Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Respir Res ; 25(1): 22, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38195540

RESUMEN

BACKGROUND: Malignant pleural effusion is mostly a complication of advanced malignant tumors. However, the cancer markers such as carbohydrate antigen 125 (CA 125), carbohydrate antigen 15-3 (CA 15-3), carbohydrate antigen 19-9 (CA 19-9), and cytokeratin fragment 21-1 (CYFRA 21-1) have low sensitivity and organ specificity for detecting malignant pleural effusion. RESEARCH QUESTION: Is IR808@MnO nano-near infrared fluorescent dye worthy for the diagnosis in differentiating benign and malignant pleural effusions. STUDY DESIGN AND METHODS: This experiment was carried out to design and characterize the materials for in vitro validation of the new dye in malignant tumor cells in the A549 cell line and in patients with adenocarcinoma pleural effusion. The dye was verified to possess tumor- specific targeting capabilities. Subsequently, a prospective hospital-based observational study was conducted, enrolling 106 patients and excluding 28 patients with unknown diagnoses. All patients underwent histopathological analysis of thoracoscopic biopsies, exfoliative cytological analysis of pleural fluid, and analysis involving the new dye. Statistical analyses were performed using Microsoft Excel, GraphPad Prism, and the R language. RESULTS: The size of IR808@MnO was 136.8 ± 2.9 nm, with peak emission at 808 nm, and it has near-infrared fluorescence properties. Notably, there was a significant difference in fluorescence values between benign and malignant cell lines (p < 0.0001). The malignant cell lines tested comprised CL1-5, A549, MDA-MB-468, U-87MG, MKN-7, and Hela, while benign cell lines were BEAS-2B, HUVEC, HSF, and VE. The most effective duration of action was identified as 30 min at a concentration of 5 µl. This optimal duration of action and concentration were consistent in patients with lung adenocarcinoma accompanied by pleural effusion and 5 µl. Of the 106 patients examined, 28 remained undiagnosed, 39 were diagnosed with malignant pleural effusions, and the remaining 39 with benign pleural effusions. Employing the new IR808@MnO staining method, the sensitivity stood at 74.4%, specificity at 79.5%, a positive predictive value of 69.2%, and a negative predictive value of 82.1%. The area under the ROC curve was recorded as 0.762 (95% CI: 0.652-0.872). The confusion matrix revealed a positive predictive value of 75.7%, a negative predictive value of 75.6%, a false positive rate of 22.5%, and a false negative rate of 26.3%. INTERPRETATION: The IR808@MnO fluorescent probe represents an efficient, sensitive, and user-friendly diagnostic tool for detecting malignant pleural fluid, underscoring its significant potential for clinical adoption.


Asunto(s)
Neoplasias Pulmonares , Derrame Pleural Maligno , Derrame Pleural , Humanos , Derrame Pleural Maligno/diagnóstico , Colorantes Fluorescentes , Estudios Prospectivos , Derrame Pleural/diagnóstico por imagen , Carbohidratos
2.
Oncotarget ; 8(40): 68863-68872, 2017 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-28978163

RESUMEN

BACKGROUND: Conventional measurements are not always helpful in the diagnosis of malignant mesothelioma (MM). Increasing studies indicate that loss of BRCA1-associated protein 1 (BAP1) detected by immunohistochemistry (IHC) is a useful diagnostic marker for MM. In this meta-analysis, we investigated the diagnostic accuracy of BAP1 in MM. RESULTS: In total, 12 eligible studies with a total of 1824 patients were selected. Results indicated that loss of BAP1 sustained a pooled sensitivity of 0.56 (95% CI, 0.50-0.62), specificity of 1.00 (95% CI, 0.95-1.00), PLR of 548.82 (95% CI, 11.31-2.7 × 104), NLR of 0.44 (95% CI, 0.39-0.50), DOR of 1247.78 (95% CI, 25.08 -6.2 × 104) in discriminating MM from non-MM. The AUC of 0.72, reflecting the SROC, indicated moderate diagnostic accuracy. Subgroup analysis showed that BAP1 detection in histological specimens owned the higher diagnostic performance than cytological ones. In addition, BAP1 showed superior diagnostic accuracy in epithelioid MM than biphasic or sarcomatoid MM. MATERIALS AND METHODS: PubMed, Embase and the Cochrane Library and reference lists of related articles were searched, and studies that evaluated the utility of BAP1 in MM were included. Data from eligible studies were pooled to estimate sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR). Summary receiver operating curves (SROC) was applied to estimate overall diagnostic accuracy. CONCLUSIONS: Current meta-analysis indicates that detection of BAP1 by IHC is a useful diagnostic marker for MM. Loss of BAP1 almost provides confirming diagnosis for MM, while positive staining for BAP1 is not enough to exclude non-MM.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA