1.
Magn Reson Med ; 85(1): 551-559, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32820540

RESUMEN

PURPOSE: This work describes the construction and evaluation of a bilateral 32-channel receive array for breast imaging at 7T. METHODS: The receive array consisted of 32 receive coils, placed on two 3D-printed hemispherical formers. Each side of the receive array consisted of 16 receive loops, each loop having a corresponding detachable board with match/tune capacitors, active detuning circuitry, and a balun. Coil performance was evaluated on homogeneous canola oil phantoms using a Philips Achieva 7T system. Array coil performance was compared with a bilateral forced current excitation volume coil in transmit/receive mode and with a previously reported 16-channel unilateral coil with a similar design. RESULTS: The 32-channel array had an increase in average SNR throughout both phantoms by a factor of five as compared with the volume coil, with SNR increases up to 10 times along the periphery and three times in the center. Noise measurements showed low interelement noise correlation (average: 5.4%; maximum: 16.8%). Geometry factor maps were acquired for various acceleration factors and showed mean geometry factors <1.2, for combined acceleration factors of up to six. CONCLUSIONS: The improvements achieved demonstrate the clear potential for use in dynamic contrast-enhanced or diffusion-weighted MR studies, while maintaining diagnostically relevant spatial and temporal resolutions.


Asunto(s)
Mama , Imagen por Resonancia Magnética , Mama/diagnóstico por imagen , Diseño de Equipo , Fantasmas de Imagen , Relación Señal-Ruido , Análisis Espectral
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 6258-6261, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28269681

RESUMEN

This work describes the construction and testing of a three-element, double-tuned receive array and transmit coils for 31P-1H spectroscopy and imaging. The receive coils were geometrically-decoupled, single-loop surface coils and the transmit coils were concentric saddle coils. The coils were used to examine a physiologically-modeled CNC-milled phantom. The receive coil array was able to improve SNR while also providing gross localization of the 1H and 31P signals.


Asunto(s)
Espectroscopía de Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/métodos , Humanos , Fantasmas de Imagen