Ultrasound Med Biol ; 49(1): 269-277, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36441031

RESUMEN

High-intensity focused ultrasound (HIFU) transducer acoustic output can vary over time as a result of an inconsistent power supply, damage to the transducer or deterioration over time. Therefore, easy implementation of a daily quality assurance (DQA) method is of great importance for pre-clinical research and clinical applications. We present here a thermochromic material-based phantom validated by thermal simulations and found to provide repeatable visual power output assessments in fewer than 15 s that are accurate to within 10%. Whereas current available methods such as radiation force balance measurements provide an estimate of the total acoustic power, we explain here that the thermochromic phantom is sensitive to the shape of the acoustic field at focus by changing the aperture of a multi-element transducer with a fixed acoustic power. The proposed phantom allows the end user to visually assess the transducer's functionality without resorting to expensive, time-consuming hydrophone measurements or image analysis.


Asunto(s)
Terapia por Ultrasonido , Fantasmas de Imagen , Transductores , Acústica , Procesamiento de Imagen Asistido por Computador
2.
Ultrasound Med Biol ; 48(1): 157-163, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34702638

RESUMEN

The Focused Ultrasound Foundation has developed a low-cost, validated, open-source hydrophone scanner for the spatial characterization of ultrasound transducers. Assembly instructions and a MATLAB control graphical user interface are provided such that the device can be easily replicated for less than $1000 in roughly 40 person-hours. The low-cost scanning tank's performance was compared with data collected with a commercial automated scanning tank. Pressure measurements of a focused transducer and a planar transducer had less than a 10% difference between the two scanning systems. Two-dimensional automated scans (20 × 20 mm at 0.25-mm resolution) took the low-cost scanning tank 45 min compared with the commercial system's 30 min. A reproducibility study found that the low-cost scanner made consistent peak negative pressure measurements as reflected by the low coefficient of variation for both focused (1.88%) and planar (0.98%) transducers. The low-cost scanner described here is a viable alternative for ultrasound laboratories needing efficient, accurate characterization of ultrasound transducers.


Asunto(s)
Acústica , Ultrasonido , Reproducibilidad de los Resultados , Transductores
3.
Tomography ; 8(5): 2232-2242, 2022 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-36136883

RESUMEN

A combination of surgery and chemotherapy is the most effective treatment available for Malignant Pleural Mesothelioma (MPM). However, both cause significant collateral damage and cannot eliminate residual microscopic disease. This investigation aimed to compare and determine the feasibility of utilizing Radiofrequency Ablation (RFA) and Magnetic-Resonance-guided Focused Ultrasound Surgery (MRgFUS) as alternative treatments for MPM. A large animal tumor model was developed in 13 Yorkshire female pigs using the MSTO211H cell line. Two pigs were initially used to determine the cyclosporine dose required for immunosuppression and tumor development. Subsequently, 11 other pigs underwent tumor development. Of these 11, 2 died during cell inoculation. Small tumor masses and adhesions were present in the other 9, indicating mesothelioma development. Five pigs then received RFA treatment, and 4 pigs received MRgFUS treatment. Tumor model development and effect of the two treatments were examined using MRI and by necropsy. RFA and MRgFUS both successfully ablated approximately the same sized area in the same treatment time. This study demonstrates that RFA and MRgFUS are feasible for tumor debulking, and while MRgFUS requires more pretreatment planning compared to RFA, MRgFUS is a completely noninvasive procedure.


Asunto(s)
Ablación por Catéter , Ciclosporinas , Imagen por Resonancia Magnética Intervencional , Mesotelioma Maligno , Animales , Procedimientos Quirúrgicos de Citorreducción , Femenino , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética Intervencional/métodos , Porcinos
4.
Structure ; 15(11): 1442-51, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17997970

RESUMEN

Genome-wide studies in Saccharomyces cerevisiae concluded that the dominant determinant of protein evolutionary rates is expression level: highly expressed proteins generally evolve most slowly. To determine how this constraint affects the evolution of protein interactions, we directly measure evolutionary rates of protein interface, surface, and core residues by structurally mapping domain interactions to yeast genomes. We find that mRNA level and protein abundance, though correlated, report on pressures affecting regions of proteins differently. Pressures proportional to mRNA level slow evolutionary rates of all structural regions and reduce the variability in rate differences between interfaces and other surfaces. In contrast, the evolutionary rate variation within a domain is much less correlated to protein abundance. Distinct pressures may be associated primarily with the cost (mRNA level) and functional (protein abundance) benefit of protein production. Interfaces of proteins with low mRNA levels may have higher evolutionary flexibility and could constitute the raw material for new functions.


Asunto(s)
Evolución Molecular , ARN Mensajero/metabolismo , Proteínas de Saccharomyces cerevisiae/química , Proteínas de Saccharomyces cerevisiae/metabolismo , Sitios de Unión , Genoma Fúngico , Conformación Proteica , ARN Mensajero/genética , Saccharomyces cerevisiae/genética , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/genética
5.
J Neurosurg ; 122(1): 152-61, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25380106

RESUMEN

OBJECT: In biological tissues, it is known that the creation of gas bubbles (cavitation) during ultrasound exposure is more likely to occur at lower rather than higher frequencies. Upon collapsing, such bubbles can induce hemorrhage. Thus, acoustic inertial cavitation secondary to a 220-kHz MRI-guided focused ultrasound (MRgFUS) surgery is a serious safety issue, and animal studies are mandatory for laying the groundwork for the use of low-frequency systems in future clinical trials. The authors investigate here the in vivo potential thresholds of MRgFUS-induced inertial cavitation and MRgFUS-induced thermal coagulation using MRI, acoustic spectroscopy, and histology. METHODS: Ten female piglets that had undergone a craniectomy were sonicated using a 220-kHz transcranial MRgFUS system over an acoustic energy range of 5600-14,000 J. For each piglet, a long-duration sonication (40-second duration) was performed on the right thalamus, and a short sonication (20-second duration) was performed on the left thalamus. An acoustic power range of 140-300 W was used for long-duration sonications and 300-700 W for short-duration sonications. Signals collected by 2 passive cavitation detectors were stored in memory during each sonication, and any subsequent cavitation activity was integrated within the bandwidth of the detectors. Real-time 2D MR thermometry was performed during the sonications. T1-weighted, T2-weighted, gradient-recalled echo, and diffusion-weighted imaging MRI was performed after treatment to assess the lesions. The piglets were killed immediately after the last series of posttreatment MR images were obtained. Their brains were harvested, and histological examinations were then performed to further evaluate the lesions. RESULTS: Two types of lesions were induced: thermal ablation lesions, as evidenced by an acute ischemic infarction on MRI and histology, and hemorrhagic lesions, associated with inertial cavitation. Passive cavitation signals exhibited 3 main patterns identified as follows: no cavitation, stable cavitation, and inertial cavitation. Low-power and longer sonications induced only thermal lesions, with a peak temperature threshold for lesioning of 53°C. Hemorrhagic lesions occurred only with high-power and shorter sonications. The sizes of the hemorrhages measured on macroscopic histological examinations correlated with the intensity of the cavitation activity (R2 = 0.74). The acoustic cavitation activity detected by the passive cavitation detectors exhibited a threshold of 0.09 V·Hz for the occurrence of hemorrhages. CONCLUSIONS: This work demonstrates that 220-kHz ultrasound is capable of inducing a thermal lesion in the brain of living swines without hemorrhage. Although the same acoustic energy can induce either a hemorrhage or a thermal lesion, it seems that low-power, long-duration sonication is less likely to cause hemorrhage and may be safer. Although further study is needed to decrease the likelihood of ischemic infarction associated with the 220-kHz ultrasound, the threshold established in this work may allow for the detection and prevention of deleterious cavitations.


Asunto(s)
Procedimientos Neuroquirúrgicos/métodos , Cirugía Asistida por Computador/métodos , Procedimientos Quirúrgicos Ultrasónicos/métodos , Animales , Femenino , Hemorragias Intracraneales/etiología , Imagen por Resonancia Magnética , Porcinos , Tálamo/cirugía
6.
Phys Med Biol ; 59(13): 3599-614, 2014 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-24909357

RESUMEN

Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called 'virtual CT' to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland-Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (-0.22-0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the maximum temperature elevation in the phantom (7% relative drop). Without any correction, the maximum temperature was down 6 °C (43% relative drop). We have developed an approach that allows for a reconstruction of a virtual CT dataset from MRI to perform phase correction in TcMRgFUS.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Terapia por Ultrasonido/métodos , Encéfalo/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Cráneo/anatomía & histología , Cráneo/diagnóstico por imagen
7.
J Neuroimaging ; 23(2): 187-91, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22082153

RESUMEN

BACKGROUND AND PURPOSE: As magnetic resonance-guided focused ultrasound (MRgFUS) sonothrombolysis relies on mechanical rather than thermal mechanisms to achieve clot lysis, thermometry is not useful for the intraoperative monitoring of clot breakdown by MRgFUS. Therefore, the purpose of this study was to evaluate the optimum imaging sequence for sonothrombolysis. METHODS: In vitro blood drawn from 6 healthy volunteers was imaged using T1, T2 spin-echo, and T2 gradient-echo (GRE) sequences both before and after sonication using an Insightec ExAblate 4000 FUS transducer. Signal intensities of the three MR imaging sequences were measured and normalized to background signal for each time point. Representative samples of the pre- and postsonication clot were also sent to pathology for hematologic analysis. RESULTS: After sonication, the clot in the treatment tube was fully lysed as evidenced by physical and hematologic evaluation. The difference between pre- and postsonicated normalized signal intensity ratios demonstrated statistical significance only on T2 and GRE sequences (P < .001). However, significant blooming artifact limited interpretation on all GRE images. CONCLUSION: T2 is the most appropriate sequence for the evaluation of mechanical MRgFUS sonothrombolysis of an in vitro clot. These findings are consistent across the oxidative states of clot up to 48 hours.


Asunto(s)
Coagulación Sanguínea/efectos de la radiación , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Trombolisis Mecánica/métodos , Cirugía Asistida por Computador/métodos , Algoritmos , Sangre/efectos de la radiación , Humanos , Almacenamiento y Recuperación de la Información/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
8.
J Ther Ultrasound ; 1: 13, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-25512859

RESUMEN

Clinical use of high-intensity focused ultrasound (HIFU) under ultrasound or MR guidance as a non-invasive method for treating tumors is rapidly increasing. Tens of thousands of patients have been treated for uterine fibroid, benign prostate hyperplasia, bone metastases, or prostate cancer. Despite the methods' clinical potential, the liver is a particularly challenging organ for HIFU treatment due to the combined effect of respiratory-induced liver motion, partial blocking by the rib cage, and high perfusion/flow. Several technical and clinical solutions have been developed by various groups during the past 15 years to compensate for these problems. A review of current unmet clinical needs is given here, as well as a consensus from a panel of experts about technical and clinical requirements for upcoming pilot and pivotal studies in order to accelerate the development and adoption of focused ultrasound for the treatment of primary and secondary liver cancer.

9.
Science ; 336(6083): 911-5, 2012 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-22605776

RESUMEN

Cells must balance the cost and benefit of protein expression to optimize organismal fitness. The lac operon of the bacterium Escherichia coli has been a model for quantifying the physiological impact of costly protein production and for elucidating the resulting regulatory mechanisms. We report quantitative fitness measurements in 27 redesigned operons that suggested that protein production is not the primary origin of fitness costs. Instead, we discovered that the lac permease activity, which relates linearly to cost, is the major physiological burden to the cell. These findings explain control points in the lac operon that minimize the cost of lac permease activity, not protein expression. Characterizing similar relationships in other systems will be important to map the impact of cost/benefit tradeoffs on cell physiology and regulation.


Asunto(s)
Proteínas de Escherichia coli/genética , Proteínas de Escherichia coli/metabolismo , Escherichia coli/genética , Operón Lac , Proteínas de Transporte de Monosacáridos/genética , Proteínas de Transporte de Monosacáridos/metabolismo , Simportadores/genética , Simportadores/metabolismo , beta-Galactosidasa/genética , beta-Galactosidasa/metabolismo , Secuencia de Bases , Biocatálisis , Transporte Biológico , Escherichia coli/crecimiento & desarrollo , Escherichia coli/metabolismo , Regulación Bacteriana de la Expresión Génica , Técnicas de Inactivación de Genes , Ingeniería Genética , Isopropil Tiogalactósido/metabolismo , Represoras Lac , Lactosa/metabolismo , Modelos Biológicos , Datos de Secuencia Molecular , Mutación