Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Neurol Neurosurg Psychiatry ; 95(8): 748-752, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38199813

RESUMEN

BACKGROUND: Consistent patterns of reduced cortical thickness have been identified in early Alzheimer's disease (AD). However, the pathological factors that influence rates of cortical thinning within these AD signature regions remain unclear. METHODS: Participants were from the Insight 46 substudy of the MRC National Survey of Health and Development (NSHD; 1946 British birth cohort), a prospective longitudinal cohort study. Linear regression was used to examine associations of baseline cerebral ß-amyloid (Aß) deposition, measured using florbetapir positron emission tomography, and baseline white matter hyperintensity volume (WMHV) on MRI, a marker of cerebral small vessel disease, with subsequent longitudinal changes in AD signature cortical thickness quantified from baseline and repeat MRI (mean [SD] interval 2.4 [0.2] years). RESULTS: In a population-based sample of 337 cognitively normal older white adults (mean [SD] age at baseline 70.5 [0.6] years; 48.1% female), higher global WMHV at baseline related to faster subsequent rates of cortical thinning in both AD signature regions (~0.15%/year faster per 10 mL additional WMHV), whereas baseline Aß status did not. Among Aß positive participants (n=56), there was some evidence that greater global Aß standardised uptake value ratio at baseline related to faster cortical thinning in the AD signature Mayo region, but this did not reach statistical significance (p=0.08). CONCLUSIONS: Cortical thinning within AD signature regions may develop via cerebrovascular pathways. Perhaps reflecting the age of the cohort and relatively low prevalence of Aß-positivity, robust Aß-related differences were not detected. Longitudinal follow-up incorporating additional biomarkers will allow assessment of how these relationships evolve closer to expected dementia onset.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Adelgazamiento de la Corteza Cerebral , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Sustancia Blanca , Humanos , Femenino , Masculino , Anciano , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Enfermedad de Alzheimer/metabolismo , Péptidos beta-Amiloides/metabolismo , Estudios Longitudinales , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología , Adelgazamiento de la Corteza Cerebral/diagnóstico por imagen , Adelgazamiento de la Corteza Cerebral/patología , Estudios Prospectivos , Glicoles de Etileno , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/patología , Corteza Cerebral/metabolismo , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Enfermedades de los Pequeños Vasos Cerebrales/patología , Compuestos de Anilina
2.
BMC Neurol ; 24(1): 40, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38263061

RESUMEN

BACKGROUND: Although age is the biggest known risk factor for dementia, there remains uncertainty about other factors over the life course that contribute to a person's risk for cognitive decline later in life. Furthermore, the pathological processes leading to dementia are not fully understood. The main goals of Insight 46-a multi-phase longitudinal observational study-are to collect detailed cognitive, neurological, physical, cardiovascular, and sensory data; to combine those data with genetic and life-course information collected from the MRC National Survey of Health and Development (NSHD; 1946 British birth cohort); and thereby contribute to a better understanding of healthy ageing and dementia. METHODS/DESIGN: Phase 1 of Insight 46 (2015-2018) involved the recruitment of 502 members of the NSHD (median age = 70.7 years; 49% female) and has been described in detail by Lane and Parker et al. 2017. The present paper describes phase 2 (2018-2021) and phase 3 (2021-ongoing). Of the 502 phase 1 study members who were invited to a phase 2 research visit, 413 were willing to return for a clinic visit in London and 29 participated in a remote research assessment due to COVID-19 restrictions. Phase 3 aims to recruit 250 study members who previously participated in both phases 1 and 2 of Insight 46 (providing a third data time point) and 500 additional members of the NSHD who have not previously participated in Insight 46. DISCUSSION: The NSHD is the oldest and longest continuously running British birth cohort. Members of the NSHD are now at a critical point in their lives for us to investigate successful ageing and key age-related brain morbidities. Data collected from Insight 46 have the potential to greatly contribute to and impact the field of healthy ageing and dementia by combining unique life course data with longitudinal multiparametric clinical, imaging, and biomarker measurements. Further protocol enhancements are planned, including in-home sleep measurements and the engagement of participants through remote online cognitive testing. Data collected are and will continue to be made available to the scientific community.


Asunto(s)
Demencia , Anciano , Femenino , Humanos , Masculino , Envejecimiento , Atención Ambulatoria , Encéfalo , Estudios Observacionales como Asunto
3.
Eur J Nucl Med Mol Imaging ; 50(4): 980-995, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36469107

RESUMEN

PURPOSE: Quantitative SPECT-CT is a modality of growing importance with initial developments in post radionuclide therapy dosimetry, and more recent expansion into bone, cardiac and brain imaging together with the concept of theranostics more generally. The aim of this document is to provide guidelines for nuclear medicine departments setting up and developing their quantitative SPECT-CT service with guidance on protocols, harmonisation and clinical use cases. METHODS: These practice guidelines were written by members of the European Association of Nuclear Medicine Physics, Dosimetry, Oncology and Bone committees representing the current major stakeholders in Quantitative SPECT-CT. The guidelines have also been reviewed and approved by all EANM committees and have been endorsed by the European Association of Nuclear Medicine. CONCLUSION: The present practice guidelines will help practitioners, scientists and researchers perform high-quality quantitative SPECT-CT and will provide a framework for the continuing development of quantitative SPECT-CT as an established modality.


Asunto(s)
Medicina Nuclear , Humanos , Cintigrafía , Medicina Nuclear/métodos , Diagnóstico por Imagen , Radioisótopos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único
4.
Brain ; 144(2): 434-449, 2021 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-33479777

RESUMEN

Alzheimer's disease has a preclinical stage when cerebral amyloid-ß deposition occurs before symptoms emerge, and when amyloid-ß-targeted therapies may have maximum benefits. Existing amyloid-ß status measurement techniques, including amyloid PET and CSF testing, are difficult to deploy at scale, so blood biomarkers are increasingly considered for screening. We compared three different blood-based techniques-liquid chromatography-mass spectrometry measures of plasma amyloid-ß, and single molecule array (Simoa) measures of plasma amyloid-ß and phospho-tau181-to detect cortical 18F-florbetapir amyloid PET positivity (defined as a standardized uptake value ratio of >0.61 between a predefined cortical region of interest and eroded subcortical white matter) in dementia-free members of Insight 46, a substudy of the population-based British 1946 birth cohort. We used logistic regression models with blood biomarkers as predictors of amyloid PET status, with or without age, sex and APOE ε4 carrier status as covariates. We generated receiver operating characteristics curves and quantified areas under the curves to compare the concordance of the different blood tests with amyloid PET. We determined blood test cut-off points using Youden's index, then estimated numbers needed to screen to obtain 100 amyloid PET-positive individuals. Of the 502 individuals assessed, 441 dementia-free individuals with complete data were included; 82 (18.6%) were amyloid PET-positive. The area under the curve for amyloid PET status using a base model comprising age, sex and APOE ε4 carrier status was 0.695 (95% confidence interval: 0.628-0.762). The two best-performing Simoa plasma biomarkers were amyloid-ß42/40 (0.620; 0.548-0.691) and phospho-tau181 (0.707; 0.646-0.768), but neither outperformed the base model. Mass spectrometry plasma measures performed significantly better than any other measure (amyloid-ß1-42/1-40: 0.817; 0.770-0.864 and amyloid-ß composite: 0.820; 0.775-0.866). At a cut-off point of 0.095, mass spectrometry measures of amyloid-ß1-42/1-40 detected amyloid PET positivity with 86.6% sensitivity and 71.9% specificity. Without screening, to obtain 100 PET-positive individuals from a population with similar amyloid PET positivity prevalence to Insight 46, 543 PET scans would need to be performed. Screening using age, sex and APOE ε4 status would require 940 individuals, of whom 266 would proceed to scan. Using mass spectrometry amyloid-ß1-42/1-40 alone would reduce these numbers to 623 individuals and 243 individuals, respectively. Across a theoretical range of amyloid PET positivity prevalence of 10-50%, mass spectrometry measures of amyloid-ß1-42/1-40 would consistently reduce the numbers proceeding to scans, with greater cost savings demonstrated at lower prevalence.


Asunto(s)
Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Péptidos beta-Amiloides/sangre , Fragmentos de Péptidos/sangre , Anciano , Enfermedad de Alzheimer/metabolismo , Biomarcadores/sangre , Diagnóstico Precoz , Femenino , Pruebas Hematológicas/métodos , Humanos , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad
5.
Eur J Nucl Med Mol Imaging ; 47(8): 1885-1912, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32388612

RESUMEN

PURPOSE: This joint practice guideline or procedure standard was developed collaboratively by the European Association of Nuclear Medicine (EANM) and the Society of Nuclear Medicine and Molecular Imaging (SNMMI). The goal of this guideline is to assist nuclear medicine practitioners in recommending, performing, interpreting, and reporting the results of dopaminergic imaging in parkinsonian syndromes. METHODS: Currently nuclear medicine investigations can assess both presynaptic and postsynaptic function of dopaminergic synapses. To date both EANM and SNMMI have published procedural guidelines for dopamine transporter imaging with single photon emission computed tomography (SPECT) (in 2009 and 2011, respectively). An EANM guideline for D2 SPECT imaging is also available (2009). Since the publication of these previous guidelines, new lines of evidence have been made available on semiquantification, harmonization, comparison with normal datasets, and longitudinal analyses of dopamine transporter imaging with SPECT. Similarly, details on acquisition protocols and simplified quantification methods are now available for dopamine transporter imaging with PET, including recently developed fluorinated tracers. Finally, [18F]fluorodopa PET is now used in some centers for the differential diagnosis of parkinsonism, although procedural guidelines aiming to define standard procedures for [18F]fluorodopa imaging in this setting are still lacking. CONCLUSION: All these emerging issues are addressed in the present procedural guidelines for dopaminergic imaging in parkinsonian syndromes.


Asunto(s)
Medicina Nuclear , Trastornos Parkinsonianos , Humanos , Imagen Molecular , Trastornos Parkinsonianos/diagnóstico por imagen , Cintigrafía , Tomografía Computarizada de Emisión de Fotón Único
6.
BMC Neurol ; 17(1): 75, 2017 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-28420323

RESUMEN

BACKGROUND: Increasing age is the biggest risk factor for dementia, of which Alzheimer's disease is the commonest cause. The pathological changes underpinning Alzheimer's disease are thought to develop at least a decade prior to the onset of symptoms. Molecular positron emission tomography and multi-modal magnetic resonance imaging allow key pathological processes underpinning cognitive impairment - including ß-amyloid depostion, vascular disease, network breakdown and atrophy - to be assessed repeatedly and non-invasively. This enables potential determinants of dementia to be delineated earlier, and therefore opens a pre-symptomatic window where intervention may prevent the onset of cognitive symptoms. METHODS/DESIGN: This paper outlines the clinical, cognitive and imaging protocol of "Insight 46", a neuroscience sub-study of the MRC National Survey of Health and Development. This is one of the oldest British birth cohort studies and has followed 5362 individuals since their birth in England, Scotland and Wales during one week in March 1946. These individuals have been tracked in 24 waves of data collection incorporating a wide range of health and functional measures, including repeat measures of cognitive function. Now aged 71 years, a small fraction have overt dementia, but estimates suggest that ~1/3 of individuals in this age group may be in the preclinical stages of Alzheimer's disease. Insight 46 is recruiting 500 study members selected at random from those who attended a clinical visit at 60-64 years and on whom relevant lifecourse data are available. We describe the sub-study design and protocol which involves a prospective two time-point (0, 24 month) data collection covering clinical, neuropsychological, ß-amyloid positron emission tomography and magnetic resonance imaging, biomarker and genetic information. Data collection started in 2015 (age 69) and aims to be completed in 2019 (age 73). DISCUSSION: Through the integration of data on the socioeconomic environment and on physical, psychological and cognitive function from 0 to 69 years, coupled with genetics, structural and molecular imaging, and intensive cognitive and neurological phenotyping, Insight 46 aims to identify lifetime factors which influence brain health and cognitive ageing, with particular focus on Alzheimer's disease and cerebrovascular disease. This will provide an evidence base for the rational design of disease-modifying trials.


Asunto(s)
Diagnóstico Precoz , Proyectos de Investigación , Anciano , Enfermedad de Alzheimer/diagnóstico , Biomarcadores/análisis , Demencia/diagnóstico , Inglaterra , Femenino , Humanos , Masculino , Persona de Mediana Edad , Escocia
7.
Eur J Nucl Med Mol Imaging ; 43(7): 1315-22, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26780619

RESUMEN

PURPOSE: Even though [(123)I]FP-CIT SPECT provides high accuracy in detecting nigrostriatal cell loss in neurodegenerative parkinsonian syndromes (PS), some patients with an inconclusive diagnosis remain. We investigated whether the diagnostic accuracy in patients with clinically uncertain PS with previously inconclusive findings can be improved by the use of iterative reconstruction algorithms and an improved semiquantitative evaluation which additionally implemented a correction algorithm for patient age and gamma camera dependency (EARL-BRASS; Hermes Medical Solutions, Sweden). METHODS: We identified 101 patients with inconclusive findings who underwent an [(123)I]FP-CIT SPECT between 2003 and 2010 as part of the diagnostic process of suspected PS at the University of Munich, and re-evaluated these scans using iterative reconstruction algorithms and the new corrected EARL-BRASS. Clinical follow-up was obtained in 62 out of the 101 patients and constituted the gold standard for the re-evaluation to assess the possible improvement in diagnostic accuracy. RESULTS: Clinical follow-up confirmed the diagnosis of PS in 11 of the 62 patients. In patients in whom both visual and semiquantitative analysis showed concordant findings (48 patients), a high negative predictive value (93 %), positive predictive value (100 %) and accuracy (94 %) were found, and thus a correct diagnosis was obtained in 45 of the 48 patients. Among the 14 patients with discordant findings, the additional semiquantitative analysis correctly identified all five of nine patients patients without PS by nonpathological semiquantitative findings in visually pathological or inconclusive scans. In contrast, four of the remaining five patients with decreased semiquantitative values but visually normal scans did not show a PS during follow-up. CONCLUSION: The age-corrected and camera-corrected mode of evaluation using EARL-BRASS provided a notable improvement in the diagnostic accuracy of [(123)I]FP-CIT SPECT in PS patients with previously inconclusive findings. The gain in accuracy might be achieved by better discrimination between physiological low striatal [(123)I]FP-CIT binding due to age-related loss of the dopamine transporter or pathological loss of binding.


Asunto(s)
Bases de Datos Factuales , Trastornos Parkinsonianos/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Tropanos , Incertidumbre , Estudios de Casos y Controles , Europa (Continente) , Femenino , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
8.
Eur J Nucl Med Mol Imaging ; 41(6): 1176-89, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24425423

RESUMEN

PURPOSE: To assess the quantitative accuracy of current MR attenuation correction (AC) methods in neurological PET, in comparison to data derived using CT AC. METHODS: This retrospective study included 25 patients who were referred for a neurological FDG PET examination and were imaged sequentially by PET/CT and simultaneous PET/MR. Differences between activity concentrations derived using Dixon and ultrashort echo time (UTE) MR-based AC and those derived from CT AC were compared using volume of interest and voxel-based approaches. The same comparisons were also made using PET data represented as SUV ratios (SUVr) using grey matter cerebellum as the reference region. RESULTS: Extensive and statistically significant regional underestimations of activity concentrations were found with both Dixon AC (P < 0.001) and UTE AC (P < 0.001) in all brain regions when compared to CT AC. The greatest differences were found in the cortical grey matter (Dixon AC 21.3%, UTE AC 15.7%) and cerebellum (Dixon AC 19.8%, UTE AC 17.3%). The underestimation using UTE AC was significantly less than with Dixon AC (P < 0.001) in most regions. Voxel-based comparisons showed that all cortical grey matter and cerebellum uptake was underestimated with Dixon AC compared to CT AC. Using UTE AC the extent and significance of these differences were reduced. Inaccuracies in cerebellar activity concentrations led to a mixture of predominantly cortical underestimation and subcortical overestimation in SUVr PET data for both MR AC methodologies. CONCLUSION: MR-based AC results in significant underestimation of activity concentrations throughout the brain, which makes the use of SUVr data difficult. These effects limit the quantitative accuracy of neurological PET/MR.


Asunto(s)
Cerebelo/diagnóstico por imagen , Corteza Cerebral/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Masculino , Persona de Mediana Edad , Radiofármacos/farmacocinética , Sensibilidad y Especificidad
9.
Eur J Nucl Med Mol Imaging ; 41(10): 1938-46, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24806112

RESUMEN

PURPOSE: Apart from binding to the dopamine transporter (DAT), [(123)I]FP-CIT shows moderate affinity for the serotonin transporter (SERT), allowing imaging of both monoamine transporters in a single imaging session in different brain areas. The aim of this study was to systematically evaluate extrastriatal binding (predominantly due to SERT) and its age and gender dependencies in a large cohort of healthy controls. METHODS: SPECT data from 103 healthy controls with well-defined criteria of normality acquired at 13 different imaging centres were analysed for extrastriatal binding using volumes of interest analysis for the thalamus and the pons. Data were examined for gender and age effects as well as for potential influence of striatal DAT radiotracer binding. RESULTS: Thalamic binding was significantly higher than pons binding. Partial correlations showed an influence of putaminal DAT binding on measured binding in the thalamus but not on the pons. Data showed high interindividual variation in extrastriatal binding. Significant gender effects with 31 % higher binding in women than in men were observed in the thalamus, but not in the pons. An age dependency with a decline per decade (±standard error) of 8.2 ± 1.3 % for the thalamus and 6.8 ± 2.9 % for the pons was shown. CONCLUSION: The potential to evaluate extrastriatal predominant SERT binding in addition to the striatal DAT in a single imaging session was shown using a large database of [(123)I]FP-CIT scans in healthy controls. For both the thalamus and the pons, an age-related decline in radiotracer binding was observed. Gender effects were demonstrated for binding in the thalamus only. As a potential clinical application, the data could be used as a reference to estimate SERT occupancy in addition to nigrostriatal integrity when using [(123)I]FP-CIT for DAT imaging in patients treated with selective serotonin reuptake inhibitors.


Asunto(s)
Neostriado/diagnóstico por imagen , Puente/diagnóstico por imagen , Radiofármacos/farmacocinética , Tálamo/diagnóstico por imagen , Tropanos/farmacocinética , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Especificidad de Órganos , Unión Proteica , Proteínas de Transporte de Serotonina en la Membrana Plasmática/metabolismo , Factores Sexuales , Tomografía Computarizada de Emisión de Fotón Único
10.
EJNMMI Phys ; 11(1): 74, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39177939

RESUMEN

BACKGROUND: Unilateral condylar hyperplasia (UCH) of the mandible is a rare condition characterized by asymmetric growth of the mandibular condyles. Bone scintigraphy with SPECT(/CT) is commonly used to diagnose UCH and guide treatment. Still, varying results have been reported using the traditional threshold of 55%:45% in relative tracer uptake. While absolute quantification of uptake on SPECT/CT could improve results, optimal correction and reconstruction settings are currently unknown. METHODS: Three anthropomorphic phantoms representing UCH were developed from patient CT volumes and produced using 3D printing technology. Fillable spherical inserts of different sizes (Ø: 8-15 mm) were placed in the condylar positions representing symmetrical and asymmetrical distributions. Recovery coefficients were determined for SPECT/CT using various reconstruction corrections, including attenuation and scatter correction (ACSC), resolution modeling (RM), and partial volume correction (PVC) using phantom measurements. Uptake ratios between condyles and condyle to clivus were evaluated. Finally, the impact of these correction techniques on absolute activity and diagnostic accuracy was assessed in a retrospective patient cohort for the diagnostic threshold of 55%:45%. RESULTS: The activity was only partially recovered in all spherical inserts (range: 22.5-64.9%). However, RM improved relative recovery by 20.2-62.3% compared to ACSC. In the symmetric phantoms, the 95% confidence interval (CI) of condyle ratios included the diagnostic threshold (57.6%:42.4%) for UCH when using ACSC potentially leading to false positives, but not for ACSCRM datasets. Partial volume corrections coefficients from the NEMA IQ phantom was positionally dependent, with improvements seen performing PVC using coefficients derived from anthropomorphic phantoms. Retrospective application in a patient cohort showed only a weak linear correlation (R²: 0.25-0.67) and large limits of agreement (9.6-12.5%) between different reconstructions. Up to 44% of patients were reclassified using the 55%:45% threshold. Using clinical outcome data, ACSCRM had highest sensitivity (91%; 95% CI 59-100%) and specificity (66%; 95% CI 47-81%), significantly improving specificity (P = 0.038). CONCLUSIONS: Anthropomorphic phantoms were shown to be essential in determining optimal settings for acquisition, reconstruction, and analysis. SPECT/CT reconstructions with attenuation and scatter correction and resolution modeling are recommended and could improve specificity when using the 55%:45% threshold to assess condylar growth.

11.
Neurology ; 102(11): e209453, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38759132

RESUMEN

BACKGROUND AND OBJECTIVES: Degeneration of the presynaptic nigrostriatal dopaminergic system is one of the main biological features of Parkinson disease (PD), multiple system atrophy (MSA), progressive supranuclear palsy (PSP), and corticobasal degeneration (CBD), which can be measured using single-photon emission CT imaging for diagnostic purposes. Despite its widespread use in clinical practice and research, the diagnostic properties of presynaptic nigrostriatal dopaminergic (DAT) imaging in parkinsonism have never been evaluated against the diagnostic gold standard of neuropathology. The aim of this study was to evaluate the diagnostic parameters of DAT imaging compared with pathologic diagnosis in patients with parkinsonism. METHODS: Retrospective cohort study of patients with DAT imaging for the investigation of a clinically uncertain parkinsonism with brain donation between 2010 and 2021 to the Queen Square Brain Bank (London). Patients with DAT imaging for investigation of pure ataxia or dementia syndromes without parkinsonism were excluded. Those with a pathologic diagnosis of PD, MSA, PSP, or CBD were considered presynaptic dopaminergic parkinsonism, and other pathologies were considered postsynaptic for the analysis. DAT imaging was performed in routine clinical practice and visually classified by hospital nuclear medicine specialists as normal or abnormal. The results were correlated with neuropathologic diagnosis to calculate diagnostic accuracy parameters for the diagnosis of presynaptic dopaminergic parkinsonism. RESULTS: All of 47 patients with PD, 41 of 42 with MSA, 68 of 73 with PSP, and 6 of 10 with CBD (sensitivity 100%, 97.6%, 93.2%, and 60%, respectively) had abnormal presynaptic dopaminergic imaging. Eight of 17 patients with presumed postsynaptic parkinsonism had abnormal scans (specificity 52.9%). DISCUSSION: DAT imaging has very high sensitivity and negative predictive value for the diagnosis of presynaptic dopaminergic parkinsonism, particularly for PD. However, patients with CBD, and to a lesser extent PSP (of various phenotypes) and MSA (with predominant ataxia), can show normal DAT imaging. A range of other neurodegenerative disorders may have abnormal DAT scans with low specificity in the differential diagnosis of parkinsonism. DAT imaging is a useful diagnostic tool in the differential diagnosis of parkinsonism, although clinicians should be aware of its diagnostic properties and limitations. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that DAT imaging does not accurately distinguish between presynaptic dopaminergic parkinsonism and non-presynaptic dopaminergic parkinsonism.


Asunto(s)
Proteínas de Transporte de Dopamina a través de la Membrana Plasmática , Atrofia de Múltiples Sistemas , Trastornos Parkinsonianos , Tomografía Computarizada de Emisión de Fotón Único , Humanos , Femenino , Anciano , Masculino , Estudios Retrospectivos , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Trastornos Parkinsonianos/diagnóstico por imagen , Trastornos Parkinsonianos/patología , Trastornos Parkinsonianos/metabolismo , Tomografía Computarizada de Emisión de Fotón Único/métodos , Persona de Mediana Edad , Atrofia de Múltiples Sistemas/diagnóstico por imagen , Atrofia de Múltiples Sistemas/patología , Atrofia de Múltiples Sistemas/metabolismo , Parálisis Supranuclear Progresiva/diagnóstico por imagen , Parálisis Supranuclear Progresiva/patología , Parálisis Supranuclear Progresiva/metabolismo , Anciano de 80 o más Años , Enfermedad de Parkinson/diagnóstico por imagen , Enfermedad de Parkinson/metabolismo , Enfermedad de Parkinson/patología , Estudios de Cohortes , Degeneración Corticobasal/diagnóstico por imagen , Degeneración Corticobasal/metabolismo , Dopamina/metabolismo , Terminales Presinápticos/metabolismo , Terminales Presinápticos/patología , Sensibilidad y Especificidad , Imágenes Dopaminérgicas
12.
Neuroimage ; 64: 61-7, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-22982354

RESUMEN

INTRODUCTION: Dopamine is one among several neurotransmitters that regulate food intake and overeating. Thus, it has been linked to the pathophysiology of obesity and high body mass index (BMI). Striatal dopamine D(2) receptor availability is lower in obesity and there are indications that striatal dopamine transporter (DAT) availability is also decreased. In this study, we tested whether BMI and striatal DAT availability are associated. METHODS: The study included 123 healthy individuals from a large European multi-center database. They had a BMI range of 18.2-41.1 kg/m(2) and were scanned using [(123)I]FP-CIT SPECT imaging. Scans were analyzed with both region-of-interest and voxel-based analysis to determine the binding potential for DAT availability in the caudate nucleus and putamen. A direct relation between BMI and DAT availability was assessed and groups with high and low BMI were compared for DAT availability. RESULTS: No association between BMI and striatal DAT availability was found. CONCLUSION: The lack of an association between BMI and striatal DAT availability suggests that the regulation of striatal synaptic dopamine levels by DAT plays no or a limited role in the pathophysiology of overweight and obesity.


Asunto(s)
Envejecimiento/metabolismo , Índice de Masa Corporal , Cuerpo Estriado/metabolismo , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Tropanos/farmacocinética , Adulto , Anciano , Anciano de 80 o más Años , Cuerpo Estriado/diagnóstico por imagen , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cintigrafía , Radiofármacos/farmacocinética , Distribución Tisular
13.
Eur J Nucl Med Mol Imaging ; 40(2): 213-27, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23160999

RESUMEN

PURPOSE: Dopamine transporter (DAT) imaging with [(123)I]FP-CIT (DaTSCAN) is an established diagnostic tool in parkinsonism and dementia. Although qualitative assessment criteria are available, DAT quantification is important for research and for completion of a diagnostic evaluation. One critical aspect of quantification is the availability of normative data, considering possible age and gender effects on DAT availability. The aim of the European Normal Control Database of DaTSCAN (ENC-DAT) study was to generate a large database of [(123)I]FP-CIT SPECT scans in healthy controls. METHODS: SPECT data from 139 healthy controls (74 men, 65 women; age range 20-83 years, mean 53 years) acquired in 13 different centres were included. Images were reconstructed using the ordered-subset expectation-maximization algorithm without correction (NOACSC), with attenuation correction (AC), and with both attenuation and scatter correction using the triple-energy window method (ACSC). Region-of-interest analysis was performed using the BRASS software (caudate and putamen), and the Southampton method (striatum). The outcome measure was the specific binding ratio (SBR). RESULTS: A significant effect of age on SBR was found for all data. Gender had a significant effect on SBR in the caudate and putamen for the NOACSC and AC data, and only in the left caudate for the ACSC data (BRASS method). Significant effects of age and gender on striatal SBR were observed for all data analysed with the Southampton method. Overall, there was a significant age-related decline in SBR of between 4 % and 6.7 % per decade. CONCLUSION: This study provides a large database of [(123)I]FP-CIT SPECT scans in healthy controls across a wide age range and with balanced gender representation. Higher DAT availability was found in women than in men. An average age-related decline in DAT availability of 5.5 % per decade was found for both genders, in agreement with previous reports. The data collected in this study may serve as a reference database for nuclear medicine centres and for clinical trials using [(123)I]FP-CIT SPECT as the imaging marker.


Asunto(s)
Encéfalo/patología , Valores de Referencia , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tropanos/farmacología , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Calibración , Estudios de Casos y Controles , Bases de Datos Factuales , Demencia/diagnóstico , Demencia/diagnóstico por imagen , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Femenino , Humanos , Radioisótopos de Yodo/farmacología , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Medicina Nuclear/métodos , Trastornos Parkinsonianos/diagnóstico , Trastornos Parkinsonianos/diagnóstico por imagen , Factores Sexuales
14.
Nucl Med Commun ; 44(10): 834-842, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37464866

RESUMEN

OBJECTIVES: With disease-modifying therapies in development for neurological disorders, quantitative brain imaging techniques become increasingly relevant for objective early diagnosis and assessment of response to treatment. The aim of this study was to evaluate the use of Brain SPECT and PET scans in the UK and explore drivers and barriers to using quantitative analysis through an online survey. METHODS: A web-based survey with 27 questions was used to capture a snapshot of brain imaging in the UK. The survey included multiple-choice questions assessing the availability and use of quantification for DaTscan, Perfusion SPECT, FDG PET and Amyloid PET. The survey results were reviewed and interpreted by a panel of imaging experts. RESULTS: Forty-six unique responses were collected and analysed, with 84% of responses from brain imaging sites. Within these sites, 88% perform DaTscan, 50% Perfusion SPECT, 48% FDG PET, and 33% Amyloid PET, while a few sites use other PET tracers. Quantitative Brain analysis is used in 86% of sites performing DaTscans, 40% for Perfusion SPECT, 63% for FDG PET and 42% for Amyloid PET. Commercial tools are used more frequently than in-house software. CONCLUSION: The survey showed variations across the UK, with high availability of DaTscan imaging and quantification and lower availability of other SPECT and PET scans. The main drivers for quantification were improved reporting confidence and diagnostic accuracy, while the main barriers were a perception of a need for an appropriate database of healthy controls and a lack of training, time, and software availability.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Amiloide , Reino Unido
15.
Neurology ; 99(2): e129-e141, 2022 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-35410910

RESUMEN

BACKGROUND AND OBJECTIVES: The goals of this work were to quantify the independent and interactive associations of ß-amyloid (Aß) and white matter hyperintensity volume (WMHV), a marker of presumed cerebrovascular disease (CVD), with rates of neurodegeneration and to examine the contributions of APOE ε4 and vascular risk measured at different stages of adulthood in cognitively normal members of the 1946 British Birth Cohort. METHODS: Participants underwent brain MRI and florbetapir-Aß PET as part of Insight 46, an observational population-based study. Changes in whole-brain, ventricular, and hippocampal volume were directly measured from baseline and repeat volumetric T1 MRI with the boundary shift integral. Linear regression was used to test associations with baseline Aß deposition, baseline WMHV, APOE ε4, and office-based Framingham Heart Study Cardiovascular Risk Score (FHS-CVS) and systolic blood pressure (BP) at ages 36, 53, and 69 years. RESULTS: Three hundred forty-six cognitively normal participants (mean [SD] age at baseline scan 70.5 [0.6] years; 48% female) had high-quality T1 MRI data from both time points (mean [SD] scan interval 2.4 [0.2] years). Being Aß positive at baseline was associated with 0.87-mL/y faster whole-brain atrophy (95% CI 0.03, 1.72), 0.39-mL/y greater ventricular expansion (95% CI 0.16, 0.64), and 0.016-mL/y faster hippocampal atrophy (95% CI 0.004, 0.027), while each 10-mL additional WMHV at baseline was associated with 1.07-mL/y faster whole-brain atrophy (95% CI 0.47, 1.67), 0.31-mL/y greater ventricular expansion (95% CI 0.13, 0.60), and 0.014-mL/y faster hippocampal atrophy (95% CI 0.006, 0.022). These contributions were independent, and there was no evidence that Aß and WMHV interacted in their effects. There were no independent associations of APOE ε4 with rates of neurodegeneration after adjustment for Aß status and WMHV, no clear relationships between FHS-CVS or systolic BP and rates of neurodegeneration when assessed across the whole sample, and no evidence that FHS-CVS or systolic BP acted synergistically with Aß. DISCUSSION: Aß and presumed CVD have distinct and additive effects on rates of neurodegeneration in cognitively normal elderly. These findings have implications for the use of MRI measures as biomarkers of neurodegeneration and emphasize the importance of risk management and early intervention targeting both pathways.


Asunto(s)
Enfermedad de Alzheimer , Trastornos Cerebrovasculares , Anciano , Enfermedad de Alzheimer/patología , Péptidos beta-Amiloides/metabolismo , Apolipoproteína E4/genética , Atrofia/patología , Cohorte de Nacimiento , Encéfalo/patología , Trastornos Cerebrovasculares/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Tomografía de Emisión de Positrones
17.
Eur J Nucl Med Mol Imaging ; 38(8): 1529-40, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21468761

RESUMEN

PURPOSE: A joint initiative of the European Association of Nuclear Medicine (EANM) Neuroimaging Committee and EANM Research Ltd. aimed to generate a European database of [(123)I]FP-CIT single photon emission computed tomography (SPECT) scans of healthy controls. This study describes the characterization and harmonization of the imaging equipment of the institutions involved. METHODS: (123)I SPECT images of a striatal phantom filled with striatal to background ratios between 10:1 and 1:1 were acquired on all the gamma cameras with absolute ratios measured from aliquots. The images were reconstructed by a core lab using ordered subset expectation maximization (OSEM) without corrections (NC), with attenuation correction only (AC) and additional scatter and septal penetration correction (ACSC) using the triple energy window method. A quantitative parameter, the simulated specific binding ratio (sSBR), was measured using the "Southampton" methodology that accounts for the partial volume effect and compared against the actual values obtained from the aliquots. Camera-specific recovery coefficients were derived from linear regression and the error of the measurements was evaluated using the coefficient of variation (COV). RESULTS: The relationship between measured and actual sSBRs was linear across all systems. Variability was observed between different manufacturers and, to a lesser extent, between cameras of the same type. The NC and AC measurements were found to underestimate systematically the actual sSBRs, while the ACSC measurements resulted in recovery coefficients close to 100% for all cameras (AC range 69-89%, ACSC range 87-116%). The COV improved from 46% (NC) to 32% (AC) and to 14% (ACSC) (p < 0.001). CONCLUSION: A satisfactory linear response was observed across all cameras. Quantitative measurements depend upon the characteristics of the SPECT systems and their calibration is a necessary prerequisite for data pooling. Together with accounting for partial volume, the correction for scatter and septal penetration is essential for accurate quantification.


Asunto(s)
Bases de Datos Factuales , Cámaras gamma/normas , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/normas , Tropanos , Calibración , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Europa (Continente) , Humanos , Estándares de Referencia
18.
Diagnostics (Basel) ; 11(12)2021 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-34943570

RESUMEN

The application of absolute quantification in SPECT/CT has seen increased interest in the context of radionuclide therapies where patient-specific dosimetry is a requirement within the European Union (EU) legislation. However, the translation of this technique to diagnostic nuclear medicine outside this setting is rather slow. Clinical research has, in some examples, already shown an association between imaging metrics and clinical diagnosis, but the applications, in general, lack proper validation because of the absence of a ground truth measurement. Meanwhile, additive manufacturing or 3D printing has seen rapid improvements, increasing its uptake in medical imaging. Three-dimensional printed phantoms have already made a significant impact on quantitative imaging, a trend that is likely to increase in the future. In this review, we summarize the data of recent literature to underpin our premise that the validation of diagnostic applications in nuclear medicine using application-specific phantoms is within reach given the current state-of-the-art in additive manufacturing or 3D printing.

19.
Eur J Nucl Med Mol Imaging ; 37(1): 23-35, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19618181

RESUMEN

PURPOSE: Reconstruction of DaTSCAN brain studies using OS-EM iterative reconstruction offers better image quality and more accurate quantification than filtered back-projection. However, reconstruction must proceed for a sufficient number of iterations to achieve stable and accurate data. This study assessed the impact of the number of iterations on the image quantification, comparing the results of the iterative reconstruction with filtered back-projection data. METHODS: A striatal phantom filled with (123)I using striatal to background ratios between 2:1 and 10:1 was imaged on five different gamma camera systems. Data from each system were reconstructed using OS-EM (which included depth-independent resolution recovery) with various combinations of iterations and subsets to achieve up to 200 EM-equivalent iterations and with filtered back-projection. Using volume of interest analysis, the relationships between image reconstruction strategy and quantification of striatal uptake were assessed. RESULTS: For phantom filling ratios of 5:1 or less, significant convergence of measured ratios occurred close to 100 EM-equivalent iterations, whereas for higher filling ratios, measured uptake ratios did not display a convergence pattern. Assessment of the count concentrations used to derive the measured uptake ratio showed that nonconvergence of low background count concentrations caused peaking in higher measured uptake ratios. Compared to filtered back-projection, OS-EM displayed larger uptake ratios because of the resolution recovery applied in the iterative algorithm. CONCLUSION: The number of EM-equivalent iterations used in OS-EM reconstruction influences the quantification of DaTSCAN studies because of incomplete convergence and possible bias in areas of low activity due to the nonnegativity constraint in OS-EM reconstruction. Nevertheless, OS-EM using 100 EM-equivalent iterations provides the best linear discriminatory measure to quantify the uptake in DaTSCAN studies.


Asunto(s)
Algoritmos , Cuerpo Estriado/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tropanos , Humanos , Fantasmas de Imagen , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/instrumentación
20.
Stem Cell Res Ther ; 11(1): 256, 2020 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-32586403

RESUMEN

BACKGROUND: MSCTRAIL is a cell-based therapy consisting of human allogeneic umbilical cord-derived MSCs genetically modified to express the anti-cancer protein TRAIL. Though cell-based therapies are typically designed with a target tissue in mind, delivery is rarely assessed due to a lack of translatable non-invasive imaging approaches. In this preclinical study, we demonstrate 89Zr-oxine labelling and PET-CT imaging as a potential clinical solution for non-invasively tracking MSCTRAIL biodistribution. Future implementation of this technique should improve our understanding of MSCTRAIL during its evaluation as a therapy for metastatic lung adenocarcinoma. METHODS: MSCTRAIL were radiolabelled with 89Zr-oxine and assayed for viability, phenotype, and therapeutic efficacy post-labelling. PET-CT imaging of 89Zr-oxine-labelled MSCTRAIL was performed in a mouse model of lung cancer following intravenous injection, and biodistribution was confirmed ex vivo. RESULTS: MSCTRAIL retained the therapeutic efficacy and MSC phenotype in vitro at labelling amounts up to and above those required for clinical imaging. The effect of 89Zr-oxine labelling on cell proliferation rate was amount- and time-dependent. PET-CT imaging showed delivery of MSCTRAIL to the lungs in a mouse model of lung cancer up to 1 week post-injection, validated by in vivo bioluminescence imaging, autoradiography, and fluorescence imaging on tissue sections. CONCLUSIONS: 89Zr-oxine labelling and PET-CT imaging present a potential method of evaluating the biodistribution of new cell therapies in patients, including MSCTRAIL. This offers to improve understanding of cell therapies, including mechanism of action, migration dynamics, and inter-patient variability.


Asunto(s)
Neoplasias Pulmonares , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Pulmón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Oxiquinolina , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA