Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Neuropharmacology ; 49(6): 850-61, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16183084

RESUMEN

The excitatory amino acid transporters (EAATs) play key roles in the regulation of CNS L-glutamate, especially related to synthesis, signal termination, synaptic spillover, and excitotoxic protection. Inhibitors available to delineate EAAT pharmacology and function are essentially limited to those that non-selectively block all EAATs or those that exhibit a substantial preference for EAAT2. Thus, it is difficult to selectively study the other subtypes, particularly EAAT1 and EAAT3. Structure activity studies on a series of beta-substituted aspartate analogues identify L-beta-benzyl-aspartate (L-beta-BA) as among the first blockers that potently and preferentially inhibits the neuronal EAAT3 subtype. Kinetic analysis of D-[(3)H]aspartate uptake into C17.2 cells expressing the hEAATs demonstrate that L-beta-threo-BA is the more potent diastereomer, acts competitively, and exhibits a 10-fold preference for EAAT3 compared to EAAT1 and EAAT2. Electrophysiological recordings of EAAT-mediated currents in Xenopus oocytes identify L-beta-BA as a non-substrate inhibitor. Analyzing L-beta-threo-BA within the context of a novel EAAT2 pharmacophore model suggests: (1) a highly conserved positioning of the electrostatic carboxyl and amino groups; (2) nearby regions that accommodate select structural modifications (cyclopropyl rings, methyl groups, oxygen atoms); and (3) a unique region L-beta-threo-BA occupied by the benzyl moieties of L-TBOA, L-beta-threo-BA and related analogues. It is plausible that the preference of L-beta-threo-BA and L-TBOA for EAAT3 and EAAT2, respectively, could reside in the latter two pharmacophore regions.


Asunto(s)
Sistema de Transporte de Aminoácidos X-AG/antagonistas & inhibidores , Ácido Aspártico/análogos & derivados , Ácido Aspártico/farmacología , Transportador 3 de Aminoácidos Excitadores/antagonistas & inhibidores , Neuronas/efectos de los fármacos , Animales , Ácido Aspártico/química , Línea Celular Transformada , Relación Dosis-Respuesta a Droga , Estimulación Eléctrica/métodos , Transportador 1 de Aminoácidos Excitadores/fisiología , Transportador 2 de Aminoácidos Excitadores/fisiología , Transportador 3 de Aminoácidos Excitadores/fisiología , Expresión Génica/efectos de los fármacos , Expresión Génica/fisiología , Potenciales de la Membrana/efectos de los fármacos , Potenciales de la Membrana/fisiología , Potenciales de la Membrana/efectos de la radiación , Ratones , Modelos Moleculares , Neuronas/metabolismo , Oocitos , Técnicas de Placa-Clamp/métodos , Transfección/métodos , Tritio/farmacocinética , Xenopus
2.
Circ Heart Fail ; 6(3): 517-26, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23479562

RESUMEN

BACKGROUND: Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding. METHODS AND RESULTS: The Utah Transplantation Affiliated Hospitals (U.T.A.H.) heart failure and transplant program databases were queried for patients with end-stage heart failure who required support with the continuous-flow LVAD HeartMate II (Thoratec Corp, Pleasanton, CA) between 2004 and 2012. Pulsatility was evaluated by means of the LVAD parameter pulsatility index (PI) and by the echocardiographic assessment of aortic valve opening during the first 3 months of LVAD support. PI was analyzed as a continuous variable and also stratified according to tertiles of all the PI measurements during the study period (low PI: <4.6, intermediate PI: 4.6-5.2, and high PI: >5.2). Major nonsurgical bleeding associated with a decrease in hemoglobin ≥2 g/dL (in the absence of hemolysis) was the primary end point. A total of 134 patients (median age of 60 [interquartile range: 49-68] years, 78% men) were included. Major bleeding occurred in 33 (25%) patients (70% gastrointestinal, 21% epistaxis, 3% genitourinary, and 6% intracranial). In multivariable analysis, PI examined either as a categorical variable, low versus high PI (hazard ratio, 4.06; 95% confidence interval, 1.35-12.21; P=0.04), or as a continuous variable (hazard ratio, 0.60; 95% confidence interval, 0.40-0.92; P=0.02) was associated with an increased risk of bleeding. CONCLUSIONS: Reduced pulsatility in patients supported with the continuous-flow LVAD HeartMate II is associated with an increased risk of nonsurgical bleeding, as evaluated by PI.


Asunto(s)
Hemorragia Gastrointestinal/epidemiología , Hemorragia Gastrointestinal/fisiopatología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Flujo Pulsátil , Anciano , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos , Medición de Riesgo
3.
J Am Coll Cardiol ; 61(19): 1985-94, 2013 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-23500219

RESUMEN

OBJECTIVES: This study sought to prospectively investigate the longitudinal effects of continuous-flow left ventricular assist device (LVAD) unloading on myocardial structure and systolic and diastolic function. BACKGROUND: The magnitude, timeline, and sustainability of changes induced by continuous-flow LVAD on the structure and function of the failing human heart are unknown. METHODS: Eighty consecutive patients with clinical characteristics consistent with chronic heart failure requiring implantation of a continuous-flow LVAD were prospectively enrolled. Serial echocardiograms (at 1, 2, 3, 4, 6, 9, and 12 months) and right heart catheterizations were performed after LVAD implant. Cardiac recovery was assessed on the basis of improvement in systolic and diastolic function indices on echocardiography that were sustained during LVAD turn-down studies. RESULTS: After 6 months of LVAD unloading, 34% of patients had a relative LV ejection fraction increase above 50% and 19% of patients, both ischemic and nonischemic, achieved an LV ejection fraction ≥ 40%. LV systolic function improved as early as 30 days, the greatest degree of improvement was achieved by 6 months of mechanical unloading and persisted over the 1-year follow up. LV diastolic function parameters also improved as early as 30 days after LVAD unloading, and this improvement persisted over time. LV end-diastolic and end-systolic volumes decreased as early as 30 days after LVAD unloading (113 vs. 77 ml/m(2), p < 0.01, and 92 vs. 60 ml/m(2), p < 0.01, respectively). LV mass decreased as early as 30 days after LVAD unloading (114 vs. 95 g/m(2), p < 0.05) and continued to do so over the 1-year follow-up but did not reach values below the normal reference range, suggesting no atrophic remodeling after prolonged LVAD unloading. CONCLUSIONS: Continuous-flow LVAD unloading induced in a subset of patients, both ischemic and nonischemic, early improvement in myocardial structure and systolic and diastolic function that was largely completed within 6 months, with no evidence of subsequent regression.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Anciano , Diástole , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Volumen Sistólico , Sístole , Ultrasonografía , Función Ventricular Izquierda
4.
ASAIO J ; 56(1): 57-60, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20051832

RESUMEN

Driveline exit site (DLES) infection is a persistent problem among the left ventricular assist device (LVAD) patients. This study investigated the relationship between obesity and DLES infection. Records of LVAD patients at two institutions from January 1999 to January 2009 were queried. Results were analyzed using t tests. Those with LVAD support > or =90 days were included. The body mass index (BMI) of each patient was measured at the time of implant and at the conclusion of LVAD support or currently, if the patient was ongoing. Other data included preimplant age, ejection fraction, blood urea nitrogen, creatinine, diabetes, New York Heart Association class, pulmonary capillary wedge pressure, VO2 max, and inotrope therapy. The 118 patients who qualified for the study were placed in an infection group (n = 36) or in the control group (n = 82). Both groups had similar preimplant characteristics. Variables with differences statistically significant between the groups included duration of LVAD support, indication for support, device type, and BMI. Patients who developed DLES infections had a significantly higher BMI and continued weight gain over the course of LVAD therapy compared with the control group. Although this association requires further study, implications for clinical practice may include the provision of nutrition and exercise counseling for patients undergoing LVAD therapy, especially if overweight. These results may warrant increased measures to prevent and treat infection in the preimplant and postimplant periods.


Asunto(s)
Corazón Auxiliar/efectos adversos , Obesidad/complicaciones , Infecciones Relacionadas con Prótesis/complicaciones , Índice de Masa Corporal , Humanos , Persona de Mediana Edad , Prevalencia , Infecciones Relacionadas con Prótesis/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA