Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Magn Reson Med ; 67(2): 322-5, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22083758

RESUMEN

The (3)He MR diffusion signal is sensitive to lung microstructure, but it is also affected by the presence of background field inhomogeneities induced by the magnetic susceptibility difference at the air-tissue interface. These susceptibility-induced gradients, which are dependent on field strength, have been assumed negligible in theoretical models used to extract airway morphometric information from (3)He MR diffusion data at field strengths up to 4.7 T. In this work, the effect of susceptibility gradients on (3)He apparent diffusion coefficient is demonstrated with experiments in healthy volunteers at two B(0) field strengths: 1.5 and 3 T. Apparent diffusion coefficient values obtained at 3 T were systematically larger than at 1.5 T, demonstrating that susceptibility effects are statistically significant even at clinical field strengths (B(0) ≤ 3 T) and introduce biases in the estimates of airway dimensions (e.g., mean linear intercept up to 17% larger at 3 T than 1.5 T). Susceptibility effects should be taken into account in the development of theoretical models of lung (3)He MR diffusion and considered when interpreting (3)He apparent diffusion coefficients obtained at different B(0).


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/fisiología , Administración por Inhalación , Adulto , Algoritmos , Artefactos , Simulación por Computador , Gases , Helio , Humanos , Isótopos , Mediciones del Volumen Pulmonar , Modelos Teóricos , Valores de Referencia , Relación Señal-Ruido
2.
NMR Biomed ; 25(1): 44-51, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22241670

RESUMEN

In imaging of human lungs with hyperpolarised noble gases, measurements of apparent diffusion coefficient (ADC) and relaxation time provide valuable information for the assessment of lung microstructure. In this work, a sequence was developed for interleaved acquisition of ventilation images, ADC, T(2)* and flip angle maps in a single scan from the human lungs with a single dose of inhaled (3)He at 3 T. Spatially registered ventilation images with parametric maps were obtained. The total acquisition time was reduced by random undersampling of the k-space and reconstruction using compressed sensing (CS). The gain in speed was used for an increase in spatial resolution. Mean ADC values from the fully sampled and undersampled CS data exhibit no statistically significant difference in a given subject. The mean T(2)* values, however, were found to differ significantly, which is attributed to the combined effect of low signal-to-noise ratio (SNR) of the fully sampled data and the smoothing effect inherent in CS reconstruction.


Asunto(s)
Helio , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Respiración , Adulto , Anisotropía , Difusión , Femenino , Salud , Humanos , Masculino
3.
J Magn Reson ; 204(2): 228-38, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20347604

RESUMEN

Models of lung acinar geometry have been proposed to analytically describe the diffusion of (3)He in the lung (as measured with pulsed gradient spin echo (PGSE) methods) as a possible means of characterizing lung microstructure from measurement of the (3)He ADC. In this work, major limitations in these analytical models are highlighted in simple diffusion weighted experiments with (3)He in cylindrical models of known geometry. The findings are substantiated with numerical simulations based on the same geometry using finite difference representation of the Bloch-Torrey equation. The validity of the existing "cylinder model" is discussed in terms of the physical diffusion regimes experienced and the basic reliance of the cylinder model and other ADC-based approaches on a Gaussian diffusion behaviour is highlighted. The results presented here demonstrate that physical assumptions of the cylinder model are not valid for large diffusion gradient strengths (above approximately 15 mT/m), which are commonly used for (3)He ADC measurements in human lungs.


Asunto(s)
Helio/farmacocinética , Interpretación de Imagen Asistida por Computador/métodos , Pulmón/anatomía & histología , Pulmón/metabolismo , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Modelos Biológicos , Simulación por Computador , Helio/química , Humanos , Aumento de la Imagen/métodos , Isótopos/química , Isótopos/farmacocinética , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA