Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Neuroradiology ; 55(4): 423-30, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23223824

RESUMEN

INTRODUCTION: High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. METHODS: CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. RESULTS: Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35% (218.2 ± 30 versus 141.8 ± 20 mGy × cm). CONCLUSIONS: Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.


Asunto(s)
Angiografía/métodos , Aorta Torácica/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Carga Corporal (Radioterapia) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Clin Neuropathol ; 25(3): 123-7, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16719408

RESUMEN

Bronchogenic cysts are rare findings within the central nervous system and even extremely seldom if they are located supratentorially. We report on a 25-year-old man who presented with a single generalized seizure without any accompanying neurological deficit 6 weeks prior to admission. MRI showed a smoothly limited, non-calcified cyst of a maximum of 55 mm in diameter. Large parts of the membrane were removed through a right anterior craniotomy, and a fenestration into the subarachnoidal space was performed. Histopathological examinations revealed a bronchogenic cyst. Previous reports of neurenteric cysts are reviewed. Therapeutic options, pathogenesis and categorization of this uncommon congenital entity are discussed.


Asunto(s)
Quiste Broncogénico/patología , Lóbulo Frontal , Neoplasias Supratentoriales/patología , Adulto , Quiste Broncogénico/cirugía , Humanos , Masculino , Neoplasias Supratentoriales/cirugía
3.
Clin Neuroradiol ; 25(1): 33-40, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24343701

RESUMEN

PURPOSE: We investigated the agreement of dual-energy computed tomography angiography (DE-CTA) and contrast-enhanced magnetic resonance angiography (CE-MRA)in the quantitative measurement of stenoses of the internal carotid artery in comparison with digital subtraction angiography (DSA). METHODS: A total of 21 patients with stenoses of the external carotid artery were investigated with a DE-CTA and CE-MRA before undergoing carotid angioplasty. The grade of the stenoses was assessed in axial multiplanar reformations (MPR) before and multi-intensity projections (MIP) after plaque subtraction (PS) and compared with results from CE-MRA and DSA according to the North American Symptomatic Carotid Endarterectomy Trial. RESULTS: Average grades of stenoses were 80.7 ± 16.1 % (DSA), 81.4 ± 15.3 % (MRA), 80.0 ± 16.7 % (DE-CTA-MPR), and 85.2 ± 14.7 % (DE-CTA-PS-MIP). Of 21 stenoses, 6 were filiform (stenosis grade, 99 %) in the DSA examination. Five of these cases were identified as pseudo-occlusions in MRA, while four were considered as occlusions in DE-CTA-PS-MIP. Another four cases were identified as pseudo-occlusion in DE-CTA-PS-MIP, which were identified as 90 % stenosis in the DSA examination. CONCLUSIONS: In comparison with the gold standard DSA, DE-CTA-MPR had a slightly better agreement in measuring the degree of stenosis of the internal carotid arteries than CE-MRA. In DE-CTA-PS-MIP images, a systematic overestimation has to be taken into account due to partial extinction of the lumen by the PS algorithm. Nevertheless, DE-CTA should be preferred in imaging patients with carotid artery stenosis in the presence of extensive calcifications.


Asunto(s)
Calcinosis/diagnóstico , Estenosis Carotídea/diagnóstico , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Calcinosis/complicaciones , Estenosis Carotídea/complicaciones , Medios de Contraste , Femenino , Humanos , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
4.
Clin Neuroradiol ; 25(3): 241-7, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24599323

RESUMEN

PURPOSE: The evaluation of carotid-cavernous fistulas (CCFs) and the intracranial vasculature has been predominantly carried out using conventional digital subtraction angiography (DSA). Recent developments in time-resolved magnetic resonance angiography (MRA) provide the opportunity to assess both multiple arterial and venous phases with high temporal and spatial resolution. Here, we investigated the feasibility of this technique to functionally assess CCF prior to intervention. METHODS: Six consecutive patients with clinical symptoms of a CCF were scheduled for clinically indicated MRA and underwent a protocol that comprised conventional imaging sequences and high resolution time-resolved MRA with interleaved stochastic trajectories (TWIST). The location of the fistulous communication, the flow pattern, and venous drainage were determined by time-resolved MRA and compared with DSA which was available in five out of six patients. RESULTS: Typical morphological findings (including enlargement of the superior ophthalmic vein, exophthalmos) were found in all cases in both conventional MRI and time-resolved MRA source data. The temporal resolution of time-resolved MRA enabled a good separation of the early filling of the cavernous sinus during the arterial phase. Direct fistulous communication was assessed in three patients with good correlation to DSA, whereas indirect CCF could not definitely be visualized. The time-resolved MRA provided information about the flow pattern and the venous drainage of the fistula in all patients, which is essential for therapy planning. CONCLUSION: Time-resolved MRA provides important morphological and functional information in patients with CCF. Although DSA remains the gold standard for diagnosis and exact classification of fistulas, time-resolved MRA can provide the relevant hemodynamic information to plan interventional treatment as a one-step procedure with a focused diagnostic workup.


Asunto(s)
Fístula del Seno Cavernoso de la Carótida/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Cuidados Preoperatorios/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Fístula del Seno Cavernoso de la Carótida/cirugía , Toma de Decisiones Clínicas/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Planificación de Atención al Paciente , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesos Estocásticos
5.
Schweiz Rundsch Med Prax ; 83(18): 548-9, 1994 May 03.
Artículo en Alemán | MEDLINE | ID: mdl-8197343

RESUMEN

Working as a neonatology nurse means not only taking care of the very little and sometimes critically ill patients, but also means being confronted with ethical problems. High-tech medicine, we hope, to help our little patients, but can also irritate and endanger their sensible system. That puts us before the question: If it makes sense to use every medical possibility? These conflicts can bring problems into the team of nurses, doctors and parents. It is our aim that we have the time and space to confront such problems and to find solutions.


Asunto(s)
Enfermedades del Recién Nacido/enfermería , Enfermedades del Prematuro/enfermería , Cuidado Intensivo Neonatal , Humanos , Recién Nacido , Recien Nacido Prematuro , Padres/psicología , Apoyo Social
6.
AJNR Am J Neuroradiol ; 33(2): 218-24, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22033719

RESUMEN

BACKGROUND AND PURPOSE: IR has recently demonstrated its capacity to reduce noise and permit dose reduction in abdominal and thoracic CT applications. The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels. MATERIALS AND METHODS: Ninety consecutive patients were randomly assigned to undergo nonenhanced and contrast-enhanced head CT at a standard dose (320 mAs; CTDI, 60.1) or 15% (275 mAs; CTDI, 51.8) and 30% (225 mAs; CTDI, 42.3) dose reduction. All acquisitions were reconstructed with IR in image space, and FBP and images were assessed in terms of quantitative and qualitative IQ. RESULTS: Compared with FBP, IR resulted in lower image noise (P ≤ .02), higher CNR (P ≤ .03), and improved subjective image quality (P ≤ .002) at all dose levels. While degradation of objective and subjective IQ at 15% dose reduction was fully compensated by IR (CNR, 1.98 ± 0.4 at 320 mAs with FBP versus 2.05 ± 0.4 at 275 mAs with IR; IQ, 1.8 versus 1.7), IQ was considerably poorer at 70% standard dose despite using the iterative approach (CNR, 1.98 ± 0.3 at 320 mAs with FBP versus 1.85 ± 0.4 at 225 mAs with IR, P = .18; IQ, 1.8 versus 2.2, P = .03). Linear regression analysis of CNR against tube current suggests that standard CNR may be obtained until approximately 20.4% dose reduction when IR is used. CONCLUSIONS: Compared with conventional FBP, IR of head CT is associated with significant improvement of objective and subjective IQ and may allow dose reductions in the range of 20% without compromising standard image quality.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Masculino , Persona de Mediana Edad
7.
Eur J Radiol ; 80(2): e120-5, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20833492

RESUMEN

OBJECTIVES: Calcifications adjacent to the vessel lumen often limit the assessment of stenoses at the carotid bifurcation in 3D multi intensity projection images (3D-MIP) using conventional single energy CT. Aim of the study was to evaluate the diagnostic value of 3D-MIP images after subtraction of bone and calcified plaques (PBS) using dual energy CT for the assessment of carotid bifurcation stenoses. MATERIALS AND METHODS: 36 patients with a total of 46 stenoses at the carotid bifurcation were examined with a dual energy CT system. Grade of the stenoses and plaque morphology were assessed in axial multi planar projections (axMPR) and freely rotatable 3D-MIP images before and after PBS and compared with results from DSA. RESULTS: Grade of the stenosis could be evaluated in all 46 cases in DSA, axMPR and 3D-MIP after PBS. However, in 25 cases grade of the stenosis was not assessable prior to PBS. The average grade of the stenosis increased from DSA (81.4%) to axMPR (83.5%) to 3D-MIP before and after PBS (86.5% and 85.6%). The amount of pseudo-occlusions increased in concordance with the grade of the stenosis (0<9<16). Using 3D-MIP reconstructions, plaque morphology could be evaluated in 32/46 stenoses before PBS and in 44/46 cases after PBS. CONCLUSIONS: PBS facilitated the evaluation of grade of the stenosis in all cases. Nevertheless, after PBS stenoses were overrated in 3D-MIP in comparison to DSA and axMPR. Moreover, plaque morphology, as an independent risk factor for stroke, can be evaluated even in calcified plaques after PBS. Therefore dual energy CTA with plaque subtraction has the potential to identify patients with vulnerable plaques better than conventional CTA.


Asunto(s)
Angiografía de Substracción Digital/métodos , Calcinosis/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Angiografía Cerebral/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados
8.
Eur J Radiol ; 79(3): 389-99, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20478675

RESUMEN

OBJECTIVE: The objective of this article is to describe MR imaging findings of spinal cord pilocytic astrocytomas at first presentation and following neurosurgery and to discuss briefly some of the most common differential diagnoses. CONCLUSION: MR imaging findings in medullary pilocytic astrocytomas consist generally of focal or diffuse cord-enlarging masses that are irregularly shaped, accompanied by cystic elements and hydromyelia, present different degrees of contrast enhancement, high water diffusivity and a propensity for the thoracic and cervical cord.


Asunto(s)
Astrocitoma/diagnóstico , Imagen por Resonancia Magnética/métodos , Neoplasias de la Médula Espinal/diagnóstico , Astrocitoma/cirugía , Medios de Contraste , Diagnóstico Diferencial , Humanos , Neoplasias de la Médula Espinal/cirugía
9.
J Nurs Adm ; 17(10): 11-5, 1987 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-3655917

RESUMEN

If computerization of patient care information is to be successful, nurses must be involved in the process from the beginning. This article describes the process used by a committee in choosing a hospital information system and the roles of the nurses who served on the committee.


Asunto(s)
Sistemas de Información en Hospital , Servicio de Enfermería en Hospital , Propuestas de Licitación , Humanos , Michigan , Comité de Profesionales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA