Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Nature ; 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867038

RESUMEN

Directed cell migration is driven by the front-back polarization of intracellular signalling1-3. Receptor tyrosine kinases and other inputs activate local signals that trigger membrane protrusions at the front2,4-6. Equally important is a long-range inhibitory mechanism that suppresses signalling at the back to prevent the formation of multiple fronts7-9. However, the identity of this mechanism is unknown. Here we report that endoplasmic reticulum-plasma membrane (ER-PM) contact sites are polarized in single and collectively migrating cells. The increased density of these ER-PM contacts at the back provides the ER-resident PTP1B phosphatase more access to PM substrates, which confines receptor signalling to the front and directs cell migration. Polarization of the ER-PM contacts is due to microtubule-regulated polarization of the ER, with more RTN4-rich curved ER at the front and more CLIMP63-rich flattened ER at the back. The resulting ER curvature gradient leads to small and unstable ER-PM contacts only at the front. These contacts flow backwards and grow to large and stable contacts at the back to form the front-back ER-PM contact gradient. Together, our study suggests that the structural polarity mediated by ER-PM contact gradients polarizes cell signalling, directs cell migration and prolongs cell migration.

2.
Nat Methods ; 21(4): 562-565, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38238558

RESUMEN

Imaging large fields of view at a high magnification requires tiling. Transmission electron microscopes typically have round beam profiles; therefore, tiling across a large area is either imperfect or results in uneven exposures, a problem for dose-sensitive samples. Here, we introduce a square electron beam that can easily be retrofitted in existing microscopes, and demonstrate its application, showing that it can tile nearly perfectly and deliver cryo-electron microscopy imaging with a resolution comparable to conventional set-ups.


Asunto(s)
Microscopía por Crioelectrón , Microscopía por Crioelectrón/métodos , Microscopía Electrónica de Transmisión
3.
J Struct Biol ; 215(3): 107967, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37105276

RESUMEN

This paper introduces OpenFIBSEM, a universal API to control Focused Ion Beam Scanning Electron Microscopes (FIBSEM). OpenFIBSEM aims to improve the programmability and automation of electron microscopy workflows in structural biology research. The API is designed to be cross-platform, composable, and extendable: allowing users to use any portion of OpenFIBSEM to develop or integrate with other software tools. The package provides core functionality such as imaging, movement, milling, and manipulator control, as well as system calibration, alignment, and image analysis modules. Further, a library of reusable user interface components integrated with napari is provided, ensuring easy and efficient application development. OpenFIBSEM currently supports ThermoFisher and TESCAN hardware, with support for other manufacturers planned. To demonstrate the improved automation capabilities enabled by OpenFIBSEM, several example applications that are compatible with multiple hardware manufacturers are discussed. We argue that OpenFIBSEM provides the foundation for a cross-platform operating system and development ecosystem for FIBSEM systems. The API and applications are open-source and available on GitHub (https://github.com/DeMarcoLab/fibsem).


Asunto(s)
Ecosistema , Programas Informáticos , Microscopía , Automatización , Procesamiento de Imagen Asistido por Computador
4.
Nat Mater ; 21(1): 74-80, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34556828

RESUMEN

Piezoelectrics interconvert mechanical energy and electric charge and are widely used in actuators and sensors. The best performing materials are ferroelectrics at a morphotropic phase boundary, where several phases coexist. Switching between these phases by electric field produces a large electromechanical response. In ferroelectric BiFeO3, strain can create a morphotropic-phase-boundary-like phase mixture and thus generate large electric-field-dependent strains. However, this enhanced response occurs at localized, randomly positioned regions of the film. Here, we use epitaxial strain and orientation engineering in tandem-anisotropic epitaxy-to craft a low-symmetry phase of BiFeO3 that acts as a structural bridge between the rhombohedral-like and tetragonal-like polymorphs. Interferometric displacement sensor measurements reveal that this phase has an enhanced piezoelectric coefficient of ×2.4 compared with typical rhombohedral-like BiFeO3. Band-excitation frequency response measurements and first-principles calculations provide evidence that this phase undergoes a transition to the tetragonal-like polymorph under electric field, generating an enhanced piezoelectric response throughout the film and associated field-induced reversible strains. These results offer a route to engineer thin-film piezoelectrics with improved functionalities, with broader perspectives for other functional oxides.

5.
Nano Lett ; 22(16): 6501-6508, 2022 08 24.
Artículo en Inglés | MEDLINE | ID: mdl-35926226

RESUMEN

New high-resolution imaging methods for biological samples such as atom probe tomography (APT), facilitated by the invention of laser-pulsed atom probes and cryo-transfer procedures, have recently emerged. However, ensuring the vitreous state of the fabricated aqueous needle-shaped APT samples remains a challenge despite it being crucial for characterizing biomolecules such as proteins and cellular architectures in their near-native state. Our work investigated three potential approaches: (1) open microcapillary (OMC) method, (2) high-pressure freezing method (HPF), and (3) graphene encapsulation method. Diffraction patterns of the needle specimens acquired by cryo-TEM have demonstrated the vitreous state of the ice needles, although limited to the tip regions, has been achieved with the three proposed approaches. With the capability to prepare vitreous ice needles from hydrated samples of up to ∼200 µm thickness (HPF), combined use of the three approaches opens new avenues for future near-atomic imaging of biological cells in their near-native state.


Asunto(s)
Hielo , Agua , Microscopía por Crioelectrón/métodos , Congelación
6.
J Struct Biol ; 210(2): 107488, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32126263

RESUMEN

Cryo-transmission electron tomography (cryo-ET) in association with cryo-focused ion beam (cryo-FIB) milling enables structural biology studies to be performed directly within the cellular environment. Cryo-preserved cells are milled and a lamella with a typical thickness of 200-300 nm provides an electron transparent window suitable for cryo-ET imaging. Cryo-FIB milling is an effective method, but it is a tedious and time-consuming process, which typically results in ~10 lamellae per day. Here, we introduce an automated method to reproducibly prepare cryo-lamellae on a grid and reduce the amount of human supervision. We tested the routine on cryo-preserved Saccharomyces cerevisiae, mammalian 293 T cells, and lysozyme protein crystals. Here we demonstrate that our method allows an increased throughput, achieving a rate of 5 lamellae/hour without the need to supervise the FIB milling. We demonstrate that the quality of the lamellae is consistent throughout the preparation and their compatibility with cryo-ET analyses.


Asunto(s)
Microscopía por Crioelectrón/métodos , Microscopía Electrónica de Transmisión/métodos , Animales , Tomografía con Microscopio Electrónico/métodos , Humanos
7.
Anal Chem ; 92(15): 10725-10732, 2020 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-32627542

RESUMEN

The development of protocols for bio/chemical reaction requires alternate dispensing and mixing steps. While most microfluidic systems use the opening of additional parts of the channel to allow the ingress of fixed volumes of fluid, this requires knowledge of the protocol before the design of the chip. Our approach of using a microfluidic valve to regulate the flow into an initially empty cavity allows for on-chip protocol development and refinement. Mixing is provided by way of surface acoustic wave excitation; this high-frequency vibration causes steady-state streaming flows. We show that capacitive sensing can be used to measure fluid levels, even if multiple fluid types are used, such that nanoliter dispensing accuracy is achieved. Also, the capacitive readout can be used to establish mixing quality and to monitor temperature fluctuations. These capabilities allow for protocols to be conducted without optical assessment and thus will allow for multiplexing, such that reactions could be conducted, simultaneously, in multiple chambers across a chip.

8.
Opt Express ; 28(8): 12174-12188, 2020 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-32403716

RESUMEN

Optical elements rely on refraction, diffraction, or reflection for light manipulation. Fusing diffractive and refractive functions in a single element provides an extra layer of control over the wave propagation, allowing complex beam shaping through self-aligned, monolithic and miniaturized optics. Using gray-scale lithography with high-current focused Xe ion-beams, we realized hybrid refractive-diffractive micro-axicons that feature diffractive gratings engraved on their conical surfaces. Furthermore, we fabricated these devices in lithium niobate, which is a challenging piezo/optoelectronic material for processing with an as-yet unexploited potential in optical applications. The curvilinear surfaces of fabricated micro-axicons with a 230-µm diameter were engraved with diffraction linear and circular gratings of various depths (<400 nm), and the optical performance of these components was characterized, showing excellent agreement with theoretical expectations. The fusing of diffractive elements with carrier refractive surfaces introduces additional or enhanced device functionalities, such as beam multiplexing and resolution improvement. The potential applications of such monolithic and miniaturized hybrid micro-optical components include beamshaping for fluorescence microscopy.

9.
J Struct Biol ; 203(2): 94-101, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29630922

RESUMEN

Cryo-Electron Microscopy (cryo-EM) has become an invaluable tool for structural biology. Over the past decade, the advent of direct electron detectors and automated data acquisition has established cryo-EM as a central method in structural biology. However, challenges remain in the reliable and efficient preparation of samples in a manner which is compatible with high time resolution. The delivery of sample onto the grid is recognized as a critical step in the workflow as it is a source of variability and loss of material due to the blotting which is usually required. Here, we present a method for sample delivery and plunge freezing based on the use of Surface Acoustic Waves to deploy 6-8 µm droplets to the EM grid. This method minimises the sample dead volume and ensures vitrification within 52.6 ms from the moment the sample leaves the microfluidics chip. We demonstrate a working protocol to minimize the atomised volume and apply it to plunge freeze three different samples and provide proof that no damage occurs due to the interaction between the sample and the acoustic waves.


Asunto(s)
Acústica , Microscopía por Crioelectrón/métodos , Manejo de Especímenes/métodos , Congelación , Microfluídica , Vitrificación
10.
Retrovirology ; 15(1): 23, 2018 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-29471854

RESUMEN

Cryo-electron microscopy has undergone a revolution in recent years and it has contributed significantly to a number of different areas in biological research. In this manuscript, we will describe some of the recent advancements in cryo-electron microscopy focussing on the advantages that this technique can bring rather than on the technology. We will then conclude discussing how the field of retrovirology has benefited from cryo-electron microscopy.


Asunto(s)
Microscopía por Crioelectrón , Retroviridae/fisiología , Retroviridae/ultraestructura , Animales , Microscopía por Crioelectrón/métodos , Humanos , Imagenología Tridimensional , Virión/ultraestructura
11.
Opt Express ; 26(10): 13647-13655, 2018 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-29801387

RESUMEN

Focused ion beam (FIB) systems based on high brightness plasma ion sources are becoming largely diffuse in material and semiconductor research, thanks to the higher current densities and milling rates provided by noble gas ions (e.g., Xe) compared with traditional liquid metal Ga FIBs. In this paper, we demonstrate the feasibility of a rapid, direct milling of microlenses in glass substrates using high current Xe plasma FIB. We present quantitative analyses of roughness and profile of microlenses with diameters up to 230-µm and focal distances between 7 mm and 1.4 mm. We characterized the performance of the lenses by mapping the transmitted intensity through the lenses, by forming an image of a resolution object by scanning the focused spot and collecting the transmitted intensity, and in full-field imaging experiments. The results indicate the applicability of plasma focused ion beam systems for direct writing in glass of high-quality micro-optical elements with diffraction-limited focusing.

12.
Opt Express ; 26(24): 32324-32331, 2018 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-30650693

RESUMEN

The high refractive index of lithium niobate crystal (n = 2.2) and the highly transparent range (300-5000 nm), makes it a perfect material for refractive lenses and other types of micro-optical elements. This material already finds extensive use in waveguides and photonic crystals, however, little work has been done on producing refractive optical components in lithium niobate, presumably due to the challenges associated with its fragility and difficulties in three-dimensional micromachining. In this study, we fabricated high-quality refractive micro-lenses and micro-axicons with low surface roughness (< λvis / 20), with 220 µm diameters and sag heights up to 22 µm in single-crystal LN using focused Xe beam milling. Xe ion beam milling is a flexible and rapid technique allowing realization of complex three-dimensional surface reliefs directly in lithium niobate. We characterized the optical performance of the fabricated elements showing sub-µm focusing capabilities of both the lenses and axicons.

13.
Nature ; 487(7407): 385-9, 2012 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-22722831

RESUMEN

The assembly of retroviruses such as HIV-1 is driven by oligomerization of their major structural protein, Gag. Gag is a multidomain polyprotein including three conserved folded domains: MA (matrix), CA (capsid) and NC (nucleocapsid). Assembly of an infectious virion proceeds in two stages. In the first stage, Gag oligomerization into a hexameric protein lattice leads to the formation of an incomplete, roughly spherical protein shell that buds through the plasma membrane of the infected cell to release an enveloped immature virus particle. In the second stage, cleavage of Gag by the viral protease leads to rearrangement of the particle interior, converting the non-infectious immature virus particle into a mature infectious virion. The immature Gag shell acts as the pivotal intermediate in assembly and is a potential target for anti-retroviral drugs both in inhibiting virus assembly and in disrupting virus maturation. However, detailed structural information on the immature Gag shell has not previously been available. For this reason it is unclear what protein conformations and interfaces mediate the interactions between domains and therefore the assembly of retrovirus particles, and what structural transitions are associated with retrovirus maturation. Here we solve the structure of the immature retroviral Gag shell from Mason-Pfizer monkey virus by combining cryo-electron microscopy and tomography. The 8-Å resolution structure permits the derivation of a pseudo-atomic model of CA in the immature retrovirus, which defines the protein interfaces mediating retrovirus assembly. We show that transition of an immature retrovirus into its mature infectious form involves marked rotations and translations of CA domains, that the roles of the amino-terminal and carboxy-terminal domains of CA in assembling the immature and mature hexameric lattices are exchanged, and that the CA interactions that stabilize the immature and mature viruses are almost completely distinct.


Asunto(s)
Cápside/ultraestructura , Microscopía por Crioelectrón , Virus del Mono Mason-Pfizer/ultraestructura , Modelos Moleculares , Cápside/metabolismo , Estructura Terciaria de Proteína , Ensamble de Virus
16.
Biophys J ; 110(4): 860-9, 2016 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-26769364

RESUMEN

The development of cryo-focused ion beam (cryo-FIB) for the thinning of frozen-hydrated biological specimens enabled cryo-electron tomography (cryo-ET) analysis in unperturbed cells and tissues. However, the volume represented within a typical FIB lamella constitutes a small fraction of the biological specimen. Retaining low-abundance and dynamic subcellular structures or macromolecular assemblies within such limited volumes requires precise targeting of the FIB milling process. In this study, we present the development of a cryo-stage allowing for spinning-disk confocal light microscopy at cryogenic temperatures and describe the incorporation of the new hardware into existing workflows for cellular sample preparation by cryo-FIB. Introduction of fiducial markers and subsequent computation of three-dimensional coordinate transformations provide correlation between light microscopy and scanning electron microscopy/FIB. The correlative approach is employed to guide the FIB milling process of vitrified cellular samples and to capture specific structures, namely fluorescently labeled lipid droplets, in lamellas that are 300 nm thick. The correlation procedure is then applied to localize the fluorescently labeled structures in the transmission electron microscopy image of the lamella. This approach can be employed to navigate the acquisition of cryo-ET data within FIB-lamellas at specific locations, unambiguously identified by fluorescence microscopy.


Asunto(s)
Tomografía con Microscopio Electrónico/métodos , Imagenología Tridimensional/métodos , Tomografía con Microscopio Electrónico/instrumentación , Marcadores Fiduciales , Células HeLa , Humanos , Imagenología Tridimensional/instrumentación , Microscopía Fluorescente
17.
J Virol ; 88(14): 7893-903, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24789788

RESUMEN

Actin and actin-binding proteins are incorporated into HIV-1 particles, and F-actin has been suggested to bind the NC domain in HIV-1 Gag. Furthermore, F-actin has been frequently observed in the vicinity of HIV-1 budding sites by cryo-electron tomography (cET). Filamentous structures emanating from viral buds and suggested to correspond to actin filaments have been observed by atomic force microscopy. To determine whether the NC domain of Gag is required for actin association with viral buds and for actin incorporation into HIV-1, we performed comparative analyses of virus-like particles (VLPs) obtained by expression of wild-type HIV-1 Gag or a Gag variant where the entire NC domain had been replaced by a dimerizing leucine zipper [Gag(LZ)]. The latter protein yielded efficient production of VLPs with near-wild-type assembly kinetics and size and exhibited a regular immature Gag lattice. Typical HIV-1 budding sites were detected by using cET in cells expressing either Gag or Gag(LZ), and no difference was observed regarding the association of buds with the F-actin network. Furthermore, actin was equally incorporated into wild-type HIV-1 and Gag- or Gag(LZ)-derived VLPs, with less actin per particle observed than had been reported previously. Incorporation appeared to correlate with the relative intracellular actin concentration, suggesting an uptake of cytosol rather than a specific recruitment of actin. Thus, the NC domain in HIV-1 Gag does not appear to have a role in actin recruitment or actin incorporation into HIV-1 particles. Importance: HIV-1 particles bud from the plasma membrane, which is lined by a network of actin filaments. Actin was found to interact with the nucleocapsid domain of the viral structural protein Gag and is incorporated in significant amounts into HIV-1 particles, suggesting that it may play an active role in virus release. Using electron microscopy techniques, we previously observed bundles of actin filaments near HIV-1 buds, often seemingly in contact with the Gag layer. Here, we show that this spatial association is observed independently of the proposed actin-binding domain of HIV-1. The absence of this domain also did not affect actin incorporation and had a minor effect on the viral assembly rate. Furthermore, actin was not enriched in the virus compared to the average levels in the respective producing cell. Our data argue against a specific recruitment of actin to HIV-1 budding sites by the nucleocapsid domain of Gag.


Asunto(s)
Actinas/metabolismo , VIH-1/fisiología , Interacciones Huésped-Patógeno , Ensamble de Virus , Liberación del Virus , Productos del Gen gag del Virus de la Inmunodeficiencia Humana/metabolismo , Línea Celular , VIH-1/genética , Humanos , Nucleocápside/genética , Nucleocápside/metabolismo , Estructura Terciaria de Proteína , Productos del Gen gag del Virus de la Inmunodeficiencia Humana/genética
18.
Curr Opin Struct Biol ; 87: 102864, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38901373

RESUMEN

Cryogenic-focused ion beam (cryo-FIB) instruments became essential for high-resolution imaging in cryo-preserved cells and tissues. Cryo-FIBs use accelerated ions to thin samples that would otherwise be too thick for cryo-electron microscopy (cryo-EM). This allows visualizing cellular ultrastructures in near-native frozen hydrated states. This review describes the current state-of-the-art capabilities of cryo-FIB technology and its applications in structural cell and tissue biology. We discuss recent advances in instrumentation, imaging modalities, automation, sample preparation protocols, and targeting techniques. We outline remaining challenges and future directions to make cryo-FIB more precise, enable higher throughput, and be widely accessible. Further improvements in targeting, efficiency, robust sample preparation, emerging ion sources, automation, and downstream electron tomography have the potential to reveal intricate molecular architectures across length scales inside cells and tissues. Cryo-FIB is poised to become an indispensable tool for preparing native biological systems in situ for high-resolution 3D structural analysis.

19.
bioRxiv ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38328036

RESUMEN

CryoEM democratization is hampered by access to costly plunge-freezing supplies. We introduce methods, called CryoCycle, for reliably blotting, vitrifying, and reusing clipped cryoEM grids. We demonstrate that vitreous ice may be produced by plunging clipped grids with purified proteins into liquid ethane and that clipped grids may be reused several times for different protein samples. Furthermore, we demonstrate the vitrification of thin areas of cells prepared on gold-coated, pre-clipped grids.

20.
bioRxiv ; 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38405976

RESUMEN

The compaction of chromatin is a prevalent paradigm in gene repression. Chromatin compaction is commonly thought to repress transcription by restricting chromatin accessibility. However, the spatial organisation and dynamics of chromatin compacted by gene-repressing factors are unknown. Using cryo-electron tomography, we solved the threedimensional structure of chromatin condensed by the Polycomb Repressive Complex 1 (PRC1) in a complex with CBX8. PRC1-condensed chromatin is porous and stabilised through multivalent dynamic interactions of PRC1 with chromatin. Mechanistically, positively charged residues on the internally disordered regions (IDRs) of CBX8 mask negative charges on the DNA to stabilize the condensed state of chromatin. Within condensates, PRC1 remains dynamic while maintaining a static chromatin structure. In differentiated mouse embryonic stem cells, CBX8-bound chromatin remains accessible. These findings challenge the idea of rigidly compacted polycomb domains and instead provides a mechanistic framework for dynamic and accessible PRC1-chromatin condensates.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA