSE: To investigate which knee and probe position best identifies knee inflammation and to determine a cut-off level for abnormal synovial effusion. MATERIALS AND METHODS: 18 experienced sonographers (all rheumatologists) performed ultrasound examinations of the knee joint in patients with knee symptoms and in healthy controls. Each sonographer performed longitudinal suprapatellar ultrasound scans using 9 different configurations at each knee: Midline, parapatallar lateral and parapatellar medial from midline in neutral position (0°) with and without quadriceps muscle contraction and in 30° flexion of the knee. The presence of synovial effusion (SE), the effusion measured in millimeters and the presence of synovial hypertrophy (SH) was noted. RESULTS: A total of 298 knees of 149 subjects (129 patients and 20 controls) were examined. The detection of SH is more sensitive and specific than the detection of SE, independently of the knee and probe position, for the final diagnosis of abnormality. The detection of both synovial hypertrophy and effusion in the knee in neutral position (0°) with quadriceps contraction and with the probe in the midline position, are the best independent predictors for knee abnormalities. Knee effusion > 3.2 mm measured with the probe in the lateral aspect of the knee is the best diagnostic characteristics for predicting pathological SE. CONCLUSION: The best combination for detecting SH and SE is obtained by placing the probe in the midline position with the knee in 0° with quadriceps contraction. A cut-off value for pathological effusion may be obtained in the lateral aspect of the knee.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Artritis/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico por imagen , Posicionamiento del Paciente , Líquido Sinovial/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hipertrofia , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Rótula/diagnóstico por imagen , Rango del Movimiento Articular/fisiología , Valores de Referencia , Sensibilidad y Especificidad , Membrana Sinovial/diagnóstico por imagen , Membrana Sinovial/patología , Ultrasonografía , Adulto Joven
12.
Semin Arthritis Rheum ; 51(3): 627-639, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33810864

RESUMEN

OBJECTIVES: To identify and synthesize the evidence for the use and measurement properties of musculoskeletal ultrasound in assessing structural joint damage in patients with rheumatoid arthritis (RA). METHODS: A systematic literature search (SLR) of the PubMed, Embase and Cochrane Library was performed. Original articles were included published in English reporting on ultrasound of bone erosion, cartilage damage and the measurement properties of ultrasound according to the OMERACT filter 2.1. RESULTS: Of the 1.495 identified articles 149 were included in the final review, most of which reported on cross-sectional studies and used the OMERACT definitions for ultrasonographic pathology. Among these, bone erosions were assessed in 139 (93.3%), cartilage damage in 24 (16.1%), enthesophytes in 8 (5.4%), osteophytes in 15 (10.1%) and malalignment and ankylosis in a single (0.9%) study, respectively. Most studies (126/149, 84.6%) assessed the joints of the hands. The overwhelming majority of studies (127/149, 85.2%) assessed structural joint damage bilaterally. Validity, reliability and responsiveness were assessed in 21 (14.1%), 34 (22.8%) and 17 (11.4%) studies, respectively. CONCLUSION: While the results of this SLR suggest that ultrasound is a sensitive, reliable and feasible tool to detect damage in RA, they also highlight the need for further research and validation. Findings of this SLR will inform the next steps of the OMERACT Ultrasound Working Group in developing an ultrasound score for assessing structural joint damage in patients with RA.


Asunto(s)
Artritis Reumatoide , Artritis Reumatoide/diagnóstico por imagen , Estudios Transversales , Humanos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Ultrasonografía
13.
Ann Rheum Dis ; 69(4): 644-7, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19433410

RESUMEN

OBJECTIVES: To determine clinical and ultrasonographic predictors of joint replacement surgery across Europe in primary osteoarthritis (OA) of the knee. METHODS: This was a 3-year prospective study of a painful OA knee cohort (from a EULAR-sponsored, multicentre study). All subjects had clinical evaluation, radiographs and ultrasonography (US) at study entry. The rate of knee replacement surgery over the 3-year follow-up period was determined using Kaplan-Meier survival data analyses. Predictive factors for joint replacement were identified by univariate log-rank test then multivariate analysis using a Cox proportional-hazards regression model. Potential baseline predictors included demographic, clinical, radiographic and US features. RESULTS: Of the 600 original patients, 531 (88.5%), mean age 67+/-10 years, mean disease duration 6.1+/-6.9 years, had follow-up data and were analysed. During follow-up (median 3 years; range 0-4 years), knee replacement was done or required for 94 patients (estimated event rate of 17.7%). In the multivariate analysis, predictors of joint replacement were as follows: Kellgren and Lawrence radiographic grade (grade > or =III vs or =4 mm vs <4 mm) (HR = 2.63 (95% CI 1.70 to 4.06), p<0.0001); knee pain intensity on a 0-100 mm visual analogue scale (> or =60 vs <60) (HR = 1.81 (95% CI 1.15 to 2.83), p=0.01) and disease duration (> or =5 years vs <5 years) (HR=1.63 (95% CI 1.08 to 2.47), p=0.02). Clinically detected effusion and US synovitis were not associated with joint replacement in the univariate analysis. CONCLUSION: Longitudinal evaluation of this OA cohort demonstrated significant progression to joint replacement. In addition to severity of radiographic damage and pain, US-detected effusion was a predictor of subsequent joint replacement.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla/cirugía , Anciano , Progresión de la Enfermedad , Métodos Epidemiológicos , Exudados y Transudados/diagnóstico por imagen , Femenino , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Dimensión del Dolor , Pronóstico , Radiografía , Ultrasonografía
14.
Ann Rheum Dis ; 68(4): 502-7, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18413442

RESUMEN

OBJECTIVE: To examine the recurrence of manifestations belonging to the spectrum of spondylarthropathy (SpA) in first-degree relatives of patients with SpA, and to estimate the recurrence risk ratio. METHODS: Parents and siblings of consecutive SpA probands have been thoroughly investigated, including clinical data collection, pelvic x ray and human leukocyte antigen (HLA)-B27 status determination. The diagnosis of SpA was made according to European Spondylarthropathy Study Group and/or the Amor criteria. The recurrence risk ratio lambda(1), which gives an estimate of the weight of genetic factors, was calculated as the ratio of the recurrence risk of SpA in first-degree relatives compared with the population prevalence of SpA. The lambda(non-HLA) was obtained by similar calculations restricted to HLA-B27+ individuals. RESULTS: Most manifestations of SpA were more frequent among the 157 HLA-B27+ relatives of 83 probands than among their 111 HLA-B27- relatives. A diagnosis of SpA was made in 50 relatives of 31 (37%) probands. Recurrence was very similar between parents and siblings, without gender difference, resulting in overall recurrence risk of 12% in first-degree relatives and of 22.7% in HLA-B27+ relatives. The lambda(1) value was 40 and the lambda(non-HLA) value was 6.5, very close to the lambda(HLA) value of 6.25 estimated from linkage study in SpA. CONCLUSIONS: A similar recurrence risk of SpA was observed between parents and siblings, consistent with a model of inheritance with no dominance variance and without sex influence. The weight of the non-HLA genetic component was equivalent to that estimated for the HLA locus, and fitted a model of multiplicative interaction between HLA and non-HLA genetic components.


Asunto(s)
Padres , Hermanos , Espondiloartropatías/genética , Adulto , Anciano , Estudios Transversales , Femenino , Francia , Antígeno HLA-B27/genética , Prueba de Histocompatibilidad , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Recurrencia , Factores Sexuales
15.
Ann Rheum Dis ; 68(3): 357-61, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18390570

RESUMEN

OBJECTIVE: To assess the intra and interobserver reproducibility of musculoskeletal ultrasonography (US) among rheumatologists in detecting destructive and inflammatory shoulder abnormalities in patients with rheumatoid arthritis (RA) and to determine the overall agreement between US and MRI. METHODS: A total of 14 observers examined 5 patients in 2 rounds independently and blindly of each other. US results were compared with MRI. Overall agreement of all findings, of positive findings on MRI, as well as intra and interobserver reliabilities, were calculated. RESULTS: Overall agreement between US and MRI was seen in 79% with regard to humeral head erosions (HHE), in 64% with regard to posterior recess synovitis (PRS), in 31% with regard to axillary recess synovitis (ARS), in 64% with regard to bursitis, in 50% with regard to biceps tenosynovitis (BT), and in 84% for complete cuff tear (CCT). Intraobserver and interobserver kappa was 0.69 and 0.43 for HHE, 0.29 and 0.49 for PRS, 0.57 and 1.00 for ARS, -0.17 and 0.51 for bursitis, 0.17 and 0.46 for BT and 0.52 and 0.6 for CCT, respectively. The intraobserver and interobserver kappa for power Doppler (PD) was 0.90 and 0.70 for glenohumeral signals and 0.60 and 0.51 for bursal signals, respectively. CONCLUSIONS: US is a reliable imaging technique for most shoulder pathology in RA especially with regard to PD. Standardisation of scanning technique and definitions of particular lesions may further enhance the reliability of US investigation of the shoulder.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Anciano , Artritis Reumatoide/diagnóstico , Bursitis/diagnóstico , Bursitis/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sinovitis/diagnóstico , Sinovitis/diagnóstico por imagen , Tenosinovitis/diagnóstico , Tenosinovitis/diagnóstico por imagen , Ultrasonografía
16.
J Cell Biol ; 71(3): 781-94, 1976 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-186463

RESUMEN

In chick-embryo fibroblasts infected with the Schmidt-Ruppin strain of Rous sarcoma virus, subgroup A (wild type), or with a thermosensitive mutant of this virus, T5, the rates of mitochondrial DNA synthesis differ in cells that exhibit normal and malignant phenotypes. In wild type virus-infected cells grown at 36 or 41 degrees C, morphological transformation is expressed, the rate of 2-deoxy-D-[3H]glucose uptake is stimulated, and mitochondrial DNA synthesis in vivo is stimulated three- to fivefold over that in uninfected cells. In T5-infected cells these changes occur only at the permissive temperature (36 degrees C); a shift to the nonpermissive temperature (41 degrees C) causes the reversal of these effects, and the specific activity of purified mitochondrial DNA is characteristic of that from uninfected cells. In contrast, the specific activities of nuclear DNA purified from cells maximally transformed under the permissive conditions do not differ between wild type-infected and uninfected with the T5 virus. In parallel experiments with isolated mitochondria, the rate of mtDNA synthesis in vitro is again greater in mitochondria isolated from transformed cells. In addition, mitochondrial DNA synthesis in vitro in mitochondria from nontransformed and virus-transformed cells exhibits differential sensitivity to inhibition by mercaptoethanol. Furthermore, the ntDNAP polymerase activity in mitochondrial extracts prepared from cells with transformed phenotypes is about sevenfold higher than in extracts from cells with nontransformed phenotypes.


Asunto(s)
Transformación Celular Neoplásica , ADN Mitocondrial/biosíntesis , Virus del Sarcoma Aviar , División Celular , Línea Celular , Supervivencia Celular , ADN Polimerasa Dirigida por ADN/metabolismo , Desoxiglucosa/metabolismo , Mitocondrias/enzimología , Proteínas/análisis
17.
Clin Exp Rheumatol ; 27(4 Suppl 55): S50-5, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19822046

RESUMEN

Enthesitis is a distinctive pathological feature of spondyloarthritis and may involve synovial joints, fibrocartilaginous joints, syndesmoses and extra-articular entheses. Extra-articular pain may often be present in rheumatoid arthritis patients. This review focuses on peripheral enthesitis which is a clinical hallmark of spondylarthritis, by comparing the same findings in rheumatoid arthritis.


Asunto(s)
Artritis Reumatoide/patología , Cápsula Articular/patología , Espondilitis Anquilosante/patología , Artritis Reumatoide/complicaciones , Artrografía , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Espondilitis Anquilosante/complicaciones , Ultrasonografía Doppler
18.
J Radiol ; 90(1 Pt 2): 148-55, 2009 Jan.
Artículo en Francés | MEDLINE | ID: mdl-19212282

RESUMEN

Contrast-enhanced US (ultrasonography) can be used for the study of musculoskeletal diseases but this application still belongs to clinical research. Despite a theoretical value for the identification of microvascularity, the technical limitations of musculoskeletal US are challenging the use of contrast enhanced US. This can explain the slow development of this application and the reason why it remained limited to the assessment of Doppler signal intensity increase. However, the recent availability of real time contrast-enhanced US imaging and quantification data is very promising. The majority of published papers involves rheumatoid arthritis and demonstrates the value of this technique to improve diagnosis, stage the activity of the disease and follow the patients under therapy. These preliminary studies are extending to other disorders (inflammatory arthritides as well as degenerative disorders). Structures other than articular synovium are undergoing investigations (bone, enthesis). New applications are being developed such as contrast-enhanced US of muscular diseases. This new imaging technique appears to have great potentials for the assessment of musculoskeletal diseases.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Medios de Contraste , Dermatomiositis/diagnóstico por imagen , Fibromialgia/diagnóstico por imagen , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico por imagen , Espondiloartropatías/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Artritis Juvenil/diagnóstico , Artritis Juvenil/diagnóstico por imagen , Artritis Reumatoide/diagnóstico , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Microburbujas , Persona de Mediana Edad , Enfermedades Musculoesqueléticas/diagnóstico , Osteoartritis de la Rodilla/diagnóstico , Fosfolípidos , Polisacáridos , Sensibilidad y Especificidad , Hexafluoruro de Azufre , Ultrasonografía Doppler/métodos
19.
Ann Rheum Dis ; 67(5): 651-5, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-17704062

RESUMEN

OBJECTIVES: Painful osteoarthritis (OA) of the hand is common and a validated ultrasound (US) scoring system would be valuable for epidemiological and therapeutic outcome studies. US is increasingly used to assess peripheral joints, though most of the US focus in rheumatic diseases has been on rheumatoid arthritis. We aimed to develop a preliminary US hand OA scoring system, initially focusing on relevant pathological features with potentially high reliability. METHODS: A group of experts in the fields of OA, US and novel tool development agreed on domains and suggested scaling of the items to be used in US hand OA scoring systems. A multi-observer reliability exercise was then performed to evaluate the draft items. RESULTS: Synovitis (grey scale and Power Doppler) and osteophytes (representing activity and damage domains) were included and evaluated as the initial components of the scoring system. All three features were evaluated for their presence/absence and if present were scored using a 1-3 scale. The reliability exercise demonstrated intra-reader kappa values of 0.444-1.0, 0.211-1.0 and 0.087-1.0 for grey scale synovitis, power Doppler and osteophytes respectively. Inter-reader reliability kappa values were 0.398, 0.327 and 0.530 grey-scale synovitis, power Doppler and osteophytes respectively. Without extensive standardisation, both intra- and inter-reader reliability were moderately good. CONCLUSIONS: The draft scoring system demonstrated substantive to almost perfect percentage exact agreement on the presence/absence of the selected OA features and moderate to substantive percentage exact agreement on semi-quantitative grading. This preliminary process provides a good basis from which to further develop an US outcome tool for hand OA that has the potential to be utilised in multicentre clinical trials.


Asunto(s)
Articulaciones de la Mano/diagnóstico por imagen , Indicadores de Salud , Osteoartritis/diagnóstico por imagen , Articulaciones de la Mano/fisiopatología , Humanos , Variaciones Dependientes del Observador , Osteoartritis/fisiopatología , Osteofito/diagnóstico por imagen , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Sinovitis/diagnóstico por imagen , Sinovitis/fisiopatología , Ultrasonografía Doppler
20.
Ann Rheum Dis ; 67(7): 1017-22, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17921183

RESUMEN

OBJECTIVE: To develop education guidelines for the conduct of future European League Against Rheumatism (EULAR) musculoskeletal ultrasound (MSUS) courses. METHODS: We undertook a consensus-based, iterative process using two consecutive questionnaires sent to 29 senior ultrasonographer rheumatologists who comprised the faculty of the 14th EULAR ultrasound course (June 2007). The first questionnaire encompassed the following issues: type of MSUS educational model; course timing; course curriculum; course duration; number of participants per teacher in practical sessions; time spent on hands-on sessions; and the requirements and/or restrictions for attendance at the courses. The second questionnaire consisted of questions related to areas where consensus had not been achieved in the first questionnaire, and to the topics and pathologies to be assigned to different educational levels. RESULTS: The response rate was 82.7% from the first questionnaire and 87.5% from the second questionnaire. The respondents were from 11 European countries. The group consensus on guidelines and curriculum was for a three-level education model (basic, intermediate and advanced) with timing and location related to the annual EULAR Congresses. The topics and pathologies to be included in each course were agreed. The course duration will be 20 h. There will be a maximum of six participants per teacher and 50-60% of total time will be spent on practical sessions. There was also agreement on prerequisite experience before attending the intermediate and advanced courses. CONCLUSION: We have developed European agreed guidelines for the content and conduct of EULAR ultrasound courses, which may also be recommended to national and local MSUS training programmes.


Asunto(s)
Educación Médica/organización & administración , Enfermedades Musculoesqueléticas/diagnóstico por imagen , Radiología/educación , Reumatología/educación , Actitud del Personal de Salud , Curriculum , Educación Médica/normas , Europa (Continente) , Humanos , Cooperación Internacional , Modelos Educacionales , Encuestas y Cuestionarios , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA