Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 98(4): E617-E625, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33856097

RESUMEN

BACKGROUND: Very few data exist on percutaneous mitral valve repair (PMVr) in unstable patients with concomitant moderate-severe mitral regurgitation (MR). The purpose of this systematic review was to evaluate baseline characteristics, management and clinical outcomes of critically ill patients undergoing PMVr with MitraClip. METHODS: We conducted a systematic review of the published data on MitraClip from its first use in 2003 to December 2020. Studies referring to critically ill patients in cardiogenic shock or acute refractory pulmonary edema were included. A total of 40 publications including 254 patients with significant MR (Grade 4 in 91%) were included. RESULTS: Mean age was 70 ± 12 years with mean Euroscore II and STS of 21 ± 13 and 20.5 ± 16, respectively. Clinical presentation was with cardiogenic shock and acute myocardial infarction in 72.8 and 60.0% of patients, respectively. Device success was achieved in 238 (93.7%) patients with a significant reduction in MR (Grade ≤ 2 in 91.8%, p < .001). The median weaning time from the procedure, to discontinuation of mechanical circulatory or respiratory support, was 2 days (IQR 1-4), with an in-hospital mortality and non-fatal complication rate of 12.6 and 9.1%, respectively. Kaplan-Meier curves estimated an overall mortality rate of 39.1% at 12-month follow-up, with persistent reduction in MR severity for survivors (Grade ≤ 2 in 81.3%) and one case of mitral valve reintervention. CONCLUSIONS: Percutaneous mitral valve repair with MitraClip device is a technically feasible and potentially viable management option in high-risk patients with cardiogenic shock or refractory pulmonary edema and concomitant moderate-severe MR. Prospective trials are required to confirm these findings, and definitively determine the value of MitraClip in hemodynamically unstable patients.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
2.
J Card Surg ; 36(1): 31-39, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33085128

RESUMEN

OBJECTIVE: The heart team (HT) approach plays a key role in selecting the optimal treatment strategy for patients with aortic stenosis (AS). However, little is known about the HT decision process and its impact on outcomes. The aim of this study was to identify the factors associated with the HT decision and evaluate clinical outcomes according to the treatment choice. METHODS: The study included a total of 286 consecutive patients with AS referred for discussion in the weekly HT meeting in a cardiovascular institute over 2 years. Patients were stratified according to the selected therapeutic approach: medical treatment (MT), surgical (SAVR), or transcatheter (TAVR) aortic valve replacement. Baseline characteristics involved in making a therapeutic choice were identified and a decision-making tree was built using classification and regression tree methodology. RESULTS: Based on HT discussion, 53 patients were assigned to SAVR, 210 to TAVR, and 23 to MT. Older patients (≥88 years old) were mainly assigned to TAVR or MT according to the logistic EuroSCORE (

Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
3.
Circ J ; 82(11): 2880-2886, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30135324

RESUMEN

BACKGROUND: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) remains an important issue. The aim of this study was to assess the value of a new discongruence index, to predict PPM after TAVR.Methods and Results: A total of 185 patients with severe aortic stenosis who underwent TAVR with the Edwards Sapien prosthesis or CoreValve Revalving system were included (Edwards valve, n=119; Core Valve Revalving system, n=66). Discongruence index was calculated pre-procedurally as the ratio of selected transcatheter valve size (mm) to body surface area (cm2). PPM was defined as effective orifice area (EOA) ≤0.85 cm2/m2 on transthoracic echocardiography before hospital discharge. Mean age was 82±5 years and 72 patients (38.9%) were men. The overall incidence of post-TAVR PPM was 35.1% (n=65). Discongruence index correlated with post-TAVR indexed EOA (y=0.18+0.057x; P<0.001). On multivariate logistic regression analysis, discongruence index was the only independent predictor of post-TAVR PPM (OR, 0.15; 95% CI: 0.03-0.66; P=0.012), and the area under the receiver operating characteristic curve was 0.62 (95% CI: 0.54-0.70, P=0.003), with an optimal cut-off point of 15.02 (sensitivity, 86.2%; specificity, 72.5%; positive predictive value, 74.3%; negative predictive value, 83.4%). CONCLUSIONS: The new discongruence index may be useful tool to predict PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino
4.
Echocardiography ; 35(11): 1827-1834, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30151866

RESUMEN

INTRODUCTION: The quantitative measurement of the left ventricle by echocardiography is a fundamental tool in the diagnosis and prognosis of acquired and congenital diseases in the pediatric population. The objective of this study was to validate an automated three-dimensional adaptive analytic echocardiographic algorithm, the so-called Heart Model® (HM) in the pediatric population, using as comparators the left atrial and left ventricular volumes and left ventricular ejection fraction obtained by means of conventional 2D and 3D echocardiography. METHODS: Pilot study, where a population comprised of 75 consecutive patients aged 6-17 years who attended a pediatric cardiology clinic, was evaluated. Every patient underwent a conventional 2D and 3D echocardiography and an analysis using HM. Conventional 3D echo was used as the reference method. RESULTS: Seventy-five patients were analyzed. Mean age was 11.2 (4.0) years (52.2% women). The intraclass correlation coefficient of HM vs 2D echo was poor, but it was good for the agreement between HM and 3D echo for left ventricular end-diastolic volume (ICC: 0.98; 95% CI: 0.97-0.99; P < 0.001), left ventricular end-systolic volume ICC: 0.98; 95% CI: 0.96-0.99; P = 0.001), and left ventricular ejection fraction (ICC: 0.87; 95% CI: 0.78-0.92; P < 0.001). The agreement was also good for the three parameters when the analysis was performed according to body weight. CONCLUSIONS: Heart Model® is a feasible and accurate tool for the evaluation of left atrial and left ventricular volumes and left ventricular ejection fraction in pediatric population aged above 6 years.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Adolescente , Algoritmos , Niño , Ecocardiografía/métodos , Estudios de Evaluación como Asunto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados
5.
Circulation ; 131(24): 2114-9, 2015 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-25888682

RESUMEN

BACKGROUND: Aortic dissection type A is a disease with high mortality. Iatrogenic aortic dissection after interventional procedures is infrequent, and prognostic data are scarce. Our objective was to analyze its incidence, patient profile, and long-term prognosis. METHODS AND RESULTS: Between 2000 and 2014, we retrospectively analyzed 74 patients with dissection of the ascending aorta. Clinical and procedural data were reviewed, and later, we performed a prospective clinical follow-up by telephone or in the office. The incidence of aortic dissection was 0.06%. Our patients, predominantly male (67.6%), had a mean age of 66.9±10.8 years. With multiple cardiovascular risk factors, the main reason for cardiac catheterization was an acute coronary syndrome (n=54). The complication was detected acutely in all, trying to engage the right coronary artery in 47 and the left main artery in 30 and after other maneuvers in 2, mostly complex therapeutic procedures (78.4%). A coronary artery was involved in 45 patients (60.8%). Thirty-five patients underwent an angioplasty and stent implantation; 3 had cardiac surgery; and 36 were managed conservatively. Two patients died of cardiogenic shock after the dissection. After a median follow-up of 51.2 months (range, 16.4-104.8 months), none of the remaining patients developed complications as a result of the dissection, progression, ischemia, pain, or dissection recurrence. CONCLUSIONS: Iatrogenic catheter dissection of the aorta is a rare complication that carries an excellent short- and long-term prognosis with the adoption of a conservative approach. When a coronary artery is involved as an entry point, it usually can be safely sealed with a stent with good long-term outcomes.


Asunto(s)
Aorta/lesiones , Aneurisma de la Aorta/etiología , Disección Aórtica/etiología , Cateterismo Cardíaco/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Síndrome Coronario Agudo/complicaciones , Síndrome Coronario Agudo/diagnóstico , Anciano , Disección Aórtica/epidemiología , Disección Aórtica/cirugía , Disección Aórtica/terapia , Anticoagulantes/efectos adversos , Aneurisma de la Aorta/epidemiología , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/terapia , Bases de Datos Factuales , Europa (Continente)/epidemiología , Femenino , Fibrinolíticos/efectos adversos , Estudios de Seguimiento , Humanos , Enfermedad Iatrogénica , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Stents , Resultado del Tratamiento
6.
J Thromb Thrombolysis ; 39(4): 452-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25052832

RESUMEN

Takotsubo cardiomyopathy (TK) includes a transient left ventricular dysfunction without obstructive coronary disease, sometimes after stressful situations with elevated cathecolamines. Since catecholamines activate platelets we aimed to study the platelet influence in a TK setting. We included 32 patients with a TK diagnosis, 13 with an acute coronary syndrome (ACS) and 18 healthy volunteers. Once consent informed was obtained, blood samples were extracted and processed (at admission and after 3 months follow-up). Clinical, ecg, echocardiographic and angiographic features were thoroughly recorded.Previous treatment before admission was similar between groups. No differences were observed in clinical features or any of the acute markers studied regarding platelet reactivity between TK compared to ACS. After follow-up, aggregation levels and platelet reactivity showed differences, mainly due to the antithrombotic therapy prescribed at discharge, but similar to volunteers. Circulating epinephrine during the acute phase was significantly higher in TK (p < 0.001). Patients with higher levels of epinephrine had elevated platelet activation and aggregation after 3 months. No differences were observed in Takotsubo acute platelet aggregation compared to patients with ACS, in spite of higher blood levels of adrenaline. Takotsubo patients had elevated platelet aggregation and activation compared with ACS patients at 3 months follow-up because they were less frequently on chronic clopidogrel and ASA. However, they had similar platelet aggregation and activation levels to healthy volunteers despite treatment with low-dose ASA. Takotsubo patients who had higher levels of adrenaline in the acute phase displayed increased platelet reactivity during follow-up.


Asunto(s)
Plaquetas/metabolismo , Epinefrina/sangre , Agregación Plaquetaria , Sistema de Registros , Cardiomiopatía de Takotsubo/sangre , Síndrome Coronario Agudo/sangre , Síndrome Coronario Agudo/tratamiento farmacológico , Anciano , Anciano de 80 o más Años , Clopidogrel , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Pruebas de Función Plaquetaria , Estudios Prospectivos , Cardiomiopatía de Takotsubo/tratamiento farmacológico , Ticlopidina/administración & dosificación , Ticlopidina/análogos & derivados
8.
Eur Heart J Case Rep ; 8(5): ytae219, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38745731

RESUMEN

Background: Intramyocardial dissection (ID) is an extremely rare myocardial infarction mechanical complication. Although both clinical and imaging assessment of this rare condition remains a challenge, recent multimodality imaging techniques may help to confirm and to assess the progressive nature of the disease. Diagnosis may be reached in different stages, from as early as the intramyocardial dissecting haematoma to the severe false-pseudoaneurysm. Case summary: This series describes five cases of ID and provides insights into imaging findings and clinical course of this extremely uncommon condition. Our patients represented a wide range of clinical stages, from asymptomatic course to cardiogenic shock. The imaging diagnostic approach was very different from case to case and involved techniques such as echocardiography, cardiac CT, and cardiac magnetic resonance. Discussion: Intramyocardial dissection is a challenging condition in terms of diagnosis and clinical management associated with high morbidity and mortality. Furthermore, the different nomenclature found in the literature may be confusing. This case series supports the need of a terminology standardization and a multimodal imaging approach, which might be determinant for an accurate differential diagnosis and a suitable therapeutic management.

9.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38844072

RESUMEN

INTRODUCTION AND OBJECTIVES: There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient. METHODS: A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient. RESULTS: We analyzed data from 167 patients. The mean age was 76±10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89±0.60 cm2 using pressure half-time (PHT), 2.87±0.83 cm2 using 3D planimetry, and the mean gradient was 3±1.19mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r=0.46, P<.001) than MVA obtained by PHT (r=0.19, P=.048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6 vs 19.7%, respectively). CONCLUSIONS: Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis.

10.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38521440

RESUMEN

INTRODUCTION AND OBJECTIVES: Diffuse homogeneous hypoechoic leaflet thickening, with a wavy leaflet motion documented by transesophageal echocardiography (TEE), has been described in some cases of prosthetic valve endocarditis (PVE) involving aortic bioprosthesis (AoBio-PVE). This echocardiographic finding has been termed valvulitis. We aimed to estimate the prevalence of valvulitis, precisely describe its echocardiographic characteristics, and determine their clinical significance in patients with AoBio-PVE. METHODS: From 2011 to 2022, 388 consecutive patients with infective endocarditis (IE) admitted to a tertiary care hospital were prospectively included in a multipurpose database. For this study, all patients with AoBio-PVE (n=86) were selected, and their TEE images were thoroughly evaluated by 3 independent cardiologists to identify all cases of valvulitis. RESULTS: The prevalence of isolated valvulitis was 12.8%, and 20.9% of patients had valvulitis accompanied by other classic echocardiographic findings of IE. A total of 9 out of 11 patients with isolated valvulitis had significant valve stenosis, whereas significant aortic valve regurgitation was documented in only 1 patient. Compared with the other patients with AoBio-PVE, cardiac surgery was less frequently performed in patients with isolated valvulitis (27.3% vs 62.7%, P=.017). In 4 out of 5 patients with valve stenosis who did not undergo surgery but underwent follow-up TEE, valve gradients significantly improved with appropriate antibiotic therapy. CONCLUSIONS: Valvulitis can be the only echocardiographic finding in infected AoBio and needs to be identified by imaging specialists for early diagnosis. However, this entity is a diagnostic challenge and additional imaging techniques might be required to confirm the diagnosis. Larger series are needed.

11.
Eur Heart J Cardiovasc Imaging ; 24(12): 1608-1617, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37315235

RESUMEN

AIMS: Cardiac damage staging has been postulated as a prognostic tool in patients undergoing transcatheter aortic valve replacement (TAVR). The aims of our study are (i) to validate cardiac damage staging systems previously described to stratify patients with aortic stenosis (AS), (ii) to identify independent risk factors for 1-year mortality in patients with severe AS undergoing TAVR, and (iii) to develop a novel staging model and compare its predictive performance to that of the above mentioned. METHODS AND RESULTS: Patients undergoing TAVR from 2017 to 2021 were included in a single-centre prospective registry. Transthoracic echocardiography was performed in all patients before TAVR. Logistic and Cox's regression analysis were used to identify predictors of 1-year all-cause mortality. In addition, patients were classified based on previously published cardiac damage staging systems, and the predictive performance of the different scores was measured.Four hundred and ninety-six patients (mean age 82.1 ± 5.9 years, 53% female) were included. Mitral regurgitation (MR), left ventricle global longitudinal strain (LV-GLS) and right ventricular-arterial coupling (RVAc) were independent predictors of all-cause 1-year mortality. A new classification system with four different stages was developed using LV-GLS, MR, and RVAc. The area under the receiver operating characteristic curve was 0.66 (95% confidence interval 0.63-0.76), and its predictive performance was superior compared with the previously published systems (P < 0.001). CONCLUSION: Cardiac damage staging might have an important role in patients' selection and better timing for TAVR. A model that includes LV-GLS, MR, and RVAc may help to improve prognostic stratification and contribute to better selection of patients undergoing TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/cirugía , Ventrículos Cardíacos/cirugía , Función Ventricular Izquierda , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Insuficiencia de la Válvula Mitral/cirugía , Factores de Riesgo , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
12.
Coron Artery Dis ; 34(3): 167-176, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36762665

RESUMEN

BACKGROUND: Cardiac computed tomography angiography (CCTA) is precise in noninvasive coronary atherosclerosis characterization but its value in the diagnosis of intracoronary thrombus remains unknown. Therefore, our aim was to evaluate CCTA for intracoronary thrombus and stenosis detection in patients with acute coronary syndromes with high thrombus burden selected for a deferred stenting strategy. METHODS: We systematically performed a CCTA in consecutive patients following a deferred stenting strategy, 24 h before the scheduled repeated coronary angiography including optical coherence tomography (OCT) imaging. Intracoronary thrombus and residual stenosis were blindly and independently evaluated by both techniques. Agreement was determined per lesion using the weighted Kappa ( K ) coefficient and absolute intraclass correlation coefficient (ICC). A stratified analysis according to OCT-detected thrombus burden was also performed. RESULTS: Thirty lesions in 28 consecutive patients were analyzed. Concordance between CCTA and repeated coronary angiography in thrombus detection was good ( K = 0.554; P < 0.001), but both showed poor agreement with OCT. CCTA needed >11.5% thrombus burden on OCT to obtain adequate diagnostic accuracy. The lesions detected by angiography were more frequently classified as red thrombus (76.5 vs. 33.3%; P = 0.087) on OCT. CCTA showed an excellent concordance with coronary angiography in diameter measurement (ICC = 0.85; P < 0.001) and was able to identify all the patients with severe residual stenosis. CONCLUSIONS: Although CCTA showed just a good concordance with angiography in intracoronary thrombus detection, the agreement in residual stenosis was excellent. Thus, in patients with a high-thrombus burden selected for a deferred stenting strategy CCTA may substitute repeat angiography.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Trombosis Coronaria , Humanos , Angiografía por Tomografía Computarizada , Estudios Prospectivos , Constricción Patológica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Angiografía Coronaria/métodos , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/terapia , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Valor Predictivo de las Pruebas
13.
J Clin Med ; 12(24)2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38137816

RESUMEN

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

14.
J Clin Med ; 12(12)2023 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-37373808

RESUMEN

BACKGROUND: The timing and selection of optimal candidates for mitral transcatheter edge-to-edge valve repair remains to be fully determined, especially in cases with severely depressed left ventricular ejection fraction (LVEF). The objective of this study is to evaluate the prognostic value of myocardial strain (LVGLS) in this setting. METHODS: Retrospectively, 172 consecutive patients with LVEF ≤40% and severe MR treated with MitraClip were included. Four groups were generated according to the LVEF (<30% or ≥30%) and median LVGLS. The primary end-point was cardiovascular mortality. RESULTS: Procedural success was high (96.5%) and complications were rare. At one-year follow-up, 82.5% of patients maintained MR grade ≤2, 79.2% were at a NYHA class ≤II and a reduction of 80% in heart failure admissions was observed in all groups. Interestingly, among patients with a more depressed LVEF, LVGLS was found to be an independent predictor for cardiovascular mortality (HR: 3.3; 95% CI: 1.1-10, p = 0.023). CONCLUSIONS: Mitral valve repair with MitraClip is safe and it improves the mid-term functional class of patients regardless of LVEF. LVGLS can help in the selection of optimal candidates and timing for this procedure, as well as in the recognition of those patients with worse prognoses.

18.
Interv Cardiol ; 16: e28, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34721667

RESUMEN

Transcatheter aortic valve replacement (TAVR) is an established treatment for patients with symptomatic severe aortic stenosis. In recent years, an emphasis has been placed on simplification of the procedure. Balloon predilation was initially considered a mandatory step to cross and prepare the stenotic aortic valve, but several studies demonstrated the feasibility of performing TAVR without balloon valvuloplasty. Balloon postdilation of the implanted valve is sometimes required to optimise results, although many patients do not require this step. Contemporary consensus advocates an individualised approach to TAVR procedures and so balloon pre- and post-dilation are performed selectively. This review aims to outline the advantages and disadvantages of balloon pre- and post-dilation and to identify the scenarios in which they are required during TAVR procedures.

20.
Curr Opin Cardiol ; 24(5): 415-9, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19550310

RESUMEN

PURPOSE OF REVIEW: Since the last few years, three-dimensional echocardiography (3DE) has become an accurate tool for mitral stenosis assessment. We will review the latest developments of 3DE in this matter. RECENT FINDINGS: Accuracy of 3DE planimetry is superior to the accuracy of the invasive Gorlin's method for mitral valve area (MVA) measurements when a median value obtained from two-dimensional planimetry, pressure half-time, and proximal isovelocity surface area method is used as the gold standard. 3DE improves MVA measurement particularly in less experienced operators compared with experienced operators. 3DE also improves the measurement of MVA in patients with calcific mitral stenosis by means of colour planimetry of the flow stream. Comparison of mitral valve volumes measured by 3DE in patients with critical and without critical stenosis has shown significantly larger volumes in patients with critical stenosis. SUMMARY: Currently, there is sufficient evidence that 3DE is superior to two-dimensional echocardiography and may be routinely used in the quantification of the MVA in mitral stenosis. In the coming years, 3DE might replace Gorlin's method as the gold standard for MVA quantification and may eventually make cardiac catheterization unnecessary.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Estenosis de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Ecocardiografía , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA