1.
Pacing Clin Electrophysiol ; 26(1P2): 466-70, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12687869

RESUMEN

Morphology Discrimination is a discriminator based on QRS morphology analysis that has been recently implemented in dual chamber implantable cardioverter defibrillators (ICDs). Detected events are initially classified according to median atrial and ventricular rates (Rate Branch). Then, a series of discriminators (Morphology Discrimination, Stability, Sudden Onset) analyze the rhythm according to specific criteria and the number of discriminators required for VT diagnosis (i.e., requiring "any" or "all" of the specific discriminators to indicate VT). The discriminating accuracy of the algorithm was evaluated in 645 detections recorded during the follow-up of 25 patients. The overall specificity for 397 supraventricular arrhythmias was 73.5% (292/397) with the tachycardia diagnosis criteria set to "any" and 90.9% (361/397) with the tachycardia diagnosis criteria set to "all." Sensitivity for VT was 100% and 98.7% (231/234) with the tachycardia diagnosis criteria set to "any" and "all," respectively. With the tachycardia diagnosis criteria set to "any," specificity for atrial fibrillation was 88.6%, for atrial flutter 40.3%, for atrial tachycardia 0%, and for sinus tachycardia 97.0%. With the tachycardia diagnosis criteria set to "all," specificity for atrial fibrillation was 92.40%, for atrial flutter 93.5%, for atrial tachycardia 54.7%, and for sinus tachycardia 99.0%. The contribution of Morphology Discrimination was crucial to improve the specificity of the Rate Branch algorithm. The implementation of Morphology Discrimination in a dual chamber ICD with Rate Branch rhythm classification allows the attainment of high specificity and high sensitivity for ventricular tachyarrhythmias.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Desfibriladores Implantables , Electrocardiografía , Anciano , Fibrilación Atrial/diagnóstico , Aleteo Atrial/diagnóstico , Femenino , Humanos , Masculino , Sensibilidad y Especificidad , Taquicardia Ventricular/diagnóstico
2.
Pacing Clin Electrophysiol ; 25(9): 1357-66, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12380773

RESUMEN

Morphology Discrimination (MD) is a rhythm discriminator based on QRS morphology analysis that can be combined with other discriminators like Stability, with or without Sinus Interval History (SIH) and Sudden Onset. Thirty-five patients implanted with a St. Jude Medical single chamber ICD were evaluated during exercise testing, during induced AF, and during follow-up for 14 +/- 5 months. At exercise testing (60 episodes detected) MD had a specificity (SP) of 96.7% and Sudden Onset a SP of 91.7%; during induced AF (25 episodes) both MD and Stability had a SP of 96.0%. The diagnostic performance on spontaneous arrhythmias was as follows: for ventricular tachycardia (126 episodes) a sensitivity (SE) of 94.4% for MD, 92.1% for Sudden Onset, 89.7% for Stability without SIH and 79.4% for Stability + SIH; for sinus tachycardia (44 episodes) a SP of 86.4% for MD, 97.7% for Sudden Onset, 2.3% for Stability and of 95.5% for Stability + SIH. For AF (165 cases) a SP of 67.9% for MD, 69.1% for Stability and 90.3% for Stability + SIH, 44.8% for Sudden Onset. Use of MD alone provided a SE of 94.4% and a SP of 71.4% for spontaneous arrhythmias and combined use of the discriminators in a "2 of 3" diagnostic logic implied a SP of 90.9% with maintenance of 96.0% of SE. In single chamber ICDs a wide range of SE/SP ratios may be obtained by use of multiple discriminators, but use of the algorithm in a 2 of 3 diagnostic logic may achieve a SP of 90.9% and a SE of 96.0%.


Asunto(s)
Algoritmos , Desfibriladores Implantables , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Diseño de Equipo , Prueba de Esfuerzo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Factores de Tiempo