Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Magn Reson Med ; 90(2): 483-501, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37093775

RESUMEN

PURPOSE: To improve time-resolved reconstructions by training auto-encoders to learn compact representations of Bloch-simulated signal evolution and inserting the decoder into the forward model. METHODS: Building on model-based nonlinear and linear subspace techniques, we train auto-encoders on dictionaries of simulated signal evolution to learn compact, nonlinear, latent representations. The proposed latent signal model framework inserts the decoder portion of the auto-encoder into the forward model and directly reconstructs the latent representation. Latent signal models essentially serve as a proxy for fast and feasible differentiation through the Bloch equations used to simulate signal. This work performs experiments in the context of T2 -shuffling, gradient echo EPTI, and MPRAGE-shuffling. We compare how efficiently auto-encoders represent signal evolution in comparison to linear subspaces. Simulation and in vivo experiments then evaluate if reducing degrees of freedom by incorporating our proxy for the Bloch equations, the decoder portion of the auto-encoder, into the forward model improves reconstructions in comparison to subspace constraints. RESULTS: An auto-encoder with 1 real latent variable represents single-tissue fast spin echo, EPTI, and MPRAGE signal evolution to within 0.15% normalized RMS error, enabling reconstruction problems with 3 degrees of freedom per voxel (real latent variable + complex scaling) in comparison to linear models with 4-8 degrees of freedom per voxel. In simulated/in vivo T2 -shuffling and in vivo EPTI experiments, the proposed framework achieves consistent quantitative normalized RMS error improvement over linear approaches. From qualitative evaluation, the proposed approach yields images with reduced blurring and noise amplification in MPRAGE-shuffling experiments. CONCLUSION: Directly solving for nonlinear latent representations of signal evolution improves time-resolved MRI reconstructions.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Simulación por Computador , Procesamiento de Imagen Asistido por Computador/métodos
2.
Neuroimage ; 250: 118963, 2022 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-35122969

RESUMEN

Multi-parametric quantitative MRI has shown great potential to improve the sensitivity and specificity of clinical diagnosis and to enhance our understanding of complex brain processes, but suffers from long scan time especially at high spatial resolution. To address this longstanding challenge, we introduce a novel approach, termed 3D Echo Planar Time-resolved Imaging (3D-EPTI), which significantly increases the acceleration capacity of MRI sampling, and provides high acquisition efficiency for multi-parametric MRI. This is achieved by exploiting the spatiotemporal correlation of MRI data at multiple timescales through new encoding strategies within and between efficient continuous readouts. Specifically, an optimized spatiotemporal CAIPI encoding within the readouts combined with a radial-block sampling strategy across the readouts enables an acceleration rate of 800 fold in the k-t space. A subspace reconstruction was employed to resolve thousands of high-quality multi-contrast images. We have demonstrated the ability of 3D-EPTI to provide robust and repeatable whole-brain simultaneous T1, T2, T2*, PD and B1+ mapping at high isotropic resolution within minutes (e.g., 1-mm isotropic resolution in 3 minutes), and to enable submillimeter multi-parametric imaging to study detailed brain structures.


Asunto(s)
Mapeo Encefálico/métodos , Imagen Eco-Planar/métodos , Imagenología Tridimensional/métodos , Imágenes de Resonancia Magnética Multiparamétrica/métodos , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Magn Reson Med ; 88(3): 1112-1125, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35481604

RESUMEN

PURPOSE: To develop a motion estimation and correction method for motion-robust three-dimensional (3D) quantitative imaging with 3D-echo-planar time-resolved imaging. THEORY AND METHODS: The 3D-echo-planar time-resolved imaging technique was designed with additional four-dimensional navigator acquisition (x-y-z-echoes) to achieve fast and motion-robust quantitative imaging of the human brain. The four-dimensional-navigator is inserted into the relaxation-recovery deadtime of the sequence in every pulse TR (∼2 s) to avoid extra scan time, and to provide continuous tracking of the 3D head motion and B0 -inhomogeneity changes. By using an optimized spatiotemporal encoding combined with a partial-Fourier scheme, the navigator acquires a large central k-t data block for accurate motion estimation using only four small-flip-angle excitations and readouts, resulting in negligible signal-recovery reduction to the 3D-echo-planar time-resolved imaging acquisition. By incorporating the estimated motion and B0 -inhomogeneity changes into the reconstruction, multi-contrast images can be recovered with reduced motion artifacts. RESULTS: Simulation shows the cost to the SNR efficiency from the added navigator acquisitions is <1%. Both simulation and in vivo retrospective experiments were conducted, that demonstrate the four-dimensional navigator provided accurate estimation of the 3D motion and B0 -inhomogeneity changes, allowing effective reduction of image artifacts in quantitative maps. Finally, in vivo prospective undersampling acquisition was performed with and without head motion, in which the motion corrupted data after correction show close image quality and consistent quantifications to the motion-free scan, providing reliable quantitative measurements even with head motion. CONCLUSION: The proposed four-dimensional navigator acquisition provides reliable tracking of the head motion and B0 change with negligible SNR cost, equips the 3D-echo-planar time-resolved imaging technique for motion-robust and efficient quantitative imaging.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Estudios Retrospectivos
4.
Magn Reson Med ; 88(1): 164-179, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35225368

RESUMEN

PURPOSE: To develop an efficient acquisition technique for distortion-free diffusion MRI and diffusion-relaxometry. METHODS: A new accelerated echo-train shifted echo-planar time-resolved imaging (ACE-EPTI) technique is developed to achieve high-SNR, distortion-free diffusion, and diffusion-relaxometry imaging. ACE-EPTI uses a newly designed variable density spatiotemporal encoding with self-navigators for phase correction, that allows for submillimeter in-plane resolution using only 3-shot. Moreover, an echo-train-shifted acquisition is developed to achieve minimal TE, together with an SNR-optimal readout length, leading to ∼30% improvement in SNR efficiency over single-shot EPI. To recover the highly accelerated data with high image quality, a tailored subspace image reconstruction framework is developed, that corrects for odd/even-echo phase difference, shot-to-shot phase variation, and the B0 field changes because of field drift and eddy currents across different dynamics. After the phase-corrected subspace reconstruction, artifacts-free high-SNR diffusion images at multiple TEs are obtained with varying T2 * weighting. RESULTS: Simulation, phantom, and in vivo experiments were performed, which validated the 3-shot spatiotemporal encoding provides accurate reconstruction at submillimeter resolution. The use of echo-train shifting and optimized readout length improves the SNR-efficiency by 27%-36% over single-shot EPI. The level of image distortion was also evaluated, which shows no noticeable susceptibility and eddy-current distortions in ACE-EPTI images that are common in EPI. The time-resolved acquisition of ACE-EPTI also provides multi-TE images for diffusion-relaxometry analysis. CONCLUSION: ACE-EPTI was demonstrated to be an efficient and powerful technique for high-resolution diffusion imaging and diffusion-relaxometry, which provides high SNR, distortion- and blurring-free, and time-resolved multi-echo images by a fast 3-shot acquisition.


Asunto(s)
Encéfalo , Procesamiento de Imagen Asistido por Computador , Artefactos , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos
5.
Magn Reson Med ; 88(1): 133-150, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35199877

RESUMEN

PURPOSE: To improve image quality and accelerate the acquisition of 3D MR fingerprinting (MRF). METHODS: Building on the multi-axis spiral-projection MRF technique, a subspace reconstruction with locally low-rank constraint and a modified spiral-projection spatiotemporal encoding scheme called tiny golden-angle shuffling were implemented for rapid whole-brain high-resolution quantitative mapping. Reconstruction parameters such as the locally low-rank regularization parameter and the subspace rank were tuned using retrospective in vivo data and simulated examinations. B0 inhomogeneity correction using multifrequency interpolation was incorporated into the subspace reconstruction to further improve the image quality by mitigating blurring caused by off-resonance effect. RESULTS: The proposed MRF acquisition and reconstruction framework yields high-quality 1-mm isotropic whole-brain quantitative maps in 2 min at better quality compared with 6-min acquisitions of prior approaches. The proposed method was validated to not induce bias in T1 and T2 mapping. High-quality whole-brain MRF data were also obtained at 0.66-mm isotropic resolution in 4 min using the proposed technique, where the increased resolution was shown to improve visualization of subtle brain structures. CONCLUSIONS: The proposed tiny golden-angle shuffling, MRF with optimized spiral-projection trajectory and subspace reconstruction enables high-resolution quantitative mapping in ultrafast acquisition time.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Estudios Retrospectivos
6.
Neuroimage ; 245: 118641, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34655771

RESUMEN

Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T2' contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T2' contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T2' weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T2'-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B0 drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T2' weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity.


Asunto(s)
Mapeo Encefálico/métodos , Imagen por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Sensibilidad y Especificidad
7.
Neuroimage ; 232: 117897, 2021 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-33621694

RESUMEN

Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 µm isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Vaina de Mielina/metabolismo , Humanos , Estudios Retrospectivos , Agua/metabolismo
8.
Magn Reson Med ; 84(5): 2442-2455, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32333478

RESUMEN

PURPOSE: To develop new encoding and reconstruction techniques for fast multi-contrast/quantitative imaging. METHODS: The recently proposed Echo Planar Time-resolved Imaging (EPTI) technique can achieve fast distortion- and blurring-free multi-contrast/quantitative imaging. In this work, a subspace reconstruction framework is developed to improve the reconstruction accuracy of EPTI at high encoding accelerations. The number of unknowns in the reconstruction is significantly reduced by modeling the temporal signal evolutions using low-rank subspace. As part of the proposed reconstruction approach, a B0 -update algorithm and a shot-to-shot B0 variation correction method are developed to enable the reconstruction of high-resolution tissue phase images and to mitigate artifacts from shot-to-shot phase variations. Moreover, the EPTI concept is extended to 3D k-space for 3D GE-EPTI, where a new "temporal-variant" of CAIPI encoding is proposed to further improve performance. RESULTS: The effectiveness of the proposed subspace reconstruction was demonstrated first in 2D GESE EPTI, where the reconstruction achieved higher accuracy when compared to conventional B0 -informed GRAPPA. For 3D GE-EPTI, a retrospective undersampling experiment demonstrates that the new temporal-variant CAIPI encoding can achieve up to 72× acceleration with close to 2× reduction in reconstruction error when compared to conventional spatiotemporal-CAIPI encoding. In a prospective undersampling experiment, high-quality whole-brain T2∗ and tissue phase maps at 1 mm isotropic resolution were acquired in 52 seconds at 3T using 3D GE-EPTI with temporal-variant CAIPI encoding. CONCLUSION: The proposed subspace reconstruction and optimized temporal-variant CAIPI encoding can further improve the performance of EPTI for fast quantitative mapping.


Asunto(s)
Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador , Algoritmos , Artefactos , Encéfalo/diagnóstico por imagen , Estudios Prospectivos , Estudios Retrospectivos
9.
Magn Reson Med ; 83(6): 2124-2137, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31703154

RESUMEN

PURPOSE: To develop a motion-robust extension to the recently developed echo-planar time-resolved imaging (EPTI) approach, referred to as PROPELLER EPTI with dynamic encoding (PEPTIDE), by incorporating rotations into the rapid, multishot acquisition to enable shot-to-shot motion correction. METHODS: Echo-planar time-resolved imaging is a multishot EPI-based approach that allows extremely rapid acquisition of distortion-free and blurring-free multicontrast imaging and quantitative mapping. By combining k-space encoding rotations into the EPTI sampling strategy to repeatedly sample the low-resolution k-space center, PEPTIDE enables significant tolerance to shot-to-shot motion and B0 phase variations. Retrospective PEPTIDE data sets are created through a combination of in vivo EPTI data sets with rotationally acquired protocols, to enable direct comparison of the 2 methods and their robustness to identical motion. The PEPTIDE data sets are also prospectively acquired and again compared with EPTI, in the presence of true subject motion. RESULTS: The PEPTIDE approach is shown to be motion-robust to even severe subject motion (demonstrated > 30° in-plane rotation, alongside translational and through-plane motion), while maintaining the rapid encoding benefits of the EPTI technique. The technique enables accurate quantitative maps to be calculated from even severe motion data sets. While the performance of the motion correction depends on the type and severity of motion encountered, in all cases PEPTIDE significantly increases image quality in the presence of motion comparative to conventional EPTI. CONCLUSION: The newly developed PEPTIDE technique combines a high degree of motion tolerance into the EPTI framework, enabling highly rapid acquisition of distortion-free and blurring-free images at multiple TEs in the presence of motion.


Asunto(s)
Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador , Artefactos , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Movimiento (Física) , Péptidos , Estudios Retrospectivos
10.
Magn Reson Med ; 82(1): 251-262, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30847991

RESUMEN

PURPOSE: Effective removal of chemical-shift artifacts in echo-planar imaging (EPI) is a challenging problem especially with severe field inhomogeneity. This study aims to develop a reliable water/fat separation technique for point spread function (PSF) encoded EPI (PSF-EPI) by using its intrinsic multiple echo-shifted images. THEORY AND METHODS: EPI with PSF encoding can achieve distortion-free imaging and can be highly accelerated using the tilted-CAIPI technique. In this study, the chemical-shift encoding existing in the intermediate images with different time shifts of PSF-EPI is used for water/fat separation, which is conducted with latest water/fat separation algorithms. The method was tested in T1-weighted, T2-weighted, and diffusion weighted imaging in healthy volunteers. RESULTS: The ability of the proposed method to separate water/fat using intrinsic PSF-EPI signals without extra scans was demonstrated through in vivo T1-weighted, T2-weighted, and diffusion weighted imaging experiments. By exploring different imaging contrasts and regions, the results show that this PSF-EPI based method can separate water/fat and remove fat residues robustly. CONCLUSION: By using the intrinsic signals of PSF-EPI for water/fat separation, fat signals can be effectively suppressed in EPI even with severe field inhomogeneity. This water/fat separation method for EPI can be extended to multiple image contrasts. The distortion-free PSF-EPI technique, thus, has the potential to provide anatomical and functional images with high-fidelity and practical acquisition efficiency.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Agua/química , Algoritmos , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Humanos
11.
Magn Reson Med ; 81(1): 377-392, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30229562

RESUMEN

PURPOSE: To develop a method for fast distortion- and blurring-free imaging. THEORY: EPI with point-spread-function (PSF) mapping can achieve distortion- and blurring-free imaging at a cost of long acquisition time. In this study, an acquisition/reconstruction technique, termed "tilted-CAIPI," is proposed to achieve >20× acceleration for PSF-EPI. The proposed method systematically optimized the k-space sampling trajectory with B0 -inhomogeneity-informed reconstruction, to exploit the inherent signal correlation in PSF-EPI and take full advantage of coil sensitivity. Susceptibility-induced phase accumulation is regarded as an additional encoding that is estimated by calibration data and integrated into reconstruction. Self-navigated phase correction was developed to correct shot-to-shot phase variation in diffusion imaging. METHODS: Tilted-CAIPI was implemented at 3T, with incorporation of partial Fourier and simultaneous multislice to achieve further accelerations. T2 -weighted, T2* -weighted, and diffusion-weighted imaging experiments were conducted to evaluate the proposed method. RESULTS: The ability of tilted-CAIPI to provide highly accelerated imaging without distortion and blurring was demonstrated through in vivo brain experiments, where only 8 shots per simultaneous slice group were required to provide high-quality, high-SNR imaging at 0.8-1 mm resolution. CONCLUSION: Tilted-CAIPI achieved fast distortion- and blurring-free imaging with high SNR. Whole-brain T2 -weighted, T2* -weighted, and diffusion imaging can be obtained in just 15-60 s.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Artefactos , Calibración , Imagen de Difusión por Resonancia Magnética , Análisis de Fourier , Humanos , Aumento de la Imagen/métodos , Movimiento (Física) , Fantasmas de Imagen , Estudios Retrospectivos , Relación Señal-Ruido
12.
Magn Reson Med ; 81(6): 3599-3615, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30714198

RESUMEN

PURPOSE: To develop an efficient distortion- and blurring-free multi-shot EPI technique for time-resolved multiple-contrast and/or quantitative imaging. METHODS: EPI is a commonly used sequence but suffers from geometric distortions and blurring. Here, we introduce a new multi-shot EPI technique termed echo planar time-resolved imaging (EPTI), which has the ability to rapidly acquire distortion- and blurring-free multi-contrast data set. The EPTI approach performs encoding in ky -t space and uses a new highly accelerated spatio-temporal CAIPI sampling trajectory to take advantage of signal correlation along these dimensions. Through this acquisition and a B0 -informed parallel imaging reconstruction, hundreds of "time-resolved" distortion- and blurring-free images at different TEs across the EPI readout window can be created at sub-millisecond temporal increments using a small number of EPTI shots. Moreover, a method for self-estimation and correction of shot-to-shot B0 variations was developed. Simultaneous multi-slice acquisition was also incorporated to further improve the acquisition efficiency. RESULTS: We evaluated EPTI under varying simulated acceleration factors, B0 -inhomogeneity, and shot-to-shot B0 variations to demonstrate its ability to provide distortion- and blurring-free images at multiple TEs. Two variants of EPTI were demonstrated in vivo at 3T: (1) a combined gradient- and spin-echo EPTI for quantitative mapping of T2 , T2* , proton density, and susceptibility at 1.1 × 1.1 × 3 mm3 whole-brain in 28 s (0.8 s/slice), and (2) a gradient-echo EPTI, for multi-echo and quantitative T2* fMRI at 2 × 2 × 3 mm3 whole-brain at a 3.3 s temporal resolution. CONCLUSION: EPTI is a new approach for multi-contrast and/or quantitative imaging that can provide fast acquisition of distortion- and blurring-free images at multiple TEs.


Asunto(s)
Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Simulación por Computador , Humanos , Fantasmas de Imagen
13.
Magn Reson Med ; 79(4): 1992-2002, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28771867

RESUMEN

PURPOSE: To develop a new approach to correct for physiological and macroscopic motion in multishot, interleaved echo-planar diffusion imaging. THEORY: This work built on the previous SPIRiT (iterative self-consistent parallel imaging reconstruction) based reconstruction for physiological motion correction in multishot diffusion-weighted imaging to account for macroscopic motion. In-plane rotation, translation correction, data rejection, and weighted combination are integrated in SPIRiT-based reconstruction to correct for ghosting artifacts, blurring, altered b-matrix, and residual artifacts caused by motion. METHODS: Numerical simulations (one data set was obtained from the Human Connectome Project) and in vivo experiments with deliberate bulk motion were performed to demonstrate the effectiveness of the proposed method. Diffusion images and quantitative tensor parameters were calculated to evaluate the correction performance. RESULTS: The proposed method provided images with reduced artifacts and diffusion tensors with improved accuracy in both simulations and in vivo experiments. For in vivo experiments with deliberate motion, the percentage error of fractional anisotropy in the genu of the corpus callosum was significantly reduced from 17.01 ± 12.64 to 5.73 ± 3.77 through motion correction. CONCLUSIONS: The proposed method can effectively correct for physiological and macroscopic motion artifacts in multishot interleaved echo-planar imaging, generate high resolution diffusion images, and improve the accuracy of tensor calculation. Magn Reson Med 79:1992-2002, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Conectoma , Cuerpo Calloso/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Anisotropía , Artefactos , Encéfalo/diagnóstico por imagen , Simulación por Computador , Imagen de Difusión Tensora , Humanos , Interpretación de Imagen Asistida por Computador , Modelos Estadísticos , Movimiento (Física)
14.
Magn Reson Med ; 79(3): 1525-1531, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28608411

RESUMEN

PURPOSE: To develop a novel diffusion imaging reconstruction framework based on iterative self-consistent parallel imaging reconstruction (SPIRiT) for multishot interleaved echo planar imaging (iEPI), with computation acceleration by virtual coil compression. METHODS: As a general approach for autocalibrating parallel imaging, SPIRiT improves the performance of traditional generalized autocalibrating partially parallel acquisitions (GRAPPA) methods in that the formulation with self-consistency is better conditioned, suggesting SPIRiT to be a better candidate in k-space-based reconstruction. In this study, a general SPIRiT framework is adopted to incorporate both coil sensitivity and phase variation information as virtual coils and then is applied to 2D navigated iEPI diffusion imaging. To reduce the reconstruction time when using a large number of coils and shots, a novel shot-coil compression method is proposed for computation acceleration in Cartesian sampling. Simulations and in vivo experiments were conducted to evaluate the performance of the proposed method. RESULTS: Compared with the conventional coil compression, the shot-coil compression achieved higher compression rates with reduced errors. The simulation and in vivo experiments demonstrate that the SPIRiT-based reconstruction outperformed the existing method, realigned GRAPPA, and provided superior images with reduced artifacts. CONCLUSION: The SPIRiT-based reconstruction with virtual coil compression is a reliable method for high-resolution iEPI diffusion imaging. Magn Reson Med 79:1525-1531, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Humanos
15.
Magn Reson Med ; 80(5): 2024-2032, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29569741

RESUMEN

PURPOSE: To study the effects of 2D navigator distortion and noise level on interleaved EPI (iEPI) DWI reconstruction, using either the image- or k-space-based method. METHODS: The 2D navigator acquisition was adjusted by reducing its echo spacing in the readout direction and undersampling in the phase encoding direction. A POCS-based reconstruction using image-space sampling function (IRIS) algorithm (POCSIRIS) was developed to reduce the impact of navigator distortion. POCSIRIS was then compared with the original IRIS algorithm and a SPIRiT-based k-space algorithm, under different navigator distortion and noise levels. RESULTS: Reducing the navigator distortion can improve the reconstruction of iEPI DWI. The proposed POCSIRIS and SPIRiT-based algorithms are more tolerable to different navigator distortion levels, compared to the original IRIS algorithm. SPIRiT may be hindered by low SNR of the navigator. CONCLUSION: Multi-shot iEPI DWI reconstruction can be improved by reducing the 2D navigator distortion. Different reconstruction methods show variable sensitivity to navigator distortion or noise levels. Furthermore, the findings can be valuable in applications such as simultaneous multi-slice accelerated iEPI DWI and multi-slab diffusion imaging.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Encéfalo/diagnóstico por imagen , Humanos
16.
Magn Reson Med ; 80(5): 1891-1906, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29607548

RESUMEN

PURPOSE: To develop an efficient MR technique for ultra-high resolution diffusion MRI (dMRI) in the presence of motion. METHODS: gSlider is an SNR-efficient high-resolution dMRI acquisition technique. However, subject motion is inevitable during a prolonged scan for high spatial resolution, leading to potential image artifacts and blurring. In this study, an integrated technique termed Motion Corrected gSlider (MC-gSlider) is proposed to obtain high-quality, high-resolution dMRI in the presence of large in-plane and through-plane motion. A motion-aware reconstruction with spatially adaptive regularization is developed to optimize the conditioning of the image reconstruction under difficult through-plane motion cases. In addition, an approach for intra-volume motion estimation and correction is proposed to achieve motion correction at high temporal resolution. RESULTS: Theoretical SNR and resolution analysis validated the efficiency of MC-gSlider with regularization, and aided in selection of reconstruction parameters. Simulations and in vivo experiments further demonstrated the ability of MC-gSlider to mitigate motion artifacts and recover detailed brain structures for dMRI at 860 µm isotropic resolution in the presence of motion with various ranges. CONCLUSION: MC-gSlider provides motion-robust, high-resolution dMRI with a temporal motion correction sensitivity of 2 s, allowing for the recovery of fine detailed brain structures in the presence of large subject movements.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Relación Señal-Ruido
17.
bioRxiv ; 2024 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-38328081

RESUMEN

Purpose: To develop EPTI, a multi-shot distortion-free multi-echo imaging technique, into a single-shot acquisition to achieve improved robustness to motion and physiological noise, increased temporal resolution, and high SNR efficiency for dynamic imaging applications. Methods: A new spatiotemporal encoding was developed to achieve single-shot EPTI by enhancing spatiotemporal correlation in k-t space. The proposed single-shot encoding improves reconstruction conditioning and sampling efficiency, with additional optimization under various accelerations to achieve optimized performance. To achieve high SNR efficiency, continuous readout with minimized deadtime was employed that begins immediately after excitation and extends for an SNR-optimized length. Moreover, k-t partial Fourier and simultaneous multi-slice acquisition were integrated to further accelerate the acquisition and achieve high spatial and temporal resolution. Results: We demonstrated that ss-EPTI achieves higher tSNR efficiency than multi-shot EPTI, and provides distortion-free imaging with densely-sampled multi-echo images at resolutions ~1.25-3 mm at 3T and 7T-with high SNR efficiency and with comparable temporal resolutions to ss-EPI. The ability of ss-EPTI to eliminate dynamic distortions common in EPI also further improves temporal stability. For fMRI, ss-EPTI also provides early-TE images (e.g., 2.9ms) to recover signal-intensity and functional-sensitivity dropout in challenging regions. The multi-echo images provide TE-dependent information about functional fluctuations, successfully distinguishing noise-components from BOLD signals and further improving tSNR. For diffusion MRI, ss-EPTI provides high-quality distortion-free diffusion images and multi-echo diffusion metrics. Conclusion: ss-EPTI provides distortion-free imaging with high image quality, rich multi-echo information, and enhanced efficiency within comparable temporal resolution to ss-EPI, offering a robust and efficient acquisition for dynamic imaging.

18.
bioRxiv ; 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38352481

RESUMEN

Purpose: To overcome the major challenges in dMRI acquisition, including low SNR, distortion/blurring, and motion vulnerability. Methods: A novel Romer-EPTI technique is developed to provide distortion-free dMRI with significant SNR gain, high motion-robustness, sharp spatial resolution, and simultaneous multi-TE imaging. It introduces a ROtating-view Motion-robust supEr-Resolution technique (Romer) combined with a distortion/blurring-free EPTI encoding. Romer enhances SNR by a simultaneous multi-thick-slice acquisition with rotating-view encoding, while providing high motion-robustness through a motion-aware super-resolution reconstruction, which also incorporates slice-profile and real-value diffusion, to resolve high-isotropic-resolution volumes. The in-plane encoding is performed using distortion/blurring-free EPTI, which further improves effective spatial resolution and motion robustness by preventing not only T2/T2*-blurring but also additional blurring resulting from combining encoded volumes with inconsistent geometries caused by dynamic distortions. Self-navigation was incorporated to enable efficient phase correction. Additional developments include strategies to address slab-boundary artifacts, achieve minimal TE for SNR gain at 7T, and achieve high robustness to strong phase variations at high b-values. Results: Using Romer-EPTI, we demonstrate distortion-free whole-brain mesoscale in-vivo dMRI at both 3T (500-µm-iso) and 7T (485-µm-iso) for the first time, with high SNR efficiency (e.g., 25×), and high image quality free from distortion and slab-boundary artifacts with minimal blurring. Motion experiments demonstrate Romer-EPTI's high motion-robustness and ability to recover sharp images in the presence of motion. Romer-EPTI also demonstrates significant SNR gain and robustness in high b-value (b=5000s/mm2) and time-dependent dMRI. Conclusion: Romer-EPTI significantly improves SNR, motion-robustness, and image quality, providing a highly efficient acquisition for high-resolution dMRI and microstructure imaging.

19.
Sci Bull (Beijing) ; 68(2): 192-202, 2023 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-36681587

RESUMEN

Inorganic CsPbI3 perovskite is an important photovoltaic material due to its suitable band gap and high chemical stability. However, it is a challenge to grow high-quality CsPbI3 perovskite because the stability of perovskite phase is low and is sensitive to solvent. So far, most of CsPbI3 perovskites in high-performance perovskite solar cells (PSCs) were prepared from N,N-dimethylformamide, a highly toxic solvent, and no successful case has been reported for dimethyl sulfoxide (DMSO), which is environmentally-friendly with considerably higher complexation capability. Herein, we reveal that forming DMSO-based adduct is the main cause for limiting the quality of CsPbI3 perovskite from DMSO-based solutions, which would inhibit the formation of DMAPbI3 (DMA = dimethylammonium, (CH3)2NH2+) intermediate. Then, by introducing a vacuum treatment, DMSO molecules could be efficiently extracted from the adduct to induce the formation of DMAPbI3 intermediate. After annealing, the intermediate is transitioned to the CsPbI3 perovskite with enhanced crystallinity, high orientation, low defect density, and high uniformity. By using the CsPbI3 perovskite as a light absorber, the PSCs based on carbon electrode (C-PSCs) achieve an efficiency of 16.7%, a new record for inorganic C-PSCs.

20.
Sci Total Environ ; 903: 166212, 2023 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-37567279

RESUMEN

Interfacial solar evaporators are widely used to purify water. However, photothermal materials commonly constituting most interfacial solar evaporators remain expensive; additionally, the inherent structure of the evaporators limits their performance. Furthermore, the large amount of waste cotton produced by the textile industry is an environmental threat. To address these issues, we propose an interfacial solar evaporator, H-CA-CS, with a hierarchical porous structure. This evaporator is made entirely of waste cotton and uses carbon microspheres (CMS) and cellulose aerogel (CA) as photothermal and substrate materials, respectively. Additionally, its photothermal layer (CS layer) has large pores and a high porosity, which promote light absorption and timely vapor escape. In contrast, the water transport layer (CA layer) has small pores, providing a robust capillary effect for water transport. Combined with the outstanding light absorption properties of CMS, H-CA-CS exhibited superior overall performance. We found that H-CA-CS has an excellent evaporation rate (1.68 kg m-2 h-1) and an efficiency of 90.6 % under one solar illumination (1 kW m-2), which are superior to those of many waste-based solar evaporators. Moreover, H-CA-CS maintained a mean evaporation rate of 1.61 kg m-2 h-1, ensuring sustainable evaporation performance under long-term scenarios. Additionally, H-CA-CS can be used to purify seawater and various types of wastewater with removal efficiencies exceeding 99 %. In conclusion, this study proposes a method for efficiently using waste cotton to purify water and provides novel ideas for the high-value use of other waste fibers to further mitigate ongoing environmental degradation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA