Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Ann Vasc Surg ; 68: 570.e1-570.e4, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32339676

RESUMEN

Spinal cord ischemia (SCI) is a rare presenting symptom of acute complicated type B aortic dissection, occurring in approximately 3% of patients . We present a case report of a patient with this presentation who had observed resolution of his paraplegia symptoms immediately after placement of a thoracic stent graft under local anesthesia. The temporal association between true lumen flow restoration and paraplegia resolution intraoperatively is a novel finding. We feel that this case report may provide support for recognized cord perfusion theory , as well as contribute to the understanding of the time frame associated with SCI and reversibility of paraplegia.


Asunto(s)
Anestesia Local , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Extremidad Inferior/inervación , Paraplejía/etiología , Isquemia de la Médula Espinal/etiología , Enfermedad Aguda , Anciano , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Humanos , Masculino , Paraplejía/diagnóstico , Paraplejía/fisiopatología , Recuperación de la Función , Isquemia de la Médula Espinal/diagnóstico , Isquemia de la Médula Espinal/fisiopatología , Resultado del Tratamiento
2.
J Vasc Surg ; 70(1): 92-101.e1, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30611580

RESUMEN

BACKGROUND: Endovascular aneurysm repair (EVAR) is an accepted approach for patients presenting with ruptured abdominal aortic aneurysm (rAAA) and suitable anatomy. The effect of anesthesia modality on mortality outcomes in rAAA has not been well described. Using the Vascular Quality Initiative database, this study compares local anesthesia (LA) vs general anesthesia (GA) in EVAR for rAAA. METHODS: The Vascular Quality Initiative database was queried for patients presenting with rAAA managed with open surgical repair, EVAR under LA (rEVAR-LA), and EVAR under GA (rEVAR-GA) between 2003 and 2017. Patients were observed until the earlier end point of either death or 1-year follow-up. Kaplan-Meier event rates are presented at 30 days and 1 year. Cox proportional hazards regression was used to model risk of death, with adjustment for demographic and clinical factors. Additional multivariate Cox hazards analyses were used to assess effect modifiers for 1-year mortality for the different repair methods. RESULTS: A total of 3330 patients (77.4% male) met the inclusion criteria (1594 [47.9%] open surgical repair, 226 [6.8%] rEVAR-LA, and 1510 [45.3%] rEVAR-GA). Patients treated with rEVAR-LA compared with rEVAR-GA had decreased intraoperative time, number of intraoperative blood transfusions, intraoperative crystalloid administration, intensive care unit length of stay, and postoperative pulmonary complications. Mortality rates with rEVAR-LA were lower compared with rEVAR-GA at 30 days (15.5% vs 23.3%; adjusted hazard ratio [AHR], 0.70; 95% confidence interval [CI], 0.49-0.99; P = .04) and at 1 year (22.5% vs 32.3%; AHR, 0.71; 95% CI, 0.53-0.96; P = .02). Patients undergoing EVAR who were <75 years old and those without preoperative hypotension had the greatest survival benefit from LA compared with GA (both factors: AHR, 0.14 [95% CI, 0.03-0.57]; single factor: AHR, 0.57 [95% CI, 0.36-0.91]). CONCLUSIONS: This study demonstrates that rEVAR-LA for rAAA may be a safe alternative to rEVAR-GA for certain patients, with lower morbidity and improved mortality. Further prospective study is warranted to confirm mortality benefit in rEVAR-LA for rAAA.


Asunto(s)
Anestesia General , Anestesia Local , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anestesia General/efectos adversos , Anestesia General/mortalidad , Anestesia Local/efectos adversos , Anestesia Local/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Ann Vasc Surg ; 38: 339-344, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27666800

RESUMEN

BACKGROUND: The aim of this study was to report the results of percutaneous endovascular aortic aneurysm repair (PEVAR) using the superficial femoral artery (SFA) for large bore vessel access. METHODS: We reviewed all PEVAR procedures at our institution over an 18-month period, identifying all patients who underwent PEVAR with the use of one or both SFAs for endograft delivery with dual ProGlide large bore access closure. Indications for use of the SFA instead of the common femoral artery (CFA) included morbid obesity, CFA vessel wall disease, and scarring from previous CFA surgery. RESULTS: In total, 158 percutaneous access closures were performed in 79 patients. Ten patients had one or both SFAs used. We accessed a total of 13 SFAs: 6 for the endograft main body (size range 18- to 20-French) and 7 for the limb (14- to 16-French). The freedom from open conversion was 84.6%. In comparison, of 145 CFA accesses (in 76 patients) there were 9 conversions (93.7% success). Of the 13 SFAs accessed, there were no major access site complications (pseudoaneurysm, access site bleed, limb ischemia, or need to return to the operating room). All SFAs accessed remained patent at the latest follow-up (range 1-13 months, median 8 months). CONCLUSIONS: Our preliminary case series suggests that, in the absence of a healthy or percutaneously accessible CFA, a healthy SFA may be considered for PEVAR access. While likely carrying a higher risk of open conversion, this technique, when combined with intraoperative duplex ultrasound (both before and after the procedure) and with meticulous ultrasound-guided vascular access, appears safe for up to 20-French device diameters.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Arteria Femoral , Aneurisma de la Aorta/diagnóstico por imagen , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Conversión a Cirugía Abierta , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Arteria Femoral/diagnóstico por imagen , Humanos , Minnesota , Diseño de Prótesis , Punciones , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento , Dispositivos de Acceso Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA