Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 110
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 44(9): 976-986, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32348583

RESUMEN

Total artificial heart (TAH) represents the only valid alternative to heart transplantation, whose number is continuously increasing in recent years. The TAH used in this work, is a biventricular pulsatile, electrically powered, hydraulically actuated flow pump with all components embodied in a single device. One of the major issues for TAHs is the washout capability of the device, strictly correlated with the presence of blood stagnation sites. The aim of this work was to develop a numerical methodology to study the washout coupled with the fluid dynamics evaluation of a total artificial heart under nominal working conditions. The first part of this study focussed on the CT scan analysis of the hybrid membrane kinematics during TAH operation, which was replicated with a fluid-structure interaction simulation in the second part. The difference in percentage between the in vitro and in silico flow rates and stroke volume is 9.7% and 6.3%, respectively. An injection of contrast blood was simulated, and a good washout performance was observed and quantified with the volume fraction of the contrast blood still in the ventricle. The left chamber of the device showed a superior washout performance, with a contrast volume still inside the device after four washout cycles of 6.2%, with the right chamber showing 15%.


Asunto(s)
Corazón Artificial , Modelos Cardiovasculares , Diseño de Prótesis , Simulación por Computador , Humanos , Flujo Sanguíneo Regional/fisiología , Volumen Sistólico/fisiología
2.
Catheter Cardiovasc Interv ; 92(5): 897-906, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29516609

RESUMEN

OBJECTIVES: To evaluate the occurrence of rewiring through one of the panels of the Tryton stent (instead of the assumed re-wiring in-between the panels) and the influence on stent geometry and mechanics. BACKGROUND: Tryton is a side branch stent used in combination with a main branch device. It is placed without the need of rotational orientation. However, it is unknown whether main branch re-wiring accidentally may occur through a panel, instead of in-between the panels. METHODS: We used three-dimensional optical coherence tomography to evaluate the location of distal main branch re-wiring through Tryton. Furthermore, we used computer simulations to evaluate the influence on stent geometry and mechanics. RESULTS: Rewiring through a panel (instead of in-between two panels) occurred in 45% of the cases. By using virtual stent deployment, we found minimal differences in ostial side branch stenoses (44.8% in-between the panels and 39.0% through a panel). There were no differences in minimum stent areas of the distal main branch (6.38 mm2 vs. 6.39 mm2 ). In both scenarios, the re-wired Tryton cell was large enough for main branch stenting (expressed as the diameter of the largest possible circle that fits within the cells): 3.40 mm (in-between the panels) vs. 3.02 mm (through a panel). CONCLUSIONS: In 45% of the Tryton implantations, distal main branch rewiring (and subsequent main branch stenting) was performed through one Tryton panel, instead of the assumed rewiring in-between the panels. However, this did not result in unfavorable stent geometries or mechanics, as evaluated with computer simulations.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Modelos Cardiovasculares , Modelación Específica para el Paciente , Stents , Tomografía de Coherencia Óptica , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sistema de Registros , Resultado del Tratamiento
3.
Artif Organs ; 42(11): E380-E390, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30155896

RESUMEN

Clinical observation of condensation at the gas flow exit of blood oxygenators is a recurrent event during cardiopulmonary bypass. These devices consist of a bundle of hollow fibers made of a microporous membrane that allows the exchange of O2 and CO2 . The fibers carry a gas mixture inside (intraluminal flow), while blood flows externally around them (extraluminal flow). Although different studies described this effect in the past, the specific role of the different sections of the device requires further analysis, and the total condensation rate remains unquantified. In this study, a closer look is taken at the transition of gas between the oxygenation bundle and the external room air. A method is proposed to estimate the total condensate output, combining computational fluid dynamics (CFD) of thermal distribution and a simplified 1D model of water vapor saturation of gas. The influence of a number of different parameters is analyzed, regarding material properties, environmental conditions, and clinical use. Results show that condensation rate could vary in a 30-fold range within reasonably small variations of the different variables considered.


Asunto(s)
Regulación de la Temperatura Corporal , Oxigenadores de Membrana , Vapor/análisis , Puente Cardiopulmonar/instrumentación , Simulación por Computador , Diseño de Equipo , Hidrodinámica , Modelos Químicos
4.
Artif Organs ; 42(10): E315-E324, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30298937

RESUMEN

Heart failure is a progressive and often fatal pathology among the main causes of death in the world. An implantable total artificial heart (TAH) is an alternative to heart transplantation. Blood damage quantification is imperative to assess the behavior of an artificial ventricle and is strictly related to the hemodynamics, which can be investigated through numerical simulations. The aim of this study is to develop a computational model that can accurately reproduce the hemodynamics inside the left pumping chamber of an existing TAH (Carmat-TAH) together with the displacement of the leaflets of the biological aortic and mitral valves and the displacement of the pericardium-made membrane. The proposed modeling workflow combines fluid-structure interaction (FSI) simulations based on a fixed grid method with computational fluid dynamics (CFD). In particular, the kinematics of the valves is accounted for by means of a dynamic mesh technique in the CFD. The comparison between FSI- and CFD-calculated velocity fields confirmed that the presence of the valves in the CFD model is essential for realistically mimicking blood dynamics, with a percentage difference of 2% during systole phase and 13% during the diastole. The percentage of blood volume in the CFD simulation with a shear stress above the threshold of 50 Pa is less than 0.001%. In conclusion, the application of this workflow to the Carmat-TAH provided consistent results with previous clinical studies demonstrating its utility in calculating local hemodynamic quantities in the presence of complex moving boundaries.


Asunto(s)
Simulación por Computador , Corazón Artificial/efectos adversos , Hidrodinámica , Modelos Cardiovasculares , Fenómenos Biomecánicos , Diástole , Diseño de Equipo , Corazón Auxiliar/efectos adversos , Hemodinámica , Humanos , Estrés Mecánico
5.
Proc Natl Acad Sci U S A ; 112(1): 214-9, 2015 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-25524628

RESUMEN

A key aspect of cancer metastases is the tendency for specific cancer cells to home to defined subsets of secondary organs. Despite these known tendencies, the underlying mechanisms remain poorly understood. Here we develop a microfluidic 3D in vitro model to analyze organ-specific human breast cancer cell extravasation into bone- and muscle-mimicking microenvironments through a microvascular network concentrically wrapped with mural cells. Extravasation rates and microvasculature permeabilities were significantly different in the bone-mimicking microenvironment compared with unconditioned or myoblast containing matrices. Blocking breast cancer cell A3 adenosine receptors resulted in higher extravasation rates of cancer cells into the myoblast-containing matrices compared with untreated cells, suggesting a role for adenosine in reducing extravasation. These results demonstrate the efficacy of our model as a drug screening platform and a promising tool to investigate specific molecular pathways involved in cancer biology, with potential applications to personalized medicine.


Asunto(s)
Neoplasias de la Mama/irrigación sanguínea , Neoplasias de la Mama/patología , Extravasación de Materiales Terapéuticos y Diagnósticos/diagnóstico , Microfluídica/métodos , Microvasos/patología , Adenosina/metabolismo , Animales , Permeabilidad Capilar , Línea Celular Tumoral , Microambiente Celular , Femenino , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Humanos , Ratones , Resistencia al Corte , Estrés Mecánico
6.
Artif Organs ; 38(10): 845-55, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24571089

RESUMEN

According to a number of clinical studies, coronary aspiration catheters are useful tools to remove a thrombus (blood clot) blocking a coronary artery. However, these thrombectomy devices may fail to remove the blood clot entirely. Few studies have been devoted to a systematic analysis of factors affecting clot aspiration. The geometric characteristics of the aspiration catheter, the physical properties of the thrombus, and the applied vacuum pressure are crucial parameters. In this study, the aspiration of a blood clot blocking a coronary bifurcation is computationally simulated. The clot is modeled as a highly viscous fluid, and a two-phase (blood and clot) problem is solved. The effects of geometric variations in the tip of the coronary catheter, including lateral hole size and location, are investigated considering different aspiration pressures and clot viscosities. A Bird-Carreau model is adopted for blood viscosity, while a power law model is used to describe the clot rheology. Computational results for blood clot aspiration show that the presence of holes in the lateral part of the tip of the catheter can be beneficial depending on clot viscosity, hole features, and applied aspiration pressure. In general, the holes are beneficial when the clot viscosity is low, while aspiration catheters without any extra lateral holes exhibit better performance for higher clot viscosity. However, when higher aspiration pressures are applied, the catheters tend to behave relatively similarly in removing clots with various viscosities, reducing the role of the clot viscosity.


Asunto(s)
Catéteres , Simulación por Computador , Trombosis Coronaria/cirugía , Diseño de Equipo , Modelos Cardiovasculares , Trombectomía/instrumentación , Humanos , Succión/instrumentación
7.
Comput Methods Programs Biomed ; 254: 108271, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38878362

RESUMEN

BACKGROUND AND OBJECTIVE: Coronary plaque rupture is a precipitating event responsible for two thirds of myocardial infarctions. Currently, the risk of plaque rupture is computed based on demographic, clinical, and image-based adverse features. However, using these features the absolute event rate per single higher-risk lesion remains low. This work studies the power of a novel framework based on biomechanical markers accounting for material uncertainty to stratify vulnerable and non-vulnerable coronary plaques. METHODS: Virtual histology intravascular ultrasounds from 55 patients, 29 affected by acute coronary syndrome and 26 affected by stable angina pectoris, were included in this study. Two-dimensional vessel cross-sections for finite element modeling (10 sections per plaque) incorporating plaque structure (medial tissue, loose matrix, lipid core and calcification) were reconstructed. A Montecarlo finite element analysis was performed on each section to account for material variability on three biomechanical markers: peak plaque structural stress at diastolic and systolic pressure, and peak plaque stress difference between systolic and diastolic pressures, together with the luminal pressure. Machine learning decision tree classifiers were trained on 75% of the dataset and tested on the remaining 25% with a combination of feature selection techniques. Performance against classification trees based on geometric markers (i.e., luminal, external elastic membrane and plaque areas) was also performed. RESULTS: Our results indicate that the plaque structural stress outperforms the classification capacity of the combined geometric markers only (0.82 vs 0.51 area under curve) when accounting for uncertainty in material parameters. Furthermore, the results suggest that the combination of the peak plaque structural stress at diastolic and systolic pressures with the maximum plaque structural stress difference between systolic and diastolic pressures together with the systolic pressure and the diastolic to systolic pressure gradient is a robust classifier for coronary plaques when the intrinsic variability in material parameters is considered (area under curve equal to [0.91-0.93]). CONCLUSION: In summary, our results emphasize that peak plaque structural stress in combination with the patient's luminal pressure is a potential classifier of plaque vulnerability as it independently considers stress in all directions and incorporates total geometric and compositional features of atherosclerotic plaques.

8.
Mater Today Bio ; 26: 101072, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38757057

RESUMEN

Osteoarthritis (OA) is a highly disabling pathology, characterized by synovial inflammation and cartilage degeneration. Orthobiologics have shown promising results in OA treatment thanks to their ability to influence articular cells and modulate the inflammatory OA environment. Considering their complex mechanism of action, the development of reliable and relevant joint models appears as crucial to select the best orthobiologics for each patient. The aim of this study was to establish a microfluidic OA model to test therapies in a personalized human setting. The joint-on-a-chip model included cartilage and synovial compartments, containing hydrogel-embedded chondrocytes and synovial fibroblasts, separated by a channel for synovial fluid. For the cartilage compartment, a Hyaluronic Acid-based matrix was selected to preserve chondrocyte phenotype. Adding OA synovial fluid induced the production of inflammatory cytokines and degradative enzymes, generating an OA microenvironment. Personalized models were generated using patient-matched cells and synovial fluid to test the efficacy of mesenchymal stem cells on OA signatures. The patient-specific models allowed monitoring changes induced by cell injection, highlighting different individual responses to the treatment. Altogether, these results support the use of this joint-on-a-chip model as a prognostic tool to screen the patient-specific efficacy of orthobiologics.

9.
Nephrol Dial Transplant ; 28(4): 997-1005, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22785110

RESUMEN

BACKGROUND: Early failure of the vascular access for haemodialysis (HD) after the surgical creation of a radial-cephalic arteriovenous fistula (AVF) occurs mainly due to a juxta-anastomotic stenosis. Even if elevated blood flow induces high wall shear stress, we have recently shown that disturbed flow, characterized by low and reciprocating flow, may develop in zones of the AVF where it can provide a good indication of the sites of future stenoses. The present study was aimed at investigating whether the anastomosis angle influences disturbed flow in radial-cephalic 'side-to-end' AVF. METHODS: By means of a parametric AVF model we created four equivalent meshes with anastomosis angles of 30°, 45°, 60° and 90°, respectively. We then performed transient, non-Newtonian computational fluid dynamics simulations using, as boundary conditions, previously measured blood volume flow and division ratio in subjects requiring primary access. The relative residence time (RRT), a robust indicator of disturbed flow, was calculated for the overall wall surface and disturbed flow was localized as areas having RRT > 1. Quantitative characterization and statistical tests were employed to assess the difference in RRT medians between the four anastomosis angle cases. RESULTS: Disturbed flow was located in all AVF models in the same areas where flow recirculation and stagnation occurred, on the inner wall of the swing segment (SS) and on the arterial wall at the anastomosis floor (AF). A smaller angle AVF had smaller disturbed flow areas with lower RRT peak values, either on the venous or the arterial limb. There were significant differences in the RRT medians on the SS and on the AF between sharper (30° and 45°) and wider (60° or 90°) angles. CONCLUSIONS: We have found that in 'side-to-end' radial-cephalic AVFs for HD, the anastomosis angle does impact on the local disturbed flow patterns. Among the four geometries we considered in this study, the smaller angle (30°) would be the preferred choice that minimizes the development of neointima. Clinicians should consider this at the time of AVF creation because the anastomosis angle is in part amenable to surgical manipulation.


Asunto(s)
Anastomosis Quirúrgica , Fístula Arteriovenosa/cirugía , Derivación Arteriovenosa Quirúrgica , Hemodinámica , Modelos Cardiovasculares , Diálisis Renal , Fístula Arteriovenosa/fisiopatología , Velocidad del Flujo Sanguíneo , Simulación por Computador , Constricción Patológica , Humanos , Pronóstico
10.
Comput Methods Programs Biomed ; 234: 107515, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37011425

RESUMEN

BACKGROUND AND OBJECTIVE: Mechanical thrombectomy is a minimally invasive procedure that aims at removing the occluding thrombus from the vasculature of acute ischemic stroke patients. Thrombectomy success and failure can be studied using in-silico thrombectomy models. Such models require realistic modeling steps to be effective. We here present a new approach to model microcatheter tracking during thrombectomy. METHODS: For 3 patient-specific vessel geometries, we performed finite-element simulations of the microcatheter tracking (1) following the vessel centerline (centerline method) and (2) as a one-step insertion simulation, where the microcatheter tip was advanced along the vessel centerline while its body was free to interact with the vessel wall (tip-dragging method). Qualitative validation of the two tracking methods was performed with the patient's digital subtraction angiography (DSA) images. In addition, we compared simulated thrombectomy outcomes (successful vs unsuccessful thrombus retrieval) and maximum principal stresses on the thrombus between the centerline and tip-dragging method. RESULTS: Qualitative comparison with the DSA images showed that the tip-dragging method more realistically resembles the patient-specific microcatheter-tracking scenario, where the microcatheter approaches the vessel walls. Although the simulated thrombectomy outcomes were similar in terms of thrombus retrieval, the thrombus stress fields (and the associated fragmentation of the thrombus) were strongly different between the two methods, with local differences in the maximum principal stress curves up to 84%. CONCLUSIONS: Microcatheter positioning with respect to the vessel affects the stress fields of the thrombus during retrieval, and therefore, may influence thrombus fragmentation and retrieval in-silico thrombectomy.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Trombosis , Humanos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Trombosis/diagnóstico por imagen , Trombosis/cirugía , Simulación por Computador , Resultado del Tratamiento
11.
JACC Cardiovasc Interv ; 16(20): 2479-2497, 2023 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-37879802

RESUMEN

Artificial intelligence, computational simulations, and extended reality, among other 21st century computational technologies, are changing the health care system. To collectively highlight the most recent advances and benefits of artificial intelligence, computational simulations, and extended reality in cardiovascular therapies, we coined the abbreviation AISER. The review particularly focuses on the following applications of AISER: 1) preprocedural planning and clinical decision making; 2) virtual clinical trials, and cardiovascular device research, development, and regulatory approval; and 3) education and training of interventional health care professionals and medical technology innovators. We also discuss the obstacles and constraints associated with the application of AISER technologies, as well as the proposed solutions. Interventional health care professionals, computer scientists, biomedical engineers, experts in bioinformatics and visualization, the device industry, ethics committees, and regulatory agencies are expected to streamline the use of AISER technologies in cardiovascular interventions and medicine in general.


Asunto(s)
Inteligencia Artificial , Humanos , Resultado del Tratamiento
12.
Circulation ; 124(11 Suppl): S204-10, 2011 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-21911814

RESUMEN

BACKGROUND: Combining bilateral pulmonary artery banding with arterial duct stenting, the hybrid approach achieves stage 1 palliation for hypoplastic left heart syndrome with different flow characteristics than those after the surgical Norwood procedures. Accordingly, we used computational modeling to assess some of these differences, including influence on systemic and cerebral oxygen deliveries. METHODS AND RESULTS: A 3-dimensional computational model of hybrid palliation was developed by the finite volume method, along with models of the Norwood operation with a modified Blalock-Tausig or right ventricle-to-pulmonary artery shunt. Hybrid circulation was modeled with a 7-mm ductal stent and bilateral pulmonary artery banding to a 2-mm diameter. A 3.5-mm conduit was used in the Blalock-Tausig shunt model, whereas a 5-mm conduit was used in the right ventricle-to-pulmonary artery shunt model. Coupled to all the models was an identical hydraulic network that described the entire circulatory system based on pre-stage 2 hemodynamics. This clinically validated multiscale approach predicts flow dynamics, as well as global cardiac output, mixed venous oxygen saturation, and systemic and cerebral oxygen delivery. Compared with either of the Norwood models, the hybrid palliation had higher pulmonary-to-systemic flow ratio and lower cardiac output. Total systemic oxygen delivery was markedly reduced in the hybrid palliation (Blalock-Tausig shunt 591, right ventricle-to-pulmonary artery shunt 640, and hybrid 475 mL · min(-1) · m(-2)). Cerebral oxygen delivery was similarly lower in the hybrid palliation. CONCLUSIONS: These computational results suggest that the hybrid approach may provide inferior systemic and cerebral oxygen deliveries compared with either of the 2 surgical Norwood procedures before stage 2 palliation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Modelos Teóricos , Procedimientos de Norwood/métodos , Cuidados Paliativos/métodos , Arteria Pulmonar/fisiopatología , Stents , Circulación Cerebrovascular/fisiología , Ventrículos Cardíacos/cirugía , Hemodinámica/fisiología , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/fisiopatología , Oxígeno/sangre , Valor Predictivo de las Pruebas , Arteria Pulmonar/cirugía , Resultado del Tratamiento
13.
Biomicrofluidics ; 16(3): 031501, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35646223

RESUMEN

Drug discovery is an expensive and lengthy process. Among the different phases, drug discovery and preclinical trials play an important role as only 5-10 of all drugs that begin preclinical tests proceed to clinical trials. Indeed, current high-throughput screening technologies are very expensive, as they are unable to dispense small liquid volumes in an accurate and quick way. Moreover, despite being simple and fast, drug screening assays are usually performed under static conditions, thus failing to recapitulate tissue-specific architecture and biomechanical cues present in vivo even in the case of 3D models. On the contrary, microfluidics might offer a more rapid and cost-effective alternative. Although considered incompatible with high-throughput systems for years, technological advancements have demonstrated how this gap is rapidly reducing. In this Review, we want to further outline the role of microfluidics in high-throughput drug screening applications by looking at the multiple strategies for cell seeding, compartmentalization, continuous flow, stimuli administration (e.g., drug gradients or shear stresses), and single-cell analyses.

14.
Front Bioeng Biotechnol ; 10: 918690, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36061430

RESUMEN

3D-Bioprinting leads to the realization of tridimensional customized constructs to reproduce the biological structural complexity. The new technological challenge focuses on obtaining a 3D structure with several distinct layers to replicate the hierarchical organization of natural tissues. This work aims to reproduce large blood vessel substitutes compliant with the original tissue, combining the advantages of the 3D bioprinting, decellularization, and accounting for the presence of different cells. The decellularization process was performed on porcine aortas. Various decellularization protocols were tested and evaluated through DNA extraction, quantification, and amplification by PCR to define the adequate one. The decellularized extracellular matrix (dECM), lyophilized and solubilized, was combined with gelatin, alginate, and cells to obtain a novel bioink. Several solutions were tested, tuning the percentage of the components to obtain the adequate structural properties. The geometrical model of the large blood vessel constructs was designed with SolidWorks, and the construct slicing was done using the HeartWare software, which allowed generating the G-Code. The final constructs were 3D bioprinted with the Inkredible + using dual print heads. The composition of the bioink was tuned so that it could withstand the printing of a segment of a tubular construct up to 10 mm and reproduce the multicellular complexity. Among the several compositions tested, the suspension resulting from 8% w/v gelatin, 7% w/v alginate, and 3% w/v dECM, and cells successfully produced the designed structures. With this bioink, it was possible to print structures made up of 20 layers. The dimensions of the printed structures were consistent with the designed ones. We were able to avoid the double bioink overlap in the thickness, despite the increase in the number of layers during the printing process. The optimization of the parameters allowed the production of structures with a height of 20 layers corresponding to 9 mm. Theoretical and real structures were very close. The differences were 14% in height, 20% internal diameter, and 9% thickness. By tailoring the printing parameters and the amount of dECM, adequate mechanical properties could be met. In this study, we developed an innovative printable bioink able to finely reproduce the native complex structure of the large blood vessel.

15.
J Mech Behav Biomed Mater ; 135: 105462, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36116343

RESUMEN

Mechanical thrombectomy (MT) treatment of acute ischemic stroke (AIS) patients typically involves use of stent retrievers or aspiration catheters alone or in combination. For in silico trials of AIS patients, it is crucial to incorporate the possibility of thrombus fragmentation during the intervention. This study focuses on two aspects of the thrombectomy simulation: i) Thrombus fragmentation on the basis of a failure model calibrated with experimental tests on clot analogs; ii) the combined stent-retriever and aspiration catheter MT procedure is modeled by adding both the proximal balloon guide catheter and the distal access catheter. The adopted failure criterion is based on maximum principal stress threshold value. If elements of the thrombus exceed this criterion during the retrieval simulation, then they are deleted from the calculation. Comparison with in-vitro tests indicates that the simulation correctly reproduces the procedures predicting thrombus fragmentation in the case of red blood cells rich thrombi, whereas non-fragmentation is predicted for fibrin-rich thrombi. Modeling of balloon guide catheter prevents clot fragments' embolization to further distal territories during MT procedure.


Asunto(s)
Accidente Cerebrovascular Isquémico , Trombosis , Fibrina , Humanos , Stents , Trombectomía/efectos adversos , Trombectomía/métodos , Trombosis/terapia , Resultado del Tratamiento
16.
PLoS One ; 17(7): e0271469, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35901129

RESUMEN

AIMS: Coronary artery stents have profound effects on arterial function by altering fluid flow mass transport and wall shear stress. We developed a new integrated methodology to analyse the effects of stents on mass transport and shear stress to inform the design of haemodynamically-favourable stents. METHODS AND RESULTS: Stents were deployed in model vessels followed by tracking of fluorescent particles under flow. Parallel analyses involved high-resolution micro-computed tomography scanning followed by computational fluid dynamics simulations to assess wall shear stress distribution. Several stent designs were analysed to assess whether the workflow was robust for diverse strut geometries. Stents had striking effects on fluid flow streamlines, flow separation or funnelling, and the accumulation of particles at areas of complex geometry that were tightly coupled to stent shape. CFD analysis revealed that stents had a major influence on wall shear stress magnitude, direction and distribution and this was highly sensitive to geometry. CONCLUSIONS: Integration of particle tracking with CFD allows assessment of fluid flow and shear stress in stented arteries in unprecedented detail. Deleterious flow perturbations, such as accumulation of particles at struts and non-physiological shear stress, were highly sensitive to individual stent geometry. Novel designs for stents should be tested for mass transport and shear stress which are important effectors of vascular health and repair.


Asunto(s)
Hidrodinámica , Modelos Cardiovasculares , Prótesis Vascular , Simulación por Computador , Vasos Coronarios , Hemodinámica , Stents , Estrés Mecánico , Microtomografía por Rayos X
17.
J Biomech Eng ; 133(12): 121010, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22206427

RESUMEN

Despite their success, stenting procedures are still associated to some clinical problems like sub-acute thrombosis and in-stent restenosis. Several clinical studies associate these phenomena to a combination of both structural and hemodynamic alterations caused by stent implantation. Recently, numerical models have been widely used in the literature to investigate stenting procedures but always from either a purely structural or fluid dynamic point of view. The aim of this work is the implementation of sequential structural and fluid dynamic numerical models to provide a better understanding of stenting procedures in coronary bifurcations. In particular, the realistic geometrical configurations obtained with structural simulations were used to create the fluid domains employed within transient fluid dynamic analyses. This sequential approach was applied to investigate the final kissing balloon (FKB) inflation during the provisional side branch technique. Mechanical stresses in the arterial wall and the stent as well as wall shear stresses along the arterial wall were examined before and after the FKB deployment. FKB provoked average mechanical stresses in the arterial wall almost 2.5 times higher with respect to those induced by inflation of the stent in the main branch only. Results also enlightened FKB benefits in terms of improved local blood flow pattern for the side branch access. As a drawback, the FKB generates a larger region of low wall shear stress. In particular, after FKB the percentage of area characterized by wall shear stresses lower than 0.5 Pa was 79.0%, while before the FKB it was 62.3%. For these reasons, a new tapered balloon dedicated to bifurcations was proposed. The inclusion of the modified balloon has reduced the mechanical stresses in the proximal arterial vessel to 40% and the low wall shear stress coverage area to 71.3%. In conclusion, these results show the relevance of the adopted sequential approach to study the wall mechanics and the hemodynamics created by stent deployment.


Asunto(s)
Vasos Coronarios/anatomía & histología , Vasos Coronarios/fisiología , Hidrodinámica , Modelos Anatómicos , Modelos Biológicos , Stents , Fenómenos Biomecánicos , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/fisiopatología
18.
J Appl Biomater Biomech ; 9(2): 109-17, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22065388

RESUMEN

Over the last twenty years major advancements have taken place in the design of medical devices and personalized therapies. They have paralleled the impressive evolution of three-dimensional, non invasive, medical imaging techniques and have been continuously fuelled by increasing computing power and the emergence of novel and sophisticated software tools. This paper aims to showcase a number of major contributions to the advancements of modeling of surgical and interventional procedures and to the design of life support systems. The selected examples will span from pediatric cardiac surgery procedures to valve and ventricle repair techniques, from stent design and endovascular procedures to life support systems and innovative ventilation techniques.


Asunto(s)
Ingeniería Biomédica/métodos , Ingeniería Biomédica/tendencias , Sistemas de Manutención de la Vida/instrumentación , Modelos Cardiovasculares , Adolescente , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/tendencias , Niño , Preescolar , Humanos , Imagenología Tridimensional/métodos , Imagenología Tridimensional/tendencias , Lactante , Programas Informáticos/tendencias
19.
Sci Rep ; 11(1): 1109, 2021 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-33441807

RESUMEN

Aerosol and pollutants, in form of particulates 5-8 µm in main size face every day our respiratory system as natural suspension in air or forced to be inhaled as a coadjutant in a medical therapy for respiratory diseases. This inhalation happens in children to elderly, women and men, healthy or sick and disable people. In this paper we analyzed the inhalation of aerosol in conditions assimilable to the thermal therapy. We use a computational fluid dynamic 3D model to compute and visualize the trajectories of aerosol (3-7-10-25 µm) down to the sixth generation of bronchi, in a steady and dynamic condition (7 µm) set as breath cycle at rest. Results, compared to a set of milestone experimental studies published in literature, allow the comprehension of particles behavior during the inhalation from mouth to bronchi sixth generation, the visualization of jet at larynx constriction and vortices, in an averaged characteristic rigorous geometrical model including tracheal rings. Results on trajectories and deposition show the importance of the including transient physiological breath cycle on aerosol deposition analyses. Numerical and graphical results, may enable the design of medical devices and protocols to make the inhalations more effective in all the users' population.


Asunto(s)
Aerosoles , Bronquios/fisiología , Simulación por Computador , Modelos Biológicos , Administración por Inhalación , Adulto , Humanos , Hidrodinámica , Masculino , Tamaño de la Partícula , Ventilación Pulmonar , Tráquea/fisiología
20.
Expert Rev Cardiovasc Ther ; 19(10): 907-916, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34704881

RESUMEN

INTRODUCTION: The increased survival rate of patients with congenital heart disease (CHD) has made it likely that 70%-95% of infants with CHDs surviving into adulthood often require careful follow-up and (repeat) interventions. Patients with CHDs often have abnormal blood flow patterns, due to both primary cardiac defect and the consequent surgical or endovascular repair. AREA COVERED: Computational fluid dynamics (CFD) alone or coupled with advanced imaging tools can assess blood flow patterns of CHDs to both understand their pathophysiology and anticipate the results of surgical or interventional repair. EXPERT OPINION: CFD is a mathematical technique that quantifies and describes the characteristics of fluid flow using the laws of physics. Through dedicated software based on virtual reconstruction and simulation and patients' real data coming from computed tomography, magnetic resonance imaging, and 3/4 D-ultrasound, reconstruction of models of circulation of most CHD can be accomplished. CFD can provide insights about the pathophysiology of coronary artery anomalies, interatrial shunts, coarctation of the aorta and aortic bicuspid valve, tetralogy of Fallot and univentricular heart, with the capability in some cases of simulating different types of surgical or interventional repair and tailoring the treatment on the basis of these findings.


Asunto(s)
Cardiopatías Congénitas , Hidrodinámica , Adulto , Cardiopatías Congénitas/diagnóstico por imagen , Hemodinámica , Humanos , Lactante , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA