Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
ACS Nano ; 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38335120

RESUMEN

Electrical biosensors, including transistor-based devices (i.e., BioFETs), have the potential to offer versatile biomarker detection in a simple, low-cost, scalable, and point-of-care manner. Semiconducting carbon nanotubes (CNTs) are among the most explored nanomaterial candidates for BioFETs due to their high electrical sensitivity and compatibility with diverse fabrication approaches. However, when operating in solutions at biologically relevant ionic strengths, CNT-based BioFETs suffer from debilitating levels of signal drift and charge screening, which are often unaccounted for or sidestepped (but not addressed) by testing in diluted solutions. In this work, we present an ultrasensitive CNT-based BioFET called the D4-TFT, an immunoassay with an electrical readout, which overcomes charge screening and drift-related limitations of BioFETs. In high ionic strength solution (1X PBS), the D4-TFT repeatedly and stably detects subfemtomolar biomarker concentrations in a point-of-care form factor by increasing the sensing distance in solution (Debye length) and mitigating signal drift effects. Debye length screening and biofouling effects are overcome using a poly(ethylene glycol)-like polymer brush interface (POEGMA) above the device into which antibodies are printed. Simultaneous testing of a control device having no antibodies printed over the CNT channel confirms successful detection of the target biomarker via an on-current shift caused by antibody sandwich formation. Drift in the target signal is mitigated by a combination of: (1) maximizing sensitivity by appropriate passivation alongside the polymer brush coating; (2) using a stable electrical testing configuration; and (3) enforcing a rigorous testing methodology that relies on infrequent DC sweeps rather than static or AC measurements. These improvements are realized in a relatively simple device using printed CNTs and antibodies for a low-cost, versatile platform for the ongoing pursuit of point-of-care BioFETs.

2.
Microsyst Nanoeng ; 10: 2, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38169478

RESUMEN

The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA