Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Prosthet Dent ; 131(5): 933.e1-933.e7, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38429151

RESUMEN

STATEMENT OF PROBLEM: The connector height and retainer occlusal thickness of fixed partial dentures (FPDs) may affect restoration longevity. PURPOSE: The purpose of this in vitro study was to determine and compare the fracture resistance of 4-unit monolithic 5% yttria tetragonal zirconia polycrystal (5Y-TZP) FPDs made with different connector heights and retainer occlusal thicknesses after thermomechanical aging. MATERIAL AND METHODS: Forty test metal dies were duplicated from a master metal die containing 2 anatomic abutment preparations of the mandibular right first premolar and second molar for a 4-unit FPD. The dies were divided into 2 groups of 20 each for the fabrication of 4-unit FPDs, with 2-mm and 4-mm uniform connector heights at all 3 connectors, resulting in 6.3-mm2 and 12.6-mm2 connector areas. Each of these groups was further divided into 2 subgroups based on the occlusal thickness of the 2 retainers of 1 mm and 2 mm (n=10). Polyvinyl siloxane impressions of the test metal dies were made and poured in Type V dental stone. Laboratory scans were performed on all the stone dies, and 40 5Y-TZP FPDs (Ceramill Zolid FX) were designed and fabricated. Subsequently, all the FPDs were luted on to the metal dies with a self-adhesive resin cement. The FPDs were preloaded (400 000 mechanical cycles; 4000 thermocycles) using a mastication simulator and tested for axial compressive strength. Two-way analysis of variance (ANOVA) was used to examine the effect of connector and occlusal thicknesses on the fracture load (α=.05). The data were further assessed using the post hoc Tukey HSD multiple comparison test (α=.05). RESULTS: The mean fracture load values were between 737 N and 1563 N. Significant differences in the mean fracture load were found between the connector heights (601 N; P<.001) and occlusal thicknesses (225 N; P=.002), but the interaction of the 2 factors was not significant (P=.132) The Tukey post hoc analysis showed significant differences between the connector thicknesses groups (P<.01), but the occlusal thicknesses were found to be similar for the same connector height (P=.609) CONCLUSIONS: Connector height and occlusal retainer thickness influenced the fracture load of 4-unit monolithic 5Y-TZP FPDs after thermomechanical aging.


Asunto(s)
Análisis del Estrés Dental , Diseño de Dentadura , Dentadura Parcial Fija , Itrio , Circonio , Circonio/química , Itrio/química , Fracaso de la Restauración Dental , Humanos , Ensayo de Materiales , Técnicas In Vitro , Materiales Dentales/química , Pilares Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA