Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Int J Health Sci (Qassim) ; 18(3): 23-29, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721136

RESUMEN

Objectives: Reinforcement of polymethylmethacrylate (PMMA) denture base resins (DBRs) with inorganic fillers with superior properties and accepted aesthetics are favored and still a big dilemma. This study was undertaken to evaluate the color change, flexural strength, and modulus of elasticity of heat-polymerized DBR material modified with silver nanoparticles (AgNPs) and zirconium dioxide nanoparticles (ZNPs). Methods: Sixty acrylic specimens (30/color test, 30/flexural properties) were fabricated and divided according to nanoparticles type and addition into 3 groups (n = 10). Group-I; unmodified specimens, Group-II; modified specimens with 0.5wt% AgNPs (PMMA/AgNPs), and Group-III; modified specimens with 7.5wt% ZNPs (PMMA/ZNPs). Disc-shape (20 × 3 mm) and bar-shape (65 × 10 × 2.5 mm) specimens were fabricated for color and flexural properties, respectively. The spectrophotometer was used for evaluation of the color change (∆E). The flexural strength and elastic modulus evaluation was carried out using a 3-point bending test (5 mm/min). Tukey's post hoc and one-way ANOVA were used to analyze the data at a significant level P ≤ 0.05. Results: PMMA/AgNPs group exhibited a significant increase in color change when compared with PMMA/ZNPs. PMMA/ZNPs showed significantly the highest flexural strength value when compared with unmodified and PMMA/AgNPs groups (P < 0.001), however, there was an absence of significant differences in terms of flexural strength values between PMMA/AgNPs and unmodified groups (P > 0.05). PMMA/AgNPs insignificantly increased its modulus of elasticity strength (P = 0.09410) while PMMA/ZNPs significantly increased its modulus of elasticity strength (P = 0.00396). Conclusion: The AgNPs and ZNPs addition to PMMA increased the color change and AgNPs change the color of DBRs. The flexural attributes of DBRs have been increased by ZNPs.

2.
J Int Soc Prev Community Dent ; 14(2): 136-143, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38827358

RESUMEN

Aim: Internal disc displacement of the temporomandibular joint (TMJ) is identified by an anomaly between the condylar-disc assembly, which, in many cases, may lead to discomfort and malfunction of the chewing function. The study's objective was to assess the effects of four distinct treatment approaches on temporomandibular disorder cases with anterior disc displacements focusing on their chewing efficiency. Materials and Methods: One hundred participants suffering from reducible TMJ disc displacement were selected for enrollment in the study. Subjects were divided equally into four groups: group I patients were treated with behavioral therapy; group II patients were treated with low-level laser therapy (LLLT); group III patients were treated with anterior repositioning splints; and group IV patients were treated with flat plane splints. Chewing efficiency was assessed utilizing the fractional sieving method and a synthetic food substitute was created using silicon impression material. The statistical analysis encompassed comparisons of chewing efficiency between groups and between baseline and posttreatment within each group, employing analysis of variance (ANOVA) and paired t tests, respectively. Results: Using the paired t test, a significant difference in chewing efficiency values as expressed by the median particle size was observed between the baseline and 6-month values in all groups (P < 0.05), except for group I where no significant change was noted over the 6 months (P > 0.05). The one-way ANOVA test revealed a statistically significant difference among groups following therapies (P ˂ 0.05). The post hoc Tukey test was employed for pairwise comparisons and revealed statistically significant variances in the main values of chewing efficiency among all groups at a 95% confidence level (P ˂ 0.05). Conclusion: The study's results suggest that occlusal splints and LLLT are more effective in improving chewing efficiency than behavioral interventions.

3.
Dent J (Basel) ; 12(2)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38392236

RESUMEN

BACKGROUND: Digital technology has been introduced in prosthodontics, and it has been widely used in denture duplication instead of a conventional denture duplication technique. However, research comparing different denture duplication techniques and how they affect the fitting accuracy of the denture base is scarce. OBJECTIVES: The aim was to assess the impact of duplication techniques on the accuracy of the fitting surface of computer-aided design and manufacturing (CAD-CAM) milled, 3D-printed, and injection-molded complete denture bases (CDBs). METHODOLOGY: This study involved fabricating a mandibular complete denture base with three marked dimples as reference marks (A, B, and C at the incisive papilla, right molar, and left molar areas) using a conventional compression molded technique. This denture was then scanned to generate a standard tessellation language (STL) file; after that, it was duplicated using three different techniques (milling, 3D printing, and injection molding) and five denture base resin materials-two milled CAD-CAM materials (AvaDent and IvoBase), two 3D-printed materials (NextDent and HARZ Labs), and one injection-molded material (iFlextm). Based on the denture base type, the study divided them into five groups (each with n = 10). An evaluation of duplication accuracy was conducted on the fitting surface of each complete denture base (CDB) using two assessment methods. The first method was a two-dimensional evaluation, which entailed linear measurements of the distances (A-B, A-C, and B-C) between reference points on both the scanned reference mandibular denture and the duplicated dentures. Additionally, a three-dimensional superimposition technique was employed, involving the overlay of the STL files of the dentures onto the reference denture's STL file. The collected data underwent statistical analysis using a one-way analysis of variance and Tukey's pairwise post hoc tests. RESULTS: Both evaluation techniques showed significant differences in fitting surface accuracy between the tested CDBs (p ˂ 0.001), as indicated by one-way ANOVA. In addition, the milled CDBs (AvaDent and IvoBase) had significantly higher fitting surface accuracy than the other groups (p ˂ 0.001) and were followed by 3D-printed CDBs (NextDent and HARZ Labs), while the injection-molded (iFlextm) CDBs had the lowest accuracy (p ˂ 0.001). CONCLUSIONS: The duplication technique of complete dentures using a CAD-CAM milling system produced superior fitting surface accuracy compared to the 3D-printing and injection-molded techniques.

4.
J Int Soc Prev Community Dent ; 13(5): 394-401, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38124728

RESUMEN

Aim: To study the masticatory efficacy and oral health-related quality of life (OHRQoL) of participants wearing a mandibular overdenture retained by an immediate loading single implant with different occlusal tooth forms. Materials and Methods: For this nonrandomized controlled trial study, 27 edentulous participants were selected and randomly divided into three groups (n = 9) based on occlusal tooth forms of the mandibular implant overdenture (MIOD). Group I: participants received an MIOD with an anatomical tooth form; Group II: participants received an MIOD with a semianatomical tooth form; and Group III: participants received an MIOD with a nonanatomical tooth form. For each participant, a single implant (screw root form) was inserted into the midline of the mandibular ridge to support the MIOD. For each group, the masticatory efficiency was evaluated after 3 months, and the OHRQoL of the participants was evaluated after 3 and 6 months. One-way ANOVA and post hoc Tukey's test were used for data analysis (P < 0.05). Results: The masticatory efficiency of the anatomic and semianatomic tooth forms was higher than that of the nonanatomic (P < 0.05). Moreover, the improvement in the participants' OHRQoL in the anatomic group was more significant than that of other groups (P < 0.05). Conclusion: There was a greater improvement in masticatory efficiency and participants' OHRQoL when fitted with an anatomic tooth form mandibular overdenture retained by an immediate loading single implant than with a semianatomic or nonanatomic tooth form.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA