Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(29): 2620-2630, 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-38809189

RESUMEN

BACKGROUND AND AIMS: This study aimed to evaluate clinical outcomes in patients developing post-operative atrial fibrillation (POAF) after coronary artery bypass grafting (CABG) and characterize variations in oral anticoagulation (OAC) use, benefits, and complications. METHODS: A systematic search identified studies on new-onset POAF after CABG and OAC initiation. Outcomes included risks of thromboembolic events, bleeding, and mortality. Furthermore, a meta-analysis was conducted on these outcomes, stratified by the use or non-use of OAC. RESULTS: The identified studies were all non-randomized. Among 1 698 307 CABG patients, POAF incidence ranged from 7.9% to 37.6%. Of all POAF patients, 15.5% received OAC. Within 30 days, thromboembolic events occurred at rates of 1.0% (POAF: 0.3%; non-POAF: 0.8%) with 2.0% mortality (POAF: 1.0%; non-POAF: 0.5%). Bleeding rates were 1.1% for POAF patients and 2.7% for non-POAF patients. Over a median of 4.6 years, POAF patients had 1.73 thromboembolic events, 3.39 mortality, and 2.00 bleeding events per 100 person-years; non-POAF patients had 1.14, 2.19, and 1.60, respectively. No significant differences in thromboembolic risks [effect size -0.11 (-0.36 to 0.13)] and mortality [effect size -0.07 (-0.21 to 0.07)] were observed between OAC users and non-users. However, OAC use was associated with higher bleeding risk [effect size 0.32 (0.06-0.58)]. CONCLUSIONS: In multiple timeframes following CABG, the incidence of complications in patients who develop POAF is low. The use of OAC in patients with POAF after CABG is associated with increased bleeding risk.


Asunto(s)
Anticoagulantes , Fibrilación Atrial , Puente de Arteria Coronaria , Complicaciones Posoperatorias , Tromboembolia , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Puente de Arteria Coronaria/efectos adversos , Anticoagulantes/uso terapéutico , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Complicaciones Posoperatorias/epidemiología , Tromboembolia/prevención & control , Tromboembolia/epidemiología , Tromboembolia/etiología , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Femenino , Administración Oral , Masculino , Incidencia
2.
Health Qual Life Outcomes ; 21(1): 33, 2023 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-37016364

RESUMEN

BACKGROUND: In this study, the prognostic value of AF-related quality of life (AFEQT) at baseline on Major Adverse Cardiovascular Events (MACE) and improvement of perceived symptoms (EHRA) was assessed. Furthermore, the relationship between QoL and AF-related hospitalizations was assessed. METHODS: A cohort of AF-patients diagnosed between November 2014 and October 2019 in four hospitals embedded within the Netherlands Heart Network were prospectively followed for 12 months. MACE was defined as stroke, myocardial infarction, heart failure and/or mortality. Subsequently, MACE, EHRA score improvement and AF-related hospitalizations between baseline and 12 months of follow-up were recorded. RESULTS: In total, 970 AF-patients were available for analysis. In analyses with patients with complete information on the confounder subset 36/687 (5.2%) AF-patients developed MACE, 190/432 (44.0%) improved in EHRA score and 189/510(37.1%) were hospitalized during 12 months of follow-up. Patients with a low AFEQT score at baseline more often developed MACE (OR(95%CI): 2.42(1.16-5.06)), more often improved in EHRA score (OR(95%CI): 4.55(2.45-8.44) and were more often hospitalized (OR(95%CI): 4.04(2.22-7.01)) during 12 months post diagnosis, compared to patients with a high AFEQT score at baseline. CONCLUSIONS: AF-patients with a lower quality of life at diagnosis more often develop MACE, more often improve on their symptoms and also were more often hospitalized, compared to AF-patients with a higher quality of life. This study highlights that the integration of patient-reported outcomes, such as quality of life, has the potential to be used as a prognostic indicator of the expected disease course for AF.


Asunto(s)
Fibrilación Atrial , Humanos , Calidad de Vida , Pronóstico , Pacientes , Progresión de la Enfermedad
3.
N Engl J Med ; 380(16): 1499-1508, 2019 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-30883054

RESUMEN

BACKGROUND: Patients with recent-onset atrial fibrillation commonly undergo immediate restoration of sinus rhythm by pharmacologic or electrical cardioversion. However, whether immediate restoration of sinus rhythm is necessary is not known, since atrial fibrillation often terminates spontaneously. METHODS: In a multicenter, randomized, open-label, noninferiority trial, we randomly assigned patients with hemodynamically stable, recent-onset (<36 hours), symptomatic atrial fibrillation in the emergency department to be treated with a wait-and-see approach (delayed-cardioversion group) or early cardioversion. The wait-and-see approach involved initial treatment with rate-control medication only and delayed cardioversion if the atrial fibrillation did not resolve within 48 hours. The primary end point was the presence of sinus rhythm at 4 weeks. Noninferiority would be shown if the lower limit of the 95% confidence interval for the between-group difference in the primary end point in percentage points was more than -10. RESULTS: The presence of sinus rhythm at 4 weeks occurred in 193 of 212 patients (91%) in the delayed-cardioversion group and in 202 of 215 (94%) in the early-cardioversion group (between-group difference, -2.9 percentage points; 95% confidence interval [CI], -8.2 to 2.2; P = 0.005 for noninferiority). In the delayed-cardioversion group, conversion to sinus rhythm within 48 hours occurred spontaneously in 150 of 218 patients (69%) and after delayed cardioversion in 61 patients (28%). In the early-cardioversion group, conversion to sinus rhythm occurred spontaneously before the initiation of cardioversion in 36 of 219 patients (16%) and after cardioversion in 171 patients (78%). Among the patients who completed remote monitoring during 4 weeks of follow-up, a recurrence of atrial fibrillation occurred in 49 of 164 patients (30%) in the delayed-cardioversion group and in 50 of 171 (29%) in the early-cardioversion group. Within 4 weeks after randomization, cardiovascular complications occurred in 10 patients and 8 patients, respectively. CONCLUSIONS: In patients presenting to the emergency department with recent-onset, symptomatic atrial fibrillation, a wait-and-see approach was noninferior to early cardioversion in achieving a return to sinus rhythm at 4 weeks. (Funded by the Netherlands Organization for Health Research and Development and others; RACE 7 ACWAS ClinicalTrials.gov number, NCT02248753.).


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Cardioversión Eléctrica , Tiempo de Tratamiento , Antagonistas Adrenérgicos beta/uso terapéutico , Anciano , Antiarrítmicos/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Bloqueadores de los Canales de Calcio/uso terapéutico , Digoxina/uso terapéutico , Cardioversión Eléctrica/efectos adversos , Servicio de Urgencia en Hospital , Femenino , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Calidad de Vida , Recurrencia , Resultado del Tratamiento
4.
BMC Cardiovasc Disord ; 22(1): 104, 2022 03 14.
Artículo en Inglés | MEDLINE | ID: mdl-35287575

RESUMEN

BACKGROUND: The left atrium (LA) is a key player in the pathophysiology of systolic and diastolic heart failure (HF). Speckle tracking derived LA reservoir strain (LASr) can be used as a prognostic surrogate for elevated left ventricular filling pressure similar to NT-proBNP. The aim of the study is to investigate the correlation between LASr and NT-proBNP and its prognostic value with regards to the composite endpoint of HF hospitalization and all-cause mortality within 1 year. METHODS: Outpatients, sent to the echocardiography core lab because of HF, were enrolled into this study. Patients underwent a transthoracic echocardiographic examination, commercially available software was used to measure LASr. Blood samples were collected directly after the echocardiographic examination to determine NT-proBNP. RESULTS: We included 174 HF patients, 43% with reduced, 36% with mildly reduced, and 21% with preserved ejection fraction. The study population showed a strong inverse correlation between LASr and log-transformed NT-proBNP (r = - 0.75, p < 0.01). Compared to NT-proBNP, LASr predicts the endpoint with a comparable specificity (83% vs. 84%), however with a lower sensitivity (70% vs. 61%). CONCLUSION: LASr is inversely correlated with NT-proBNP and a good echocardiographic predictor for the composite endpoint of hospitalization and all-cause mortality in patients with HF. TRIAL REGISTRATION: https://www.trialregister.nl/trial/7268.


Asunto(s)
Insuficiencia Cardíaca , Biomarcadores , Estudios de Cohortes , Atrios Cardíacos/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/epidemiología , Humanos , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Pronóstico , Volumen Sistólico/fisiología , Función Ventricular Izquierda
5.
J Cardiovasc Electrophysiol ; 32(4): 1140-1146, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33629788

RESUMEN

Electroanatomic mapping systems have become an essential tool to guide the identification and ablation of arrhythmic substrate. Recently, a novel guiding system for electrophysiology procedures was introduced that uses dielectric sensing to perform high resolution anatomical imaging. Dielectric imaging systems use electrical fields to differentiate anatomic structures based on their conductivity and permittivity. This technique enables non-fluoroscopic, noncontact mapping of anatomic structures, assessment of pulmonary vein occlusion state during cryoballoon ablation, and has the potential to assess for additional tissue characterization including tissue thickness and tissue type. This article elaborates on the functioning and potential of dielectric imaging systems and provides two cases to illustrate the clinical impact for electrophysiology procedures.


Asunto(s)
Ablación por Catéter , Electrofisiología Cardíaca , Humanos , Tecnología
6.
BMC Health Serv Res ; 20(1): 494, 2020 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-32493361

RESUMEN

BACKGROUND: Value-based healthcare (VBHC) is a promising strategy to increase patient value. For a successful implementation of VBHC, intensive collaborations between organizations and integrated care delivery systems are key conditions. Our aim was to evaluate the effects of a pilot study regarding enhancing regional integration between a cardiac centre and a referring hospital on patient-relevant clinical outcomes and patient satisfaction. METHODS: The study population consisted of a sample of patients treated for coronary artery disease by use of a coronary artery bypass graft (CABG) or a percutaneous coronary intervention between 2011 and 2016. Since 2013, the two hospitals have implemented different interventions to improve clinical outcomes and the degree of patient satisfaction, e.g. improvement of communication, increased consultant capacity, introduction of outpatient clinic for complex patients, and improved guideline adherence. To identify intervention effects, logistic regression analyses were conducted. Patients' initial conditions, like demographics and health status, were included in the model as predictors. Clinical data extracted from the electronic health records and the hospitals' cardiac databases as well as survey-based data were used. RESULTS: Our findings indicate a non-significant increase of event-free survival of patients treated for coronary artery disease between 2014 and 2016 compared to patients treated between 2011 and 2013 (97.4% vs. 96.7% respectively). This non-significant improvement over time has led to significant better outcomes for patients referred from the study referring hospital compared to patients referred from other hospitals. The level of patient satisfaction (response rate 32.2%; 216 out of 669) was improved and reached statistically significant higher scores regarding patient information and education (p = .013), quality of care (p = .007), hospital admission and stay (p = .032), personal contact with the physician (p = .024), and total impression (p = .007). CONCLUSIONS: This study shows a promising effect of regional integration. An intensified collaboration in the care chain, organized in a structured manner between a cardiac centre and a referring hospital and aiming at high quality, resulted in successful improvement of clinical outcomes and degree of patient satisfaction. The applied method may be used as a starting point of regional integration with other referring hospitals. We encourage others to organize the whole care chain to continuously improve patient-relevant outcomes and patient satisfaction. TRIAL REGISTRATION: ISRCTN11311830. Registered 01 October 2018 (retrospectively registered).


Asunto(s)
Instituciones Cardiológicas/organización & administración , Enfermedad de la Arteria Coronaria/cirugía , Satisfacción del Paciente/estadística & datos numéricos , Derivación y Consulta/organización & administración , Anciano , Puente de Arteria Coronaria , Femenino , Encuestas de Atención de la Salud , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Proyectos Piloto , Resultado del Tratamiento
7.
Europace ; 20(FI_3): f321-f328, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29036652

RESUMEN

Aims: Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Methods and results: Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with <1% loss in true episodes or duration. The algorithm correctly identified 98.9% of total AF duration and 99.8% of total sinus or non-AF rhythm duration. The algorithm detected 97.2% (99.7% per-patient average) of all AF episodes ≥2-min, and 84.9% (95.3% per-patient average) of detected episodes involved AF. Conclusion: An enhancement that adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity.


Asunto(s)
Algoritmos , Arritmia Sinusal/diagnóstico , Fibrilación Atrial/diagnóstico , Electrocardiografía Ambulatoria/métodos , Frecuencia Cardíaca , Procesamiento de Señales Asistido por Computador , Telemedicina/métodos , Telemetría/métodos , Anciano , Arritmia Sinusal/fisiopatología , Fibrilación Atrial/fisiopatología , Equipo para Diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Telemedicina/instrumentación , Telemetría/instrumentación , Factores de Tiempo
8.
Pacing Clin Electrophysiol ; 40(3): 294-300, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28054365

RESUMEN

BACKGROUND: Central sleep apnea syndrome, correlated with the occurrence of heart failure, is characterized by periods of insufficient ventilation during sleep. This acute study in 15 patients aims to map the venous system and determine if diaphragmatic movement can be achieved by phrenic nerve stimulation at various locations within the venous system. METHODS: Subjects underwent a scheduled catheter ablation procedure. During the procedural waiting time, one multielectrode electrophysiology catheter was subsequently placed at the superior and inferior vena cava and the junctions of the left jugular and left brachiocephalic vein and right jugular and right brachiocephalic vein, for phrenic nerve stimulation (1-2 seconds ON/2-3 seconds OFF, 40 Hz, pulse width 210 µs). Diaphragmatic movement was assessed manually and by a breathing mask. During a follow-up assessment between 2 and 4 weeks postprocedure, occurrence of adverse events was assessed. RESULTS: In all patients diaphragmatic movement was induced at one or more locations using a median threshold of at least 2 V and maximally 7.5 V (i.e., e 3.3 mA, 14.2 mA). The lowest median current to obtain diaphragmatic stimulation without discomfort was found for the right brachiocephalic vein (4.7 mA). In 12/15 patients diaphragmatic movement could be induced without any discomfort, but in three patients hiccups occurred. CONCLUSION: Diaphragmatic stimulation from the brachiocephalic and caval veins is feasible. Potential side effects should be eliminated by adapting the stimulation pattern. This information could be used to design a catheter, combining cardiac pacing with enhancing diaphragm movement during a sleep apnea episode.


Asunto(s)
Cateterismo Periférico/métodos , Diafragma/fisiopatología , Terapia por Estimulación Eléctrica/métodos , Nervio Frénico/fisiopatología , Apnea Central del Sueño/fisiopatología , Apnea Central del Sueño/terapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Apnea Central del Sueño/diagnóstico , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 38(7): 870-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25880250

RESUMEN

BACKGROUND: Prophylactic implantable cardioverter defibrillator (ICD) therapy prevents sudden cardiac death (SCD) among young adults with cardiogenetic conditions, but might reduce quality of life (QoL) due to potential device complications, ongoing medical appointments, and lifestyle restrictions. We investigated QoL in the first year after ICD implantation for the primary prevention of SCD and compared QoL scores with population norms. METHODS: Consecutive patients with cardiogenetic conditions (aged 18-50 years) referred to the Academic Medical Center in Amsterdam to receive ICD therapy for the primary prevention of SCD between 2007 and 2009 were eligible. Patients completed questions about QoL (Short-Form 36 Health Survey; SF-36), depressive symptoms (Center for Epidemiologic Studies Depression scale; CES-D), anxiety (State-Trait Anxiety Inventory; STAI), and the impact of receiving ICD therapy on lifestyle and work, shortly before ICD implantation and after 2 months, 6 months, and 12 months. RESULTS: Thirty-five of 47 eligible patients participated. QoL was significantly reduced shortly before and 2 months after ICD implantation but improved over time and was comparable with population norms at 6 months and 12 months after ICD implantation. Yet, only about half of the patients believed they had a normal life like everyone else, and 28% had lost or changed their job due to their cardiogenetic condition and ICD therapy. CONCLUSIONS: Receiving a diagnosis of a cardiogenetic condition and subsequent ICD implantation was accompanied with a temporarily reduced QoL and a significant negative impact on professional life. Clinicians should inform their patients of the possible QoL consequences when deciding about ICD implantation in primary prevention of SCD in cardiogenetic conditions.


Asunto(s)
Ansiedad/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Depresión/etiología , Cardioversión Eléctrica/psicología , Calidad de Vida/psicología , Adolescente , Adulto , Ansiedad/psicología , Depresión/psicología , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
10.
Muscle Nerve ; 50(6): 909-13, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24619517

RESUMEN

INTRODUCTION: The aim of this study is to describe the frequency, nature, severity, and progression of cardiac abnormalities in a cohort of Dutch sarcoglycanopathy patients. METHODS: In this cross-sectional cohort study, patients were interviewed using a standardized questionnaire and assigned a functional score. Electrocardiography (ECG), echocardiography, and 24-h ECG were performed. RESULTS: Twenty-four patients with sarcoglycanopathy had a median age of 25 years (range, 8-59 years). Beta blockers were used by 13%, and 17% used angiotensin-converting enzyme inhibitors. ECG abnormalities were present in 5 (21%), and 4 (17%) fulfilled the criteria for dilated cardiomyopathy (DCM). There were no significant differences in median age or severity of disease between patients with or without DCM. Eleven patients were examined earlier. Median follow-up time was 10 years. Two of the 11 patients (18%) developed DCM during follow-up. CONCLUSIONS: Seventeen percent of the patients with sarcoglycanopathy were found to have dilated cardiomyopathy. We recommend biannual cardiac monitoring, including ECG and echocardiography.


Asunto(s)
Cardiomiopatía Dilatada/diagnóstico , Cardiomiopatía Dilatada/epidemiología , Sarcoglicanopatías/epidemiología , Adolescente , Adulto , Niño , Estudios de Cohortes , Estudios Transversales , Progresión de la Enfermedad , Ecocardiografía , Electrocardiografía , Femenino , Estudios de Seguimiento , Corazón/fisiopatología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Países Bajos/epidemiología , Estudios Retrospectivos , Sarcoglicanopatías/complicaciones , Índice de Severidad de la Enfermedad , Adulto Joven
11.
Platelets ; 25(1): 71-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-23301869

RESUMEN

Early ischemic ventricular fibrillation (VF) in the setting of an acute myocardial infarction (AMI) due to thrombotic coronary occlusion remains a major health problem. Several animal studies have shown that platelet-dense granule contents released during thrombus formation can induce arrhythmias. We hypothesize that the platelet release reaction is involved in the predisposition to early ischemic VF. A case-control study was performed in patients who survived VF during a first AMI ("cases," n = 26) and in patients with one previous AMI without arrhythmias ("controls," n = 24). All patients were on aspirin 100 mg OD. Baseline platelet activation was assessed with flow cytometry. Response to activation was assessed with aggregometry, flow cytometry and PFA-100 analysis. Differences in platelet contents and content release were assessed by labeling platelet-dense granules with mepacrine and by measuring serotonin and ADP/ATP content. Patient and infarct characteristics and baseline platelet function tests were similar between groups. The mean time from event was 4.9 (±3.2) years among cases and 4.7 (±2.7) years among controls. Dense granule release was similar in cases versus controls. Platelet serotonin content in cases was higher than in controls (611 ± 118 ng/10E(9) platelets vs. 536 ± 141 ng/10(9), p = 0.048). Even years after the event, elevations in the platelet dense granule contents between VF survivors and controls may be detected. These preliminary findings shed new light on the pathophysiological mechanisms underlying ischemic VF, as platelet-dense granules may contain mediators of early ischemic VF risk.


Asunto(s)
Plaquetas/patología , Fibrilación Ventricular/sangre , Anciano , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sobrevivientes , Fibrilación Ventricular/patología
12.
Physiol Meas ; 45(3)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38387047

RESUMEN

Objective.Wearable devices that measure vital signals using photoplethysmography are becoming more commonplace. To reduce battery consumption, computational complexity, memory footprint or transmission bandwidth, companies of commercial wearable technologies are often looking to minimize the sampling frequency of the measured vital signals. One such vital signal of interest is the pulse arrival time (PAT), which is an indicator of blood pressure. To leverage this non-invasive and non-intrusive measurement data for use in clinical decision making, the accuracy of obtained PAT-parameters needs to increase in lower sampling frequency recordings. The aim of this paper is to develop a new strategy to estimate PAT at sampling frequencies up to 25 Hertz.Approach.The method applies template matching to leverage the random nature of sampling time and expected change in the PAT.Main results.The algorithm was tested on a publicly available dataset from 22 healthy volunteers, under sitting, walking and running conditions. The method significantly reduces both the mean and the standard deviation of the error when going to lower sampling frequencies by an average of 16.6% and 20.2%, respectively. Looking only at the sitting position, this reduction is even larger, increasing to an average of 22.2% and 48.8%, respectively.Significance.This new method shows promise in allowing more accurate estimation of PAT even in lower frequency recordings.


Asunto(s)
Determinación de la Presión Sanguínea , Dispositivos Electrónicos Vestibles , Humanos , Determinación de la Presión Sanguínea/métodos , Presión Sanguínea/fisiología , Frecuencia Cardíaca , Fotopletismografía/métodos
13.
JACC Clin Electrophysiol ; 10(8): 1916-1928, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39093277

RESUMEN

Within the broad spectrum of atrial fibrillation (AF) symptomatology, there is a striking subset of patients with predominant or even solitary nocturnal onset of the arrhythmia. This review covers AF with nocturnal onset, with the aim of defining this distinctive subgroup among patients with AF. A periodicity analysis is provided showing a clear increased onset between 10:00 pm and 7:00 am. Multiple interacting mechanisms are discussed, such as circadian modulation of electrophysiological properties, vagal tone, and sleep disorders, as well as the potential interaction and synergism between these factors, to provide a better understanding of this clinical entity. Lastly, potential therapeutic targets for AF with nocturnal onset are addressed such as upstream therapy for underlying comorbidities, type of drug and timing of drug administration and pulmonary vein isolation, ablation of the ganglionated plexus, and autonomic nervous system modulation. Understanding the underlying AF mechanisms in the individual patient with nocturnal onset will contribute to patient-specific therapy.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ritmo Circadiano/fisiología , Trastornos del Sueño-Vigilia/fisiopatología
14.
Front Physiol ; 15: 1330157, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38655031

RESUMEN

Introduction: Assessing a patient's risk of scar-based ventricular tachycardia (VT) after myocardial infarction is a challenging task. It can take months to years after infarction for VT to occur. Also, if selected for ablation therapy, success rates are low. Methods: Computational ventricular models have been presented previously to support VT risk assessment and to provide ablation guidance. In this study, an extension to such virtual-heart models is proposed to phenomenologically incorporate tissue remodeling driven by mechanical load. Strain amplitudes in the heart muscle are obtained from simulations of mechanics and are used to adjust the electrical conductivity. Results: The mechanics-driven adaptation of electrophysiology resulted in a more heterogeneous distribution of propagation velocities than that of standard models, which adapt electrophysiology in the structural substrate from medical images only. Moreover, conduction slowing was not only present in such a structural substrate, but extended in the adjacent functional border zone with impaired mechanics. This enlarged the volumes with high repolarization time gradients (≥10 ms/mm). However, maximum gradient values were not significantly affected. The enlarged volumes were localized along the structural substrate border, which lengthened the line of conduction block. The prolonged reentry pathways together with conduction slowing in functional regions increased VT cycle time, such that VT was easier to induce, and the number of recommended ablation sites increased from 3 to 5 locations. Discussion: Sensitivity testing showed an accurate model of strain-dependency to be critical for low ranges of conductivity. The model extension with mechanics-driven tissue remodeling is a potential approach to capture the evolution of the functional substrate and may offer insight into the progression of VT risk over time.

15.
Circ Arrhythm Electrophysiol ; 17(9): e012913, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39171393

RESUMEN

Out-of-hospital cardiac arrest is a major health problem, and immediate treatment is essential for improving the chances of survival. The development of technological solutions to detect out-of-hospital cardiac arrest and alert emergency responders is gaining momentum; multiple research consortia are currently developing wearable technology for this purpose. For the responsible design and implementation of this technology, it is necessary to attend to the ethical implications. This review identifies relevant ethical aspects of wearable-based out-of-hospital cardiac arrest detection according to four key principles of medical ethics. First, aspects related to beneficence concern the effectiveness of the technology. Second, nonmaleficence requires preventing psychological distress associated with wearing the device and raises questions about the desirability of screening. Third, grounded in autonomy are empowerment, the potential reidentification from continuously collected data, issues of data access, bystander privacy, and informed consent. Finally, justice concerns include the risks of algorithmic bias and unequal technology access. Based on this overview and relevant legislation, we formulate design recommendations. We suggest that key elements are device accuracy and reliability, dynamic consent, purpose limitation, and personalization. Further empirical research is needed into the perspectives of stakeholders, including people at risk of out-of-hospital cardiac arrest and their next-of-kin, to achieve a successful and ethically balanced integration of this technology in society.


Asunto(s)
Paro Cardíaco Extrahospitalario , Dispositivos Electrónicos Vestibles , Humanos , Paro Cardíaco Extrahospitalario/terapia , Paro Cardíaco Extrahospitalario/diagnóstico , Dispositivos Electrónicos Vestibles/ética , Consentimiento Informado/ética , Confidencialidad/ética , Valor Predictivo de las Pruebas , Beneficencia , Reproducibilidad de los Resultados , Diseño de Equipo
16.
Resusc Plus ; 17: 100576, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38370313

RESUMEN

Aim: Out-of-hospital cardiac arrest is a major health problem, and the overall survival rate is low (4.6%-16.4%). The initiation of the current chain of survival depends on the presence of a witness of the cardiac arrest, which is not present in 29.7%-63.4% of the cases. Furthermore, a delay in starting this chain is common in witnessed out-of-hospital cardiac arrest. This project aims to reduce morbidity and mortality due to out-of-hospital cardiac arrest by developing a smartwatch-based solution to expedite the chain of survival in the case of (un)witnessed out-of-hospital cardiac arrest. Methods: Within the 'Beating Cardiac Arrest' project, we aim to develop a demonstrator product that detects out-of-hospital cardiac arrest using photoplethysmography and accelerometer analysis, and autonomously alerts emergency medical services. A target group study will be performed to determine who benefits the most from this product. Furthermore, several clinical studies will be conducted to capture or simulate data on out-of-hospital cardiac arrest cases, as to develop detection algorithms and validate their diagnostic performance. For this, the product will be worn by patients at high risk for out-of-hospital cardiac arrest, by volunteers who will temporarily interrupt blood flow in their arm by inflating a blood pressure cuff, and by patients who undergo cardiac electrophysiologic and implantable cardioverter defibrillator testing procedures. Moreover, studies on psychosocial and ethical acceptability will be conducted, consisting of surveys, focus groups, and interviews. These studies will focus on end-user preferences and needs, to ensure that important individual and societal values are respected in the design process.

17.
Heart ; 110(6): 408-415, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38040452

RESUMEN

OBJECTIVE: Prehospital risk stratification and triage are currently not performed in patients suspected of non-ST-segment elevation acute coronary syndrome (NSTE-ACS). This may lead to prolonged time to revascularisation, increased duration of hospital admission and higher healthcare costs. The preHEART score (prehospital history, ECG, age, risk factors and point-of-care troponin score) can be used by emergency medical services (EMS) personnel for prehospital risk stratification and triage decisions in patients with NSTE-ACS. The aim of the current study was to evaluate the effect of prehospital risk stratification and direct transfer to a percutaneous coronary intervention (PCI) centre, based on the preHEART score, on time to final invasive diagnostics or culprit revascularisation. METHODS: Prospective, multicentre, two-cohort study in patients with suspected NSTE-ACS. The first cohort is observational (standard care), while the second (interventional) cohort includes patients who are stratified for direct transfer to either a PCI or a non-PCI centre based on their preHEART score. Risk stratification and triage are performed by EMS personnel. The primary endpoint of the study is time from first medical contact until final invasive diagnostics or revascularisation. Secondary endpoints are time from first medical contact until intracoronary angiography (ICA), duration of hospital admission, number of invasive diagnostics, number of inter-hospital transfers and major adverse cardiac events at 7 and 30 days. RESULTS: A total of 1069 patients were included. In the interventional cohort (n=577), time between final invasive diagnostics or revascularisation (42 (17-101) hours vs 20 (5-44) hours, p<0.001) and length of hospital admission (3 (2-5) days vs 2 (1-4) days, p=0.007) were shorter than in the observational cohort (n=492). In patients with NSTE-ACS in need for ICA or revascularisation, healthcare costs were reduced in the interventional cohort (€5599 (2978-9625) vs €4899 (2278-5947), p=0.02). CONCLUSION: Prehospital risk stratification and direct transfer to a PCI centre, based on the preHEART score, reduces time from first medical contact to final invasive diagnostics and revascularisation, reduces duration of hospital admission and decreases healthcare costs in patients with NSTE-ACS in need for ICA or revascularisation. TRIAL REGISTRATION: NCT05243485.


Asunto(s)
Síndrome Coronario Agudo , Servicios Médicos de Urgencia , Intervención Coronaria Percutánea , Humanos , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Estudios de Cohortes , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Medición de Riesgo
18.
Front Physiol ; 14: 1157338, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37293260

RESUMEN

Atrial fibrillation (AF) often requires invasive treatment by ablation to decrease symptom burden. The pulmonary veins (PV) are thought to trigger paroxysms of AF, and ablative PV isolation (PVI) is a cornerstone in AF treatment. However, incomplete PVI, where electrical conduction between the PV and left atrium (LA) is maintained, is curative of AF in a subset of patients. This implies that an antiarrhythmic effect other than electrical isolation between the PV and LA plays a role in AF prevention in these patients. We reason that the PV myocardium constitutes an arrhythmogenic substrate conducive to reentry in the patients with curative incomplete PVI. This PV substrate is amenable to ablation, even when conduction between the LA and PV persists. We propose that PV ablation strategies are differentiated to fit the arrhythmogenic mechanisms in the individual patient. PV substrate modification in patients with PV reentry may constitute a new therapeutic approach that is potentially simpler and more effective, in this subgroup of patients.

19.
Heart Rhythm ; 20(2): 291-298, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36265692

RESUMEN

Atrial fibrillation (AF) is a common cardiac arrhythmia that is associated with increased mortality. Heart failure, hypertension, valvular disease, and obstructive sleep apnea are risk factors for incident AF. A common characteristic of these diseases is that they increase atrial wall stretch. Multiple experimental studies confirm a proarrhythmic effect of atrial stretch. Conversely, a reduction in stretch is antiarrhythmic. A therapeutic target for AF, therefore, lies in local reduction of atrial stretch. This review focuses on atrial stretch and its clinical associations in patients with AF and its downstream effects on electrophysiology. We discuss the possible application of targeted atrial stretch reduction in AF prevention. We conclude that a reduction in local atrial stretch should be considered an essential element in rhythm control.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/tratamiento farmacológico , Venas Pulmonares/cirugía , Atrios Cardíacos , Antiarrítmicos/uso terapéutico , Factores de Riesgo , Ablación por Catéter/efectos adversos , Resultado del Tratamiento
20.
Obes Surg ; 33(11): 3636-3648, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37801237

RESUMEN

Epicardial adipose tissue (EAT) is a visceral fat depot located between the myocardium and visceral epicardium. Emerging evidence suggests that excessive EAT is linked to increased risk of cardiovascular conditions and other metabolic diseases. A literature search was conducted from the earliest studies to the 26th of November 2022 on PubMed, Embase, and the Cochrane. All the studies evaluating changes in EAT, pericardial adipose tissue (PAT), or total cardiac fat loss before and after BS were included. From 623 articles, 35 were eventually included in the systematic review. Twenty-one studies showed a significant reduction of EAT after BS, and only one study showed a non-significant reduction (p = 0.2).


Asunto(s)
Cirugía Bariátrica , Enfermedades Cardiovasculares , Obesidad Mórbida , Humanos , Obesidad Mórbida/cirugía , Tejido Adiposo , Pericardio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA