Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 387(20): 1843-1854, 2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-36286317

RESUMEN

BACKGROUND: Spontaneous-breathing trials can be performed with the use of either pressure-support ventilation (PSV) or a T-piece. Whether PSV trials may result in a shorter time to tracheal extubation than T-piece trials, without resulting in a higher risk of reintubation, among patients who have a high risk of extubation failure is unknown. METHODS: In this multicenter, open-label trial, we randomly assigned patients who had a high risk of extubation failure (i.e., were >65 years of age or had an underlying chronic cardiac or respiratory disease) to undergo spontaneous-breathing trials performed with the use of either PSV (with a pressure-support level of 8 cm of water and no positive end-expiratory pressure) or a T-piece. The primary outcome was the total time without exposure to invasive ventilation (reported as the number of ventilator-free days) at day 28 after the initial spontaneous-breathing trial. Secondary outcomes included extubation within 24 hours and extubation within 7 days after the initial spontaneous-breathing trial, as well as reintubation within 7 days after extubation. RESULTS: A total of 969 patients (484 in the PSV group and 485 in the T-piece group) were included in the analysis. At day 28, the median number of ventilator-free days was 27 (interquartile range, 24 to 27) in the PSV group and 27 (interquartile range, 23 to 27) in the T-piece group (difference, 0 days; 95% confidence interval [CI], -0.5 to 1; P = 0.31). Extubation was performed within 24 hours in 376 patients (77.7%) in the PSV group and in 350 patients (72.2%) in the T-piece group (difference, 5.5 percentage points; 95% CI, 0.01 to 10.9), and extubation was performed within 7 days in 473 patients (97.7%) and 458 patients (94.4%), respectively (difference, 3.3 percentage points; 95% CI, 0.8 to 5.9). Reintubation was performed in 72 of 481 patients (14.9%) in the PSV group and in 65 of 477 patients (13.6%) in the T-piece group (difference, 1.3 percentage points; 95% CI, -3.1 to 5.8). Cardiac or respiratory arrest was a reason for reintubation in 9 patients (3 in the PSV group and 6 in the T-piece group). CONCLUSIONS: Among patients who had a high risk of extubation failure, spontaneous-breathing trials performed with PSV did not result in significantly more ventilator-free days at day 28 than spontaneous-breathing trials performed with a T-piece. (Supported by the French Ministry of Health; TIP-EX ClinicalTrials.gov number, NCT04227639.).


Asunto(s)
Extubación Traqueal , Respiración con Presión Positiva , Respiración Artificial , Desconexión del Ventilador , Humanos , Extubación Traqueal/efectos adversos , Extubación Traqueal/métodos , Respiración con Presión Positiva/instrumentación , Respiración con Presión Positiva/métodos , Respiración , Respiración Artificial/métodos , Desconexión del Ventilador/efectos adversos , Desconexión del Ventilador/instrumentación , Desconexión del Ventilador/métodos , Recurrencia , Insuficiencia Respiratoria/terapia
2.
Eur Respir J ; 63(1)2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37678956

RESUMEN

BACKGROUND: In critically ill patients receiving mechanical ventilation, dyspnoea is frequent, severe and associated with an increased risk of neuropsychological sequelae. We evaluated the efficacy of sensory interventions targeting the brain rather than the respiratory system to relieve dyspnoea in mechanically ventilated patients. METHODS: Patients receiving mechanical ventilation for ≥48 h and reporting dyspnoea (unidimensional dyspnoea visual analogue scale (Dyspnoea-VAS)) first underwent increased pressure support and then, in random order, auditory stimulation (relaxing music versus pink noise) and air flux stimulation (facial versus lower limb). Treatment responses were assessed using Dyspnoea-VAS, the Multidimensional Dyspnea Profile and measures of the neural drive to breathe (airway occlusion pressure (P 0.1) and electromyography of inspiratory muscles). RESULTS: We included 46 patients (tracheotomy or intubation n=37; noninvasive ventilation n=9). Increasing pressure support decreased Dyspnoea-VAS by median 40 mm (p<0.001). Exposure to music decreased Dyspnoea-VAS compared with exposure to pink noise by median 40 mm (p<0.001). Exposure to facial air flux decreased Dyspnoea-VAS compared with limb air flux by median 30 mm (p<0.001). Increasing pressure support, but not music exposure and facial air flux, reduced P 0.1 by median 3.3 cmH2O (p<0.001). CONCLUSIONS: In mechanically ventilated patients, sensory interventions can modulate the processing of respiratory signals by the brain irrespective of the intensity of the neural drive to breathe. It should therefore be possible to alleviate dyspnoea without resorting to pharmacological interventions or having to infringe the constraints of mechanical ventilation lung protection strategies by increasing ventilatory support.


Asunto(s)
Ventilación no Invasiva , Respiración Artificial , Humanos , Enfermedad Crítica , Disnea/terapia , Respiración con Presión Positiva
3.
Respir Res ; 25(1): 280, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014448

RESUMEN

BACKGROUND: Morphine relieves dyspnea in various clinical circumstances. Whether or not this applies to patients admitted to intensive care units (ICUs) for acute respiratory failure (ARF) is unknown. We evaluated the efficacy and safety of low-dose morphine on dyspnea in patients admitted to the ICU for ARF. METHODS: In this single-center, double-blind, phase 2, randomized, controlled trial, we assigned non-intubated adults admitted to the ICU for ARF with severe dyspnea, defined by a visual analog scale for dyspnea (dyspnea-VAS) from zero (no dyspnea) to 100 mm (worst imaginable dyspnea) ≥40 mm, to receive a low dose of Morphine Hydrochloride (intravenous titration followed by subcutaneous relay) or Placebo. All patients received standard therapy, including etiological treatment and non-invasive respiratory support. RESULTS: Twenty-two patients were randomized, 11 in each group. The average dyspnea (median [interquartile range]) over 24 hours did not significantly differ between the two groups (40 [25 - 43] mm in the Morphine group vs. 40 [36 - 49] mm in the Placebo group, p=0.411). Dyspnea-VAS was lower in the Morphine group than in the Placebo group at the end of intravenous titration (30 [11 - 30] vs. 35 [30 - 44], p=0.044) and four hours later (18 [10 - 29] vs. 50 [30 - 60], p=0.043). The cumulative probability of intubation was higher in the Morphine group than in the Placebo group (p=0.046) CONCLUSION: In this phase 2 pilot trial, morphine did not improve 24-hour average dyspnea in adult patients with ARF, even though it had a statistically significant immediate effect. Of concern, Morphine use was associated with a higher intubation rate. TRIAL REGISTRATION: The protocol was declared on the ClinicalTrial.gov database (no. NCT04358133) and was published in September 2022.


Asunto(s)
Analgésicos Opioides , Disnea , Morfina , Humanos , Morfina/administración & dosificación , Método Doble Ciego , Disnea/tratamiento farmacológico , Disnea/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Anciano , Analgésicos Opioides/administración & dosificación , Analgésicos Opioides/efectos adversos , Insuficiencia Respiratoria/tratamiento farmacológico , Insuficiencia Respiratoria/diagnóstico , Resultado del Tratamiento , Adulto
4.
Anesthesiology ; 140(3): 483-494, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38088791

RESUMEN

BACKGROUND: Lung protective ventilation aims at limiting lung stress and strain. By reducing the amount of pressure transmitted by the ventilator into the lungs, diaphragm neurostimulation offers a promising approach to minimize ventilator-induced lung injury. This study investigates the physiologic effects of diaphragm neurostimulation in acute respiratory distress syndrome (ARDS) patients. The hypothesis was that diaphragm neurostimulation would improve oxygenation, would limit the distending pressures of the lungs, and would improve cardiac output. METHODS: Patients with moderate ARDS were included after 48 h of invasive mechanical ventilation and had a left subclavian catheter placed to deliver bilateral transvenous phrenic nerve stimulation. Two 60-min volume-controlled mechanical ventilation (control) sessions were interspersed by two 60-min diaphragm neurostimulation sessions delivered continually, in synchrony with the ventilator. Gas exchange, lung mechanics, chest electrical impedance tomography, and cardiac index were continuously monitored and compared across four sessions. The primary endpoint was the Pao2/fraction of inspired oxygen (Fio2) ratio at the end of each session, and the secondary endpoints were lung mechanics and hemodynamics. RESULTS: Thirteen patients were enrolled but the catheter could not be inserted in one, leaving 12 patients for analysis. All sessions were conducted without interruption and well tolerated. The Pao2/Fio2 ratio did not change during the four sessions. Median (interquartile range) plateau pressure was 23 (20 to 31) cm H2O and 21 (17 to 25) cm H2O, driving pressure was 14 (12 to 18) cm H2O and 11 (10 to 13) cm H2O, and end-inspiratory transpulmonary pressure was 9 (5 to 11) cm H2O and 7 (4 to 11) cm H2O during mechanical ventilation alone and during mechanical ventilation + neurostimulation session, respectively. The dorsal/ventral ventilation surface ratio was 0.70 (0.54 to 0.91) when on mechanical ventilation and 1.20 (0.76 to 1.33) during the mechanical ventilation + neurostimulation session. The cardiac index was 2.7 (2.3 to 3.5) l · min-1 · m-2 on mechanical ventilation and 3.0 (2.4 to 3.9) l · min-1 · m-2 on mechanical ventilation + neurostimulation. CONCLUSIONS: This proof-of-concept study showed the feasibility of short-term diaphragm neurostimulation in conjunction with mechanical ventilation in ARDS patients. Diaphragm neurostimulation was associated with positive effects on lung mechanics and on hemodynamics.


Asunto(s)
Respiración con Presión Positiva , Síndrome de Dificultad Respiratoria , Humanos , Respiración con Presión Positiva/métodos , Diafragma , Mecánica Respiratoria/fisiología , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/terapia
5.
Anesthesiology ; 140(1): 126-136, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37552079

RESUMEN

BACKGROUND: Diaphragm dysfunction and its effects on outcomes of ventilator weaning have been evaluated in mixed critical care populations using diaphragm thickening fraction (the ratio of the difference between ultrasound diaphragm thickness at end-inspiration and end-expiration to diaphragm thickness at end-expiration) or neuroventilatory efficiency (the ratio of tidal volume and peak electrical activity of the diaphragm). Such data are not available in bilateral-lung transplant recipients. The authors hypothesized that (1) diaphragm dysfunction, as defined by a diaphragm thickening fraction less than 29%, is more likely to occur in difficult weaning; (2) diaphragm thickening fraction and neuroventilatory efficiency predict weaning outcome; and (3) duration of mechanical ventilation before the first spontaneous breathing trial is associated with diaphragm dysfunction. METHODS: Adult bilateral-lung transplant patients admitted to the intensive care unit were screened at the time of the first spontaneous breathing trial (pressure-support of 5 cm H2O and 0 positive end-expiratory pressure). At the fifth minute, diaphragm thickening fraction and neuroventilatory efficiency were measured during three respiratory cycles. Weaning was classified as simple, difficult, or prolonged (successful extubation at the first spontaneous breathing trial, within three or after three spontaneous breathing trials, respectively). RESULTS: Forty-four subjects were enrolled. Diaphragm dysfunction occurred in 14 subjects (32%), all of whom had difficult weaning (78% of the subgroup of 18 patients experiencing difficult weaning). Both diaphragm thickening fraction (24 [20 to 29] vs. 39 [35 to 45]%) and neuroventilatory efficiency (34 [26 to 45] vs. 55 [43 to 62] ml/µV) were lower in difficult weaning (both P < 0.001). The areas under the receiver operator curve predicting difficult weaning were 0.88 (95% CI, 0.73 to 0.99) for diaphragm thickening fraction and 0.85 (95% CI, 0.71 to 0.95) for neuroventilatory efficiency. The duration of ventilation demonstrated a linear inverse correlation with both diaphragm thickening fraction and neuroventilatory efficiency. CONCLUSIONS: Diaphragm dysfunction is common after bilateral-lung transplantation and associated with difficult weaning. In such patients, average values for diaphragm thickening fraction and neuroventilatory efficiency were reduced compared to patients with simple weaning. Both parameters showed similar accuracy for predicting success of ventilator weaning, demonstrating an inverse relationship with duration of ventilation.


Asunto(s)
Trasplante de Pulmón , Desconexión del Ventilador , Adulto , Humanos , Diafragma/diagnóstico por imagen , Respiración Artificial , Respiración
6.
Anesthesiology ; 141(1): 87-99, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38436930

RESUMEN

BACKGROUND: Data on assessment and management of dyspnea in patients on venoarterial extracorporeal membrane oxygenation (ECMO) for cardiogenic shock are lacking. The hypothesis was that increasing sweep gas flow through the venoarterial extracorporeal membrane oxygenator may decrease dyspnea in nonintubated venoarterial ECMO patients exhibiting clinically significant dyspnea, with a parallel reduction in respiratory drive. METHODS: Nonintubated, spontaneously breathing, supine patients on venoarterial ECMO for cardiogenic shock who presented with a dyspnea visual analog scale (VAS) score of greater than or equal to 40/100 mm were included. Sweep gas flow was increased up to +6 l/min by three steps of +2 l/min each. Dyspnea was assessed with the dyspnea-VAS and the Multidimensional Dyspnea Profile. The respiratory drive was assessed by the electromyographic activity of the alae nasi and parasternal muscles. RESULTS: A total of 21 patients were included in the study. Upon inclusion, median dyspnea-VAS was 50 (interquartile range, 45 to 60) mm, and sweep gas flow was 1.0 l/min (0.5 to 2.0). An increase in sweep gas flow significantly decreased dyspnea-VAS (50 [45 to 60] at baseline vs. 20 [10 to 30] at 6 l/min; P < 0.001). The decrease in dyspnea was greater for the sensory component of dyspnea (-50% [-43 to -75]) than for the affective and emotional components (-17% [-0 to -25] and -12% [-0 to -17]; P < 0.001). An increase in sweep gas flow significantly decreased electromyographic activity of the alae nasi and parasternal muscles (-23% [-36 to -10] and -20 [-41 to -0]; P < 0.001). There was a significant correlation between the sweep gas flow and the dyspnea-VAS (r = -0.91; 95% CI, -0.94 to -0.87), between the respiratory drive and the sensory component of dyspnea (r = 0.29; 95% CI, 0.13 to 0.44) between the respiratory drive and the affective component of dyspnea (r = 0.29; 95% CI, 0.02 to 0.54) and between the sweep gas flow and the alae nasi and parasternal (r = -0.31; 95% CI, -0.44 to -0.22; and r = -0.25; 95% CI, -0.44 to -0.16). CONCLUSIONS: In critically ill patients with venoarterial ECMO, an increase in sweep gas flow through the oxygenation membrane decreases dyspnea, possibly mediated by a decrease in respiratory drive.


Asunto(s)
Disnea , Oxigenación por Membrana Extracorpórea , Humanos , Oxigenación por Membrana Extracorpórea/métodos , Disnea/terapia , Disnea/fisiopatología , Disnea/etiología , Masculino , Proyectos Piloto , Femenino , Persona de Mediana Edad , Choque Cardiogénico/terapia , Choque Cardiogénico/fisiopatología , Anciano , Adulto
7.
Curr Opin Crit Care ; 30(2): 121-130, 2024 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-38441088

RESUMEN

PURPOSE OF REVIEW: In the current review, we aim to highlight the evolving evidence on the diagnosis, prevention and treatment of critical illness weakness (CIW) and critical illness associated diaphragmatic weakness (CIDW). RECENT FINDINGS: In the ICU, several risk factors can lead to CIW and CIDW. Recent evidence suggests that they have different pathophysiological mechanisms and impact on outcomes, although they share common risk factors and may overlap in several patients. Their diagnosis is challenging, because CIW diagnosis is primarily clinical and, therefore, difficult to obtain in the ICU population, and CIDW diagnosis is complex and not easily performed at the bedside. All of these issues lead to underdiagnosis of CIW and CIDW, which significantly increases the risk of complications and the impact on both short and long term outcomes. Moreover, recent studies have explored promising diagnostic techniques that are may be easily implemented in daily clinical practice. In addition, this review summarizes the latest research aimed at improving how to prevent and treat CIW and CIDW. SUMMARY: This review aims to clarify some uncertain aspects and provide helpful information on developing monitoring techniques and therapeutic interventions for managing CIW and CIDW.


Asunto(s)
Enfermedad Crítica , Unidades de Cuidados Intensivos , Humanos , Debilidad Muscular/etiología , Factores de Riesgo
8.
Crit Care ; 28(1): 245, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014512

RESUMEN

BACKGROUND: In mechanically ventilated patients, diaphragm ultrasound can identify diaphragm weakness and predict weaning failure. We evaluated whether a novel operator-independent ultrasound-based medical device allowing continuous monitoring of the diaphragm (CUSdi) could reliably (1) measure diaphragm excursion (EXdi) and peak contraction velocity (PCVdi), (2) predict weaning outcome, and (3) approximate transdiaphragmatic pressure (Pdi). METHODS: In 49 mechanically ventilated patients, CUSdi was recorded during a 30-min spontaneous breathing trial (SBT), and EXdi and PCVdi were measured. In subgroups of patients, standard ultrasound measurement of EXdi and PCVdi was performed (n = 36), and Pdi derived parameters (peak and pressure time product, n = 30) were measured simultaneously. RESULTS: The agreement bias between standard ultrasound and CUSdi for EXdi was 0.1 cm (95% confidence interval -0.7-0.9 cm). The regression of Passing-Bablok indicated a lack of systematic difference between EXdi measured with standard ultrasound and CUSdi, which were positively correlated (Rho = 0.84, p < 0.001). Weaning failure was observed in 54% of patients. One, two and three minutes after the onset of the SBT, EXdi was higher in the weaning success group than in the failure group. Two minutes after the onset of the SBT, an EXdi < 1.1 cm predicted weaning failure with a sensitivity of 0.83, a specificity of 0.68, a positive predictive value of 0.76, and a negative predictive value of 0.24. There was a weak correlation between EXdi and both peak Pdi (r = 0.22, 95% confidence interval 0.15 - 0.28) and pressure time product (r = 0.13, 95% confidence interval 0.06 - 0.20). Similar results were observed with PCVdi. CONCLUSIONS: Operator-independent continuous diaphragm monitoring quantifies EXdi reliably and can predict weaning failure with an identified cut-off value of 1.1 cm. Trial registration clinicaltrial.gov, NCT04008875 (submitted 12 April 2019, posted 5 July 2019) and NCT03896048 (submitted 27 March 2019, posted 29 March 2019).


Asunto(s)
Diafragma , Ultrasonografía , Desconexión del Ventilador , Humanos , Desconexión del Ventilador/métodos , Desconexión del Ventilador/normas , Diafragma/diagnóstico por imagen , Diafragma/fisiopatología , Estudios Prospectivos , Masculino , Femenino , Ultrasonografía/métodos , Ultrasonografía/normas , Persona de Mediana Edad , Anciano , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Respiración Artificial/métodos , Valor Predictivo de las Pruebas
9.
J Intensive Care Med ; 39(2): 146-152, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37632128

RESUMEN

PURPOSE: Acute kidney injury is a frequent complication of acute respiratory distress syndrome (ARDS). We aim to study the evolution of kidney function in patients presenting severe ARDS and requiring veno-venous extracorporeal membrane oxygenation (VV ECMO). METHODS: We conducted a multicenter retrospective study, including adult patients requiring VV ECMO for ARDS. The primary outcome was the evolution of the serum creatinine level after VV ECMO initiation. Secondary outcomes were change in urine output, and urine biochemical parameters after VV ECMO initiation. RESULTS: One hundred and two patients were included. VV ECMO was initiated after a median of 6 days of mechanical ventilation, mainly for ARDS caused by COVID-19 (73%). Serum creatinine level did not significantly differ after VV ECMO initiation (P = .20). VV ECMO was associated with a significant increase in daily urine output (+6.6 mL/kg/day, [3.8;9.3] P < .001), even after adjustment for potential confounding factors; with an increase in natriuresis. The increase in urine output under VV ECMO was associated with a reduced risk of receiving kidney replacement therapy (OR 0.4 [0.2;0.8], P = .026). CONCLUSIONS: VV ECMO initiation in severe ARDS is associated with an increase in daily urine output and natriuresis, without change in glomerular filtration rate.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Adulto , Humanos , Estudios Retrospectivos , Oxigenación por Membrana Extracorpórea/efectos adversos , Creatinina , Natriuresis , Síndrome de Dificultad Respiratoria/etiología , Riñón
10.
Am J Respir Crit Care Med ; 207(10): 1275-1282, 2023 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-36917765

RESUMEN

Diaphragm neurostimulation consists of placing electrodes directly on or in proximity to the phrenic nerve(s) to elicit diaphragmatic contractions. Since its initial description in the 18th century, indications have shifted from cardiopulmonary resuscitation to long-term ventilatory support. Recently, the technical development of devices for temporary diaphragm neurostimulation has opened up the possibility of a new era for the management of mechanically ventilated patients. Combining positive pressure ventilation with diaphragm neurostimulation offers a potentially promising new approach to the delivery of mechanical ventilation which may benefit multiple organ systems. Maintaining diaphragm contractions during ventilation may attenuate diaphragm atrophy and accelerate weaning from mechanical ventilation. Preventing atelectasis and preserving lung volume can reduce lung stress and strain and improve homogeneity of ventilation, potentially mitigating ventilator-induced lung injury. Furthermore, restoring the thoracoabdominal pressure gradient generated by diaphragm contractions may attenuate the drop in cardiac output induced by positive pressure ventilation. Experimental evidence suggests diaphragm neurostimulation may prevent neuroinflammation associated with mechanical ventilation. This review describes the historical development and evolving approaches to diaphragm neurostimulation during mechanical ventilation and surveys the potential mechanisms of benefit. The review proposes a research agenda and offers perspectives for the future of diaphragm neurostimulation assisted mechanical ventilation for critically ill patients.


Asunto(s)
Diafragma , Respiración Artificial , Humanos , Diafragma/fisiología , Enfermedad Crítica/terapia , Respiración con Presión Positiva , Respiración
11.
Crit Care ; 27(1): 136, 2023 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-37031182

RESUMEN

BACKGROUND: In patients on mechanical ventilation, positive end-expiratory pressure (PEEP) can decrease cardiac output through a decrease in cardiac preload and/or an increase in right ventricular afterload. Increase in central blood volume by fluid administration or passive leg raising (PLR) may reverse these phenomena through an increase in cardiac preload and/or a reopening of closed lung microvessels. We hypothesized that a transient decrease in PEEP (PEEP-test) may be used as a test to detect volume responsiveness. METHODS: Mechanically ventilated patients with PEEP ≥ 10 cmH2O ("high level") and without spontaneous breathing were prospectively included. Volume responsiveness was assessed by a positive PLR-test, defined as an increase in pulse-contour-derived cardiac index (CI) during PLR ≥ 10%. The PEEP-test consisted in reducing PEEP from the high level to 5 cmH2O for one minute. Pulse-contour-derived CI (PiCCO2) was monitored during PLR and the PEEP-test. RESULTS: We enrolled 64 patients among whom 31 were volume responsive. The median increase in CI during PLR was 14% (11-16%). The median PEEP at baseline was 12 (10-15) cmH2O and the PEEP-test resulted in a median decrease in PEEP of 7 (5-10) cmH2O, without difference between volume responsive and unresponsive patients. Among volume responsive patients, the PEEP-test induced a significant increase in CI of 16% (12-20%) (from 2.4 ± 0.7 to 2.9 ± 0.9 L/min/m2, p < 0.0001) in comparison with volume unresponsive patients. In volume unresponsive patients, PLR and the PEEP-test increased CI by 2% (1-5%) and 6% (3-8%), respectively. Volume responsiveness was predicted by an increase in CI > 8.6% during the PEEP-test with a sensitivity of 96.8% (95% confidence interval (95%CI): 83.3-99.9%) and a specificity of 84.9% (95%CI 68.1-94.9%). The area under the receiver operating characteristic curve of the PEEP-test for detecting volume responsiveness was 0.94 (95%CI 0.85-0.98) (p < 0.0001 vs. 0.5). Spearman's correlation coefficient between the changes in CI induced by PLR and the PEEP-test was 0.76 (95%CI 0.63-0.85, p < 0.0001). CONCLUSIONS: A CI increase > 8.6% during a PEEP-test, which consists in reducing PEEP to 5 cmH2O, reliably detects volume responsiveness in mechanically ventilated patients with a PEEP ≥ 10 cmH2O. Trial registration ClinicalTrial.gov (NCT 04,023,786). Registered July 18, 2019. Ethics Committee approval CPP Est III (N° 2018-A01599-46).


Asunto(s)
Volumen Sanguíneo , Gasto Cardíaco , Fluidoterapia , Corazón , Respiración con Presión Positiva , Respiración Artificial , Humanos , Volumen Sanguíneo/fisiología , Gasto Cardíaco/fisiología , Técnicas de Diagnóstico Cardiovascular , Técnicas de Diagnóstico del Sistema Respiratorio , Fluidoterapia/métodos , Corazón/fisiopatología , Hemodinámica , Respiración con Presión Positiva/efectos adversos , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Curva ROC
12.
Am J Respir Crit Care Med ; 205(10): 1169-1178, 2022 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-35108175

RESUMEN

Rationale: Diaphragm dysfunction is frequently observed in critically ill patients with difficult weaning from mechanical ventilation. Objectives: To evaluate the effects of temporary transvenous diaphragm neurostimulation on weaning outcome and maximal inspiratory pressure. Methods: Multicenter, open-label, randomized, controlled study. Patients aged ⩾18 years on invasive mechanical ventilation for ⩾4 days and having failed at least two weaning attempts received temporary transvenous diaphragm neurostimulation using a multielectrode stimulating central venous catheter (bilateral phrenic stimulation) and standard of care (treatment) (n = 57) or standard of care (control) (n = 55). In seven patients, the catheter could not be inserted, and in seven others, pacing therapy could not be delivered; consequently, data were available for 43 patients. The primary outcome was the proportion of patients successfully weaned. Other endpoints were mechanical ventilation duration, 30-day survival, maximal inspiratory pressure, diaphragm-thickening fraction, adverse events, and stimulation-related pain. Measurements and Main Results: The incidences of successful weaning were 82% (treatment) and 74% (control) (absolute difference [95% confidence interval (CI)], 7% [-10 to 25]), P = 0.59. Mechanical ventilation duration (mean ± SD) was 12.7 ± 9.9 days and 14.1 ± 10.8 days, respectively, P = 0.50; maximal inspiratory pressure increased by 16.6 cm H2O and 4.8 cm H2O, respectively (difference [95% CI], 11.8 [5 to 19]), P = 0.001; and right hemidiaphragm thickening fraction during unassisted spontaneous breathing was +17% and -14%, respectively, P = 0.006, without correlation with changes in maximal inspiratory pressure. Serious adverse event frequency was similar in both groups. Median stimulation-related pain in the treatment group was 0 (no pain). Conclusions: Temporary transvenous diaphragm neurostimulation did not increase the proportion of successful weaning from mechanical ventilation. It was associated with a significant increase in maximal inspiratory pressure, suggesting reversal of the course of diaphragm dysfunction. Clinical trial registered with www.clinicaltrials.gov (NCT03096639) and the European Database on Medical Devices (CIV-17-06-020004).


Asunto(s)
Diafragma , Nervio Frénico , Anciano , Humanos , Presiones Respiratorias Máximas , Dolor , Respiración Artificial/efectos adversos , Desconexión del Ventilador
13.
JAMA ; 330(24): 2343-2353, 2023 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-38038395

RESUMEN

Importance: Prone positioning may improve outcomes in patients with severe acute respiratory distress syndrome (ARDS), but it is unknown whether prone positioning improves clinical outcomes among patients with ARDS who are undergoing venovenous extracorporeal membrane oxygenation (VV-ECMO) compared with supine positioning. Objective: To test whether prone positioning vs supine positioning decreases the time to successful ECMO weaning in patients with severe ARDS supported by VV-ECMO. Design, Setting, and Participants: Randomized clinical trial of patients with severe ARDS undergoing VV-ECMO for less than 48 hours at 14 intensive care units (ICUs) in France between March 3, 2021, and December 7, 2021. Interventions: Patients were randomized 1:1 to prone positioning (at least 4 sessions of 16 hours) (n = 86) or to supine positioning (n = 84). Main Outcomes and Measures: The primary outcome was time to successful ECMO weaning within 60 days following randomization. Secondary outcomes included ECMO and mechanical ventilation-free days, ICU and hospital length of stay, skin pressure injury, serious adverse events, and all-cause mortality at 90-day follow-up. Results: Among 170 randomized patients (median age, 51 [IQR, 43-59] years; n = 60 women [35%]), median respiratory system compliance was 15.0 (IQR, 10.7-20.6) mL/cm H2O; 159 patients (94%) had COVID-19-related ARDS; and 164 (96%) were in prone position before ECMO initiation. Within 60 days of enrollment, 38 of 86 patients (44%) had successful ECMO weaning in the prone ECMO group compared with 37 of 84 (44%) in the supine ECMO group (risk difference, 0.1% [95% CI, -14.9% to 15.2%]; subdistribution hazard ratio, 1.11 [95% CI, 0.71-1.75]; P = .64). Within 90 days, no significant difference was observed in ECMO duration (28 vs 32 days; difference, -4.9 [95% CI, -11.2 to 1.5] days; P = .13), ICU length of stay, or 90-day mortality (51% vs 48%; risk difference, 2.4% [95% CI, -13.9% to 18.6%]; P = .62). No serious adverse events were reported during the prone position procedure. Conclusions and Relevance: Among patients with severe ARDS supported by VV-ECMO, prone positioning compared with supine positioning did not significantly reduce time to successful weaning of ECMO. Trial Registration: ClinicalTrials.gov Identifier: NCT04607551.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Humanos , Femenino , Persona de Mediana Edad , Oxigenación por Membrana Extracorpórea/métodos , Posición Prona , Respiración Artificial/métodos , Unidades de Cuidados Intensivos , Síndrome de Dificultad Respiratoria/terapia , Síndrome de Dificultad Respiratoria/mortalidad
14.
Anesthesiology ; 136(1): 162-175, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34788380

RESUMEN

BACKGROUND: The relationship between the diaphragm thickening fraction and the transdiaphragmatic pressure, the reference method to evaluate the diaphragm function, has not been clearly established. This study investigated the global and intraindividual relationship between the thickening fraction of the diaphragm and the transdiaphragmatic pressure. The authors hypothesized that the diaphragm thickening fraction would be positively and significantly correlated to the transdiaphragmatic pressure, in both healthy participants and ventilated patients. METHODS: Fourteen healthy individuals and 25 mechanically ventilated patients (enrolled in two previous physiologic investigations) participated in the current study. The zone of apposition of the right hemidiaphragm was imaged simultaneously to transdiaphragmatic pressure recording within different breathing conditions, i.e., external inspiratory threshold loading in healthy individuals and various pressure support settings in patients. A blinded offline breath-by-breath analysis synchronously computed the changes in transdiaphragmatic pressure, the diaphragm pressure-time product, and diaphragm thickening fraction. Global and intraindividual relationships between variables were assessed. RESULTS: In healthy subjects, both changes in transdiaphragmatic pressure and diaphragm pressure-time product were moderately correlated to diaphragm thickening fraction (repeated measures correlation = 0.40, P < 0.0001; and repeated measures correlation = 0.38, P < 0.0001, respectively). In mechanically ventilated patients, changes in transdiaphragmatic pressure and thickening fraction were weakly correlated (repeated measures correlation = 0.11, P = 0.008), while diaphragm pressure-time product and thickening fraction were not (repeated measures correlation = 0.04, P = 0.396). Individually, changes in transdiaphragmatic pressure and thickening fraction were significantly correlated in 8 of 14 healthy subjects (ρ = 0.30 to 0.85, all P < 0.05) and in 2 of 25 mechanically ventilated patients (ρ = 0.47 to 0.64, all P < 0.05). Diaphragm pressure-time product and thickening fraction correlated in 8 of 14 healthy subjects (ρ = 0.41 to 0.82, all P < 0.02) and in 2 of 25 mechanically ventilated patients (ρ = 0.63 to 0.66, all P < 0.01). CONCLUSIONS: Overall, diaphragm function as assessed with transdiaphragmatic pressure was weakly related to diaphragm thickening fraction. The diaphragm thickening fraction should not be used in healthy subjects or ventilated patients when changes in diaphragm function are evaluated.


Asunto(s)
Diafragma/diagnóstico por imagen , Diafragma/fisiología , Presión , Respiración Artificial/métodos , Pruebas de Función Respiratoria/métodos , Adulto , Anciano , Voluntarios Sanos , Humanos , Persona de Mediana Edad , Tamaño de los Órganos/fisiología , Estudios Prospectivos , Respiración Artificial/tendencias , Pruebas de Función Respiratoria/tendencias , Adulto Joven
15.
Crit Care ; 26(1): 162, 2022 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-35668459

RESUMEN

BACKGROUND: Whether dyspnea is present before starting a spontaneous breathing trial (SBT) and whether it may affect the outcome of the SBT is unknown. Mechanical Ventilation-Respiratory Distress Observation Scale (MV-RDOS) has been proposed as a reliable surrogate of dyspnea in non-communicative intubated patients. In the present study, we sought (1) to describe the evolution of the MV-RDOS during a SBT and (2) to investigate whether MV-RDOS can predict the outcome of the SBT. METHODS: Prospective, single-center study in a twenty-two bed ICU in a tertiary center. Patients intubated since more 48 h who had failed a first SBT were eligible if they meet classical readiness to wean criteria. The MV-RDOS was assessed before, at 2-min, 15-min and 30-min (end) of the SBT. The presence of clinically important dyspnea was inferred by a MV-RDOS value ≥ 2.6. RESULTS: Fifty-eight patients (age 63 [51-70], SAPS II 66 [51-76]; med [IQR]) were included. Thirty-three (57%) patients failed the SBT, whose 18 (55%) failed before 15-min. Twenty-five (43%) patients successfully passed the SBT. A MV-RDOS ≥ 2.6 was present in ten (17%) patients before to start the SBT. All these ten patients subsequently failed the SBT. A MV-RDOS ≥ 2.6 at 2-min predicted a SBT failure with a 51% sensibility and a 88% specificity (AUC 0.741 95% confidence interval [CI] 0.616-0.866, p = 0.002). Best cut-off value at 2-min was 4.3 and predicted SBT failure with a 27% sensibility and a 96% specificity. CONCLUSION: Despite patients met classical readiness to wean criteria, respiratory distress assessed with the MV-RDOS was frequent at the beginning of SBT. Measuring MV-RDOS before to initiate a SBT could avoid undue procedure and reduce patient's exposure to unnecessary mechanical ventilation weaning failure and distress.


Asunto(s)
Síndrome de Dificultad Respiratoria , Desconexión del Ventilador , Disnea/diagnóstico , Disnea/etiología , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial , Desconexión del Ventilador/métodos
16.
Crit Care ; 26(1): 99, 2022 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-35395861

RESUMEN

BACKGROUND: Diaphragm ultrasonography is rapidly evolving in both critical care and research. Nevertheless, methodologically robust guidelines on its methodology and acquiring expertise do not, or only partially, exist. Therefore, we set out to provide consensus-based statements towards a universal measurement protocol for diaphragm ultrasonography and establish key areas for research. METHODS: To formulate a robust expert consensus statement, between November 2020 and May 2021, a two-round, anonymous and online survey-based Delphi study among experts in the field was performed. Based on the literature review, the following domains were chosen: "Anatomy and physiology", "Transducer Settings", "Ventilator Impact", "Learning and expertise", "Daily practice" and "Future directions". Agreement of ≥ 68% (≥ 10 panelists) was needed to reach consensus on a question. RESULTS: Of 18 panelists invited, 14 agreed to participate in the survey. After two rounds, the survey included 117 questions of which 42 questions were designed to collect arguments and opinions and 75 questions aimed at reaching consensus. Of these, 46 (61%) consensus was reached. In both rounds, the response rate was 100%. Among others, there was agreement on measuring thickness between the pleura and peritoneum, using > 10% decrease in thickness as cut-off for atrophy and using 40 examinations as minimum training to use diaphragm ultrasonography in clinical practice. In addition, key areas for research were established. CONCLUSION: This expert consensus statement presents the first set of consensus-based statements on diaphragm ultrasonography methodology. They serve to ensure high-quality and homogenous measurements in daily clinical practice and in research. In addition, important gaps in current knowledge and thereby key areas for research are established. Trial registration The study was pre-registered on the Open Science Framework with registration digital object identifier https://doi.org/10.17605/OSF.IO/HM8UG .


Asunto(s)
Enfermedad Crítica , Diafragma , Cuidados Críticos , Enfermedad Crítica/terapia , Técnica Delphi , Diafragma/diagnóstico por imagen , Humanos , Ultrasonografía
17.
J Clin Monit Comput ; 36(1): 161-167, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33385260

RESUMEN

Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivity index (RRI) and the renal venous flow (RVF) in ARDS patients with SARS-CoV-2 and in ARDS patients due to other etiologies. Prospective, observational pilot study performed on 30 mechanically ventilated patients (15 with SARS-COV-2 ARDS and 15 with ARDS). Mechanical ventilation settings included constant-flow controlled ventilation, a tidal volume of 6 ml/kg of ideal body weight and the PEEP level titrated to the lowest driving pressure. Ultrasound Doppler measurements of RRI and RVF pattern were performed in each patient. Patients with SARS-COV-2 ARDS had higher RRI than patients with ARDS (0.71[0.67-0.78] vs 0.64[0.60-0.74], p = 0.04). RVF was not-continuous in 9/15 patients (71%) in the SARS-COV-2 ARDS group and in and 5/15 (33%) in the ARDS group (p = 0.27). A linear correlation was found between PEEP and RRI in patients with SARS-COV-2 ARDS (r2 = 0.31; p = 0.03) but not in patients with ARDS. Occurrence of AKI was 53% in patients with SARS-COV-2 ARDS and 33% in patients with ARDS (p = 0.46). We found a more pronounced impairment in renal blood flow in mechanically ventilated patients with SARS-COV-2 ARDS, compared with patients with "classical" ARDS.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Humanos , Proyectos Piloto , Estudios Prospectivos , Circulación Renal , Respiración Artificial , Síndrome de Dificultad Respiratoria/terapia , SARS-CoV-2
18.
Eur Respir J ; 58(5)2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33875492

RESUMEN

BACKGROUND: This study investigated dyspnoea intensity and respiratory muscle ultrasound early after extubation to predict extubation failure. METHODS: The study was conducted prospectively in two intensive care units in France and Canada. Patients intubated for at least 48 h were studied within 2 h after an extubation following a successful spontaneous breathing trial. Dyspnoea was evaluated by a dyspnoea visual analogue scale (Dyspnoea-VAS) ranging from 0 to 10 and the Intensive Care Respiratory Distress Observational Scale (IC-RDOS). The ultrasound thickening fraction of the parasternal intercostal and the diaphragm was measured; limb muscle strength was evaluated using the Medical Research Council (MRC) score (range 0-60). RESULTS: Extubation failure occurred in 21 out of 122 enrolled patients (17%). The median (interquartile range (IQR)) Dyspnoea-VAS and IC-RDOS were higher in patients with extubation failure versus success: 7 (4-9) versus 3 (1-5) (p<0.001) and 3.7 (1.8-5.8) versus 1.7 (1.5-2.1) (p<0.001), respectively. The median (IQR) ratio of parasternal intercostal muscle to diaphragm thickening fraction was significantly higher and MRC was lower in patients with extubation failure compared with extubation success: 0.9 (0.4-2.1) versus 0.3 (0.2-0.5) (p<0.001) and 45 (36-50) versus 52 (44-60) (p=0.012), respectively. The thickening fraction of the parasternal intercostal and its ratio to diaphragm thickening showed the highest area under the receiver operating characteristic curve (AUC) for an early prediction of extubation failure (0.81). AUCs of Dyspnoea-VAS and IC-RDOS reached 0.78 and 0.74, respectively. CONCLUSIONS: Respiratory muscle ultrasound and dyspnoea measured within 2 h after extubation predict subsequent extubation failure.


Asunto(s)
Extubación Traqueal , Desconexión del Ventilador , Diafragma/diagnóstico por imagen , Disnea , Humanos , Estudios Prospectivos , Respiración Artificial
19.
Crit Care ; 25(1): 186, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34074313

RESUMEN

BACKGROUND: In acute respiratory distress syndrome (ARDS), extravascular lung water index (EVLWi) and pulmonary vascular permeability index (PVPI) measured by transpulmonary thermodilution reflect the degree of lung injury. Whether EVLWi and PVPI are different between non-COVID-19 ARDS and the ARDS due to COVID-19 has never been reported. We aimed at comparing EVLWi, PVPI, respiratory mechanics and hemodynamics in patients with COVID-19 ARDS vs. ARDS of other origin. METHODS: Between March and October 2020, in an observational study conducted in intensive care units from three university hospitals, 60 patients with COVID-19-related ARDS monitored by transpulmonary thermodilution were compared to the 60 consecutive non-COVID-19 ARDS admitted immediately before the COVID-19 outbreak between December 2018 and February 2020. RESULTS: Driving pressure was similar between patients with COVID-19 and non-COVID-19 ARDS, at baseline as well as during the study period. Compared to patients without COVID-19, those with COVID-19 exhibited higher EVLWi, both at the baseline (17 (14-21) vs. 15 (11-19) mL/kg, respectively, p = 0.03) and at the time of its maximal value (24 (18-27) vs. 21 (15-24) mL/kg, respectively, p = 0.01). Similar results were observed for PVPI. In COVID-19 patients, the worst ratio between arterial oxygen partial pressure over oxygen inspired fraction was lower (81 (70-109) vs. 100 (80-124) mmHg, respectively, p = 0.02) and prone positioning and extracorporeal membrane oxygenation (ECMO) were more frequently used than in patients without COVID-19. COVID-19 patients had lower maximal lactate level and maximal norepinephrine dose than patients without COVID-19. Day-60 mortality was similar between groups (57% vs. 65%, respectively, p = 0.45). The maximal value of EVLWi and PVPI remained independently associated with outcome in the whole cohort. CONCLUSION: Compared to ARDS patients without COVID-19, patients with COVID-19 had similar lung mechanics, but higher EVLWi and PVPI values from the beginning of the disease. This was associated with worse oxygenation and with more requirement of prone positioning and ECMO. This is compatible with the specific lung inflammation and severe diffuse alveolar damage related to COVID-19. By contrast, patients with COVID-19 had fewer hemodynamic derangement. Eventually, mortality was similar between groups. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION: ClinicalTrials.gov (NCT04337983). Registered 30 March 2020-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04337983 .


Asunto(s)
COVID-19/metabolismo , Permeabilidad Capilar , Agua Pulmonar Extravascular/metabolismo , Síndrome de Dificultad Respiratoria/metabolismo , Índice de Severidad de la Enfermedad , COVID-19/complicaciones , Hemodinámica , Humanos , Pulmón/irrigación sanguínea , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Pronóstico , Edema Pulmonar/metabolismo , Termodilución
20.
Crit Care ; 25(1): 64, 2021 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-33593412

RESUMEN

BACKGROUND: Acute increases in muscle sonographic echodensity reflect muscle injury. Diaphragm echodensity has not been measured in mechanically ventilated patients. We undertook to develop a technique to characterize changes in diaphragm echodensity during mechanical ventilation and to assess whether these changes are correlated with prolonged mechanical ventilation. METHODS: Diaphragm ultrasound images were prospectively collected in mechanically ventilated patients and in 10 young healthy subjects. Echodensity was quantified based on the right-skewed distribution of grayscale values (50th percentile, ED50; 85th percentile, ED85). Intra- and inter-analyzer measurement reproducibility was determined. Outcomes recorded included duration of ventilation and ICU complications (including reintubation, tracheostomy, prolonged ventilation, or death). RESULTS: Echodensity measurements were obtained serially in 34 patients comprising a total of 104 images. Baseline (admission) diaphragm ED85 was increased in mechanically ventilated patients compared to younger healthy subjects (median 56, interquartile range (IQR) 42-84, vs. 39, IQR 36-52, p = 0.04). Patients with an initial increase in median echodensity over time (≥ + 10 in ED50 from baseline) had fewer ventilator-free days to day 60 (n = 13, median 46, IQR 0-52) compared to patients without this increase (n = 21, median 53 days, IQR 49-56, unadjusted p = 0.03). Both decreases and increases in diaphragm thickness during mechanical ventilation were associated with increases in ED50 over time (adjusted p = 0.03, conditional R2 = 0.80) and the association between increase in ED50 and outcomes persisted after adjusting for changes in diaphragm thickness. CONCLUSIONS: Many patients exhibit increased diaphragm echodensity at the outset of mechanical ventilation. Increases in diaphragm echodensity during the early course of mechanical ventilation are associated with prolonged mechanical ventilation. Both decreases and increases in diaphragm thickness during mechanical ventilation are associated with increased echodensity.


Asunto(s)
Diafragma/fisiopatología , Respiración Artificial/estadística & datos numéricos , Pesos y Medidas/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ontario , Evaluación de Resultado en la Atención de Salud/métodos , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Reproducibilidad de los Resultados , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Ultrasonografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA