1.
J Vasc Interv Radiol ; 32(8): 1103-1112.e12, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33839262

RESUMEN

PURPOSE: To investigate the feasibility, safety, and absorbed-dose distribution of prostatic artery radioembolization (RE) in a canine model. MATERIALS AND METHODS: Fourteen male castrated beagles received dihydroandrosterone/estradiol to induce prostatic hyperplasia for the duration of the study. Each dog underwent fluoroscopic prostatic artery catheterization. Yttrium-90 (90Y) microspheres (TheraSphere; Boston Scientific, Marlborough, Massachusetts) were delivered to 1 prostatic hemigland (dose escalation from 60 to 200 Gy), with the contralateral side serving as a control. Assessments for adverse events were performed throughout the follow-up (Common Terminology Criteria for Adverse Events v5.0). Positron emission tomography/magnetic resonance (MR) imaging provided a confirmation after the delivery of absorbed-dose distribution. MR imaging was performed before and 3, 20, and 40 days after RE. Tissue harvest of the prostate, rectum, bladder, urethra, penis, and neurovascular bundles was performed 60 days after RE. RESULTS: All the animals successfully underwent RE. Positron emission tomography/MR imaging demonstrated localization to and good coverage of only the treated hemigland. No adverse events occurred. The MR imaging showed a significant dose-dependent decrease in the treated hemigland size at 40 days (25%-60%, P < .001). No extraprostatic radiographic changes were observed. Necropsy demonstrated no gross rectal, urethral, penile, or bladder changes. Histology revealed RE-induced changes in the treated prostatic tissues of the highest dose group, with gland atrophy and focal necrosis. No extraprostatic RE-related histologic findings were observed. CONCLUSIONS: Prostate 90Y RE is safe and feasible in a canine model and leads to focal dose-dependent changes in the gland without inducing unwanted extraprostatic effects. These results suggest that an investigation of nonoperative prostate cancer is warranted.


Asunto(s)
Braquiterapia , Embolización Terapéutica , Neoplasias de la Próstata , Animales , Perros , Humanos , Masculino , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioisótopos de Itrio
2.
Eur J Nucl Med Mol Imaging ; 47(4): 816-827, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31741021

RESUMEN

PURPOSE: In Y90 radioembolization, the number of microspheres infused varies by more than a factor of 20 over the shelf-life of the glass radioembolization device. We investigated the effect of the number of Y90 microspheres on normal liver tissue. METHOD: Healthy pigs received lobar radioembolization with glass Y90 microspheres at 4, 8, 12, and 16 days post-calibration, representing a > 20× range in the number of microspheres deposited per milliliter in tissue. Animals were survived for 1-month post-treatment and the livers were explanted and scanned on a micro CT system to fully characterize the microscopic distribution of individual microspheres. A complete 3D microdosimetric evaluation of each liver was performed with a spatially correlated analysis of histopathologic effect. RESULTS: Through whole-lobe microscopic identification of each microsphere, a consistent number of microspheres per sphere cluster was found at 4, 8, and 12 days postcalibration, despite an 8-fold increase in total microspheres infused from days 4 to 12. The additional microspheres instead resulted in more clusters formed and, therefore, a more homogeneous microscopic absorbed dose. The increased absorbed-dose homogeneity resulted in a greater volume fraction of the liver receiving a potentially toxic absorbed dose based on radiobiologic models. Histopathologic findings in the animals support a possible increase in normal liver toxicity in later treatments with more spheres (i.e., ≥ day 12) compared to early treatments with less spheres (i.e., ≤ day 8). CONCLUSION: The microdosimetric evidence presented supports a recommendation of caution when treating large volumes (e.g., right lobe) using glass 90Y microspheres at more than 8 days post-calibration, i.e., after "2nd week" Monday. The favorable normal tissue microscopic distribution and associated low toxicity of first week therapies may encourage opportunities for dose escalation with glass microspheres and could also be considered for patients with decreased hepatic reserve.


Asunto(s)
Braquiterapia , Embolización Terapéutica , Neoplasias Hepáticas , Exposición a la Radiación , Animales , Embolización Terapéutica/efectos adversos , Neoplasias Hepáticas/radioterapia , Microesferas , Porcinos , Radioisótopos de Itrio/efectos adversos
3.
Future Oncol ; 14(26): 2741-2760, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29944007

RESUMEN

This review describes the historical development of an imageable spherical embolic agent and focuses on work performed in collaboration between Biocompatibles UK Ltd (a BTG International group company) and the NIH to demonstrate radiopaque bead utility and bring a commercial offering to market that meets a clinical need. Various chemistries have been investigated and multiple prototypes evaluated in search of an optimized product with the right balance of handling and imaging properties. Herein, we describe the steps taken in the development of DC Bead LUMI™, the first commercially available radiopaque drug-eluting bead, ultimately leading to the first human experience of this novel embolic agent in the treatment of liver tumors.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Quimioembolización Terapéutica/métodos , Portadores de Fármacos/química , Desarrollo de Medicamentos , Neoplasias Hepáticas/terapia , Animales , Quimioembolización Terapéutica/instrumentación , Medios de Contraste/química , Modelos Animales de Enfermedad , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Microesferas , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
4.
Int J Hyperthermia ; 34(6): 786-794, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29284329

RESUMEN

PURPOSE: Current release assays have inadequate temporal resolution ( ∼ 10 s) to characterise temperature sensitive liposomes (TSL) designed for intravascular triggered drug release, where release within the first few seconds is relevant for drug delivery. MATERIALS AND METHODS: We developed a novel release assay based on a millifluidic device. A 500 µm capillary tube was heated by a temperature-controlled Peltier element. A TSL solution encapsulating a fluorescent compound was pumped through the tube, producing a fluorescence gradient along the tube due to TSL release. Release kinetics were measured by analysing fluorescence images of the tube. We measured three TSL formulations: traditional TSL (DPPC:DSPC:DSPE-PEF2000,80:15:5), MSPC-LTSL (DPPC:MSPC:DSPE-PEG2000,85:10:5) and MPPC-LTSL (DPPC:MMPC:PEF2000,86:10:4). TSL were loaded with either carboxyfluorescein (CF), Calcein, tetramethylrhodamine (TMR) or doxorubicin (Dox). TSL were diluted in one of the four buffers: phosphate buffered saline (PBS), 10% bovine serum albumin (BSA) solution, foetal bovine serum (FBS) or human plasma. Release was measured between 37-45 °C. RESULTS: The millifluidic device allowed measurement of release kinetics within the first few seconds at ∼5 ms temporal resolution. Dox had the fastest release and highest release %, followed by CF, Calcein and TMR. Of the four buffers, release was fastest in human plasma, followed by FBS, BSA and PBS. CONCLUSIONS: The millifluidic device allows measurement of TSL release at unprecedented temporal resolution, thus allowing adequate characterisation of TSL release at time scales relevant for intravascular triggered drug release. The type of buffer and encapsulated compound significantly affect release kinetics and need to be considered when designing and evaluating novel TSL-drug combinations.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Liberación de Fármacos/efectos de los fármacos , Hipertermia Inducida/métodos , Liposomas/química , Microfluídica/métodos , Humanos , Temperatura
5.
J Vasc Interv Radiol ; 28(5): 722-730.e1, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28238581

RESUMEN

PURPOSE: To evaluate whether technetium-99 (99mTc)-labeled macroaggregated albumin (MAA) can predict subsequent yttrium-90 (90Y) distribution and imaging response in patients with hepatocellular carcinoma (HCC). MATERIALS: Retrospective review was performed of records of 83 patients with HCC who underwent 90Y glass microsphere radioembolization with 99mTc-MAA single photon emission computed tomography (SPECT) and 90Y positron emission tomography (PET)/CT between January 2013 and December 2014. Images were fused to segment the whole liver normal tissue (WLNT) and the largest tumors. Fused images were reviewed and analyzed for comparison of absorbed dose (AD) to tumors and WLNT as calculated from 99mTc-MAA SPECT and from 90Y PET/CT, subjective imaging comparison of 99mTc-MAA SPECT and 90Y PET for tumors and WLNT, and correlation of tumoral AD with response on follow-up CT. RESULTS: Final analysis included 73 and 63 patients for WLNT and tumor 99mTc-MAA/90Y correlation, respectively, and 62 patients for AD vs response. 99mTc-MAA/90Y limit of agreement for each reviewer was viewed as clinically acceptable only for WLNT (-15 to 15 Gy). AD interreviewer variability was clinically acceptable for WLNT but was too broad for tumor. Mean tumor AD for objective response (78%) was 313 Gy vs 234 Gy for nonresponders. No threshold was found between tumor AD and response (P > .1). Catheter mismatch between 99mTc-MAA and 90Y had a direct impact on AD mismatch between the 2 image sets. CONCLUSIONS: 99mTc-MAA was found to be a poor surrogate to quantitatively predict subsequent 90Y AD to hepatocellular tumors. 99mTc-MAA distribution correlated with 90Y distribution in the normal hepatic parenchyma.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos/farmacocinética , Agregado de Albúmina Marcado con Tecnecio Tc 99m/farmacocinética , Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Itrio/farmacocinética , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Microesferas , Persona de Mediana Edad , Estudios Retrospectivos , Distribución Tisular
6.
J Vasc Interv Radiol ; 28(2): 260-268.e2, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27641675

RESUMEN

PURPOSE: To investigate material density, flow, and viscosity effects on microsphere distribution within an in vitro model designed to simulate hepatic arteries. MATERIALS AND METHODS: A vascular flow model was used to compare distribution of glass and resin surrogates in a clinically derived flow range (60-120 mL/min). Blood-mimicking fluid (BMF) composed of glycerol and water (20%-50% vol/vol) was used to simulate a range of blood viscosities. Microsphere distribution was quantified gravimetrically, and injectate solution was dyed to enable quantification by UV spectrophotometry. Microsphere injection rate (5-30 mL/min) and the influence of contrast agent dilution of injection solution (0%-60% vol/vol) were also investigated. RESULTS: No significant differences in behavior were observed between the glass and resin surrogate materials under any tested flow conditions (P = .182; n = 144 injections). Microspheres tend to align more consistently with the saline injection solution (r2 = 0.5712; n = 144) compared with total BMF flow distribution (r2 = 0.0104; n = 144). The most predictable injectate distribution (ie, greatest alignment with BMF flow, < 5% variation) was demonstrated with > 10-mL/min injection rates of pure saline solution, although < 20% variation with glass microsphere distribution was observed with injection solution containing as much as 30% contrast medium when injected at > 20 mL/min. CONCLUSIONS: Glass and resin yttrium-90 surrogates demonstrated similar distribution in a range of clinically relevant flow conditions, suggesting that microsphere density does not have a significant influence on microsphere distribution. Injection parameters that enhanced the mixing of the spheres with the BMF resulted in the most predictable distribution.


Asunto(s)
Embolización Terapéutica/métodos , Vidrio/química , Arteria Hepática/fisiopatología , Circulación Hepática , Neoplasias Hepáticas/terapia , Modelos Anatómicos , Modelos Cardiovasculares , Radiofármacos/administración & dosificación , Resinas Sintéticas/química , Radioisótopos de Itrio/administración & dosificación , Velocidad del Flujo Sanguíneo , Viscosidad Sanguínea , Glicerol/química , Arteria Hepática/patología , Humanos , Neoplasias Hepáticas/irrigación sanguínea , Microesferas , Flujo Sanguíneo Regional , Técnicas de Réplica , Agua/química
7.
Radiology ; 279(3): 741-53, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26678453

RESUMEN

Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-µm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-µm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-µm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. (©) RSNA, 2015.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Animales , Tomografía Computarizada de Haz Cónico , Medios de Contraste , Aceite Etiodizado , Neoplasias Hepáticas Experimentales/irrigación sanguínea , Masculino , Microesferas , Tomografía Computarizada Multidetector , Imagen Multimodal , Conejos
8.
Pharm Res ; 33(10): 2459-69, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27343000

RESUMEN

PURPOSE: Low temperature sensitive liposome (LTSL) encapsulated docetaxel were combined with mild hyperthermia (40-42°C) to investigate in vivo biodistribution and efficacy against a castrate resistant prostate cancer. METHOD: Female athymic nude mice with human prostate PC-3 M-luciferase cells grown subcutaneously into the right hind leg were randomized into six groups: saline (+/- heat), free docetaxel (+/- heat), and LTSL docetaxel (+/- heat). Treatment (15 mg docetaxel/kg) was administered via tail vein once tumors reached a size of 200-300 mm(3). Mice tumor volumes and body weights were recorded for up to 60 days. Docetaxel concentrations of harvested tumor and organ/tissue homogenates were determined by LC-MS. Histological evaluation (Mean vessel density, Ki67 proliferation, Caspase-3 apoptosis) of saline, free Docetaxel and LTSL docetaxel (+/- heat n = 3-5) was performed to determine molecular mechanism responsible for tumor cell killing. RESULT: LTSL/heat resulted in significantly higher tumor docetaxel concentrations (4.7-fold greater compared to free docetaxel). Adding heat to LTSL Docetaxel or free docetaxel treatment resulted in significantly greater survival and growth delay compared to other treatments (p < 0.05). Differences in body weight between all Docetaxel treatments were not reduced by >10% and were not statistically different from each other. Molecular markers such as caspase-3 were upregulated, and Ki67 expression was significantly decreased in the chemo-hyperthermia group. Vessel density was similar post treatment, but the heated group had reduced vessel area, suggesting thermal enhancement in efficacy by reduction in functional perfusion. CONCLUSION: This technique of hyperthermia sensitization and enhanced docetaxel delivery has potential for clinical translation for prostate cancer treatment.


Asunto(s)
Antineoplásicos/metabolismo , Modelos Animales de Enfermedad , Hipertermia Inducida/métodos , Neoplasias de la Próstata/metabolismo , Taxoides/metabolismo , Animales , Antineoplásicos/administración & dosificación , Línea Celular Tumoral , Docetaxel , Sistemas de Liberación de Medicamentos/métodos , Femenino , Humanos , Liposomas , Masculino , Ratones , Ratones Desnudos , Neoplasias de la Próstata/tratamiento farmacológico , Neoplasias de la Próstata/mortalidad , Distribución Aleatoria , Tasa de Supervivencia/tendencias , Taxoides/administración & dosificación , Temperatura , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología , Ensayos Antitumor por Modelo de Xenoinjerto/métodos
9.
J Vasc Interv Radiol ; 27(1): 133-141.e3, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26321051

RESUMEN

PURPOSE: To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints. MATERIALS AND METHODS: Rabbit Vx2 liver tumors were embolized with 100-300-µm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint. Tumor microvasculature was labeled with an anti-CD31 antibody and analyzed with fluorescence microscopy for perfusion marker overlap/mismatch. Data were analyzed by analysis of variance and post hoc test (n = 3-5 per group; 18 total). RESULTS: Mean microvascular density was 70 vessels/mm(2) ± 17 (standard error of the mean), and 81% ± 1 of microvasculature (ie, CD31(+) structures) was functionally perfused within viable Vx2 tumor regions. Embolization to the extent of substasis eliminated perfusion in 37% ± 9 of perfused microvessels (P > .05 vs baseline), whereas embolization to the extent of angiographic stasis eliminated perfusion in 56% ± 8 of perfused microvessels. Persistent microvascular perfusion following embolization was predominantly found in the tumor periphery, adjacent to normal tissue. Newly perfused microvasculature was evident following embolization to substasis but not when embolization was performed to complete angiographic stasis. CONCLUSIONS: Nearly half of tumor microvasculature remained patent despite embolization to complete angiographic stasis. The observed preservation of tumor microvasculature perfusion with angiographic endpoints of substasis and stasis may have implications for tumor response to embolotherapy.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas Experimentales/irrigación sanguínea , Neoplasias Hepáticas Experimentales/terapia , Microvasos , Análisis de Varianza , Animales , Microscopía Fluorescente , Conejos
10.
J Vasc Interv Radiol ; 27(1): 117-126.e3, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26549370

RESUMEN

PURPOSE: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo. MATERIALS AND METHODS: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration. In vivo conspicuity was evaluated in a VX2 tumor model. RESULTS: Lipiodol was loaded into lyophilized beads using two glass syringes and a three-way stopcock. Maximum bead attenuation was achieved within 30 minutes. X-ray attenuation of radiopaque beads increased linearly (21-867 HU) with the amount of beads (0.4-12.5 vol%; R(2) = 0.9989). Doxorubicin loading efficiency and total amount eluted were similar to DC Bead (Biocompatibles UK Ltd); however, the elution rate was slower for radiopaque DEBs (P < .05). Doxorubicin concentration linearly correlated with x-ray attenuation of radiopaque DEBs (R(2) = 0. 99). Radiopaque DEBs were seen in tumor feeding arteries after administration by fluoroscopy, computed tomography, and micro-computed tomography, and their location was confirmed by histology. CONCLUSIONS: A simple, rapid method to produce radiopaque DEBs was developed. These radiopaque DEBs provided sufficient conspicuity to be visualized with x-ray imaging techniques.


Asunto(s)
Quimioembolización Terapéutica/instrumentación , Portadores de Fármacos , Neoplasias Hepáticas Experimentales/terapia , Microesferas , Animales , Modelos Animales de Enfermedad , Doxorrubicina/administración & dosificación , Aceite Etiodizado/administración & dosificación , Hígado/diagnóstico por imagen , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Fantasmas de Imagen , Conejos , Microtomografía por Rayos X
11.
J Mater Sci Mater Med ; 27(1): 13, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26676859

RESUMEN

Clinical use of DC Bead™ loaded with doxorubicin (DEBDOX™) or irinotecan (DEBIRI™), for the treatment of primary and secondary tumours of the liver respectively, is showing great promise. Recently there has been a tendency to select smaller bead size ranges to treat tumours in an effort to allow more drug dose to be administered, improve tumoural penetration and resultant drug delivery and tumour coverage. Herein we describe the development and performance characterisation of a new DC Bead size range (DC BeadM1 (TM), 70-150 µm) capable of an increased bead delivery in the distal vasculature, corresponding to greater tumour coverage and drug dose delivered. Both unloaded and drug loaded DC BeadM1 were shown to have a greater density of distal volume of penetration although the ultimate distal level of penetration was the same as that of the 100-300 µm beads in an in vitro penetration model. Elution of doxorubicin was slower than irinotecan elution, but it was similar when comparing the same drug elution from 70 to 150 µm compared to 100-300 µm beads. Radiopaque versions of 70-150 and 100-300 µm beads were prepared in order to evaluate distribution ex vivo using µ-CT and doxorubicin distribution using epifluorescent microscopy. Liver distribution of the radiopaque versions of the beads was shown to be more distal and efficient at filling smaller vessels with the DC BeadM1 and correspondingly more beads were found per vessel histologically with a larger area of drug coverage with the smaller size range. This study indicates that the smaller (70-150 µm) beads should permit an increased dose of drug to be administered to both hypervascular and hypovascular tumours as compared to 100-300 µm beads.


Asunto(s)
Antineoplásicos/administración & dosificación , Camptotecina/análogos & derivados , Catéteres , Doxorrubicina/administración & dosificación , Portadores de Fármacos , Neoplasias Hepáticas Experimentales/tratamiento farmacológico , Animales , Antineoplásicos/farmacocinética , Camptotecina/administración & dosificación , Camptotecina/farmacocinética , Doxorrubicina/farmacocinética , Irinotecán , Conejos , Microtomografía por Rayos X
12.
J Vasc Interv Radiol ; 26(10): 1567-1573, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26231108

RESUMEN

PURPOSE: To evaluate the effect of embolic diameter on achievement of hypoxia after embolization in an animal model of liver tumors. MATERIALS AND METHODS: Inoculation of VX2 tumors in the left liver lobe was performed successfully in 12 New Zealand white rabbits weighing 3.7 kg ± 0.5 (mean ± SD). Tumors were deemed eligible for oxygen measurements when the maximum transverse diameter measured 15 mm or more by ultrasound examination. Direct monitoring of oxygenation of implanted rabbit hepatic VX2 tumors was performed with a fiberoptic electrode during and after transarterial embolization of the proper hepatic artery to angiographic flow stasis with microspheres measuring 70-150 µm, 100-300 µm, or 300-500 µm in diameter. RESULTS: Failure to achieve tumor hypoxia as defined despite angiographic flow stasis was observed in 10 of 11 animals. Embolization microsphere size effect failed to demonstrate a significant trend on hypoxia outcome among the diameters tested, and pair-wise comparisons of different embolic diameter treatment groups showed no difference in hypoxia outcome. All microsphere diameters tested resulted in similar absolute reduction (24.3 mm Hg ± 18.3, 29.1 mm Hg ± 1.8, and 19.9 mm Hg ± 9.3, P = .66) and percentage decrease in oxygen (56.0 mm Hg ± 23.9, 56.0 mm Hg ± 6.4, and 35.8 mm Hg ± 20.6, P = .65). Pair-wise comparisons for percent tumor area occupied by embolic agents showed a significantly reduced fraction for 300-500 µm diameters compared with 70-150 µm diameters (P < .05). CONCLUSIONS: In the rabbit VX2 liver tumor model, three tested microsphere diameters failed to cause tumor hypoxia as measured by a fiberoptic probe sensor according to the adopted hypoxia definitions.


Asunto(s)
Quimioembolización Terapéutica/métodos , Hemostáticos/administración & dosificación , Hemostáticos/química , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/terapia , Oxígeno/metabolismo , Animales , Hipoxia de la Célula , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Femenino , Neoplasias Hepáticas/diagnóstico por imagen , Microesferas , Tamaño de la Partícula , Conejos , Resultado del Tratamiento , Ultrasonografía
13.
Int J Hyperthermia ; 31(1): 67-73, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25766387

RESUMEN

BACKGROUND: Clinical efficacy of thrombolytic drugs is limited by lack of specific delivery and requires large therapeutic doses which increase toxicity. Encapsulating these drugs in temperature-sensitive liposomes and applying hyperthermia to deliver thrombolytic agents locally to thrombus might theoretically favourably alter the therapeutic window. The objectives of this study were to formulate liposomes encapsulating thrombolytics and assess thrombolytic activity following hyperthermia. METHODS: Three liposome formulations were investigated: temperature-sensitive liposome (TSL, DPPC:DSPE-PEG2000 (mol% 95:5)), low temperature-sensitive liposome (LTSL, DPPC:MSPC:DSPE-PEG2000 (mol% 85.3:9.7:5)), and traditional temperature-sensitive liposome (TTSL, DPPC:HSPC:Chol:DSPE-PEG2000 (mol% 55:25:15:5)). To characterise temperature-dependent release of high molecular weight cargo from each formulation, fluorescein-conjugated dextrans (70 kDa) were loaded and release was quantified via spectrophotometry. Staphylokinase (SAK), urokinase, and tissue-type plasminogen activator were also loaded individually into each liposome formulation. Leakage at 37 °C and release at 38-44 °C were quantified via chromogenic enzymatic activity assay. Clot lysis was evaluated by measuring mass of blood clots before and after thrombolytic liposome treatment. RESULTS: The LTSL formulation had optimal release characteristics with maximum release at 41.3 °C. Release of dextrans from LTSLs was observed to be 11.5 ± 1.5%, 79.7 ± 1.6%, and 93.6 ± 3.7% after 15 min in plasma at 37°, 39°, and 41.3 °C, respectively. The SAK LTSL had the highest release/leakage ratio and demonstrated greater clot lysis. CONCLUSIONS: The SAK LTSL achieves significant clot lysis in vitro. When combined with local hyperthermia, the SAK LTSL potentially produces sufficient thrombolysis while minimising systemic side effects.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Fibrinolíticos/administración & dosificación , Metaloendopeptidasas/administración & dosificación , Activador de Tejido Plasminógeno/administración & dosificación , Activador de Plasminógeno de Tipo Uroquinasa/administración & dosificación , Humanos , Hipertermia Inducida , Lípidos/química , Liposomas , Masculino , Metaloendopeptidasas/química , Polietilenglicoles/química , Temperatura , Activador de Tejido Plasminógeno/química , Activador de Plasminógeno de Tipo Uroquinasa/química
14.
J Mater Sci Mater Med ; 26(6): 198, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26105830

RESUMEN

Therapeutic embolization of blood vessels is a minimally invasive, catheter-based procedure performed with solid or liquid emboli to treat bleeding, vascular malformations, and vascular tumors. Hepatocellular carcinoma (HCC) affects about half a million people per year. When unresectable, HCC is treated with embolization and local drug therapy by transarterial chemoembolization (TACE). For TACE, drug eluting beads (DC Bead(®)) may be used to occlude or reduce arterial blood supply and deliver chemotherapeutics locally to the tumor. Although this treatment has been shown to be safe and to improve patient survival, the procedure lacks imaging feedback regarding the location of embolic agent and drug coverage. To address this shortcoming, herein we report the synthesis and characterization of image-able drug eluting beads (iBeads) from the commercial DC Bead(®) product. Two different radiopaque beads were synthesized. In one approach, embolic beads were conjugated with 2,3,5-triiodobenzyl alcohol in the presence of 1,1'-carbonyldiimidazol to give iBead I. iBead II was synthesized with a similar approach but instead using a trimethylenediamine spacer and 2,3,5-triiodobenzoic acid. Doxorubicin was loaded into the iBeads II using a previously reported method. Size and shape of iBeads were evaluated using an upright microscope and their conspicuity assessed using a clinical CT and micro-CT. Bland and Dox-loaded iBeads II visualized with both clinical CT and microCT. Under microCT, individual bland and Dox loaded beads had a mean attenuation of 7904 ± 804 and 11,873.96 ± 706.12 HU, respectively. These iBeads have the potential to enhance image-guided TACE procedures by providing localization of embolic-particle and drug.


Asunto(s)
Quimioembolización Terapéutica/métodos , Medios de Contraste/química , Medios de Contraste/síntesis química , Antineoplásicos/administración & dosificación , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Diaminas/química , Doxorrubicina/administración & dosificación , Portadores de Fármacos/química , Sistemas de Liberación de Medicamentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Ensayo de Materiales , Microesferas , Fantasmas de Imagen , Alcohol Polivinílico/química , Ácidos Triyodobenzoicos/química , Microtomografía por Rayos X
15.
BJU Int ; 112(4): 508-16, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23746198

RESUMEN

OBJECTIVE: To characterise the feasibility and safety of a novel transurethral ultrasound (US)-therapy device combined with real-time multi-plane magnetic resonance imaging (MRI)-based temperature monitoring and temperature feedback control, to enable spatiotemporally precise regional ablation of simulated prostate gland lesions in a preclinical canine model. To correlate ablation volumes measured with intra-procedural cumulative thermal damage estimates, post-procedural MRI, and histopathology. MATERIALS AND METHODS: Three dogs were treated with three targeted ablations each, using a prototype MRI-guided transurethral US-therapy system (Philips Healthcare, Vantaa, Finland). MRI provided images for treatment planning, guidance, real-time multi-planar thermometry, as well as post-treatment evaluation of efficacy. After treatment, specimens underwent histopathological analysis to determine the extent of necrosis and cell viability. Statistical analyses (Pearson's correlation, Student's t-test) were used to evaluate the correlation between ablation volumes measured with intra-procedural cumulative thermal damage estimates, post-procedural MRI, and histopathology. RESULTS: MRI combined with a transurethral US-therapy device enabled multi-planar temperature monitoring at the target as well as in surrounding tissues, allowing for safe, targeted, and controlled ablations of prescribed lesions. Ablated volumes measured by cumulative thermal dose positively correlated with volumes determined by histopathological analysis (r(2) 0.83, P < 0.001). Post-procedural contrast-enhanced and diffusion-weighted MRI showed a positive correlation with non-viable areas on histopathological analysis (r(2) 0.89, P < 0.001, and r(2) 0.91, P = 0.003, respectively). Additionally, there was a positive correlation between ablated volumes according to cumulative thermal dose and volumes identified on post-procedural contrast-enhanced MRI (r(2) 0.77, P < 0.01). There was no difference in mean ablation volumes assessed with the various analysis methods (P > 0.05, Student's t-test). CONCLUSIONS: MRI-guided transurethral US therapy enabled safe and targeted ablations of prescribed lesions in a preclinical canine prostate model. Ablation volumes were reliably predicted by intra- and post-procedural imaging. Clinical studies are needed to confirm the feasibility, safety, oncological control, and functional outcomes of this therapy in patients in whom focal therapy is indicated.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/terapia , Terapia por Ultrasonido/métodos , Animales , Perros , Masculino , Modelos Anatómicos , Uretra
16.
Cancer Cell ; 8(2): 99-110, 2005 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16098463

RESUMEN

We have previously shown that radiation increases HIF-1 activity in tumors, causing significant radioprotection of the tumor vasculature. The impact that HIF-1 activation has on overall tumor radiosensitivity, however, is unknown. We reveal here that HIF-1 plays an important role in determining tumor radioresponsiveness through regulating four distinct processes. By promoting ATP metabolism, proliferation, and p53 activation, HIF-1 has a radiosensitizing effect on tumors. Through stimulating endothelial cell survival, HIF-1 promotes tumor radioresistance. As a result, the net effect of HIF-1 blockade on tumor radioresponsiveness is highly dependent on treatment sequencing, with "radiation first" strategies being significantly more effective than the alternative. These data provide a strong rationale for pursuing sequence-specific combinations of HIF-1 blockade and conventional therapeutics.


Asunto(s)
Proteínas de Unión al ADN/antagonistas & inhibidores , Neoplasias/radioterapia , Proteínas Nucleares/antagonistas & inhibidores , Tolerancia a Radiación , Factores de Transcripción/antagonistas & inhibidores , Adenosina Trifosfato/metabolismo , Animales , Apoptosis , Proliferación Celular , Proteínas de Unión al ADN/genética , Proteínas de Unión al ADN/metabolismo , Endotelio Vascular/metabolismo , Endotelio Vascular/efectos de la radiación , Metabolismo Energético , Humanos , Factor 1 Inducible por Hipoxia , Subunidad alfa del Factor 1 Inducible por Hipoxia , Ratones , Neoplasias/metabolismo , Neovascularización Patológica/metabolismo , Proteínas Nucleares/genética , Proteínas Nucleares/metabolismo , Interferencia de ARN , Tolerancia a Radiación/genética , Factores de Transcripción/genética , Factores de Transcripción/metabolismo , Proteína p53 Supresora de Tumor/metabolismo
17.
Int J Hyperthermia ; 29(4): 318-23, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23738699

RESUMEN

PURPOSE: Image-guided ablative therapies use temperatures greater than 45 °C to kill abnormal cells. There is limited published data of cell survival after ablative temperature exposures, which is of importance to predict ablation zone dimensions. The objective of this study was to determine and mathematically model survival of hepatocellular carcinoma cells following ablative temperature exposures (45-60 °C). MATERIALS AND METHODS: Hepatocellular carcinoma (HCC) cell lines were plated in 96-well plates, and heated between 45 and 60 °C for 0-32 min. Heating was applied by a rapid media exchange with heated Hank's balanced salt solution (HBSS) in a temperature-controlled water bath. Cell viability was determined by MTS assay. Survival data was modelled by the Arrhenius model, and the thermal isoeffective dose (TID) model where kinetic parameters were determined via non-linear optimisation. RESULTS: Results suggest that the thermal dose based on cumulative equivalent minutes and parameters as used for hyperthermia exposures (<43 °C) is not applicable for ablative exposures. We found R = 0.72 for temperatures between 45-60°C for the TID model. The Arrhenius parameters were frequency factor A = 3.25E43 1/s, and activation energy Ea = 281 kJ/mol. These parameters correlate well with a prior study in the same cell line, and with threshold temperatures for necrosis from in vivo studies. CONCLUSIONS: Our results suggest that standard TID model kinetic parameters based on hyperthermia studies, often also used at ablation temperatures, are not applicable at these higher temperatures for HCC cells.


Asunto(s)
Carcinoma Hepatocelular/terapia , Hipertermia Inducida , Neoplasias Hepáticas/terapia , Modelos Biológicos , Supervivencia Celular , Células Hep G2 , Calor , Humanos
18.
Nano Lett ; 12(4): 2165-70, 2012 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-22417133

RESUMEN

To address the limited tumor penetration of nanoparticle drug delivery vehicles, we report the first pH-responsive polypeptide micelle that dissociates at the low extracellular pH of solid tumors. This histidine-rich elastin-like polypeptide block copolymer self-assembles at 37 °C into spherical micelles that are stabilized by Zn(2+) and are disrupted as the pH drops from 7.4 to 6.4. These pH-sensitive micelles demonstrate better in vivo penetration and distribution in tumors than a pH-insensitive control.


Asunto(s)
Portadores de Fármacos/química , Micelas , Nanopartículas/química , Neoplasias/metabolismo , Péptidos/metabolismo , Portadores de Fármacos/análisis , Portadores de Fármacos/metabolismo , Histidina/química , Concentración de Iones de Hidrógeno , Péptidos/análisis
19.
Antimicrob Agents Chemother ; 56(8): 4391-402, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22687508

RESUMEN

With a host of new antitubercular chemotherapeutics in development, methods to assess the activity of these agents beyond mouse efficacy are needed to prioritize combinations for clinical trials. Lesions in Mycobacterium tuberculosis-infected rabbits are hypoxic, with histopathologic features that closely resemble those of human tuberculous lesions. Using [(18)F]2-fluoro-deoxy-d-glucose ([(18)F]FDG) positron emission tomography-computed tomography (PET-CT) imaging, we studied the dynamics of tuberculosis infection in rabbits, revealing an initial inflammatory response followed by a consolidative chronic disease. Five weeks after infection, as much as 23% of total lung volume was abnormal, but this was contained and to some extent reversed naturally by 9 weeks. During development of this chronic state, individual lesions in the same animal had very different fates, ranging from complete resolution to significant progression. Lesions that remained through the initial stage showed an increase in volume and tissue density over time by CT. Initiation of chemotherapy using either isoniazid (INH) or rifampin (RIF) during chronic infection reduced bacterial load with quantitative changes in [(18)F]FDG uptake, lesion density and total lesion volume measured by CT. The [(18)F]FDG PET uptake in lesions was significantly reduced with as little as 1 week of treatment, while the volume and density of lesions changed more slowly. The results from this study suggest that rabbits may be a useful surrogate species for evaluating novel chemotherapies and understanding changes in both PET and CT scans in human clinical trials.


Asunto(s)
Antituberculosos/uso terapéutico , Pulmón/patología , Imagen Multimodal , Mycobacterium tuberculosis/efectos de los fármacos , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Tuberculosis Pulmonar/tratamiento farmacológico , Animales , Carga Bacteriana/efectos de los fármacos , Modelos Animales de Enfermedad , Fluorodesoxiglucosa F18 , Granuloma/microbiología , Isoniazida/uso terapéutico , Pulmón/inmunología , Pulmón/microbiología , Conejos , Radiofármacos , Distribución Aleatoria , Rifampin/uso terapéutico , Tuberculosis Pulmonar/inmunología , Tuberculosis Pulmonar/microbiología
20.
J Vasc Interv Radiol ; 23(2): 248-55.e7, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22178041

RESUMEN

PURPOSE: A phase I dose escalation study was performed with systemically delivered lyso-thermosensitive liposomal doxorubicin (LTLD). The primary objectives were to determine the safe maximum tolerated dose (MTD), pharmacokinetic properties, and dose-limiting toxicity (DLT) of LTLD during this combination therapy. MATERIALS AND METHODS: Subjects eligible for percutaneous or surgical radiofrequency (RF) ablation with primary (n = 9) or metastatic (n = 15) tumors of the liver, with four or fewer lesions as large as 7 cm in diameter, were included. RF ablation was initiated 15 minutes after starting a 30-minute intravenous LTLD infusion. Dose levels between 20 mg/m(2) and 60 mg/m(2) were evaluated. Magnetic resonance imaging, positron emission tomography, and computed tomography were performed at predetermined intervals before and after treatment until evidence of recurrence was seen, administration of additional antitumor treatment was performed, or a total of 3 years had elapsed. RESULTS: DLT criteria were met at 60 mg/m(2), and the MTD was defined as 50 mg/m(2). RF ablation was performed during the peak of the plasma concentration-time curve in an effort to yield maximal drug deposition. LTLD produced reversible, dose-dependent neutropenia and leukopenia. CONCLUSIONS: LTLD can be safely administered systemically at the MTD (50 mg/m(2)) in combination with RF ablation, with limited and manageable toxicity. Further evaluation of this agent combined with RF ablation is warranted to determine its role in the management of liver tumors.


Asunto(s)
Ablación por Catéter/métodos , Doxorrubicina/administración & dosificación , Hipertermia Inducida/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Adulto , Anciano , Anciano de 80 o más Años , Antibióticos Antineoplásicos/administración & dosificación , Terapia Combinada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS