Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Audiol Neurootol ; 27(3): 227-234, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34808626

RESUMEN

INTRODUCTION: The objective of this study was to assess the influence of postponing the first post-activation follow-up due to the COVID-19 pandemic on the aided sound field detection thresholds and speech recognition of cochlear implant (CI) users. METHODS: A retrospective review was performed at a tertiary referral center. Two groups of adult CI recipients were evaluated: (1) patients whose first post-activation follow-up was postponed due to COVID-19 closures (postponed group; n = 10) and (2) a control group that attended recommended post-activation follow-ups prior to the COVID-19 pandemic (control group; n = 18). For both groups, electric thresholds were estimated at initial activation based on comfort levels and were measured behaviorally at subsequent post-activation follow-ups. For the control group, behavioral thresholds were measured at the 1-month follow-up. For the postponed group, behavioral thresholds were not measured until 3 months post-activation since the 1-month follow-up was postponed. The aided pure-tone average (PTA) and word recognition results were compared between groups at the 3-month follow-up and at an interim visit 2-9 weeks later. RESULTS: At the 3-month follow-up, the postponed group had significantly poorer word recognition (23 vs. 42%, p = 0.027) and aided PTA (42 vs. 37 dB HL, p = 0.041) than the control group. No significant differences were observed between 3-month data from the control group and interim data from the postponed group. CONCLUSIONS: The postponed follow-up after CI activation was associated with poorer outcomes, both in terms of speech recognition and aided audibility. However, these detrimental effects were reversed following provision of an individualized map, with behaviorally measured electric threshold and comfort levels. While adult CI recipients demonstrate an improvement in speech recognition with estimated electric thresholds, the present results suggest that behavioral mapping within the initial weeks of device use may support optimal outcomes.


Asunto(s)
COVID-19 , Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Umbral Auditivo , Implantación Coclear/métodos , Estudios de Seguimiento , Humanos , Pandemias , Percepción del Habla/fisiología
2.
Am J Otolaryngol ; 42(5): 103130, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34242952

RESUMEN

PURPOSE: To examine how patients self-administer ear drops, ascertain their perceived difficulty in performing the task and determine if they are able to deliver the correct dosage. MATERIALS AND METHODS: This is a prospective cohort study performed in an otology outpatient clinic with twenty-one subjects with a condition requiring ototopical antibiotics. The number of ear drops applied as well as skills performed during ear drop application was measured. Patient reported difficulty and confidence in application of ear drops data was also obtained. RESULTS: The mean number of drops applied was 2.91 ± 2.1 (target = 3 drops) with a large variance in drop application, range of 0.6 to 9.2 drops. If "correct dosage" is considered 85-115% of the intended dose, then almost half of patients, 47.6%, underdosed with 23.8% that over dosed. Patients reported that the average difficulty in applying drops to themselves was 3.6 (1 being easy and 10 being difficult). Patients reported a high confidence level in applying the correct dose of ear drops of 6.7 (1 being not confident and 10 being very confident). CONCLUSIONS: In our study of 21 patients self-administering ear drops, only 28.6% of patients were able to correctly apply the appropriate treatment dose, with almost half of patients underdosing. Questionnaire data indicated that most patients were unaware they were administering an incorrect dose. Inaccurate administration of ear drops could be problematic and lead to longer durations of symptoms, false treatment failures, and increased costs.


Asunto(s)
Antibacterianos/administración & dosificación , Ofloxacino/administración & dosificación , Otitis Externa/tratamiento farmacológico , Otitis Externa/psicología , Otitis Media Supurativa/tratamiento farmacológico , Otitis Media Supurativa/psicología , Pacientes/psicología , Autoadministración/psicología , Autoimagen , Administración Tópica , Formas de Dosificación , Femenino , Humanos , Instilación de Medicamentos , Masculino , Estudios Prospectivos , Encuestas y Cuestionarios
3.
Am J Otolaryngol ; 41(4): 102518, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32451290

RESUMEN

OBJECTIVE: Cochlear nerve preserving translabyrinthine vestibular schwannoma (VS) resection enables concurrent cochlear implantation. Implantation in patients with VS raises important concerns including the ability to undergo postoperative magnetic resonance imaging (MRI) monitoring of residual tumor growth or tumor recurrence, specifically with a retained magnet. We aim to assess the feasibility of MRI monitoring and the impact on image quality with retained cochlear implant (CI) magnets. METHODS: Retrospective review of post-operative head MRI scans in CI recipients with a retained CI magnet, after cochlear nerve preserving translabyrinthine excision of VS. The ability to visualize the ipsilateral and contralateral internal auditory canal (IAC) and cerebellopontine angle (CPA) were assessed. RESULTS: A total of eight surveillance head MRI were performed in six patients. In one case, in which the receiver was positioned lower, the view of the ipsilateral IAC and CPA was distorted. In all other cases, the views of both the ipsilateral and contralateral IAC and CPA were overall unimpaired. DISCUSSION: Imaging artifact only very rarely impedes adequate visualization of the ipsilateral IAC or CPA in CI recipients. In anticipation of the need for further IAC and CPA imaging, it would be advisable to place the receiver in an exaggerated superior-posterior position to further decrease obscuring artifact. Thus, serial monitoring of VS tumors can be performed safely with preservation of image quality with a retained receiver magnet. CONCLUSIONS: When placing the CI receiver-stimulator farther posterior-superiorly, excellent visualization of the IAC and CPA can be accomplished without significantly impairing the image quality.


Asunto(s)
Implantación Coclear/métodos , Nervio Coclear , Neoplasias de los Nervios Craneales/diagnóstico por imagen , Neoplasias de los Nervios Craneales/cirugía , Imagen por Resonancia Magnética/métodos , Neuroma Acústico/diagnóstico por imagen , Neuroma Acústico/cirugía , Tratamientos Conservadores del Órgano/métodos , Enfermedades del Nervio Vestibulococlear/diagnóstico por imagen , Enfermedades del Nervio Vestibulococlear/cirugía , Nervio Vestibulococlear/diagnóstico por imagen , Nervio Vestibulococlear/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Periodo Posoperatorio , Estudios Retrospectivos
4.
Am J Otolaryngol ; 39(5): 489-492, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29805061

RESUMEN

PURPOSE: Determine the effect of cochleostomy and facial recess packing on cochlear implant electrode distance from the modiolus. MATERIALS AND METHODS: Two otolaryngology residents (PGY5 and PGY6) and one attending ear surgeon performed electrode insertions on a human cochlea model using perimodiolar (Cochlear® Slim Modiolar 532™, CI532) and lateral wall electrodes (Cochlear® Slim Straight 522™, CI522) via a cochleostomy. Packing material was simulated using cotton and placed in the cochleostomy and facial recess under the following conditions: 1) inferior to the electrode, 2) superior, 3) both inferior and superior, and 4) no packing. Distance of the electrode from the modiolus at the proximal, middle, and distal basal turn of the cochlea were measured by photomicrograph analysis. RESULTS: Packing superior to the CI532 resulted in a significant decrease in distance from the modiolus at the middle and distal basal turn compared to the inferior condition, with the largest effect in the middle basal turn (0.25 mm vs. 1.92 mm, respectively, p < 0.001). For the CI522, packing superior similarly resulted in decreased distance to the modiolus when compared to the inferior packing condition at the middle and distal basal turn regions, with the largest effect in the middle basal turn (1.25 mm vs. 1.75 mm, respectively, p = 0.002). CONCLUSIONS: Packing of the cochleostomy site and facial recess has a significant effect on electrode distance from the modiolus in the middle and distal basal turn using a model of a human cochlea. Effects were more pronounced when using the perimodiolar (CI532) electrode.


Asunto(s)
Competencia Clínica , Implantación Coclear/métodos , Implantes Cocleares , Electrodos Implantados , Entrenamiento Simulado/métodos , Educación de Postgrado en Medicina/métodos , Humanos , Internado y Residencia/métodos , Modelos Anatómicos , Otolaringología/educación , Proyectos Piloto , Ventana Redonda/cirugía
5.
Am J Otolaryngol ; 38(4): 498-500, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28476442

RESUMEN

PURPOSE: Lateral osteotomies are important during rhinoplasty and represent a challenging technique that otolaryngology and plastic surgery trainees must learn. The approaches for osteotomies are difficult to teach as they are accomplished through tactile feedback. Trends in teaching and practice patterns of lateral osteotomies are poorly described in the literature, and this study aims to fill this knowledge gap. MATERIALS AND METHODS: Members of the American Academy of Facial Plastic and Reconstructive Surgery were surveyed to characterize surgeon preferences for intranasal versus percutaneous lateral osteotomies and understand how techniques are taught. RESULTS: Among surgeons who completed the survey (n=172), 87% reported that they "always" or "mostly" use intranasal lateral osteotomies whereas only 8% "always" or "mostly" use percutaneous approaches. There is no significant trend towards changing osteotomy techniques when teaching trainees. Only 15% of respondents allow trainees to perform lateral osteotomies in more than half of operations. CONCLUSIONS: Most facial plastic surgeons prefer to use intranasal lateral osteotomies. However, many do not allow trainees to perform this critical step during rhinoplasty. This study has implications for both patient care and surgical education.


Asunto(s)
Osteotomía/educación , Otolaringología/educación , Rinoplastia/educación , Humanos , Osteotomía/métodos , Pautas de la Práctica en Medicina , Rinoplastia/métodos
6.
Am J Otolaryngol ; 38(5): 526-528, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28532970

RESUMEN

OBJECTIVE: To increase otolaryngology resident experience with drilling and dissection of the internal auditory canal (IAC) via a translabyrinthine approach. STUDY DESIGN: Pilot study involving temporal bone education and drilling with completion of pre- and post-drilling surveys. METHODS: Participants observed an educational presentation on IAC anatomy and drilling, followed by manipulation of IAC nerves using a prosected cadaveric temporal bone. Participants then drilled the IAC and identified nerves using temporal bones with previously drilled mastoidectomies and labyrinthectomies. Pre- and post-drilling 5-point Likert-based surveys were completed. RESULTS: 7 participants were included in this study ranging in experience from PGY1 through PGY 5. The median number of times the IAC had been drilled previously was 0. Participants reported statistically significantly improved familiarity with the translabyrinthine approach after the session with median scores increasing from 2 to 3 (p=0.02), and a near-significant increase in familiarity with IAC anatomy with median scores increasing from 3 to 4 (p=0.06). Prior to the session, 71% of participants either disagreed or strongly disagreed that they had an idea of what the procedure would be like in a real operating room, whereas after the session 0% reported disagreement. 100% of participants were very satisfied with the overall experience. CONCLUSIONS: An educational session and temporal bone drilling experience using prosected bones significantly increased the reported familiarity with the translabyrinthine approach. Experiences such as this may enhance resident exposure to advanced lateral skull base approaches in a safe environment, and increase comprehension of the complex anatomic relationships of the IAC.


Asunto(s)
Competencia Clínica , Oído Interno/cirugía , Internado y Residencia , Procedimientos Quirúrgicos Otológicos/educación , Cadáver , Curriculum , Disección/educación , Femenino , Humanos , Masculino , Proyectos Piloto , Hueso Temporal/cirugía
7.
Am J Otolaryngol ; 38(4): 472-474, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28449823

RESUMEN

PURPOSE: There are no controlled prospective studies evaluating the effect of dominant handedness in left- and right-sided surgery in otolaryngology. Endoscopic microlaryngeal phonosurgery is an ideal procedure to assess technical aspects of handedness and laterality, due to anatomic symmetry. In this study, we analyzed (1) choice of surgical approach and (2) outcomes based on handedness and laterality in a microlaryngeal simulator. METHODS: Using a validated high-fidelity phonosurgery model, a prospective cohort of 19 expert laryngologists undertook endoscopic resection of a simulated vocal fold lesion. These resections were video-recorded and scored by 2 blinded expert laryngologists using a validated global rating scale, procedure-specific rating scale, and a hand preference analysis. RESULTS: There were 18 right-handed participants and 1 left-handed. 12 left and 7 right excisions were evaluated. Cronbach's alpha for inter-rater reliability was good (0.871, global scale; and 0.814, procedure-specific scale). Surgeons used their dominant hand 78.9% of the time for both incision and dissection. In cases where the non-dominant hand would have been preferred, surgeons used the non-dominant hand only 36.4% of the time for incision and dissection. Use of the non-dominant hand did not influence global or procedural rating (p=0.132 and p=0.459, respectively). CONCLUSIONS: In this simulation of microlaryngeal surgery, there were measurable differences in surgical approaches based on hand dominance, with surgeons preferring to cut and perform resection with the dominant hand despite limitations in the instrumentation and exposure. Regardless of hand preference, overall outcomes based on global rating and technique specific rating scales were not significantly different.


Asunto(s)
Lateralidad Funcional , Enfermedades de la Laringe/cirugía , Laringoscopía , Microcirugia , Desempeño Psicomotor , Animales , Humanos , Modelos Animales , Entrenamiento Simulado , Porcinos
8.
Laryngoscope ; 134(5): 2401-2404, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38149671

RESUMEN

OBJECTIVE: To detail a modified surgical technique for implantation of the Osia 2 Bone Conduction Hearing Aid (BCHA) system and to assess intra- and postoperative outcomes of this technique. METHODS: A retrospective review was performed for cases undergoing implantation of an Osia 2 BCHA at a tertiary academic medical center. Modifications were made to the surgical procedure including: horizontal or curvilinear incisions, placement of the osseointegrated screw slightly superior to the plane of the external auditory canal, and double layer wound closure. Data regarding outcomes including demographics, incision type, surgical time, drilling requirements, and complications were collected using the electronic medical record. RESULTS: A total of twenty-eight cases were evaluated with 57.1% and 42.9% utilizing horizontal and curved incisions, respectively. The median age for recipients was 43.1 years with six pediatric cases included in the study. Median operative time was 58 min (43-126 min). The majority of cases required minimal (60.7%) or no drilling (28.6%) with a significant increase in operative time for those requiring moderate drilling versus minimal to no drilling (F = 8.02, p = 0.002). There were no intraoperative complications. One (3.6%) postoperative seroma occurred which resolved with conservative management. CONCLUSION: The proposed modified surgical technique is a safe and effective method for implantation of the transcutaneous BCHA system with a low complication rate. Keys include incision design, implant placement, and two-layered closure to minimize wound tension. These modifications can improve ease of the procedure and reduce operative time. These techniques also appear to be applicable to the pediatric population. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:2401-2404, 2024.


Asunto(s)
Conducción Ósea , Audífonos , Humanos , Niño , Adulto , Implantación de Prótesis/métodos , Conducto Auditivo Externo/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Pérdida Auditiva Conductiva/cirugía , Pérdida Auditiva Conductiva/rehabilitación
9.
Laryngoscope ; 134(4): 1868-1873, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37767794

RESUMEN

OBJECTIVE: Determine variables that influence post-activation performance for cochlear implant (CI) recipients who lost low-frequency acoustic hearing. METHODS: A retrospective review evaluated CNC word recognition for adults with normal to moderately severe low-frequency hearing (preoperative unaided thresholds of ≤70 dB HL at 250 Hz) who were implanted between 2012 and 2021 at a tertiary academic center, lost functional acoustic hearing, and were fit with a CI-alone device. Performance scores were queried from the 1, 3, 6, 12, and 24-month post-activation visits. A linear mixed model evaluated the effects of age at implantation, array length (long vs. mid/short), and preoperative low-frequency hearing (normal to mild, moderate, and moderately severe) on speech recognition with a CI alone. RESULTS: 113 patients met the inclusion criteria. There was a significant main effect of interval (p < 0.001), indicating improved word recognition post-activation despite loss of residual hearing. There were significant main effects of age (p = 0.029) and array length (p = 0.038), with no effect of preoperative low-frequency hearing (p = 0.171). There was a significant 2-way interaction between age and array length (p = 0.018), indicating that older adults with mid/short arrays performed more poorly than younger adults with long lateral wall arrays when functional acoustic hearing was lost. CONCLUSION: CI recipients with preoperative functional low-frequency hearing experience a significant improvement in speech recognition with a CI alone as compared to preoperative performance-despite the loss of low-frequency hearing. Age and electrode array length may play a role in post-activation performance. These data have implications for the preoperative counseling and device selection for hearing preservation candidates. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:1868-1873, 2024.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Anciano , Percepción del Habla/fisiología , Audición , Pruebas Auditivas , Resultado del Tratamiento
10.
Laryngoscope ; 134(7): 3342-3348, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38345081

RESUMEN

OBJECTIVE: The study was conducted to evaluate the safety and efficacy of mild internal jugular (IJV) compression via an FDA approved compression collar for symptomatic treatment of venous pulsatile tinnitus. METHODS: This is a prospective study that recruited 20 adult patients with venous pulsatile tinnitus. Participants completed the Tinnitus Handicap Inventory (THI), were fitted with the collar, and rated symptom intensity on a 10-point tinnitus intensity scale before and during collar use. Once weekly for 4 weeks, they answered a survey quantifying days used, average tinnitus intensity before and after wearing the collar each day of use, and any safety concerns. Lastly, they completed an exit interview. The primary outcome was symptomatic relief, with secondary outcomes of safety, effect of treatment setting, effect of time, and quality of life assessed via nonparametric testing. RESULTS: 18 participants completed the study, and 276 paired daily before use/during use intensity scores were submitted. The median symptom intensity without the collar was 6 (IQR 4, 7), whereas with the collar it was 3 (IQR 2, 5), for a median symptomatic relief of 50%. The collar had a significant effect in reducing symptom intensity (p < 0.0001) and burden of illness via the THI (p < 0.0001). There was no effect of setting, frequency, or time on symptomatic relief with the collar. There were no adverse safety events reported aside from minor discomfort upon initial application. CONCLUSIONS: Venous compression collars offer acute symptom relief for patients with venous pulsatile tinnitus. Further study is needed to assess safety and efficacy of longitudinal use. LEVEL OF EVIDENCE: 4 Laryngoscope, 134:3342-3348, 2024.


Asunto(s)
Venas Yugulares , Acúfeno , Humanos , Acúfeno/terapia , Acúfeno/etiología , Femenino , Masculino , Estudios Prospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Adulto , Anciano , Calidad de Vida , Vendajes de Compresión
11.
Laryngoscope ; 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38656740

RESUMEN

OBJECTIVES: Research samples that are representative of patient populations are needed to ensure the generalizability of study findings. The primary aim was to assess the efficacy of a study design and recruitment strategy in obtaining a participant sample that was representative of the broader cochlear implant (CI) patient population at the CI center. A secondary aim was to review whether the CI recipient population was representative of the state population. METHODS: Demographic variables were compared for a research participant sample (n = 79) and the CI patient population (n = 338). The participant sample was recruited from the CI patient population. The study design included visits that were at the same location and frequency as the recommended clinical follow-up intervals. The demographics for the combined group (participant sample and patient population) were then compared to the reported demographics for the population in North Carolina. RESULTS: There were no significant differences between the participant sample and patient population for biological sex, age at implantation, racial distribution, socioeconomic position, degree of urbanization, or drive time to the CI center (p ≥ 0.086). The combined CI recipient population was significantly different from the North Carolina population for the distributions of race, ethnicity, and degree of urbanization (p < 0.001). CONCLUSION: The study design and recruitment strategy allowed for recruitment of a participant sample that was representative of the CI patient population. Disparities in access to cochlear implantation persist, as supported by the significant differences in the combined CI recipient population and the population for our state. LEVEL OF EVIDENCE: 3 Laryngoscope, 2024.

12.
Otol Neurotol ; 45(6): e460-e467, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38865720

RESUMEN

OBJECTIVE: Misplacement of electrode arrays in the internal auditory canal (IAC) presents a unique clinical challenge. Speech recognition is limited for cochlear implant (CI) users with misplaced arrays, and there are risks with revision surgery including facial and/or cochlear nerve injury. DATABASES REVIEWED: PubMed, Embase, and Scopus. METHODS: A literature search was performed from inception to September 2023. The search terms were designed to capture articles on misplaced arrays and the management options. Articles written in English that described cases of array misplacement into the IAC for children and adults were included. The level of evidence was assessed using Oxford Center for Evidence Based Medicine guidelines. Descriptive statistical analyses were performed. RESULTS: Twenty-eight cases of arrays misplaced in the IAC were identified. Thirteen (46%) were patients with incomplete partition type 3 (IP3), and 7 (25%) were patients with common cavity (CC) malformations. Most misplaced arrays were identified postoperatively (19 cases; 68%). Of these cases, 11 (58%) were managed with array removal. No facial nerve injuries were reported with revision surgery. Eight cases (42%) were left in place. Several underwent mapping procedures in an attempt improve the sound quality with the CI. CONCLUSION: Electrode array misplacement in the IAC is a rare complication that reportedly occurs predominately in cases with IP3 and CC malformations. Removal of misplaced arrays from the IAC reportedly has not been associated with facial nerve injuries. Cases identified with IAC misplacement postoperatively can potentially be managed with modified mapping techniques before proceeding with revision surgery.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Oído Interno , Humanos , Implantes Cocleares/efectos adversos , Implantación Coclear/efectos adversos , Implantación Coclear/métodos , Oído Interno/cirugía , Electrodos Implantados/efectos adversos , Reoperación/estadística & datos numéricos
13.
Laryngoscope Investig Otolaryngol ; 8(1): 296-302, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36846426

RESUMEN

Objectives: Access to cochlear implantation may be negatively influenced by extended travel time to a cochlear implant (CI) center or lower socioeconomic status (SES) for the individual. There is a critical need to understand the influence of these variables on patient appointment attendance for candidacy evaluations, and CI recipients' adherence to post-activation follow-up recommendations that support optimal outcomes. Methods: A retrospective chart review of adult patients referred to a CI center in North Carolina for initial cochlear implantation candidacy evaluation between April 2017 and July 2019 was conducted. Demographic and audiologic data were collected for each patient. Travel time was determined using geocoding. SES was proxied using ZCTA-level Social Deprivation Index (SDI) information. Independent samples t tests compared variables between those who did and did not attend the candidacy evaluation. Pearson correlations assessed the association of these variables and the duration of time between initial CI activation and return for first follow-up visit. Results: Three hundred and ninety patients met the inclusion criteria. There was a statistically significant difference between SDI of those who attended their candidacy evaluation versus those who did not. Age at referral or travel time did not show statistical significance between these two groups. There was no significant correlation with age at referral, travel time, or SDI with the duration of time (days) between initial activation and the 1-month follow-up. Conclusions: Our findings suggest that SES may influence a patient's ability to attend a cochlear implantation candidacy evaluation appointment and may further impact the decision to pursue cochlear implantation.Level of evidence: 4 - Case Series.

14.
Otol Neurotol ; 44(10): 1004-1010, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37758328

RESUMEN

OBJECTIVES: To investigate the incidence of electrode contacts within the functional acoustic hearing region in cochlear implant (CI) recipients and to assess its influence on speech recognition for electric-acoustic stimulation (EAS) users. STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: One hundred five CI recipients with functional acoustic hearing preservation (≤80 dB HL at 250 Hz). INTERVENTIONS: Cochlear implantation with a 24-, 28-, or 31.5-mm lateral wall electrode array. MAIN OUTCOME MEASURES: Angular insertion depth (AID) of individual contacts was determined from imaging. Unaided acoustic thresholds and AID were used to calculate the proximity of contacts to the functional acoustic hearing region. The association between proximity values and speech recognition in quiet and noise for EAS users at 6 months postactivation was reviewed. RESULTS: Sixty percent of cases had one or more contacts within the functional acoustic hearing region. Proximity was not significantly associated with speech recognition in quiet. Better performance in noise was observed for cases with close correspondence between the most apical contact and the upper edge of residual hearing, with poorer results for increasing proximity values in either the basal or apical direction ( r14 = 0.48, p = 0.043; r18 = -0.41, p = 0.045, respectively). CONCLUSION: There was a high incidence of electrode contacts within the functional acoustic hearing region, which is not accounted for with default mapping procedures. The variability in outcomes across EAS users with default maps may be due in part to electric-on-acoustic interference, electric frequency-to-place mismatch, and/or failure to stimulate regions intermediate between the most apical electrode contact and the functional acoustic hearing region.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Implantes Cocleares/efectos adversos , Implantación Coclear/métodos , Estimulación Acústica/métodos , Percepción del Habla/fisiología , Incidencia , Audición , Estimulación Eléctrica/métodos
15.
Laryngoscope ; 133(12): 3540-3547, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37078508

RESUMEN

OBJECTIVE: Comparison of acute speech recognition for cochlear implant (CI) alone and electric-acoustic stimulation (EAS) users listening with default maps or place-based maps using either a spiral ganglion (SG) or a new Synchrotron Radiation-Artificial Intelligence (SR-AI) frequency-to-place function. METHODS: Thirteen adult CI-alone or EAS users completed a task of speech recognition at initial device activation with maps that differed in the electric filter frequency assignments. The three map conditions were: (1) maps with the default filter settings (default map), (2) place-based maps with filters aligned to cochlear SG tonotopicity using the SG function (SG place-based map), and (3) place-based maps with filters aligned to cochlear Organ of Corti (OC) tonotopicity using the SR-AI function (SR-AI place-based map). Speech recognition was evaluated using a vowel recognition task. Performance was scored as the percent correct for formant 1 recognition due to the rationale that the maps would deviate the most in the estimated cochlear place frequency for low frequencies. RESULTS: On average, participants had better performance with the OC SR-AI place-based map as compared to the SG place-based map and the default map. A larger performance benefit was observed for EAS users than for CI-alone users. CONCLUSION: These pilot data suggest that EAS and CI-alone users may experience better performance with a patient-centered mapping approach that accounts for the variability in cochlear morphology (OC SR-AI frequency-to-place function) in the individualization of the electric filter frequencies (place-based mapping procedure). LEVEL OF EVIDENCE: 3 Laryngoscope, 133:3540-3547, 2023.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Inteligencia Artificial , Cóclea/anatomía & histología , Estimulación Acústica/métodos
16.
Am J Audiol ; 32(1): 251-260, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36800505

RESUMEN

PURPOSE: Cochlear implant (CI) recipients with hearing preservation experience significant improvements in speech recognition with electric-acoustic stimulation (EAS) as compared to with a CI alone, although outcomes across EAS users vary. The individual differences in performance may be due in part to default mapping procedures, which result in electric frequency-to-place mismatches for the majority of EAS users. This study assessed the influence of electric mismatches on the early speech recognition for EAS users. METHOD: Twenty-one participants were randomized at EAS activation to listen exclusively with a default or place-based map. For both groups, the unaided thresholds determined the acoustic cutoff frequency (i.e., > 65 dB HL). For default maps, the electric filter frequencies were assigned to avoid spectral gaps in frequency information but created varying magnitudes of mismatches. For place-based maps, the electric filter frequencies were assigned to avoid frequency-to-place mismatches. Recognition of consonant-nucleus-consonant words and vowels was assessed at activation and 1, 3, and 6 months postactivation. RESULTS: For participants with default maps, electric mismatch at 1500 Hz ranged from 2 to -12.0 semitones (Mdn = -5 semitones). Poorer performance was observed for those with larger magnitudes of electric mismatch. This effect was observed through 6 months of EAS listening experience. CONCLUSIONS: The present sample of EAS users experienced better initial performance when electric mismatches were small or eliminated. These data suggest the utility of methods that reduce electric mismatches, such as place-based mapping procedures. Investigation is ongoing to determine whether these differences persist with long-term EAS use. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.22096523.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Estimulación Acústica/métodos , Percepción del Habla/fisiología , Implantación Coclear/métodos , Audición
17.
Otol Neurotol ; 43(2): 183-189, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34772886

RESUMEN

OBJECTIVES: 1) To compare speech recognition outcomes between cochlear implant (CI) recipients of 28- and 31.5-mm lateral wall electrode arrays, and 2) to characterize the relationship between angular insertion depth (AID) and speech recognition. STUDY DESIGN: Retrospective review. SETTING: Tertiary academic referral center. PATIENTS: Seventy-five adult CI recipients of fully inserted 28-mm (n = 28) or 31.5-mm (n = 47) lateral wall arrays listening with a CI-alone device. INTERVENTIONS: Cochlear implantation with postoperative computed tomography. MAIN OUTCOME MEASURES: Consonant-nucleus-consonant (CNC) word recognition assessed with the CI-alone at 12 months postactivation. RESULTS: The mean AID of the most apical electrode contact for the 31.5-mm array recipients was significantly deeper than the 28-mm array recipients (628° vs 571°, p < 0.001). Following 12 months of listening experience, mean CNC word scores were significantly better for recipients of 31.5-mm arrays compared with those implanted with 28-mm arrays (59.5% vs 48.3%, p = 0.004; Cohen's d = 0.70; 95% CI [0.22, 1.18]). There was a significant positive correlation between AID and CNC word scores (r = 0.372, p = 0.001), with a plateau in performance observed around 600°. CONCLUSIONS: Cochlear implant recipients implanted with a 31.5-mm array experienced better speech recognition than those with a 28-mm array at 12 months postactivation. Deeper insertion of a lateral wall array appears to confer speech recognition benefit up to ∼600°, with a plateau in performance observed thereafter. These data provide preliminary evidence of the insertion depth necessary to optimize speech recognition outcomes for lateral wall electrode arrays among CI-alone users.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Implantación Coclear/métodos , Implantes Cocleares/efectos adversos , Humanos , Estudios Retrospectivos , Habla , Percepción del Habla/fisiología
18.
Otol Neurotol ; 43(7): e726-e729, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35820072

RESUMEN

OBJECTIVES: Review the effectiveness of an alternative mapping procedure of a precurved electrode array in the internal auditory canal (IAC). DESIGN: A 7-year-old bilateral cochlear implant (CI) recipient of precurved arrays transferred to the study site and demonstrated no speech recognition with the left CI. Imaging revealed bilateral incomplete partition type III malformations. For the left CI, four contacts were observed in the basal cochlear turn and 18 contacts were coiled in the IAC. The family decided against revision surgery. Pitch ranking was completed to map the contacts in the IAC that were perceptually discrete and tonotopically organized. RESULTS: For the left CI, PB-K word recognition improved from no recognition to 32% after 1 month and to 52% after 3 months. In the bilateral CI condition, performance improved from 56 to 72% after 1 month and 80% after 3 months. CONCLUSION: A precurved array in the IAC creates difficult management decisions. Direct stimulation of the auditory nerve resulted in better monaural and bilateral speech recognition, likely due to better spectral representation of the speech signal. Individualizing the map using imaging and behavioral findings may improve performance for malpositioned arrays when revision surgery is not pursued.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Oído Interno , Percepción del Habla , Niño , Implantación Coclear/métodos , Nervio Coclear/fisiología , Oído Interno/diagnóstico por imagen , Oído Interno/cirugía , Humanos , Habla
19.
Am J Audiol ; 31(2): 427-432, 2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35271345

RESUMEN

PURPOSE: The purpose of this study was to assess the influence of talker protective face coverings on sentence recognition in noise for cochlear implant users. METHOD: The AzBio sentences were recorded in three conditions: (a) without any face covering (uncovered), (b) with an N95 mask, or (c) with an N95 mask plus face shield. Target sentences were presented at 60 dB SPL, and the 10-talker masker was presented at 50 dB SPL (10 dB signal-to-noise ratio. Speech recognition for these auditory stimuli was compared across conditions for 21 adult subjects with at least 6 months of cochlear implant (CI) use. RESULTS: Significant deterioration in sentence recognition was observed for the N95 plus face shield (Mdn = 27% [IQR: 14%-35%]) compared with the N95 (Mdn = 72% [IQR: 55%-78%]) condition and for the N95 compared to uncovered (Mdn = 86% [IQR: 68%-91%]) condition. CONCLUSIONS: Talker protective face coverings have a significant influence on speech recognition in noise for CI users. More research is needed to understand the influence of visual cues with protective face coverings that include a plastic component allowing visualization of the talker's face. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.19326395.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Ruido , Relación Señal-Ruido
20.
Laryngoscope ; 131(1): 25-27, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32040200

RESUMEN

OBJECTIVES/HYPOTHESIS: To measure and report noise exposure at urban music venues and assess the risk of noise-induced hearing loss by comparing these measures to the National Institute of Occupations Safety and Health (NIOSH) guidelines. STUDY DESIGN: Observational study. METHODS: A commercially available smartphone and external calibrated microphone were used to measure sound levels at urban music venues. The maximum sound level, equivalent continuous sound level, and statistical noise levels (L10, L50, L75, L90) were recorded. RESULTS: The average equivalent continuous sound level was 112.0 (±4.9) dBA, and the average maximum sound level was 127.0 (±3.2) dBA. The L90 average (sound levels at or above this loudness for 90% of measured exposure time) was 101.1 (±5.5) dBA, and the L10 average was 115.2 (±5.0) dBA. Based off of NIOSH guidelines, noise exposure duration at the L10 average should not exceed 28 seconds, and those at the L90 average should not exceed 12 minutes. CONCLUSIONS: Smartphone applications using external calibrated microphones can provide useful sound measurements. Data show that randomly sampled music venues may have noise levels that place patrons without hearing protection at risk for noise-induced hearing loss with prolonged exposure. LEVEL OF EVIDENCE: NA Laryngoscope, 131:25-27, 2021.


Asunto(s)
Pérdida Auditiva Provocada por Ruido/etiología , Actividades Recreativas , Música , Humanos , Factores de Riesgo , Teléfono Inteligente , Tennessee , Población Urbana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA