Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Acta Orthop ; 86(1): 78-85, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25175663

RESUMEN

BACKGROUND: Fast-track has become a well-known concept resulting in improved patient satisfaction and postoperative results. Concerns have been raised about whether increased efficiency could compromise safety, and whether early hospital discharge might result in an increased number of complications. We present 1-year follow-up results after implementing fast-track in a Norwegian university hospital. METHODS: This was a register-based study of 1,069 consecutive fast-track hip and knee arthroplasty patients who were operated on between September 2010 and December 2012. Patients were followed up until 1 year after surgery. RESULTS: 987 primary and 82 revision hip or knee arthroplasty patients were included. 869 primary and 51 revision hip or knee patients attended 1-year follow-up. Mean patient satisfaction was 9.3 out of a maximum of 10. Mean length of stay was 3.1 days for primary patients. It was 4.2 days in the revision hip patients and 3.9 in the revision knee patients. Revision rates until 1-year follow-up were 2.9% and 3.3% for primary hip and knee patients, and 3.7% and 7.1% for revision hip and knee patients. Function scores and patient-reported outcome scores were improved in all groups. INTERPRETATION: We found reduced length of stay, a high level of patient satisfaction, and low revision rates, together with improved health-related quality of life and functionality, when we introduced fast-track into an orthopedic department in a Norwegian university hospital.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Tiempo de Internación/estadística & datos numéricos , Satisfacción del Paciente/estadística & datos numéricos , Atención Perioperativa/métodos , Sistema de Registros , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Protocolos Clínicos , Estudios de Cohortes , Ambulación Precoz/métodos , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Noruega , Evaluación de Resultado en la Atención de Salud , Manejo del Dolor/métodos , Reoperación , Adulto Joven
2.
Expert Opin Drug Deliv ; 20(7): 895-903, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37249542

RESUMEN

INTRODUCTION: Biologics, especially monoclonal antibodies (mAbs), have become a major class of therapeutics in recent years addressing the needs of millions of patients and becoming one of the best-selling treatments in the pharmaceutical market. A wide range of multifaceted chronic diseases have benefitted from antibody therapeutics. Long-term treatment for chronic diseases with mAb therapies can mean a lifetime of frequent injections. Technologies that can minimize the total number of injections present meaningful value to patients and the companies that develop them. AREAS COVERED: This review summarizes the challenges encountered during the development of long-acting versions of mAbs. The focus will be on questions addressed during drug product development, delivery device selection, business implications, and understanding the market potential of long-acting presentations. EXPERT OPINION: Long-acting drug delivery systems have reached the market for small molecules and peptides. However, these drug delivery systems, and their development lessons, cannot be extrapolated directly to antibodies. We must develop new delivery technologies suitable for biologics, identify critical attributes to capture dynamic changes in proteins during the encapsulation process, and develop analytical processes to evaluate long-term stability.


Asunto(s)
Productos Biológicos , Sistemas de Liberación de Medicamentos , Humanos , Sistemas de Liberación de Medicamentos/métodos , Péptidos , Anticuerpos Monoclonales/uso terapéutico , Enfermedad Crónica
3.
Drug Des Devel Ther ; 15: 159-170, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33469268

RESUMEN

Subcutaneous (SC) delivery of biologics has traditionally been limited to fluid volumes of 1-2 mL, with recent increases to volumes of about 3 mL. This injection volume limitation poses challenges for high-dose biologics, as these formulations may also require increased solution concentration in many cases, resulting in high viscosities which can affect the stability, manufacturability, and delivery/administration of therapeutic drugs. Currently, there are technologies that can help to overcome these challenges and facilitate the delivery of larger amounts of drug through the SC route. This can be achieved either by enabling biologic molecules to be formulated or delivered as high-concentration injectables (>100 mg/mL for antibodies) or through facilitating the delivery of larger volumes of fluid (>3 mL). The SC Drug Delivery and Development Consortium, which was established in 2018, aims to identify and address critical gaps and issues in the SC delivery of high-dose/volume products to help expand this delivery landscape. Identified as a high priority out of the Consortium's eight problem statements, it highlights the need to shift perceptions of the capabilities of technologies that enable the SC delivery of large-volume (>3 mL) and/or high-dose biologics. The Consortium emphasizes a patient-focused approach towards the adoption of SC delivery of large-volume/high-concentration dosing products to facilitate the continued expansion of the capabilities of novel SC technologies. To raise awareness of the critical issues and gaps in high-dose/volume SC drug development, this review article provides a generalized overview of currently available and emerging technologies and devices that could facilitate SC delivery of high-dose/volume drug formulations. In addition, it discusses the challenges, gaps, and future outlook in high-dose/volume SC delivery as well as potential solutions to exploit the full value of the SC route of administration.


Asunto(s)
Productos Biológicos/administración & dosificación , Sistemas de Liberación de Medicamentos , Relación Dosis-Respuesta a Droga , Humanos , Inyecciones Subcutáneas
4.
Pharm Res ; 26(9): 2194-201, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19582550

RESUMEN

PURPOSE: An ex vivo intact toe model was developed to assess two different applicator designs for iontophoretic delivery of terbinafine into the nail only or the nail and surrounding skin. METHODS: Iontophoretic permeation studies were carried out on intact cadaver toes using nail-only and nail/skin applicators with a current dose of 10 mA*min (0.5 mA for 20 min). RESULTS: Iontophoresis enhanced drug permeation and tissue loading with both applicators tested. Greater drug delivery was observed with the nail/skin applicator due to the additional terbinafine being delivered directly through the lower impedance skin area surrounding the nail. The concentration of drug loaded into the contact area of the nail with the nail-only and nail/skin applicator was ~13 and ~7 fold higher than their respective passive delivery levels but equivalent from each other in total drug mass delivered over the whole nail plate. In vitro release of drug from the iontophoretically loaded nails into agar suggests that a single treatment could have a prolonged effect (>50 days). CONCLUSIONS: This study demonstrates that the ex vivo toe model was useful in assessing the functionality of the different applicator designs. These results suggest that iontophoresis can significantly enhance the delivery of drugs to both the hard and soft tissues of the toe for the treatment of onychomycosis and other nail disorders.


Asunto(s)
Iontoforesis , Modelos Teóricos , Naftalenos/administración & dosificación , Cromatografía Líquida de Alta Presión , Humanos , Concentración de Iones de Hidrógeno , Uñas/metabolismo , Naftalenos/farmacocinética , Piel/metabolismo , Terbinafina
5.
Nat Biomed Eng ; 2(3): 151-157, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-31015714

RESUMEN

The advancement of point-of-care diagnostics and the decentralization of healthcare have created a need for the simple, safe, standardized and painless collection of blood specimens. Here, we describe the design and implementation of a capillary blood-collection device that is more convenient and less painful than a fingerstick and venepuncture, and collects 100 µl of blood. The technology integrates into a compact, self-contained device an array of solid microneedles, a high-velocity insertion mechanism, stored vacuum, and a microfluidic system containing lithium heparin anticoagulant. The use of the device requires minimal training, as blood collection is initiated by the single push of a button. In a clinical study involving 144 participants, haemoglobin A1c measurements from device-collected samples and from venous blood samples were equivalent, and the pain associated with the device was significantly less than that associated with venepuncture. The device, which has received premarket clearance by the US Food and Drug Administration, should help improve access to healthcare, and support healthcare decentralization.


Asunto(s)
Recolección de Muestras de Sangre , Agujas , Recolección de Muestras de Sangre/instrumentación , Recolección de Muestras de Sangre/métodos , Diseño de Equipo , Humanos , Sistemas de Atención de Punto
6.
IEEE Trans Biomed Eng ; 52(5): 909-15, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15887540

RESUMEN

The goal of this study was to design, fabricate, and test arrays of hollow microneedles for minimally invasive and continuous delivery of insulin in vivo. As a simple, robust fabrication method suitable for inexpensive mass production, we developed a modified-LIGA process to micromachine molds out of polyethylene terephthalate using an ultraviolet laser, coated those molds with nickel by electrodepostion onto a sputter-deposited seed layer, and released the resulting metal microneedle arrays by selectively etching the polymer mold. Mechanical testing showed that these microneedles were sufficiently strong to pierce living skin without breaking. Arrays containing 16 microneedles measuring 500 microm in length with a 75 microm tip diameter were then inserted into the skin of anesthetized, diabetic, hairless rats. Insulin delivery through microneedles caused blood glucose levels to drop steadily to 47% of pretreatment values over a 4-h insulin delivery period and were then approximately constant over a 4-h postdelivery monitoring period. Direct measurement of plasma insulin levels showed a peak value of 0.43 ng/ml. Together, these data suggest that microneedles can be fabricated and used for in vivo insulin delivery.


Asunto(s)
Diabetes Mellitus/tratamiento farmacológico , Infusiones Parenterales/instrumentación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Agujas , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Infusiones Parenterales/métodos , Masculino , Metales , Miniaturización/métodos , Ratas , Ratas Sprague-Dawley , Resultado del Tratamiento
7.
J Biomech ; 37(8): 1155-63, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15212920

RESUMEN

As a hybrid between a hypodermic needle and transdermal patch, we have used microfabrication technology to make arrays of micron-scale needles that transport drugs and other compounds across the skin without causing pain. However, not all microneedle geometries are able to insert into skin at reasonable forces and without breaking. In this study, we experimentally measured and theoretically modeled two critical mechanical events associated with microneedles: the force required to insert microneedles into living skin and the force needles can withstand before fracturing. Over the range of microneedle geometries investigated, insertion force was found to vary linearly with the interfacial area of the needle tip. Measured insertion forces ranged from approximately 0.1-3N, which is sufficiently low to permit insertion by hand. The force required to fracture microneedles was found to increase with increasing wall thickness, wall angle, and possibly tip radius, in agreement with finite element simulations and a thin shell analytical model. For almost all geometries considered, the margin of safety, or the ratio of fracture force to insertion force, was much greater than one and was found to increase with increasing wall thickness and decreasing tip radius. Together, these results provide the ability to predict insertion and fracture forces, which facilitates rational design of microneedles with robust mechanical properties.


Asunto(s)
Sistemas de Liberación de Medicamentos/instrumentación , Microinyecciones/instrumentación , Agujas , Piel , Diseño de Equipo , Humanos , Inyecciones Intradérmicas , Microinyecciones/métodos , Estrés Mecánico , Tecnología Farmacéutica/instrumentación
8.
J Pharm Sci ; 101(8): 2861-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22644951

RESUMEN

The purpose of this study was to determine the effect of microneedle (MN) technology and its combination with iontophoresis (ITP) on the in vivo transdermal delivery of salmon calcitonin (sCT). Maltose MNs (500 µm) were used to porate skin prior to application of the drug, with or without ITP. Micropores created by maltose MNs were characterized by histological sectioning and calcein imaging studies, which indicated uniformity of the created micropores. In vivo studies were performed in hairless rats to assess the degree of enhancement achieved by ITP (0.2 mA/cm² for 1 h), MNs (81 MNs), and their combination. In vivo studies indicate a serum maximal concentration of 0.61 ± 0.42 ng/mL, 1.79 ± 0.72 ng/mL, and 5.51 ± 0.32 ng/mL for ITP, MNs, and combination treatment, respectively. MN treatment alone increased serum concentration 2.5-fold and the combination treatment increased the concentration ninefold as compared with iontophoretic treatment alone. Combination treatment of ITP and MNs resulted in the highest delivery of sCT and therapeutic levels were achieved within 5 min of administration.


Asunto(s)
Conservadores de la Densidad Ósea/administración & dosificación , Conservadores de la Densidad Ósea/farmacocinética , Calcitonina/administración & dosificación , Calcitonina/farmacocinética , Sistemas de Liberación de Medicamentos/instrumentación , Iontoforesis/instrumentación , Piel/metabolismo , Administración Cutánea , Animales , Conservadores de la Densidad Ósea/sangre , Calcitonina/sangre , Diseño de Equipo , Maltosa/química , Ratas , Ratas sin Pelo
9.
Artículo en Inglés | MEDLINE | ID: mdl-19964736

RESUMEN

An iontophoretic treatment system for onychomycosis, using drug applicators targeting either toe nail only or nail and surrounding tissue, is analyzed. Phase 1 clinical data shows levels of drug delivery that differ unexpectedly from relative dosing level to multiple tissue types. Current monitoring and analysis techniques, coupled with assays of drug delivery into excised nail and cadaver toe, were used to evaluate drug delivery vs. current flow. The results indicate good correlation with piecewise linear models of current flow and extracted drug in the nail-only application. For the nail and surrounding tissue application, assayed drug levels indicate that on average, drug load per unit dose (mA-min) is more efficient into nail than into surrounding tissue (2.38:1 ug/mA-min nail vs. surrounding tissue, n=6, p=0.009).


Asunto(s)
Dermatosis del Pie/tratamiento farmacológico , Dermatosis del Pie/metabolismo , Iontoforesis/métodos , Naftalenos/administración & dosificación , Naftalenos/farmacocinética , Onicomicosis/tratamiento farmacológico , Onicomicosis/metabolismo , Relación Dosis-Respuesta en la Radiación , Campos Electromagnéticos , Humanos , Tasa de Depuración Metabólica/efectos de la radiación , Terbinafina
10.
Pharm Res ; 21(6): 947-52, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15212158

RESUMEN

PURPOSE: The purpose of this study was to design and fabricate arrays of solid microneedles and insert them into the skin of diabetic hairless rats for transdermal delivery of insulin to lower blood glucose level. METHODS: Arrays containing 105 microneedles were laser-cut from stainless steel metal sheets and inserted into the skin of anesthetized hairless rats with streptozotocin-induced diabetes. During and after microneedle treatment, an insulin solution (100 or 500 U/ml) was placed in contact with the skin for 4 h. Microneedles were removed 10 s, 10 min, or 4 h after initiating transdermal insulin delivery. Blood glucose levels were measured electrochemically every 30 min. Plasma insulin concentration was determined by radioimmunoassay at the end of most experiments. RESULTS: Arrays of microneedles were fabricated and demonstrated to insert fully into hairless rat skin in vivo. Microneedles increased skin permeability to insulin, which rapidly and steadily reduced blood glucose levels to an extent similar to 0.05-0.5 U insulin injected subcutaneously. Plasma insulin concentrations were directly measured to be 0.5-7.4 ng/ml. Higher donor solution insulin concentration, shorter insertion time, and fewer repeated insertions resulted in larger drops in blood glucose level and larger plasma insulin concentrations. CONCLUSIONS: Solid metal microneedles are capable of increasing transdermal insulin delivery and lowering blood glucose levels by as much as 80% in diabetic hairless rats in vivo.


Asunto(s)
Administración Cutánea , Insulina/administración & dosificación , Microinyecciones/métodos , Agujas , Animales , Glucemia/efectos de los fármacos , Modelos Animales de Enfermedad , Sistemas de Liberación de Medicamentos/instrumentación , Evaluación Preclínica de Medicamentos/métodos , Predicción , Insulina/sangre , Insulina/farmacocinética , Masculino , Ratones , Ratones Pelados , Ratas , Ratas Sprague-Dawley , Absorción Cutánea/efectos de los fármacos , Absorción Cutánea/fisiología , Acero Inoxidable , Tecnología Farmacéutica
11.
Proc Natl Acad Sci U S A ; 100(24): 13755-60, 2003 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-14623977

RESUMEN

Arrays of micrometer-scale needles could be used to deliver drugs, proteins, and particles across skin in a minimally invasive manner. We therefore developed microfabrication techniques for silicon, metal, and biodegradable polymer microneedle arrays having solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 microm. When solid microneedles were used, skin permeability was increased in vitro by orders of magnitude for macromolecules and particles up to 50 nm in radius. Intracellular delivery of molecules into viable cells was also achieved with high efficiency. Hollow microneedles permitted flow of microliter quantities into skin in vivo, including microinjection of insulin to reduce blood glucose levels in diabetic rats.


Asunto(s)
Microinyecciones/instrumentación , Jeringas , Administración Cutánea , Animales , Ingeniería Biomédica , Glucemia/metabolismo , Línea Celular , Diabetes Mellitus Experimental/sangre , Diabetes Mellitus Experimental/tratamiento farmacológico , Diseño de Equipo , Vidrio , Humanos , Técnicas In Vitro , Insulina/administración & dosificación , Sustancias Macromoleculares , Masculino , Metales , Modelos Biológicos , Nanotecnología , Polímeros , Ratas , Silicio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA