Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Acta Oncol ; 62(10): 1178-1183, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37850713

RESUMEN

BACKGROUND: In this study we present the Tracking Accessory 3 (TA3) as an alternative to the commercial gating block (GB) surrogate for the Varian Truebeam™ gating system (TGS). The TGS requires three visible reflectors to track the surrogate, presenting an opportunity for a surrogate to be made with less material and thus smaller dosimetric footprint than the commercial four reflector model. MATERIALS AND METHODS: Relative dose and depth dose profiles below the TA3 and the GB were measured with radiosensitive film. Accuracy and reproducibility of the detected motion amplitude for three TA3s and one GB were determined using a respiratory phantom with surrogate to determine the camera's tracking volume. Clinical performance was evaluated prospectively in 10 breast cancer patients treated with deep inspiration breath hold monitored with TA3 and compared to previously published results. Non-parametric statistics were applied to test for significance. RESULTS AND CONCLUSIONS: Surface doses were increased up to 94% and 187% for the TA3 and GB, respectively, compared to no surrogate. The surface area influenced by at least 25% increase in dose was 12 cm2 and 105 cm2 for the TA3 and GB, respectively. The water equivalent thickness of the surrogates was found to be 1 mm for the TA3 and 3 mm for GB. The difference in measured amplitude were <0.2 mm for TA3 compared to the GB. The TA3s and GB were detected at all extremes of the clinically relevant tracking volume of the TGS. Clinical performance showed no significant differences. The TA3 caused less surface dose increase compared to the commercial GB. In the tested range all surrogates measured motion amplitude within 0.2 mm of reference value, which is not a clinically relevant difference. The TA3 showed no significant differences in clinical performance to similarly positioned surrogates.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Reproducibilidad de los Resultados , Movimiento (Física) , Carbono , Planificación de la Radioterapia Asistida por Computador/métodos
2.
J Appl Clin Med Phys ; 20(6): 39-44, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31187538

RESUMEN

Surface Guided Radiotherapy (SGRT) is a relatively new technique for positioning patients and for monitoring patient movement during treatment. SGRT is completely non-invasive since it uses visible light for determining the position of the patient surface. A reduction in daily imaging for patient setup is possible if the accuracy of SGRT is comparable to imaging. It allows for monitoring of intrafraction motion and the radiation beam can be held beyond a certain threshold resulting in a more accurate irradiation. The purpose of this study was to investigate setup uncertainty and the intrafraction motion in non-gated whole breast cancer radiotherapy treatment using an integrated implementation of AlignRT (OSMS) system as SGRT. In initial setup, SGRT was compared to three-point setup using tattoos on the patient and orthogonal kV imaging. For the investigation of intrafraction motion, OSMS monitored the patient with six degrees of freedom during treatment. Using three-point setup resulted in a setup root-mean-square error from the isocenter of 5.4 mm. This was improved to 4.2 mm using OSMS. For the translational directions, OSMS showed improvements in the lateral direction (P = 0.0009, Wilcoxon rank-sum), but for the longitudinal direction and rotation it was not possible to show improvements (P = 0.96 and P = 0.46, respectively). The vertical direction proved more accurate for three-point setup than OSMS (P = 0.000004). Intrafraction motion was very limited with a translational median of 1.1 mm from the isocenter. While OSMS showed marked improvements over laser and tattoo setup, the system did not prove accurate enough to replace the daily orthogonal kV images aligned to bony anatomy.


Asunto(s)
Neoplasias de la Mama/radioterapia , Posicionamiento del Paciente , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control , Radioterapia Guiada por Imagen/métodos , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Inmovilización , Persona de Mediana Edad , Movimiento , Pronóstico , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Respiración
3.
Acta Oncol ; 56(6): 799-805, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28293971

RESUMEN

BACKGROUND: Pre-treatment magnetic resonance imaging (MRI) can give patient-specific evaluation of suspected pathologically involved volumes in the seminal vesicles (SV) in prostate cancer patients. By targeting this suspicious volume we hypothesize that radiotherapy is more efficient without introducing more toxicity. In this study we evaluate the concept of using MRI-defined target volumes in terms of tumor control probability (TCP) and rectal normal tissue complication probability (NTCP). MATERIAL AND METHODS: Twenty-one high-risk prostate cancer patients were included. Pre-treatment CT images, T2 weighted (T2w) MRI and two multi-parametric MRI were acquired. Overlap between a suspicious volume in the SV observed on T2w images and a suspicious volume observed on either multi-parametric MRI was assumed to reflect a true malignant region (named 'MRI positive'). In addition the entire SV on the CT-scan was delineated. Three treatment plans of 2 Gy ×39 fractions were generated per patient: one covering the MRI positive volume in SV and prostate with margin of 11 mm to the MRI positive in the SV and two plans covering prostate and SV using 11 and 7 mm SV margin, respectively. All plans were prescribed the same PTV mean dose. Rectal NTCP grade ≥2 was evaluated with the Lyman-Kutcher-Burman model and TCP was estimated by a logistic model using the combined MRI positive volume in SV and prostate as region-of-interest. RESULTS: Fourteen of twenty-one patients were classified as MRI positive, six of which had suspicious volumes in all three MRI modalities. On average TCP for the plan covering prostate and the MRI positive volume was 3% higher (up to 11%) than the two other plans which was statistically significant. The increased TCP was obtained without increasing rectal NTCP grade ≥2. CONCLUSIONS: Using functional MRI for individualized target delineation in the SV may improve the treatment outcome in radiotherapy of prostate cancer without increasing the rectal toxicity.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Modelos Biológicos , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Vesículas Seminales/patología , Relación Dosis-Respuesta en la Radiación , Humanos , Masculino , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Vesículas Seminales/efectos de la radiación
5.
Acta Oncol ; 52(7): 1458-63, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23957594

RESUMEN

INTRODUCTION: Patients with left-sided breast cancer with lymph node involvement have routinely been treated with enhanced inspiration gating (EIG) for a decade at our institution. In a transition from EIG to deep inspiration breath hold (DIBH) we compared the two techniques with focus on target coverage, dose to organs at risk and reproducibility of the inspiration level (IL). MATERIAL AND METHODS: Twenty-four patients were computed tomography (CT) scanned with EIG and DIBH. For DIBH we used visual feedback and for EIG audio coaching, both during scan and treatment. Treatment plans for 50 Gy over 25 fractions were calculated. Seventeen of the patients were included in the analysis of reproducibility. They were audio coached for one minute before beam-on in DIBH at nine treatment sessions. These respiration curves were analysed with average maximum IL and standard deviation (SD) for the EIG part of the respiratory signal, and mean IL and SD for the DIBH. Comparison of dosimetric and respiration parameters were performed with the Wilcoxon signed rank-sum test. RESULTS: In DIBH, the ipsilateral lung volume increased further compared to EIG (p < 0.0004, mean increase 11%). This lead to a 9% mean reduction (p = 0.002) of the ipsilateral lung volume receiving 20 Gy (V20 Gy). We found no other significant dosimetric differences between the two methods. The reproducibility of the IL was better with the DIBH method, observed as a significantly smaller SD in most patients (p < 0.04 for 16 of 17 patients). CONCLUSION: The DIBH method resulted in a significantly larger lung volume and lower ipsilateral lung V20 Gy compared to EIG. The IL for visually guided DIBH was more reproducible than audio-coached EIG. Based on these findings, the DIBH technique is our new breathing adaptation standard for radiotherapy of patients with left-sided breast cancer with lymph node involvement.


Asunto(s)
Neoplasias de la Mama/radioterapia , Inhalación , Pulmón/efectos de la radiación , Traumatismos por Radiación/prevención & control , Planificación de la Radioterapia Asistida por Computador , Respiración/efectos de la radiación , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Órganos en Riesgo/efectos de la radiación , Pronóstico , Radiometría , Radioterapia Guiada por Imagen , Reproducibilidad de los Resultados
6.
Int J Radiat Oncol Biol Phys ; 106(5): 977-984, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32005489

RESUMEN

PURPOSE: Radiation therapy delivery during deep inspiration breath-hold (DIBH) reduces the irradiation of the heart and lungs and is therefore recommended for adults with mediastinal lymphoma. However, no studies have addressed the use of DIBH in children. This pilot study investigates the feasibility of and compliance with DIBH in children. METHODS AND MATERIALS: Children from the age of 5 years were recruited to a training session to assess their ability to perform DIBH. No children received radiation therapy. The children were placed in a potential radiation therapy position. The DIBH was voluntary and monitored using an optical surface system providing visual feedback. Children who performed 3 stable DIBHs of 20 seconds each and remained motionless were deemed DIBH compliant. Compliance, equipment suitability, and coaching were further assessed in a semistructured interview. RESULTS: We included 33 children (18 healthy and 15 hospitalized children with cancer) with a mean age of 8.5 years (range, 5-15). A total of 28 (85%) children were DIBH compliant. Twenty children were deemed immediately DIBH compliant, and 8 were deemed conditionally DIBH compliant, as DIBH compliance was presumed with custom-made immobilization and/or additional DIBH training. Mean age of the DIBH-compliant and the non-DIBH-compliant children was 8.9 years (range, 5-15) and 6 years (range, 5-9), respectively. Only 1 of 15 hospitalized children was not DIBH compliant and only 1 of all 33 children was unable to grasp the DIBH concept. The available DIBH equipment was suitable for children, and 94% reported that they were happy with training and performing DIBH. CONCLUSIONS: This pilot study demonstrated that children from the age of 5 years can potentially comply with the DIBH technique and perform stable and reproducible DIBHs suitable for radiation therapy. Custom-made immobilization and adequate training will potentially increase DIBH compliance. A prospective clinical trial (NCT03315546), investigating the dosimetric benefit of radiation therapy delivery in DIBH compared with free breathing with pediatric patients, has been initiated.


Asunto(s)
Contencion de la Respiración , Radioterapia Asistida por Computador , Adolescente , Niño , Preescolar , Estudios de Factibilidad , Femenino , Humanos , Masculino , Cooperación del Paciente , Planificación de la Radioterapia Asistida por Computador
7.
Br J Radiol ; 92(1104): 20190569, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31544478

RESUMEN

OBJECTIVES: Patients with locally advanced non-small cell lung cancer (NSCLC) were included in a prospective trial for radiotherapy in deep inspiration breath hold (DIBH). We evaluated DIBH compliance and target position reproducibility. METHODS: Voluntary, visually guided DIBHs were performed with optical tracking. Patients underwent three consecutive DIBH CT scans for radiotherapy planning. We evaluated the intrafractional uncertainties in the position of the peripheral tumour, lymph nodes and differential motion between them, enabling PTV margins calculation. Patients who underwent all DIBH imaging and had tumour position reproducibility <8 mm were up-front DIBH compliant. Patients who performed DIBHs throughout the treatment course were overall DIBH compliant. Clinical parameters and DIBH-related uncertainties were validated against our earlier pilot study. RESULTS: 69 of 88 included patients received definitive radiotherapy. 60/69 patients (87%) were up-front DIBH compliant. DIBH plan was not superior in seven patients and three lost DIBH ability during the treatment, leaving 50/69 patients (72%) overall DIBH compliant.The systematic and random errors between consecutive DIBHs were small but differed from the pilot study findings. This led to slightly different PTV margins between the two studies. CONCLUSIONS: DIBH compliance and reproducibility was high. Still, this validation study highlighted the necessity of designing PTV margins in larger, representative patient cohorts. ADVANCES IN KNOWLEDGE: We demonstrated high DIBH compliance in locally advanced NSCLC patients. DIBH does not eliminate but mitigates the target position uncertainty, which needs to be accounted for in treatment margins. Margin design should be based on data from larger representative patient groups.


Asunto(s)
Contencion de la Respiración , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Inhalación , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Humanos , Neoplasias Pulmonares/patología , Ganglios Linfáticos/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Movimientos de los Órganos , Proyectos Piloto , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Incertidumbre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA