1.
Artículo en Inglés | MEDLINE | ID: mdl-39331131

RESUMEN

PURPOSE: Pre-treatment [99mTc]TcMAA-based radioembolization treatment planning using multicompartment dosimetry involves the definition of the tumor and normal tissue compartments and calculation of the prescribed absorbed doses. The aim was to compare the real-world utility of anatomic and [99mTc]TcMAA-based segmentation of tumor and normal tissue compartments. MATERIALS AND METHODS: Included patients had HCC treated by glass [90Y]yttrium microspheres, ≥ 1 tumor, ≥ 3 cm diameter and [99mTc]TcMAA SPECT/CT imaging before treatment. Segmentation was performed retrospectively using dedicated dosimetry software: (1) anatomic (diagnostic CT/MRI-based), and (2) [99mTc]TcMAA threshold-based (i.e., using an activity-isocontour threshold). CT/MRI was co-registered with [99mTc]TcMAA SPECT/CT. Logistic regression and Cox regression, respectively, were used to evaluate relationships between total perfused tumor absorbed dose (TAD) and objective response rate (ORR) and overall survival (OS). In a subset-analysis pre- and post-treatment dosimetry were compared using Bland-Altman analysis and Pearson's correlation coefficient. RESULTS: A total of 209 patients were enrolled. Total perfused tumor and normal tissue volumes were larger when using anatomic versus [99mTc]TcMAA threshold segmentation, resulting in lower absorbed doses. mRECIST ORR was higher with increasing total perfused TAD (odds ratio per 100 Gy TAD increase was 1.22 (95% CI: 1.01-1.49; p = 0.044) for anatomic and 1.19 (95% CI: 1.04-1.37; p = 0.012) for [99mTc]TcMAA threshold segmentation. Higher total perfused TAD was associated with improved OS (hazard ratio per 100 Gy TAD increase was 0.826 (95% CI: 0.714-0.954; p = 0.009) and 0.847 (95% CI: 0.765-0.936; p = 0.001) for anatomic and [99mTc]TcMAA threshold segmentation, respectively). For pre- vs. post-treatment dosimetry comparison, the average bias for total perfused TAD was + 11.5 Gy (95% limits of agreement: -227.0 to 250.0) with a strong positive correlation (Pearson's correlation coefficient = 0.80). CONCLUSION: Real-world data support [99mTc]TcMAA imaging to estimate absorbed doses prior to treatment of HCC with glass [90Y]yttrium microspheres. Both anatomic and [99mTc]TcMAA threshold methods were suitable for treatment planning. TRIAL REGISTRATION NUMBER: NCT03295006.

2.
Eur J Nucl Med Mol Imaging ; 51(1): 245-257, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37698645

RESUMEN

PURPOSE: Investigate reproducibility of two segmentation methods for multicompartment dosimetry, including normal tissue absorbed dose (NTAD) and tumour absorbed dose (TAD), in hepatocellular carcinoma patients treated with yttrium-90 (90Y) glass microspheres. METHODS: TARGET was a retrospective investigation in 209 patients with < 10 tumours per lobe and at least one tumour ≥ 3 cm ± portal vein thrombosis. Dosimetry was compared using two distinct segmentation methods: anatomic (CT/MRI-based) and count threshold-based on pre-procedural 99mTc-MAA SPECT. In a round robin substudy in 20 patients with ≤ 5 unilobar tumours, the inter-observer reproducibility of eight reviewers was evaluated by computing reproducibility coefficient (RDC) of volume and absorbed dose for whole liver, whole liver normal tissue, perfused normal tissue, perfused liver, total perfused tumour, and target lesion. Intra-observer reproducibility was based on second assessments in 10 patients ≥ 2 weeks later. RESULTS: 99mTc-MAA segmentation calculated higher absorbed doses compared to anatomic segmentation (n = 209), 43.9% higher for TAD (95% limits of agreement [LoA]: - 49.0%, 306.2%) and 21.3% for NTAD (95% LoA: - 67.6%, 354.0%). For the round robin substudy (n = 20), inter-observer reproducibility was better for anatomic (RDC range: 1.17 to 3.53) than 99mTc-MAA SPECT segmentation (1.29 to 7.00) and similar between anatomic imaging modalities (CT: 1.09 to 3.56; MRI: 1.24 to 3.50). Inter-observer reproducibility was better for larger volumes. Perfused normal tissue volume RDC was 1.95 by anatomic and 3.19 by 99mTc-MAA SPECT, with corresponding absorbed dose RDC 1.46 and 1.75. Total perfused tumour volume RDC was higher, 2.92 for anatomic and 7.0 by 99mTc-MAA SPECT with corresponding absorbed dose RDC of 1.84 and 2.78. Intra-observer variability was lower for perfused NTAD (range: 14.3 to 19.7 Gy) than total perfused TAD (range: 42.8 to 121.4 Gy). CONCLUSION: Anatomic segmentation-based dosimetry, versus 99mTc-MAA segmentation, results in lower absorbed doses with superior reproducibility. Higher volume compartments, such as normal tissue versus tumour, exhibit improved reproducibility. TRIAL REGISTRATION: NCT03295006.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/tratamiento farmacológico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamiento farmacológico , Estudios Retrospectivos , Reproducibilidad de los Resultados , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio/uso terapéutico , Microesferas , Embolización Terapéutica/efectos adversos
3.
J Vasc Interv Radiol ; 34(12): 2224-2232.e3, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37684003

RESUMEN

OBJECTIVES: To identify the most suitable size of imaging-visible embolic agents with balanced safety and efficacy for bariatric arterial embolization (BAE) in a preclinical model. MATERIALS AND METHODS: Twenty-seven pigs were divided into 3 cohorts. In Cohort I, 16 pigs were randomized to receive (n = 4 each) 40-100-µm microspheres in 1 or 2 fundal arteries, 70-340-µm radiopaque microspheres in 2 fundal arteries, or saline. In Cohort II, 3 pigs underwent renal arterial embolization with either custom-made 100-200-µm, 200-250-µm, 200-300-µm, or 300-400-µm radiopaque microspheres or Bead Block 300-500 µm with microsphere distribution assessed histologically. In Cohort III, 8 pigs underwent BAE in 2 fundal arteries with tailored 100-200-µm radiopaque microspheres (n = 5) or saline (n = 3). RESULTS: In Cohort I, no significant differences in weight or ghrelin expression were observed between BAE and control animals. Moderate-to-severe gastric ulcerations were noted in all BAE animals. In Cohort II, renal embolization with 100-200-µm microspheres occluded vessels with a mean diameter of 139 µm ± 31, which is within the lower range of actual diameters of Bead Block 300-500 µm. In Cohort III, BAE with 100-200-µm microspheres resulted in significantly lower weight gain (42.3% ± 5.7% vs 51.6% ± 2.9% at 8 weeks; P = .04), fundal ghrelin cell density (16.1 ± 6.7 vs 23.6 ± 12.6; P = .045), and plasma ghrelin levels (1,709 pg/mL ± 172 vs 4,343 pg/mL ± 1,555; P < .01) compared with controls and superficial gastric ulcers (5/5). CONCLUSIONS: In this preclinical model, tailored 100-200-µm microspheres were shown to be most suitable for BAE in terms of safety and efficacy.


Asunto(s)
Bariatria , Embolización Terapéutica , Animales , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Ghrelina , Microesferas , Estómago/irrigación sanguínea , Porcinos
4.
Eur J Nucl Med Mol Imaging ; 49(10): 3340-3352, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35394152

RESUMEN

PURPOSE: To investigate the relationships between tumor absorbed dose (TAD) or normal tissue absorbed dose (NTAD) and clinical outcomes in hepatocellular carcinoma (HCC) treated with yttrium-90 glass microspheres. METHODS: TARGET was a retrospective investigation in 13 centers across eight countries. Key inclusion criteria: liver-dominant HCC with or without portal vein thrombosis, < 10 tumors per lobe (at least one ≥ 3 cm), Child-Pugh stage A/B7, BCLC stages A-C, and no prior intra-arterial treatment. Multi-compartment pre-treatment dosimetry was performed retrospectively. Primary endpoint was the relationship between ≥ grade 3 hyperbilirubinemia (such that > 15% of patients experienced an event) without disease progression and NTAD. Secondary endpoints included relationships between (1) objective response (OR) and TAD, (2) overall survival (OS) and TAD, and (3) alpha fetoprotein (AFP) and TAD. RESULTS: No relationship was found between NTAD and ≥ grade 3 hyperbilirubinemia, which occurred in 4.8% of the 209 patients. The mRECIST OR rate over all lesions was 61.7%; for the target (largest) lesion, 70.8%. Responders and non-responders had geometric mean total perfused TADs of 225.5 Gy and 188.3 Gy (p = 0.048). Probability of OR was higher with increasing TAD (p = 0.044). Higher TAD was associated with longer OS (HR per 100 Gy increase = 0.83, 95% CI: 0.71-0.95; p = 0.009). Increased TAD was associated with higher probability of AFP response (p = 0.046 for baseline AFP ≥ 200 ng/mL). CONCLUSION: Real-world data confirmed a significant association between TAD and OR, TAD and OS, and TAD and AFP response. No association was found between ≥ grade 3 hyperbilirubinemia and NTAD. TRIAL REGISTRATION NUMBER: NCT03295006.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/radioterapia , Embolización Terapéutica/efectos adversos , Humanos , Hiperbilirrubinemia/tratamiento farmacológico , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/radioterapia , Microesferas , Estudios Retrospectivos , Resultado del Tratamiento , Radioisótopos de Itrio/uso terapéutico , alfa-Fetoproteínas
5.
J Vasc Interv Radiol ; 32(8): 1103-1112.e12, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33839262

RESUMEN

PURPOSE: To investigate the feasibility, safety, and absorbed-dose distribution of prostatic artery radioembolization (RE) in a canine model. MATERIALS AND METHODS: Fourteen male castrated beagles received dihydroandrosterone/estradiol to induce prostatic hyperplasia for the duration of the study. Each dog underwent fluoroscopic prostatic artery catheterization. Yttrium-90 (90Y) microspheres (TheraSphere; Boston Scientific, Marlborough, Massachusetts) were delivered to 1 prostatic hemigland (dose escalation from 60 to 200 Gy), with the contralateral side serving as a control. Assessments for adverse events were performed throughout the follow-up (Common Terminology Criteria for Adverse Events v5.0). Positron emission tomography/magnetic resonance (MR) imaging provided a confirmation after the delivery of absorbed-dose distribution. MR imaging was performed before and 3, 20, and 40 days after RE. Tissue harvest of the prostate, rectum, bladder, urethra, penis, and neurovascular bundles was performed 60 days after RE. RESULTS: All the animals successfully underwent RE. Positron emission tomography/MR imaging demonstrated localization to and good coverage of only the treated hemigland. No adverse events occurred. The MR imaging showed a significant dose-dependent decrease in the treated hemigland size at 40 days (25%-60%, P < .001). No extraprostatic radiographic changes were observed. Necropsy demonstrated no gross rectal, urethral, penile, or bladder changes. Histology revealed RE-induced changes in the treated prostatic tissues of the highest dose group, with gland atrophy and focal necrosis. No extraprostatic RE-related histologic findings were observed. CONCLUSIONS: Prostate 90Y RE is safe and feasible in a canine model and leads to focal dose-dependent changes in the gland without inducing unwanted extraprostatic effects. These results suggest that an investigation of nonoperative prostate cancer is warranted.


Asunto(s)
Braquiterapia , Embolización Terapéutica , Neoplasias de la Próstata , Animales , Perros , Humanos , Masculino , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioisótopos de Itrio
6.
Eur J Nucl Med Mol Imaging ; 47(4): 816-827, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31741021

RESUMEN

PURPOSE: In Y90 radioembolization, the number of microspheres infused varies by more than a factor of 20 over the shelf-life of the glass radioembolization device. We investigated the effect of the number of Y90 microspheres on normal liver tissue. METHOD: Healthy pigs received lobar radioembolization with glass Y90 microspheres at 4, 8, 12, and 16 days post-calibration, representing a > 20× range in the number of microspheres deposited per milliliter in tissue. Animals were survived for 1-month post-treatment and the livers were explanted and scanned on a micro CT system to fully characterize the microscopic distribution of individual microspheres. A complete 3D microdosimetric evaluation of each liver was performed with a spatially correlated analysis of histopathologic effect. RESULTS: Through whole-lobe microscopic identification of each microsphere, a consistent number of microspheres per sphere cluster was found at 4, 8, and 12 days postcalibration, despite an 8-fold increase in total microspheres infused from days 4 to 12. The additional microspheres instead resulted in more clusters formed and, therefore, a more homogeneous microscopic absorbed dose. The increased absorbed-dose homogeneity resulted in a greater volume fraction of the liver receiving a potentially toxic absorbed dose based on radiobiologic models. Histopathologic findings in the animals support a possible increase in normal liver toxicity in later treatments with more spheres (i.e., ≥ day 12) compared to early treatments with less spheres (i.e., ≤ day 8). CONCLUSION: The microdosimetric evidence presented supports a recommendation of caution when treating large volumes (e.g., right lobe) using glass 90Y microspheres at more than 8 days post-calibration, i.e., after "2nd week" Monday. The favorable normal tissue microscopic distribution and associated low toxicity of first week therapies may encourage opportunities for dose escalation with glass microspheres and could also be considered for patients with decreased hepatic reserve.


Asunto(s)
Braquiterapia , Embolización Terapéutica , Neoplasias Hepáticas , Exposición a la Radiación , Animales , Embolización Terapéutica/efectos adversos , Neoplasias Hepáticas/radioterapia , Microesferas , Porcinos , Radioisótopos de Itrio/efectos adversos
7.
Future Oncol ; 14(26): 2741-2760, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29944007

RESUMEN

This review describes the historical development of an imageable spherical embolic agent and focuses on work performed in collaboration between Biocompatibles UK Ltd (a BTG International group company) and the NIH to demonstrate radiopaque bead utility and bring a commercial offering to market that meets a clinical need. Various chemistries have been investigated and multiple prototypes evaluated in search of an optimized product with the right balance of handling and imaging properties. Herein, we describe the steps taken in the development of DC Bead LUMI™, the first commercially available radiopaque drug-eluting bead, ultimately leading to the first human experience of this novel embolic agent in the treatment of liver tumors.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Quimioembolización Terapéutica/métodos , Portadores de Fármacos/química , Desarrollo de Medicamentos , Neoplasias Hepáticas/terapia , Animales , Quimioembolización Terapéutica/instrumentación , Medios de Contraste/química , Modelos Animales de Enfermedad , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Microesferas , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
8.
Int J Hyperthermia ; 34(6): 786-794, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29284329

RESUMEN

PURPOSE: Current release assays have inadequate temporal resolution ( ∼ 10 s) to characterise temperature sensitive liposomes (TSL) designed for intravascular triggered drug release, where release within the first few seconds is relevant for drug delivery. MATERIALS AND METHODS: We developed a novel release assay based on a millifluidic device. A 500 µm capillary tube was heated by a temperature-controlled Peltier element. A TSL solution encapsulating a fluorescent compound was pumped through the tube, producing a fluorescence gradient along the tube due to TSL release. Release kinetics were measured by analysing fluorescence images of the tube. We measured three TSL formulations: traditional TSL (DPPC:DSPC:DSPE-PEF2000,80:15:5), MSPC-LTSL (DPPC:MSPC:DSPE-PEG2000,85:10:5) and MPPC-LTSL (DPPC:MMPC:PEF2000,86:10:4). TSL were loaded with either carboxyfluorescein (CF), Calcein, tetramethylrhodamine (TMR) or doxorubicin (Dox). TSL were diluted in one of the four buffers: phosphate buffered saline (PBS), 10% bovine serum albumin (BSA) solution, foetal bovine serum (FBS) or human plasma. Release was measured between 37-45 °C. RESULTS: The millifluidic device allowed measurement of release kinetics within the first few seconds at ∼5 ms temporal resolution. Dox had the fastest release and highest release %, followed by CF, Calcein and TMR. Of the four buffers, release was fastest in human plasma, followed by FBS, BSA and PBS. CONCLUSIONS: The millifluidic device allows measurement of TSL release at unprecedented temporal resolution, thus allowing adequate characterisation of TSL release at time scales relevant for intravascular triggered drug release. The type of buffer and encapsulated compound significantly affect release kinetics and need to be considered when designing and evaluating novel TSL-drug combinations.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Liberación de Fármacos/efectos de los fármacos , Hipertermia Inducida/métodos , Liposomas/química , Microfluídica/métodos , Humanos , Temperatura
9.
J Vasc Interv Radiol ; 28(2): 260-268.e2, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27641675

RESUMEN

PURPOSE: To investigate material density, flow, and viscosity effects on microsphere distribution within an in vitro model designed to simulate hepatic arteries. MATERIALS AND METHODS: A vascular flow model was used to compare distribution of glass and resin surrogates in a clinically derived flow range (60-120 mL/min). Blood-mimicking fluid (BMF) composed of glycerol and water (20%-50% vol/vol) was used to simulate a range of blood viscosities. Microsphere distribution was quantified gravimetrically, and injectate solution was dyed to enable quantification by UV spectrophotometry. Microsphere injection rate (5-30 mL/min) and the influence of contrast agent dilution of injection solution (0%-60% vol/vol) were also investigated. RESULTS: No significant differences in behavior were observed between the glass and resin surrogate materials under any tested flow conditions (P = .182; n = 144 injections). Microspheres tend to align more consistently with the saline injection solution (r2 = 0.5712; n = 144) compared with total BMF flow distribution (r2 = 0.0104; n = 144). The most predictable injectate distribution (ie, greatest alignment with BMF flow, < 5% variation) was demonstrated with > 10-mL/min injection rates of pure saline solution, although < 20% variation with glass microsphere distribution was observed with injection solution containing as much as 30% contrast medium when injected at > 20 mL/min. CONCLUSIONS: Glass and resin yttrium-90 surrogates demonstrated similar distribution in a range of clinically relevant flow conditions, suggesting that microsphere density does not have a significant influence on microsphere distribution. Injection parameters that enhanced the mixing of the spheres with the BMF resulted in the most predictable distribution.


Asunto(s)
Embolización Terapéutica/métodos , Vidrio/química , Arteria Hepática/fisiopatología , Circulación Hepática , Neoplasias Hepáticas/terapia , Modelos Anatómicos , Modelos Cardiovasculares , Radiofármacos/administración & dosificación , Resinas Sintéticas/química , Radioisótopos de Itrio/administración & dosificación , Velocidad del Flujo Sanguíneo , Viscosidad Sanguínea , Glicerol/química , Arteria Hepática/patología , Humanos , Neoplasias Hepáticas/irrigación sanguínea , Microesferas , Flujo Sanguíneo Regional , Técnicas de Réplica , Agua/química
10.
J Vasc Interv Radiol ; 28(5): 722-730.e1, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28238581

RESUMEN

PURPOSE: To evaluate whether technetium-99 (99mTc)-labeled macroaggregated albumin (MAA) can predict subsequent yttrium-90 (90Y) distribution and imaging response in patients with hepatocellular carcinoma (HCC). MATERIALS: Retrospective review was performed of records of 83 patients with HCC who underwent 90Y glass microsphere radioembolization with 99mTc-MAA single photon emission computed tomography (SPECT) and 90Y positron emission tomography (PET)/CT between January 2013 and December 2014. Images were fused to segment the whole liver normal tissue (WLNT) and the largest tumors. Fused images were reviewed and analyzed for comparison of absorbed dose (AD) to tumors and WLNT as calculated from 99mTc-MAA SPECT and from 90Y PET/CT, subjective imaging comparison of 99mTc-MAA SPECT and 90Y PET for tumors and WLNT, and correlation of tumoral AD with response on follow-up CT. RESULTS: Final analysis included 73 and 63 patients for WLNT and tumor 99mTc-MAA/90Y correlation, respectively, and 62 patients for AD vs response. 99mTc-MAA/90Y limit of agreement for each reviewer was viewed as clinically acceptable only for WLNT (-15 to 15 Gy). AD interreviewer variability was clinically acceptable for WLNT but was too broad for tumor. Mean tumor AD for objective response (78%) was 313 Gy vs 234 Gy for nonresponders. No threshold was found between tumor AD and response (P > .1). Catheter mismatch between 99mTc-MAA and 90Y had a direct impact on AD mismatch between the 2 image sets. CONCLUSIONS: 99mTc-MAA was found to be a poor surrogate to quantitatively predict subsequent 90Y AD to hepatocellular tumors. 99mTc-MAA distribution correlated with 90Y distribution in the normal hepatic parenchyma.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos/farmacocinética , Agregado de Albúmina Marcado con Tecnecio Tc 99m/farmacocinética , Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio/farmacocinética , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Microesferas , Persona de Mediana Edad , Estudios Retrospectivos , Distribución Tisular
11.
Radiology ; 279(3): 741-53, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26678453

RESUMEN

Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-µm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-µm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-µm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. (©) RSNA, 2015.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Animales , Tomografía Computarizada de Haz Cónico , Medios de Contraste , Aceite Etiodizado , Neoplasias Hepáticas Experimentales/irrigación sanguínea , Masculino , Microesferas , Tomografía Computarizada Multidetector , Imagen Multimodal , Conejos
12.
Pharm Res ; 33(10): 2459-69, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27343000

RESUMEN

PURPOSE: Low temperature sensitive liposome (LTSL) encapsulated docetaxel were combined with mild hyperthermia (40-42°C) to investigate in vivo biodistribution and efficacy against a castrate resistant prostate cancer. METHOD: Female athymic nude mice with human prostate PC-3 M-luciferase cells grown subcutaneously into the right hind leg were randomized into six groups: saline (+/- heat), free docetaxel (+/- heat), and LTSL docetaxel (+/- heat). Treatment (15 mg docetaxel/kg) was administered via tail vein once tumors reached a size of 200-300 mm(3). Mice tumor volumes and body weights were recorded for up to 60 days. Docetaxel concentrations of harvested tumor and organ/tissue homogenates were determined by LC-MS. Histological evaluation (Mean vessel density, Ki67 proliferation, Caspase-3 apoptosis) of saline, free Docetaxel and LTSL docetaxel (+/- heat n = 3-5) was performed to determine molecular mechanism responsible for tumor cell killing. RESULT: LTSL/heat resulted in significantly higher tumor docetaxel concentrations (4.7-fold greater compared to free docetaxel). Adding heat to LTSL Docetaxel or free docetaxel treatment resulted in significantly greater survival and growth delay compared to other treatments (p < 0.05). Differences in body weight between all Docetaxel treatments were not reduced by >10% and were not statistically different from each other. Molecular markers such as caspase-3 were upregulated, and Ki67 expression was significantly decreased in the chemo-hyperthermia group. Vessel density was similar post treatment, but the heated group had reduced vessel area, suggesting thermal enhancement in efficacy by reduction in functional perfusion. CONCLUSION: This technique of hyperthermia sensitization and enhanced docetaxel delivery has potential for clinical translation for prostate cancer treatment.


Asunto(s)
Antineoplásicos/metabolismo , Modelos Animales de Enfermedad , Hipertermia Inducida/métodos , Neoplasias de la Próstata/metabolismo , Taxoides/metabolismo , Animales , Antineoplásicos/administración & dosificación , Línea Celular Tumoral , Docetaxel , Sistemas de Liberación de Medicamentos/métodos , Femenino , Humanos , Liposomas , Masculino , Ratones , Ratones Desnudos , Neoplasias de la Próstata/tratamiento farmacológico , Neoplasias de la Próstata/mortalidad , Distribución Aleatoria , Tasa de Supervivencia/tendencias , Taxoides/administración & dosificación , Temperatura , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología , Ensayos Antitumor por Modelo de Xenoinjerto/métodos
13.
J Vasc Interv Radiol ; 27(1): 133-141.e3, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26321051

RESUMEN

PURPOSE: To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. MATERIALS AND METHODS: Rabbit Vx2 liver tumors were embolized with 100-300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3-5 per group; 18 total). RESULTS: Mean microvascular density was 70 vessels/mm(2) ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31(+) structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. CONCLUSIONS: Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas Experimentales/irrigación sanguínea , Neoplasias Hepáticas Experimentales/terapia , Microvasos , Análisis de Varianza , Animales , Microscopía Fluorescente , Conejos
14.
J Vasc Interv Radiol ; 27(1): 117-126.e3, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26549370

RESUMEN

PURPOSE: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo. MATERIALS AND METHODS: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration. In vivo conspicuity was evaluated in a VX2 tumor model. RESULTS: Lipiodol was loaded into lyophilized beads using two glass syringes and a three-way stopcock. Maximum bead attenuation was achieved within 30 minutes. X-ray attenuation of radiopaque beads increased linearly (21-867 HU) with the amount of beads (0.4-12.5 vol%; R(2) = 0.9989). Doxorubicin loading efficiency and total amount eluted were similar to DC Bead (Biocompatibles UK Ltd); however, the elution rate was slower for radiopaque DEBs (P < .05). Doxorubicin concentration linearly correlated with x-ray attenuation of radiopaque DEBs (R(2) = 0. 99). Radiopaque DEBs were seen in tumor feeding arteries after administration by fluoroscopy, computed tomography, and micro-computed tomography, and their location was confirmed by histology. CONCLUSIONS: A simple, rapid method to produce radiopaque DEBs was developed. These radiopaque DEBs provided sufficient conspicuity to be visualized with x-ray imaging techniques.


Asunto(s)
Quimioembolización Terapéutica/instrumentación , Portadores de Fármacos , Neoplasias Hepáticas Experimentales/terapia , Microesferas , Animales , Modelos Animales de Enfermedad , Doxorrubicina/administración & dosificación , Aceite Etiodizado/administración & dosificación , Hígado/diagnóstico por imagen , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Fantasmas de Imagen , Conejos , Microtomografía por Rayos X
15.
J Mater Sci Mater Med ; 27(1): 13, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26676859

RESUMEN

Clinical use of DC Bead™ loaded with doxorubicin (DEBDOX™) or irinotecan (DEBIRI™), for the treatment of primary and secondary tumours of the liver respectively, is showing great promise. Recently there has been a tendency to select smaller bead size ranges to treat tumours in an effort to allow more drug dose to be administered, improve tumoural penetration and resultant drug delivery and tumour coverage. Herein we describe the development and performance characterisation of a new DC Bead size range (DC BeadM1 (TM), 70-150 µm) capable of an increased bead delivery in the distal vasculature, corresponding to greater tumour coverage and drug dose delivered. Both unloaded and drug loaded DC BeadM1 were shown to have a greater density of distal volume of penetration although the ultimate distal level of penetration was the same as that of the 100-300 µm beads in an in vitro penetration model. Elution of doxorubicin was slower than irinotecan elution, but it was similar when comparing the same drug elution from 70 to 150 µm compared to 100-300 µm beads. Radiopaque versions of 70-150 and 100-300 µm beads were prepared in order to evaluate distribution ex vivo using µ-CT and doxorubicin distribution using epifluorescent microscopy. Liver distribution of the radiopaque versions of the beads was shown to be more distal and efficient at filling smaller vessels with the DC BeadM1 and correspondingly more beads were found per vessel histologically with a larger area of drug coverage with the smaller size range. This study indicates that the smaller (70-150 µm) beads should permit an increased dose of drug to be administered to both hypervascular and hypovascular tumours as compared to 100-300 µm beads.


Asunto(s)
Antineoplásicos/administración & dosificación , Camptotecina/análogos & derivados , Catéteres , Doxorrubicina/administración & dosificación , Portadores de Fármacos , Neoplasias Hepáticas Experimentales/tratamiento farmacológico , Animales , Antineoplásicos/farmacocinética , Camptotecina/administración & dosificación , Camptotecina/farmacocinética , Doxorrubicina/farmacocinética , Irinotecán , Conejos , Microtomografía por Rayos X
16.
J Vasc Interv Radiol ; 26(10): 1567-1573, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26231108

RESUMEN

PURPOSE: To evaluate the effect of embolic diameter on achievement of hypoxia after embolization in an animal model of liver tumors. MATERIALS AND METHODS: Inoculation of VX2 tumors in the left liver lobe was performed successfully in 12 New Zealand white rabbits weighing 3.7 kg ± 0.5 (mean ± SD). Tumors were deemed eligible for oxygen measurements when the maximum transverse diameter measured 15 mm or more by ultrasound examination. Direct monitoring of oxygenation of implanted rabbit hepatic VX2 tumors was performed with a fiberoptic electrode during and after transarterial embolization of the proper hepatic artery to angiographic flow stasis with microspheres measuring 70-150 µm, 100-300 µm, or 300-500 µm in diameter. RESULTS: Failure to achieve tumor hypoxia as defined despite angiographic flow stasis was observed in 10 of 11 animals. Embolization microsphere size effect failed to demonstrate a significant trend on hypoxia outcome among the diameters tested, and pair-wise comparisons of different embolic diameter treatment groups showed no difference in hypoxia outcome. All microsphere diameters tested resulted in similar absolute reduction (24.3 mm Hg ± 18.3, 29.1 mm Hg ± 1.8, and 19.9 mm Hg ± 9.3, P = .66) and percentage decrease in oxygen (56.0 mm Hg ± 23.9, 56.0 mm Hg ± 6.4, and 35.8 mm Hg ± 20.6, P = .65). Pair-wise comparisons for percent tumor area occupied by embolic agents showed a significantly reduced fraction for 300-500 µm diameters compared with 70-150 µm diameters (P < .05). CONCLUSIONS: In the rabbit VX2 liver tumor model, three tested microsphere diameters failed to cause tumor hypoxia as measured by a fiberoptic probe sensor according to the adopted hypoxia definitions.


Asunto(s)
Quimioembolización Terapéutica/métodos , Hemostáticos/administración & dosificación , Hemostáticos/química , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/terapia , Oxígeno/metabolismo , Animales , Hipoxia de la Célula , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Femenino , Neoplasias Hepáticas/diagnóstico por imagen , Microesferas , Tamaño de la Partícula , Conejos , Resultado del Tratamiento , Ultrasonografía
17.
Int J Hyperthermia ; 31(1): 67-73, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25766387

RESUMEN

BACKGROUND: Clinical efficacy of thrombolytic drugs is limited by lack of specific delivery and requires large therapeutic doses which increase toxicity. Encapsulating these drugs in temperature-sensitive liposomes and applying hyperthermia to deliver thrombolytic agents locally to thrombus might theoretically favourably alter the therapeutic window. The objectives of this study were to formulate liposomes encapsulating thrombolytics and assess thrombolytic activity following hyperthermia. METHODS: Three liposome formulations were investigated: temperature-sensitive liposome (TSL, DPPC:DSPE-PEG2000 (mol% 95:5)), low temperature-sensitive liposome (LTSL, DPPC:MSPC:DSPE-PEG2000 (mol% 85.3:9.7:5)), and traditional temperature-sensitive liposome (TTSL, DPPC:HSPC:Chol:DSPE-PEG2000 (mol% 55:25:15:5)). To characterise temperature-dependent release of high molecular weight cargo from each formulation, fluorescein-conjugated dextrans (70 kDa) were loaded and release was quantified via spectrophotometry. Staphylokinase (SAK), urokinase, and tissue-type plasminogen activator were also loaded individually into each liposome formulation. Leakage at 37 °C and release at 38-44 °C were quantified via chromogenic enzymatic activity assay. Clot lysis was evaluated by measuring mass of blood clots before and after thrombolytic liposome treatment. RESULTS: The LTSL formulation had optimal release characteristics with maximum release at 41.3 °C. Release of dextrans from LTSLs was observed to be 11.5 ± 1.5%, 79.7 ± 1.6%, and 93.6 ± 3.7% after 15 min in plasma at 37°, 39°, and 41.3 °C, respectively. The SAK LTSL had the highest release/leakage ratio and demonstrated greater clot lysis. CONCLUSIONS: The SAK LTSL achieves significant clot lysis in vitro. When combined with local hyperthermia, the SAK LTSL potentially produces sufficient thrombolysis while minimising systemic side effects.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Fibrinolíticos/administración & dosificación , Metaloendopeptidasas/administración & dosificación , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación , Humanos , Hipertermia Inducida , Lípidos/química , Liposomas , Masculino , Metaloendopeptidasas/química , Polietilenglicoles/química , Temperatura , Activador de Tejido Plasminógeno/química , Activador de Plasminógeno de Tipo Uroquinasa/química
18.
J Mater Sci Mater Med ; 26(6): 198, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26105830

RESUMEN

Therapeutic embolization of blood vessels is a minimally invasive, catheter-based procedure performed with solid or liquid emboli to treat bleeding, vascular malformations, and vascular tumors. Hepatocellular carcinoma (HCC) affects about half a million people per year. When unresectable, HCC is treated with embolization and local drug therapy by transarterial chemoembolization (TACE). For TACE, drug eluting beads (DC Bead(®)) may be used to occlude or reduce arterial blood supply and deliver chemotherapeutics locally to the tumor. Although this treatment has been shown to be safe and to improve patient survival, the procedure lacks imaging feedback regarding the location of embolic agent and drug coverage. To address this shortcoming, herein we report the synthesis and characterization of image-able drug eluting beads (iBeads) from the commercial DC Bead(®) product. Two different radiopaque beads were synthesized. In one approach, embolic beads were conjugated with 2,3,5-triiodobenzyl alcohol in the presence of 1,1'-carbonyldiimidazol to give iBead I. iBead II was synthesized with a similar approach but instead using a trimethylenediamine spacer and 2,3,5-triiodobenzoic acid. Doxorubicin was loaded into the iBeads II using a previously reported method. Size and shape of iBeads were evaluated using an upright microscope and their conspicuity assessed using a clinical CT and micro-CT. Bland and Dox-loaded iBeads II visualized with both clinical CT and microCT. Under microCT, individual bland and Dox loaded beads had a mean attenuation of 7904 ± 804 and 11,873.96 ± 706.12 HU, respectively. These iBeads have the potential to enhance image-guided TACE procedures by providing localization of embolic-particle and drug.


Asunto(s)
Quimioembolización Terapéutica/métodos , Medios de Contraste/química , Medios de Contraste/síntesis química , Antineoplásicos/administración & dosificación , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Diaminas/química , Doxorrubicina/administración & dosificación , Portadores de Fármacos/química , Sistemas de Liberación de Medicamentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Ensayo de Materiales , Microesferas , Fantasmas de Imagen , Alcohol Polivinílico/química , Ácidos Triyodobenzoicos/química , Microtomografía por Rayos X
19.
EJNMMI Phys ; 11(1): 46, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38809320

RESUMEN

BACKGROUND: Personalised multi-compartment dosimetry based on [99mTc]Tc-MAA is a valuable tool for planning 90Y radioembolization treatments. The establishment and effective application of dose-effect relationships in yttrium-90 (90Y) radioembolization requires [99mTc]Tc-MAA SPECT quantification ideally independent of clinical site. The purpose of this multi-centre phantom study was to evaluate inter-site variability of [99mTc]Tc-MAA imaging and evaluate a standardised imaging protocol. Data was obtained from the TARGET study, an international, retrospective multi-centre study including 14 sites across 8 countries. The impact of imaging related factors was estimated using a NEMA IQ phantom (representing the liver), and a uniformly filled cylindrical phantom (representing the lungs). Imaging was performed using site-specific protocols and a standardized protocol. In addition, the impact of implementing key image corrections (scatter and attenuation correction) in the site-specific protocols was investigated. Inter-site dosimetry accuracy was evaluated by comparing computed Lung Shunt Fraction (LSF) measured using planar imaging of the cylindrical and NEMA phantom, and contrast recovery coefficient (CRC) measured using SPECT imaging of the NEMA IQ phantom. RESULTS: Regarding the LSF, inter-site variation with planar site-specific protocols was minimal, as determined by comparing computed LSF between sites (interquartile range 9.6-10.1%). A standardised protocol did not improve variation (interquartile range 8.4-9.0%) but did improve mean accuracy compared to the site-specific protocols (5.0% error for standardised protocol vs 8.8% error for site-specific protocols). Regarding the CRC, inter-system variation was notable for site-specific SPECT protocols and could not be improved by the standardised protocol (CRC interquartile range for 37 mm sphere 0.5-0.7 and 0.6-0.8 respectively), however the standardised protocol did improve accuracy of sphere:background determination. Implementation of key image corrections did improve inter-site variation (CRC interquartile range for 37 mm sphere 0.6-0.7). CONCLUSION: Eliminating sources of variability in image corrections between imaging protocols reduces inter-site variation in quantification. A standardised protocol was not able to improve consistency of LSF or CRC but was able to improve accuracy.

20.
BJU Int ; 112(4): 508-16, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23746198

RESUMEN

OBJECTIVE: To characterise the feasibility and safety of a novel transurethral ultrasound (US)-therapy device combined with real-time multi-plane magnetic resonance imaging (MRI)-based temperature monitoring and temperature feedback control, to enable spatiotemporally precise regional ablation of simulated prostate gland lesions in a preclinical canine model. To correlate ablation volumes measured with intra-procedural cumulative thermal damage estimates, post-procedural MRI, and histopathology. MATERIALS AND METHODS: Three dogs were treated with three targeted ablations each, using a prototype MRI-guided transurethral US-therapy system (Philips Healthcare, Vantaa, Finland). MRI provided images for treatment planning, guidance, real-time multi-planar thermometry, as well as post-treatment evaluation of efficacy. After treatment, specimens underwent histopathological analysis to determine the extent of necrosis and cell viability. Statistical analyses (Pearson's correlation, Student's t-test) were used to evaluate the correlation between ablation volumes measured with intra-procedural cumulative thermal damage estimates, post-procedural MRI, and histopathology. RESULTS: MRI combined with a transurethral US-therapy device enabled multi-planar temperature monitoring at the target as well as in surrounding tissues, allowing for safe, targeted, and controlled ablations of prescribed lesions. Ablated volumes measured by cumulative thermal dose positively correlated with volumes determined by histopathological analysis (r(2) 0.83, P < 0.001). Post-procedural contrast-enhanced and diffusion-weighted MRI showed a positive correlation with non-viable areas on histopathological analysis (r(2) 0.89, P < 0.001, and r(2) 0.91, P = 0.003, respectively). Additionally, there was a positive correlation between ablated volumes according to cumulative thermal dose and volumes identified on post-procedural contrast-enhanced MRI (r(2) 0.77, P < 0.01). There was no difference in mean ablation volumes assessed with the various analysis methods (P > 0.05, Student's t-test). CONCLUSIONS: MRI-guided transurethral US therapy enabled safe and targeted ablations of prescribed lesions in a preclinical canine prostate model. Ablation volumes were reliably predicted by intra- and post-procedural imaging. Clinical studies are needed to confirm the feasibility, safety, oncological control, and functional outcomes of this therapy in patients in whom focal therapy is indicated.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/terapia , Terapia por Ultrasonido/métodos , Animales , Perros , Masculino , Modelos Anatómicos , Uretra
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA