Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Nat Methods ; 14(8): 805-810, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28628129

RESUMEN

We report a method for serial X-ray crystallography at X-ray free-electron lasers (XFELs), which allows for full use of the current 120-Hz repetition rate of the Linear Coherent Light Source (LCLS). Using a micropatterned silicon chip in combination with the high-speed Roadrunner goniometer for sample delivery, we were able to determine the crystal structures of the picornavirus bovine enterovirus 2 (BEV2) and the cytoplasmic polyhedrosis virus type 18 polyhedrin, with total data collection times of less than 14 and 10 min, respectively. Our method requires only micrograms of sample and should therefore broaden the applicability of serial femtosecond crystallography to challenging projects for which only limited sample amounts are available. By synchronizing the sample exchange to the XFEL repetition rate, our method allows for most efficient use of the limited beam time available at XFELs and should enable a substantial increase in sample throughput at these facilities.


Asunto(s)
Algoritmos , Cristalografía por Rayos X/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Virus/ultraestructura , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad
2.
J Synchrotron Radiat ; 24(Pt 6): 1180-1186, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-29091061

RESUMEN

A method for measuring resonant inelastic X-ray scattering based on the conversion of X-ray photons into photoelectrons is presented. The setup is compact, relies on commercially available detectors, and offers significant flexibility. This method is demonstrated at the Linac Coherent Light Source with ∼0.5 eV resolution at the cobalt L3-edge, with signal rates comparable with traditional grating spectrometers.

3.
J Synchrotron Radiat ; 22(3): 508-13, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931061

RESUMEN

The X-ray Correlation Spectroscopy instrument is dedicated to the study of dynamics in condensed matter systems using the unique coherence properties of free-electron lasers. It covers a photon energy range of 4-25 keV. The intrinsic temporal characteristics of the Linac Coherent Light Source, in particular the 120 Hz repetition rate, allow for the investigation of slow dynamics (milliseconds) by means of X-ray photon correlation spectroscopy. Double-pulse schemes could probe dynamics on the picosecond timescale. A description of the instrument capabilities and recent achievements is presented.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA