Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39033329

RESUMEN

BACKGROUND: Patients with d-transposition of the great arteries (d-TGA) who have undergone an arterial switch operation (ASO) can develop right ventricular outflow tract (RVOT) dysfunction with pulmonary regurgitation (PR) or stenosis. In these patients, treatment may include transcatheter pulmonary valve replacement (TPVR). Coronary compression is a contraindication occurring in 5% of typical TPVR cases. After ASO, there are various anatomical considerations that can confound TPVR, including potential coronary artery compression. Our goal is to understand feasibility of TPVR in patients following ASO. METHODS: This was a retrospective multicenter cohort study of patients with RVOT dysfunction after ASO who underwent cardiac catheterization with intention to perform TPVR from 2008 to 2020. RESULTS: Across nine centers, 33 patients met inclusion criteria. TPVR was successful in 22 patients (66%), 19 receiving a Melody valve and 3 a SAPIEN valve. RVOT stenosis in isolation or with PR dictated need for TPVR in nearly all patients. One serious adverse event occurred with valve embolization. After TPVR, the RVOT peak gradient decreased from 43 to 9 mm Hg (p < 0.001); PR was trivial/none in all but one patient, in whom it was mild. Coronary compression prohibiting TPVR occurred in eight patients (24%) and two patients (6%) had severe aortic regurgitation from aortic root deformation precluding TPVR. Seven patients underwent RVOT reintervention with a median of 5.3 years post-TPVR. CONCLUSIONS: TPVR in patients with d-TGA after ASO is feasible, but in this cohort, coronary compression or aortic root distortion precluded TPVR in one-third of patients. The rate of RVOT reintervention after TPVR was higher in this cohort of ASO patients that in prior studies.

2.
Pediatr Cardiol ; 45(3): 471-482, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38265483

RESUMEN

Patent ductus arteriosus stenting (PDAS) for ductal-dependent pulmonary blood flow (DDPBF) provides a new paradigm for managing neonates with single ventricles (SV). Currently, sparse data exist regarding outcomes for subsequent palliation. We describe our experience with inter-stage care and stage 2 (S2P) conversion with PDAS in comparison to a prior era of patients who received surgical aorto-pulmonary shunts (APS). Retrospective review of 18 consecutive DDPBF SV patients treated with PDAS between 2016 and 2021 was done and compared with 9 who underwent APS from 2010 to 2016. Patient outcomes and pulmonary artery (PA) growth were analyzed. S2P was completed in all 18 with PDAS with no cardiac arrests and one post-S2P mortality. In the 9 APS patients, there was one cardiac arrest requiring ECMO and one mortality inter-stage. Off cardiopulmonary bypass strategy was utilized in 10/18 in the PDAS and 1/9 in the APS group (p = 0.005) at S2P. Shorter ventilation time, earlier PO feeding, and shorter hospital stay were noted in the PDAS group (p = 0.01, p = 0.006, p = 0.03) (S2P). Median Nakata index increase inter-stage was not significant between the PDAS and APS at 94.1 mm2/m2 versus 71.7 mm2/m2 (p = 0.94). Median change in pulmonary artery symmetry (PAS) was - 0.02 and - 0.24, respectively, which was statistically significant (p = 0.008). Neurodevelopmental outcomes were better in the PDAS group compared to the APS group (p = 0.02). PDAS provides excellent PA growth, inter-stage survival, progression along multistage single-ventricle palliation, and potentially improved neurodevelopmental outcomes. Most patients can be transitioned through 2 stages of palliation without CPB.


Asunto(s)
Conducto Arterioso Permeable , Corazón Univentricular , Recién Nacido , Humanos , Lactante , Circulación Pulmonar , Resultado del Tratamiento , Cuidados Paliativos , Arteria Pulmonar , Stents , Estudios Retrospectivos , Cateterismo Cardíaco/efectos adversos
3.
Pediatr Cardiol ; 44(2): 381-387, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36383234

RESUMEN

The most significant sequelae of Kawasaki disease (KD) are coronary artery aneurysms, which can lead to risk of future myocardial ischemia. Exercise stress echocardiography allows for non-invasive assessment of myocardial dysfunction. We reviewed our single center experience with exercise stress echocardiography in patients with previous history of KD with coronary aneurysms. We reviewed the records of 53 KD patients who underwent exercise stress echocardiography from 2000 to 2020. Abnormal stress echocardiograms were defined as those showing no increase in biventricular systolic function post-exercise or regional wall motion abnormalities. Computed tomography angiography and cardiac magnetic resonance imaging were reviewed for patients with abnormal stress echocardiograms. Clinical data were reviewed and correlated with stress echocardiogram results. Of the 53 patients, three (5.7%) had an abnormal exercise stress echocardiogram. All three patients were classified as AHA Risk Level 4 or 5 by coronary Z-score (internal dimension normalized for body surface area) and were confirmed to have coronary aneurysms, stenosis, or myocardial tissue perfusion defects on advanced cardiac imaging that could account for the results seen on stress echocardiogram. Exercise stress echocardiography detected signs of myocardial ischemia in a subset of high-risk patients with Kawasaki disease and coronary aneurysms and may be considered as a useful screening tool for this complex patient cohort.


Asunto(s)
Aneurisma Coronario , Enfermedad de la Arteria Coronaria , Síndrome Mucocutáneo Linfonodular , Isquemia Miocárdica , Humanos , Aneurisma Coronario/diagnóstico por imagen , Aneurisma Coronario/etiología , Ecocardiografía de Estrés , Síndrome Mucocutáneo Linfonodular/complicaciones , Enfermedad de la Arteria Coronaria/complicaciones , Isquemia Miocárdica/complicaciones , Prueba de Esfuerzo , Angiografía Coronaria
4.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36995404

RESUMEN

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Lactante , Humanos , Conducto Arterioso Permeable/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Sistema de Registros , Factores de Tiempo , Estudios Retrospectivos
5.
J Interv Cardiol ; 2022: 7602793, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36447937

RESUMEN

Background: Fontan-associated liver disease is a well-known sequela following the Fontan procedure for patients living with single-ventricle heart disease. Pulmonary vasodilators, such as phosphodiesterase type 5 inhibitors, have emerged as a potential therapeutic option for lowering central venous pressures by reducing pulmonary vascular resistance. Method: We performed a single-center retrospective review of Fontan patients who were placed on pulmonary vasodilator therapy with prehemodynamic and posthemodynamic, MR elastography, and histologic assessments. Results: A total of 125 patients with Fontan circulation underwent surveillance with cardiac catheterization during the review period. Fifty-three (42%) patients who did not have increased end-diastolic pressures at the time of cardiac catheterization were started on phosphodiesterase type 5 inhibitor therapy. Nine patients (17%) underwent posttherapy follow-up catheterization. The mean Fontan pressure decreased from 15.4 ± 3.3 mmHg to 13.3 ± 2.5 mmHg (p=0.026), after initiation of pulmonary vasodilatory therapy. There was no change in end-diastolic pressure, transpulmonary gradient, wedge pressure, pulmonary vascular resistance, cardiac index, or saturation. Eleven patients (21%) underwent pretherapy MR elastography testing with posttherapy follow-up MR elastography. We found no improvement in liver stiffness score following the application of pulmonary vasodilators. Three patients underwent pretherapy and posttherapy liver biopsies, with variable histological changes observed within the hepatic parenchyma. Conclusions: These data demonstrate indeterminate results for the selective use of pulmonary vasodilators but highlight the need for large prospective randomized control trials of pulmonary vasodilator therapies to fully assess the benefit of such therapies in Fontan-associated liver disease.


Asunto(s)
Cateterismo Cardíaco , Vasodilatadores , Humanos , Vasodilatadores/uso terapéutico , Estudios Prospectivos , Biopsia , Hígado
6.
J Cardiothorac Vasc Anesth ; 36(3): 707-712, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34175203

RESUMEN

OBJECTIVE: To determine if patients with congenital heart disease are undergoing laparoscopic surgery requiring abdominal insufflation and to compare the outcomes of these procedures with those who underwent an open surgical approach. DESIGN, SETTING, PARTICIPANTS: This was a retrospective study using the National Inpatient Sample from 2006 to 2014. Individuals with congenital heart disease who underwent at least one of six selected surgical procedures (laparoscopic or open) were included in the study. Subgroup analysis was performed on patients with Fontan palliation. MEASUREMENTS AND MAIN RESULTS: The primary outcome was to determine the frequency with which congenital heart disease patients undergo laparoscopic surgery requiring abdominal insufflation compared with open surgery. Secondary outcomes included all-cause in-hospital mortality and in-hospital length of stay. Of the 5,527 patients included, nearly half underwent laparoscopic surgery (46.3%), and 128 (2.3%) had single-ventricle circulation. All-cause mortality was significantly higher for those who underwent open surgery compared with the laparoscopic approach (3.6% v 0.9%; odds ratio [OR], 4.0 [2.6-6.3]; p < 0.0001). Subgroup analysis of patients with Fontal palliation older than five years showed 30 (42%) underwent laparoscopic surgery and there was no mortality difference between the laparoscopic and open approaches (OR, 1.4 [0.2-21.3], p = 0.8). Length of stay was significantly shorter for patients undergoing laparoscopic compared with open surgery (median three days [interquartile range, two-five] v six days [three-13], p < 0.0001). CONCLUSIONS: Individuals with congenital heart disease are being offered laparoscopic surgery that requires abdominal insufflation. All-cause mortality and length of stay were higher for patients who underwent open surgical operations.


Asunto(s)
Cardiopatías Congénitas , Insuflación , Laparoscopía , Cardiopatías Congénitas/cirugía , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
7.
Pediatr Cardiol ; 43(8): 1716-1722, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35430709

RESUMEN

We report our experience with transcatheter patent ductus arteriosus (PDA) closure in premature infants and compare patients grouped by the device used for closure: the Microvascular Plug, "MVP" (Medtronic, Minneapolis, MN); Micro Plug Set, "Micro Plug" (KA Medical, Minneapolis, MN); and Amplatzer Piccolo Occluder, "Piccolo" (Abbot, Santa Clara, CA). We also report trends in device selection over time. Studies examining outcomes according to device selection for PDA closure in premature infants are lacking. We performed a retrospective review of all percutaneous PDA closures in premature infants at a single center (June 2018-May 2021). Patients were grouped by initial device selected for PDA closure (intention to treat). Institutional Review Board approval was obtained. 58 premature infants [MVP (n = 25), Micro Plug (n = 25), and Piccolo (n = 8)] underwent successful transcatheter PDA closure (mean gestational age 27 weeks 2 days; mean weight at procedure 1.4 kg; mean age at procedure 28 days). Pre-procedural demographics, procedural data, and follow-up data were similar between groups. There were no significant procedural adverse events. Three devices (2 MVP, 0 Micro Plug, 1 Piccolo p = 0.27) embolized after the procedure. One other device was removed for concern for aortic obstruction. Device selection evolved with a clear trend toward the Micro Plug device over time. Demographic, procedural, and follow-up data were similar between the MVP, Micro Plug, and Piccolo groups. The Micro Plug did not require exchange for suboptimal fitting or embolize and became our preferred device in most cases.


Asunto(s)
Conducto Arterioso Permeable , Enfermedades del Prematuro , Dispositivo Oclusor Septal , Recién Nacido , Lactante , Humanos , Conducto Arterioso Permeable/cirugía , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Recien Nacido Prematuro , Estudios Retrospectivos
8.
Pediatr Cardiol ; 43(4): 894-902, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34894280

RESUMEN

Guidelines for management of Melody transcatheter pulmonary valve (TPV) infective endocarditis (IE) are lacking. We aimed to identify factors associated with surgical valve removal versus antimicrobial therapy in Melody TPV IE. Multicenter retrospective analysis of all patients receiving Melody TPV from 10/2010 to 3/2019 was performed to identify cases of IE. Surgical explants versus non-surgical cases were compared. Of the 663 Melody TPV implants, there were 66 cases of IE in 59 patients (59/663, 8.8%). 39/66 (59%) were treated with IV antimicrobials and 27/66(41%) underwent valve explantation. 26/59 patients (44%) were treated medically without explantation or recurrence with average follow-up time of 3.5 years (range:1-9). 32% of Streptococcus cases, 53% of MSSA, and all MRSA cases were explanted. 2 of the 4 deaths had MSSA. CART analysis demonstrated two important parameters associated with explantation: a peak echo gradient ≥ 47 mmHg at IE diagnosis(OR 10.6, p < 0.001) and a peak echo gradient increase of > 24 mmHg compared to baseline (OR 6.7, p = 0.01). Rates of explantation varied by institution (27 to 64%). In our multicenter experience, 44% of patients with Melody IE were successfully medically treated without valve explantation or recurrence. The degree of valve stenosis at time of IE diagnosis was strongly associated with explantation. Rates of explantation varied significantly among the institutions.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Cateterismo Cardíaco/efectos adversos , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/tratamiento farmacológico , Endocarditis Bacteriana/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
9.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34743224

RESUMEN

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Asunto(s)
Defectos del Tabique Interatrial , Exposición a la Radiación , Dispositivo Oclusor Septal , Cateterismo Cardíaco/métodos , Fluoroscopía/métodos , Defectos del Tabique Interatrial/cirugía , Humanos , Mejoramiento de la Calidad , Dosis de Radiación , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Physiol ; 599(1): 343-356, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33026102

RESUMEN

KEY POINTS: The distribution of pulmonary perfusion is affected by gravity, vascular branching structure and active regulatory mechanisms, which may be disrupted by cardiopulmonary disease, but this is not well studied, particularly in rare conditions. We evaluated pulmonary perfusion in patients who had undergone Fontan procedure, patients with pulmonary arterial hypertension (PAH) and two groups of controls using a proton magnetic resonance imaging technique, arterial spin labelling to measure perfusion. Heterogeneity was assessed by the relative dispersion (SD/mean) and gravitational gradients. Gravitational gradients were similar between all groups, but heterogeneity was significantly increased in both patient groups compared to controls and persisted after removing contributions from large blood vessels and gravitational gradients. Patients with Fontan physiology and patients with PAH have increased pulmonary perfusion heterogeneity that is not explainable by differences in mean perfusion, gravitational gradients, or large vessel anatomy. This probably reflects vascular remodelling in PAH and possibly in Fontan physiology. ABSTRACT: Many factors affect the distribution of pulmonary perfusion, which may be disrupted by cardiopulmonary disease, but this is not well studied, particularly in rare conditions. An example is following the Fontan procedure, where pulmonary perfusion is passive, and heterogeneity may be increased because of the underlying pathophysiology leading to Fontan palliation, remodelling, or increased gravitational gradients from low flow. Another is pulmonary arterial hypertension (PAH), where gravitational gradients may be reduced secondary to high pressures, but remodelling may increase perfusion heterogeneity. We evaluated regional pulmonary perfusion in Fontan patients (n = 5), healthy young controls (Fontan control, n = 5), patients with PAH (n = 6) and healthy older controls (PAH control) using proton magnetic resonance imaging. Regional perfusion was measured using arterial spin labelling. Heterogeneity was assessed by the relative dispersion (SD/mean) and gravitational gradients. Mean perfusion was similar (Fontan = 2.50 ± 1.02 ml min-1  ml-1 ; Fontan control = 3.09 ± 0.58, PAH = 3.63 ± 1.95; PAH control = 3.98 ± 0.91, P = 0.26), and the slopes of gravitational gradients were not different (Fontan = -0.23 ± 0.09 ml min-1  ml-1  cm-1 ; Fontan control = -0.29 ± 0.23, PAH = -0.27 ± 0.09, PAH control = -0.25 ± 0.18, P = 0.91) between groups. Perfusion relative dispersion was greater in both Fontan and PAH than controls (Fontan = 1.46 ± 0.18; Fontan control = 0.99 ± 0.21, P = 0.005; PAH = 1.22 ± 0.27, PAH control = 0.91 ± 0.12, P = 0.02) but similar between patient groups (P = 0.13). These findings persisted after removing contributions from large blood vessels and gravitational gradients (all P < 0.05). We conclude that patients with Fontan physiology and PAH have increased pulmonary perfusion heterogeneity that is not explained by differences in mean perfusion, gravitational gradients, or large vessel anatomy. This probably reflects the effects of remodelling in PAH and possibly in Fontan physiology.


Asunto(s)
Procedimiento de Fontan , Hipertensión Arterial Pulmonar , Humanos , Pulmón , Perfusión , Circulación Pulmonar
11.
Cardiol Young ; 31(10): 1613-1618, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33641693

RESUMEN

INTRODUCTION: Many newborns with pulmonary atresia/intact ventricular septum require intervention to establish pulmonary flow and sufficient cardiac output. The resulting haemodynamic changes are not well characterised and may have unintended consequences. METHODS: This is a 30-year (1988-2018) retrospective study of patients with pulmonary atresia intact ventricular septum. RESULTS: Eighty-nine patients were included, and median follow-up was 8 years. Fifty-five per cent had coronary sinusoids and 27% had right ventricular-dependent coronary circulation. Most patients were managed with surgical aortopulmonary or modified Blalock-Taussig shunt (73%), and 12 patients underwent balloon atrial septostomy before surgical intervention. The remaining patients (27%) underwent only transcatheter interventions; 7 required an atrial septostomy and 17 required ductal stentings. All-cause mortality was 10%, most deaths (89%) occurred before 18 months of age. Of these early deaths, 87% required a balloon atrial septostomy and 85% had right ventricular-dependent coronary sinusoids. Eighteen-month mortality was significantly higher for patients who required a balloon atrial septostomy compared to those who did not (36% versus 1.4% p < 0.0001). DISCUSSION: Patients with pulmonary atresia/intact ventricular septum who require balloon atrial septostomy in the newborn period have significantly higher 18-month mortality. Quantifying the mortality difference may help guide prognostication and expectation setting. Infants who had septostomy and a surgical shunt in the newborn period fared better than those who only underwent septostomy (even when accompanied by ductal stenting). For infants with right ventricular-dependent circulation, atrial septostomy should only be performed on an urgent or emergent basis and these patients should be considered for early surgical intervention and neonatal transplant.


Asunto(s)
Cardiopatías Congénitas , Atresia Pulmonar , Tabique Interventricular , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Recién Nacido , Atresia Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/cirugía
12.
Catheter Cardiovasc Interv ; 96(7): 1439-1444, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32979038

RESUMEN

OBJECTIVES: We intend to describe early experience using a new, commercially available Micro Plug Set for preterm neonate and infant transcatheter patent ductus arteriosus (PDA) occlusion. BACKGROUND: Transcatheter PDA occlusion in premature neonates and small infants is safe and effective. The procedure is early in its evolution. METHODS: Procedural and short-term outcomes of preterm neonates and infants undergoing transcatheter PDA occlusion with a new, commercially available device were reviewed. RESULTS: Eight preterm neonates and infants born at median 27 weeks gestation (23-36 weeks) underwent transcatheter PDA device closure with the Micro Plug Set. The device is short (2.5 mm) with a range of diameters (3, 4, 5, 6 mm) and delivered through a microcatheter. Procedures were performed at median 41 days of age (12-88 days) and at 1690 g (760-3,310 g). Transvenous PDA device occlusion was performed with fluoroscopic and echocardiography guidance. All procedures were successful with complete PDA occlusion. There were no procedural or short-term adverse events. CONCLUSIONS: Preterm neonate and infant transcatheter PDA device closure with a new, commercially available short and microcatheter delivered device (Micro Plug Set) was safe and effective in a small, early series of patients.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/terapia , Peso al Nacer , Cateterismo Cardíaco/efectos adversos , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Diseño de Equipo , Edad Gestacional , Humanos , Recién Nacido de Bajo Peso , Recién Nacido , Recien Nacido Prematuro , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 96(7): 1434-1438, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32926536

RESUMEN

BACKGROUND: Patent ductus arteriosus (PDA) stenting is evolving as an alternative to surgical aorto-pulmonary shunts for infants with ductal-dependent pulmonary blood flow. Given anatomical proximity, the PDA can compress the ipsilateral bronchus. We report a case series of four patients with bronchial compression by a tortuous PDA who underwent PDA stenting. METHODS: Our four patients received PDA stents for ductal-dependent pulmonary blood flow despite preprocedure imaging evidence of bronchial compression. We reviewed the cross-sectional chest imaging to assess the degree of bronchial compression and the variables that affect it, namely PDA size, PDA tortuosity, and the anatomical relationship between the compressed bronchus and the PDA. RESULTS: Three out of the four patients had postprocedure imaging, and all showed relief of the previously seen bronchial compression. Post-PDA stenting patients had a smaller and straight PDA with significant lateralization away from the compressed bronchus. None of the four patients developed symptoms of bronchial compression poststenting. CONCLUSIONS: Our study suggests that pre-existing bronchial compression does not preclude PDA stenting. Stent placement in an engorged and tortuous PDA led to significant improvement in pre-existing bronchial compression. Improvement may be attributed to PDA shrinkage, straightening, and lateralization. Further studies are needed to confirm our findings.


Asunto(s)
Enfermedades Bronquiales/terapia , Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/terapia , Circulación Pulmonar , Stents , Enfermedades Bronquiales/diagnóstico por imagen , Enfermedades Bronquiales/etiología , Enfermedades Bronquiales/fisiopatología , Cateterismo Cardíaco/efectos adversos , Constricción Patológica , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Humanos , Lactante , Recién Nacido , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
14.
Pediatr Cardiol ; 40(2): 445-453, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30506273

RESUMEN

To stratify diverse procedure types into categories with similar radiation exposure in cardiac catheterization for congenital heart disease. Radiation exposures for a comprehensive list of specific procedure types and stratification of outcomes based on radiation risk are not currently available. Data between January 2014 and December 2015 were collected on all cases performed at sites participating in C3PO-QI (Congenital Cardiac Catheterization Outcomes Project-Quality Improvement Initiative) and 9 centers were included. Using expert consensus, 40 unique procedure types were defined by diagnostic characteristics or the intervention(s) performed, and dose area product (DAP) per kilogram of body weight (µGy × m2/kg) was summarized. Using empiric and consensus methods, three radiation risk categories were created. A total of 11,735 cases were included for analysis. Thirteen (n = 7918) procedure types with median DAP/kg < 100 were categorized in the low radiation exposure category (median DAP/kg 39). The medium exposure category (n = 1807) consisted of 16 procedure types with median DAP/kg values ranging 100 to < 200 (overall median DAP/kg 131). Finally, the high radiation exposure category (n = 1073) consisted of 11 procedure types with median DAP/kg ≥ 200 (overall median DAP/kg of 231). The radiation exposure risk categories created in this multi-center dataset are a critical step towards the development of a robust risk adjustment methodology for radiation exposure in catheterization for congenital heart disease.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Fluoroscopía/efectos adversos , Cardiopatías Congénitas/cirugía , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Adolescente , Niño , Preescolar , Consenso , Humanos , Lactante , Estudios Prospectivos , Mejoramiento de la Calidad , Dosis de Radiación , Medición de Riesgo/métodos , Factores de Riesgo , Adulto Joven
15.
J Card Surg ; 33(10): 653-657, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30199920

RESUMEN

BACKGROUND: Dacron tube grafts have been used in the surgical management of cardiovascular disease since the 1970s. Complications at the site of the anastomosis have been well described. Non-anastomotic failure is far less common. We present a series of four patients who presented with complications of non-anastomotic failure of woven Dacron tube grafts. METHODS: A retrospective chart review of four patients who presented to our institution between March 2014 and March 2017 with clinical complications of a Dacron tube graft was conducted. RESULTS: All four patients underwent a staged surgical repair for an interrupted aortic arch between the years of 1988 and 2001. All four patients underwent revision of their original interposition graft (Gore-Tex, W.L. Gore & Associates, Flagstaff, AZ) with implantation of a Hemashield woven Dacron tube graft (Maquet, Rastatt, Germany). From 13 to 22 years postimplant of the Dacron tube graft, all patients presented with symptoms or clinical evidence of primary graft failure. Two patients underwent urgent surgical intervention and did not survive. One patient underwent attempted surgical intervention, which was aborted in the setting of profuse bleeding, and ultimately had an endovascular rescue of the tube graft with a Zenith Alpha endograft (Cook Medical, Bloomington, IN). One patient underwent elective endovascular intervention prior to onset of symptoms. CONCLUSION: Non-anastomotic failure of woven Dacron tube grafts can occur in the thoracic aorta in young adults and may be managed with endovascular techniques.


Asunto(s)
Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/métodos , Tereftalatos Polietilenos/efectos adversos , Falla de Prótesis , Adolescente , Adulto , Resultado Fatal , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
16.
Catheter Cardiovasc Interv ; 90(6): 982-985, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28568976

RESUMEN

The phenomenon of coronary steal is well known in the setting of HLHS (Hypoplastic Left Heart Syndrome) early after the Classical Norwood Operation. We report a rare case of an infant with HLHS [Severe Aortic Stenosis (AS), Mitral Stenosis (MS) and small Left Ventricle (LV)], who developed aortic regurgitation and presumed coronary steal late after the Sano Modification of the Norwood Procedure. Coronary steal developed secondary to progressive aortic and mitral regurgitation and resulted in poor right ventricular function and severe tricuspid regurgitation. We describe a novel interventional approach for obliteration of the LV cavity by using hydrogel coils. LV obliteration eliminated the presumed steal and resulted in improvement in ventricular function, tricuspid regurgitation and clinical course.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Ventrículos Cardíacos/cirugía , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Procedimientos de Norwood/efectos adversos , Complicaciones Posoperatorias , Dispositivo Oclusor Septal , Angiografía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Síndrome del Corazón Izquierdo Hipoplásico/diagnóstico , Lactante , Masculino , Reoperación
17.
Catheter Cardiovasc Interv ; 90(4): 626-630, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-28471087

RESUMEN

Despite few institutions stenting the ascending aorta, it has been discouraged because of the proximity of the aortic valve, the coronary artery orifices, and the aortic arch branches. We describe a small case series of patients having acquired stenosis of the ascending that was relieved successfully by stenting. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia de Balón/instrumentación , Aorta , Enfermedades de la Aorta/terapia , Arteriopatías Oclusivas/terapia , Stents , Adulto , Aorta/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Aortografía/métodos , Arteriopatías Oclusivas/diagnóstico por imagen , Niño , Angiografía por Tomografía Computarizada , Constricción Patológica , Humanos , Masculino , Resultado del Tratamiento , Adulto Joven
18.
Catheter Cardiovasc Interv ; 88(7): 1108-1112, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27527119

RESUMEN

OBJECTIVES: To examine the factors contributing to arterial thrombosis after catheterization, particularly the use of long vs. short introducer sheaths, and propose a new protocol to address risks. BACKGROUND: Post-procedure arterial compromise is an important concern in pediatric cardiac catheterizations. For certain interventional procedures, the use of a long sheath is necessary, however, the incidence of complications when using such sheaths has not yet been studied. METHODS: This retrospective review includes patients <15 kg who underwent femoral artery catheterization at our institution from Feb 2006 to June 2014. The study examined 29 long sheath and 40 matched interventional short sheath cases. Data collected included age, weight, time to arterial access, total sheath duration, and arterial complications. The long sheath and short sheath groups, and confounding factors, were compared for complication rate. RESULTS: The incidence of arterial compromise was 38% (11/29) in the long sheath group compared to 15% (6/40) for short sheaths (P = 0.029). Arterial thrombosis was documented by ultrasound, CT, or angiography in 71% (12/17) patients. Time to arterial access and total sheath duration were not statistically significant factors. Weight was an independent risk factor, with infants <5 kg having a higher complication rate compared to infants >5 kg at 38.2% (13/34) and 11.4% (4/35), respectively (P = 0.004). Sheath length remained statistically significant after taking weight and age into account (P = 0.011). CONCLUSION: The use of a long sheath in infants <15 kg is a significant risk factor for arterial compromise compared to short sheaths. Lower patient weight is also a contributing factor to increased incidence of complication, particularly in those <5 kg. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Arteriopatías Oclusivas/epidemiología , Cateterismo Periférico/efectos adversos , Arteria Femoral , Trombosis/epidemiología , Factores de Edad , Anticoagulantes/administración & dosificación , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/tratamiento farmacológico , Peso Corporal , California/epidemiología , Cateterismo Periférico/instrumentación , Cateterismo Periférico/métodos , Preescolar , Protocolos Clínicos , Angiografía por Tomografía Computarizada , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Fibrinolíticos/administración & dosificación , Heparina/administración & dosificación , Humanos , Incidencia , Lactante , Recién Nacido , Masculino , Punciones , Estudios Retrospectivos , Factores de Riesgo , Terapia Trombolítica , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Factores de Tiempo , Activador de Tejido Plasminógeno/administración & dosificación , Ultrasonografía Doppler , Dispositivos de Acceso Vascular
19.
Pediatr Cardiol ; 37(8): 1436-1445, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27502109

RESUMEN

The Congenital Cardiac Catheterization Project on Outcomes (C3PO) launched in 2007 as a multi-center collaborative to establish standardized and comparable metrics for pediatric cardiac catheterization procedures. The limitations of larger registries at the time led to the development of the next phase in 2013, C3PO-Quality Improvement (C3PO-QI), focusing on instituting QI initiatives within the field. The objective of this manuscript is to provide a detailed overview of C3PO-QI and report data on case characteristics and outcome metrics being explored. C3PO-QI was designed to cultivate institutional collaboration during implementation of its initiatives. A database and website were developed to support data entry and on-demand reporting. The registry prospectively captures pediatric cardiac catheterization data among 15 hospitals. The present study includes case demographic data (n) and quality metric reporting by case type, age, and radiation dose variables. This dataset includes 13,135 cases entered into the database between 1/1/2014 and 12/31/2015. Interventional cases make up the highest percentage by case mix distribution (48 %), and patients <1 years make up the highest percentage by age distribution (26 %). The ratio of diagnostic and interventional procedures performed changes by age group. Application of QI metric shows all procedure types surpassing metric goals. Large volume data collection, such as in C3PO-QI, allows for meaningful interpretation of data. C3PO-QI is uniquely poised to deliver fast-paced changes in the field. Although the project initiatives are specific to pediatric cardiac catheterization, the implementation of the project and utilization of real-time reporting is generalizable to other specialties and multi-center collaboratives.


Asunto(s)
Cateterismo Cardíaco , Niño , Bases de Datos Factuales , Cardiopatías Congénitas , Humanos , Mejoramiento de la Calidad , Sistema de Registros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA