Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Platelets ; 27(7): 642-649, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27809712

RESUMEN

Thrombelastography (TEG) measured by the TEG5000 Hemostasis Analyzer is an established but the labor-intensive method for assessing global hemostasis. The first true point-of-care TEG, the TEG6s system, uses resonance-frequency viscoelasticity measurements and a disposable multi-channel microfluidic cartridge to assess hemostasis and response to antiplatelet therapy. TEG assays (n = 5,100) were performed on the blood of healthy volunteers (n = 157) and patients undergoing coronary revascularization at three hospitals (n = 300). The results from the TEG6s were compared with the conventional TEG5000 in accordance with Clinical and Laboratory Standards Institute (CLSI) and FDA recommendations. Precision testing was conducted using blood from healthy donors, all assays were run for 5 consecutive days in duplicate using multiple operators, lots, and instruments. Reference ranges were comparable between the TEG systems. Deming regression analysis demonstrated a strong correlation between the two systems for the standard hemostasis tests (R r = 0.932, MA r = 0.972, LY30 r = 0.938). Method comparison analysis showed an acceptable agreement between PlateletMapping (PM) assays for measuring arachidonic acid (indicator of aspirin response)- and adenosine diphosphate (indicator of P2Y12 inhibitor response)-induced platelet aggregation (total agreement = 90%, and 72%, respectively). TEG6s precision testing yielded low variability (CV 0-13%) in all measures. The new point-of-care TEG6s is associated with greater ease of use than the TEG5000 and provides precise results. The results correlated between methods for all variables. TEG6s is a promising device for near-patient hemostasis monitoring and future trials of personalized therapy designed to reduce bleeding and thrombosis.


Asunto(s)
Sistemas de Atención de Punto , Tromboelastografía/métodos , Procedimientos Quirúrgicos Cardíacos , Femenino , Hemostasis , Humanos , Masculino , Intervención Coronaria Percutánea , Agregación Plaquetaria/efectos de los fármacos , Inhibidores de Agregación Plaquetaria/farmacología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pruebas de Función Plaquetaria/métodos , Pruebas de Función Plaquetaria/normas , Valores de Referencia , Reproducibilidad de los Resultados , Tromboelastografía/normas
2.
J Extra Corpor Technol ; 48(2): 71-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27578897

RESUMEN

Excessive bleeding and allogeneic transfusion during adult post-cardiotomy venoarterial extracorporeal membrane oxygenation (ECMO) are potentially harmful and expensive. Balancing the inhibition of clotting and distinguishing surgical from non-surgical bleeding in post-operative period is difficult. The sensitivity of coagulation tests including Thromboelastography(®) (TEG) to predict chest tube drainage in the early hours of ECMO was examined with the use of receiver-operating characteristics (ROC). The results are useful to incorporate in clinical evidence-based algorithms to guide management decisions. In the eighth hour of ECMO, 26 of the 53 adult patients (49%) studied were identified as non-bleeders (less than 2.0 mL/kg/h). All had experienced various types of cardiac surgical procedures. Fifty-two percent were female and the group was 54 ± 19 (mean ± 1 SD) years old. The coagulation parameter threshold with the maximum sensitivity and specificity to predict non-bleeding at 8 hours on ECMO was the kaolin plus heparinase TEG maximum amplitude (KH-TEG MA) at a significant ROC threshold (t) > 50 mm. The activated partial thromboplastin time (aPTT) t < 49 seconds, KH-TEG alpha-angle t > 51°, and the kaolin activated clotting time (ACT) t < 148 seconds were sensitive predictors of non-bleeders. The whole-blood KH-TEG MA was superior to the plasma-based aPTT or International Normalization Ratio (INR) to predict bleeding in the eighth hour of ECMO. Using coagulation laboratory thresholds that predict non-bleeding can begin a process of identifying patients earlier that are likely to bleed. Awareness of these parameter thresholds may improve care through patient protection from unnecessary transfusion and prolonging the life of the ECMO circuit. An algorithm incorporating the ROC thresholds was created to help recognize surgical bleeding to minimize unnecessary transfusions.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Coagulación Sanguínea , Femenino , Hemorragia , Humanos , Masculino , Persona de Mediana Edad , Tiempo de Tromboplastina Parcial , Tromboelastografía
3.
Anesthesiology ; 122(1): 21-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25611653

RESUMEN

BACKGROUND: Transfusion-associated circulatory overload (TACO) is a leading cause of transfusion-related fatalities, but its incidence and associated patient and transfusion characteristics are poorly understood. To inform surgical transfusion practice and to begin mitigating perioperative TACO, the authors aimed to define its epidemiology. METHODS: In this retrospective cohort study, the medical records of adult patients undergoing noncardiac surgery with general anesthesia during 2004 or 2011 and receiving intraoperative transfusions were screened using an electronic algorithm for identification of TACO. Those patients who were screened as high probability for TACO underwent rigorous manual review. Univariate and multivariate analyses evaluated associations between patient and transfusion characteristics with TACO rates in a before-and-after study design. RESULTS: A total of 2,162 and 1,908 patients met study criteria for 2004 and 2011, respectively. The incidence of TACO was 5.5% (119 of 2,162) in 2004 versus 3.0% (57 of 1,908) in 2011 (P < 0.001), with comparable rates for men (4.8% [98 of 2,023]) and women (3.8% [78 of 2,047]) (P = 0.09). Overall, vascular (12.1% [60 of 497]), transplant (8.8% [17 of 193]), and thoracic surgeries (7.2% [10 of 138]) carried the highest TACO rates. Obstetric and gynecologic patients had the lowest rate (1.4% [4 of 295]). The incidence of TACO increased with volume transfused, advancing age, and total intraoperative fluid balance (all P < 0.001). CONCLUSIONS: The incidence of perioperative TACO is similar to previous estimates in nonsurgical populations. There was a reduction in TACO rate between 2004 and 2011, with incidence patterns remaining comparable in subgroup analyses. Future efforts exploring risk factors for TACO may guide preventive or therapeutic interventions, helping to further mitigate this transfusion complication.


Asunto(s)
Transfusión Sanguínea/estadística & datos numéricos , Volumen Sanguíneo , Atención Perioperativa/estadística & datos numéricos , Reacción a la Transfusión/epidemiología , Anciano , Estudios de Cohortes , Bases de Datos Factuales/estadística & datos numéricos , Femenino , Humanos , Incidencia , Cuidados Intraoperatorios/efectos adversos , Cuidados Intraoperatorios/métodos , Cuidados Intraoperatorios/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Minnesota/epidemiología , Atención Perioperativa/efectos adversos , Atención Perioperativa/métodos , Estudios Retrospectivos , Factores de Riesgo , Distribución por Sexo , Choque , Reacción a la Transfusión/etiología , Resultado del Tratamiento
4.
J Extra Corpor Technol ; 45(3): 167-72, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24303598

RESUMEN

UNLABELLED: The goal of this cardiopulmonary bypass (CPB) quality improvement initiative was to maximize hemoglobin nadir concentration by minimizing hemodilution and, in turn, eliminating allogeneic blood product transfusion. The effects of transitioning from "one-size-fits-all" to "right-sized" oxygenators, reservoirs, and arterial-venous tubing loops were evaluated through a 2-year retrospective review of 3852 patient perfusion records. Using a sizing algorithm, derived from manufacturers' recommendations, we were able to create individualized "right-sized" extracorporeal circuits based on patient body surface area, cardiac index, and target blood flows. Use of this algorithm led to an increase in the percent of algorithm-recommended smaller oxygenators being used from 39% to 63% (p < .01) and an increase in average hemoglobin nadir from 8.38 to 8.76 g/dL (p < .01). Decreased priming volumes led to increased hemoglobin nadir and decreases in allogeneic blood transfusion (p = .048). Patients with similar body surface areas who previously were exposed to larger oxygenators, reservoirs, and arterial-venous loops were now supported with smaller circuits as a result of the use of the right-sized algorithm. Adjustments to the algorithm were made for unique patients and procedural situations including age, gender, and length and type of procedure. Larger heat exchanger surface area oxygenators were used for circulatory arrest procedures as a result of the need for increased heat exchange capability. Despite the generally higher costs of smaller circuits, reduced transfusion-related expenditures and decreased exposure risks justify the use of smaller circuit components. This quality improvement initiative demonstrated that as an integral part of a multidisciplinary, multimodal blood conservation effort, the use of the "right-sized" circuit algorithm can help to elevate hemoglobin nadir during CPB and eliminate allogeneic blood transfusions to patients undergoing CPB. KEYWORDS: cardiopulmonary bypass, oxygenator, perfusion index, extracorporeal circuit, hemodilution.


Asunto(s)
Puente Cardiopulmonar/instrumentación , Puente Cardiopulmonar/métodos , Oxigenación por Membrana Extracorpórea/instrumentación , Oxigenación por Membrana Extracorpórea/métodos , Algoritmos , Transfusión Sanguínea , Puente Cardiopulmonar/efectos adversos , Femenino , Humanos , Masculino , Oxigenadores , Perfusión
5.
Am J Physiol Regul Integr Comp Physiol ; 302(10): R1202-8, 2012 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-22492817

RESUMEN

Hibernating mammals have developed many physiological adaptations to extreme environments. During hibernation, 13-lined ground squirrels (Ictidomys tridecemlineatus) must suppress hemostasis to survive prolonged body temperatures of 4-8°C and 3-5 heartbeats per minute without forming lethal clots. Upon arousal in the spring, these ground squirrels must be able to quickly restore normal clotting activity to avoid bleeding. Here we show that ground squirrel platelets stored in vivo at 4-8°C were released back into the blood within 2 h of arousal in the spring with a body temperature of 37°C but were not rapidly cleared from circulation. These released platelets were capable of forming stable clots and remained in circulation for at least 2 days before newly synthesized platelets were detected. Transfusion of autologous platelets stored at 4°C or 37°C showed the same clearance rates in ground squirrels, whereas rat platelets stored in the cold had a 140-fold increase in clearance rate. Our results demonstrate that ground squirrel platelets appear to be resistant to the platelet cold storage lesions observed in other mammals, allowing prolonged storage in cold stasis and preventing rapid clearance upon spring arousal. Elucidating these adaptations could lead to the development of methods to store human platelets in the cold, extending their shelf life.


Asunto(s)
Plaquetas/fisiología , Conservación de la Sangre/métodos , Frío , Hibernación/fisiología , Modelos Biológicos , Sciuridae/fisiología , Adaptación Fisiológica/fisiología , Animales , Nivel de Alerta/fisiología , Coagulación Sanguínea/fisiología , Temperatura Corporal/fisiología , Hemostasis/fisiología , Ratas
6.
J Cardiothorac Vasc Anesth ; 25(1): 110-9, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20850348

RESUMEN

OBJECTIVE: The aim of this study was to evaluate cardiac risk as a consideration for selecting postoperative sedation and analgesia regimens used for cardiac surgical patients requiring cardiopulmonary bypass and early extubation. DESIGN: An observer-blind, randomized, controlled trial. SETTING: A tertiary referral medical center involving an intensive care unit. PARTICIPANTS: One hundred forty-five adults requiring elective cardiac surgery. INTERVENTIONS: Patients were stratified preoperatively as low, moderate, or high cardiac risk based on established criteria and then assigned to 1 of 3 postoperative regimens: propofol infusion beginning at 25 µg/kg/min and morphine boluses (P), fentanyl infusion beginning at 2 µg/kg/h and midazolam boluses (F), or propofol and fentanyl infusions beginning at 25 µg/kg/min and 0.5 µg/kg/h (PF), respectively. MEASUREMENTS AND MAIN RESULTS: Postoperative regimen P was associated with a significantly reduced time to extubation (median value, 264 minutes; p = 0.05) compared with F (295 minutes) but not PF (278 minutes) in patients characterized as low cardiac risk. The time to extubation did not differ among regimens in patients of moderate/high cardiac risk. CONCLUSION: Patients with low cardiac risk undergoing cardiac surgery had statistically significantly shorter times to extubation with propofol infusion and intermittent morphine than a fentanyl infusion and intermittent midazolam. These differences were not sustained in patients considered at higher cardiac risk. The time to extubation after cardiac surgery may further improve if postoperative sedation and analgesia are not administered uniformly to all patients but selected based on individual characteristics.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hipnóticos y Sedantes/uso terapéutico , Dolor Postoperatorio/tratamiento farmacológico , Cuidados Posoperatorios/métodos , Adolescente , Adulto , Anciano , Analgésicos Opioides/uso terapéutico , Análisis de los Gases de la Sangre , Puente Cardiopulmonar , Cuidados Críticos/economía , Cuidados Críticos/estadística & datos numéricos , Método Doble Ciego , Determinación de Punto Final , Femenino , Fentanilo/uso terapéutico , Hemodinámica/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Morfina/uso terapéutico , Complicaciones Posoperatorias/epidemiología , Náusea y Vómito Posoperatorios/epidemiología , Náusea y Vómito Posoperatorios/prevención & control , Propofol/uso terapéutico , Estudios Prospectivos , Mecánica Respiratoria/efectos de los fármacos , Medición de Riesgo , Desconexión del Ventilador , Adulto Joven
7.
J Extra Corpor Technol ; 43(3): 137-43, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22164452

RESUMEN

Carbon monoxide (CO), a by-product of Heme metabolism, is a potent modulator of inflammation. Low dose inhaled CO has demonstrated reduced lung and kidney injury in animal models of cardiopulmonary bypass (CPB). We evaluated the impact of low dose inhaled CO on systemic, pulmonary, and myocardial inflammatory response to CPB in rats. Sixteen male Sprague-Dawley rats underwent CPB for 1 hour. The CO (n = 8) group received inhaled CO at 250 ppm for 3 hours before CPB. The Air (n = 8) group served as the control. Pulmonary mechanics were assessed pre and post CPB. The animals were recovered for 30 minutes post CPB and subsequently sacrificed. Pre CPB and post CPB serum Tumor Necrosis Factor-alpha (TNF-alpha) and Interleukin-10 (IL-10) were analyzed by enzyme-linked immunosorbent assay. Gene expression array and real time quantitative polymerase chain reaction (PCR) analysis was performed on the extracted heart tissue. Baseline characteristics were similar between the groups with the expected exception of carboxyhemoglobin levels (p < or = .001) and oxyhemoglobin saturation (p < or = .01) in Air versus CO treated groups, respectively. Serum TNF-alpha (363 +/- 278 vs. 287 +/- 195;p = .13) and IL-10 (237 +/- 26 vs. 302 +/- 137; p = Not Significant) in Air versus CO groups respectively were not statistically different after CPB, despite showing a trend of inflammatory attenuation. Gene expression array of the myocardial tissue suggested a pattern of inflammatory modulation, which was confirmed by real time quantitative PCR demonstrating IL-10 expression 3.13 times higher (p = .02) in the CO treated group compared to the Air group. These data demonstrate that pretreatment with CO at 250 ppm may have a modulatory effect on the inflammatory response to CPB without compromising hemodynamics or oxygen delivery. Further investigation in a survival model of CPB is warranted.


Asunto(s)
Monóxido de Carbono/administración & dosificación , Puente Cardiopulmonar , Interleucina-10/metabolismo , Miocardio/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo , Administración por Inhalación , Animales , Monóxido de Carbono/farmacología , Ensayo de Inmunoadsorción Enzimática , Masculino , Ratas , Ratas Sprague-Dawley
8.
Am J Physiol Regul Integr Comp Physiol ; 298(3): R784-9, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20089713

RESUMEN

Cardiopulmonary bypass (CPB) is associated with significant postoperative morbidity, but its effects on the neuromuscular system are unclear. Recent studies indicate that even relatively short periods of mechanical ventilation result in significant neuromuscular effects. Carbon monoxide (CO) has gained recent attention as therapy to reduce the deleterious effects of CPB. We hypothesized that 1) CPB results in impaired neuromuscular transmission and reduced diaphragm force generation; and 2) CO treatment during CPB will mitigate these effects. In adult male Sprague-Dawley rats, diaphragm muscle-specific force and neuromuscular transmission properties were measured 90 min after weaning from normothermic CPB (1 h). During CPB, either low-dose inhaled CO (250 ppm) or air was administered. The short period of mechanical ventilation used in the present study ( approximately 3 h) did not adversely affect diaphragm muscle contractile properties or neuromuscular transmission. CPB elicited a significant decrease in isometric diaphragm muscle-specific force compared with time-matched, mechanically ventilated rats ( approximately 25% decline in both twitch and tetanic force). Diaphragm muscle fatigability to 40-Hz repetitive stimulation did not change significantly. Neuromuscular transmission failure during repetitive activation was 60 +/- 2% in CPB animals compared with 76 +/- 4% in mechanically ventilated rats (P < 0.05). CO treatment during CPB abrogated the neuromuscular effects of CPB, such that diaphragm isometric twitch force and neuromuscular transmission were no longer significantly different from mechanically ventilated rats. Thus, CPB has important detrimental effects on diaphragm muscle contractility and neuromuscular transmission that are largely mitigated by CO treatment. Further studies are needed to ascertain the underlying mechanisms of CPB-induced neuromuscular dysfunction and to establish the potential role of CO therapy.


Asunto(s)
Monóxido de Carbono/farmacología , Puente Cardiopulmonar/efectos adversos , Diafragma , Fatiga Muscular/efectos de los fármacos , Enfermedades de la Unión Neuromuscular , Administración por Inhalación , Animales , Antimetabolitos/farmacología , Temperatura Corporal , Dióxido de Carbono/sangre , Diafragma/efectos de los fármacos , Diafragma/inervación , Diafragma/fisiopatología , Relación Dosis-Respuesta a Droga , Masculino , Contracción Muscular/efectos de los fármacos , Contracción Muscular/fisiología , Fatiga Muscular/fisiología , Enfermedades de la Unión Neuromuscular/tratamiento farmacológico , Enfermedades de la Unión Neuromuscular/etiología , Enfermedades de la Unión Neuromuscular/fisiopatología , Oxígeno/sangre , Ratas , Ratas Sprague-Dawley , Respiración Artificial , Desconexión del Ventilador
9.
Am J Infect Control ; 48(7): 777-780, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31911069

RESUMEN

BACKGROUND: Controlling indoor air quality and the airborne transmission of infectious agents in hospitals is critical. The most hazardous particles and pathogens are not easily eliminated by traditionally passive air cleansing. METHODS: We studied the effect of a novel particle control technology on airborne particulate matter in 2 live real-world operating room settings and on pathogen survival in a microbiology laboratory. RESULTS: Particle control technology reduced operating room particle and pathogen loads by 94.4% in a community hospital operating room, and by 95% in an academic medical center operating room. The addition of particle control technology to a collector loaded with a biologic warfare surrogate resulted in a 95% kill rate of an anthrax surrogate (Bacillus subtilis) within 3 hours. DISCUSSION: Deployment of this emerging technology could significantly reduce indoor air contamination and associated infections in operating rooms, hospital isolation rooms, and intensive care settings, as well as reduce inflammatory responses to airborne particles. CONCLUSIONS: The particle control technology studied may protect patients from hospital-acquired infections, reduce inflammatory pulmonary disease, and mitigate exposure to biologic weapons.


Asunto(s)
Contaminación del Aire Interior , Guerra Biológica , Microbiología del Aire , Contaminación del Aire Interior/análisis , Filtración , Humanos , Quirófanos , Material Particulado
10.
J Surg Res ; 155(1): 77-81, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19181342

RESUMEN

INTRODUCTION: Hemostatic agents are frequently used during abdominal surgery and some are linked to adhesion formation. We sought to evaluate the impact of several commonly used hemostatic agents on adhesion formation in a rat peritoneal model. METHODS: In our study, Wister outbred rats underwent laparotomy and excision of a portion of their peritoneum to initiate adhesion formation process. One of six different hemostatic agents, namely, activated starch microspheres (Arista AH; Medafor Inc., Minneapolis, MN), glutaraldehyde activated collagen (BioGlue; Cryolife Inc., Kennesaw, GA), thrombin coated collagen microspheres (FloSeal; Baxter Inc., Deerfield, IL), thrombin activated fibrin polymer (Tisseel, Baxter), polyethylene glycol polymer (CoSeal, Baxter), or oxidized cellulose (Surgicel; Ethicon Inc., Somerville, NJ), was placed in the area of peritoneal defect. All animals were sacrificed on post-op day 7 and strength and extent of adhesion formation was determined. Histopathological examination of rat caecum was also performed. RESULTS: Arista and CoSeal showed significantly lower adhesion formation than controls (P < 0.05). Higher adhesion scores were seen in BioGlue (P < 0.05) treated rats. Additionally, histopathologic examination showed that BioGlue caused statistically more inflammation and necrosis than controls (P < 0.05). Total adhesion score increased with residual amount of agent present at 7 d. CONCLUSIONS: Use of Arista and CoSeal may help in reducing peritoneal adhesions after intra-abdominal surgeries. Furthermore, there appears to be a relationship between the creation of inflammation and necrosis in tissues and the eventual formation of adhesions. This could aid in improving the design of these agents in the future.


Asunto(s)
Enfermedades del Ciego/inducido químicamente , Hemostáticos/efectos adversos , Enfermedades Peritoneales/inducido químicamente , Almidón/efectos adversos , Adherencias Tisulares/inducido químicamente , Animales , Enfermedades del Ciego/patología , Inflamación/inducido químicamente , Inflamación/patología , Microesferas , Necrosis/inducido químicamente , Necrosis/patología , Enfermedades Peritoneales/patología , Polietilenglicoles/efectos adversos , Proteínas/efectos adversos , Ratas , Ratas Wistar , Adherencias Tisulares/patología
11.
12.
J Clin Anesth ; 19(6): 424-8, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17967670

RESUMEN

STUDY OBJECTIVE: To determine whether a new Sonoclot-based, aprotinin-insensitive activated clotting time (aiACT) assay yields stable results over a broad range of aprotinin concentrations. DESIGN: Prospective trial conducted on in vitro blood samples. SETTING: Tertiary-care teaching medical center. PARTICIPANTS: 19 healthy adult volunteers. INTERVENTIONS: Whole blood samples were collected from volunteers. Heparin (2 U/mL) and escalating concentrations of aprotinin of 160 to 500 kallikrein inhibitory units (KIU)/mL were added in vitro. MEASUREMENTS AND MAIN RESULTS: Celite ACT, kaolin ACT, and aiACT assays were completed. The aiACT showed stable activated clotting time (ACT) results on heparinized, noncitrated blood with added aprotinin (P = nonsignificant). In contrast, celite ACT and kaolin ACT were greatly prolonged when aprotinin was added to heparinized, noncitrated, and citrated blood (P < 0.05). The aiACT had consistent results at all aprotinin concentrations (P = nonsignificant). CONCLUSIONS: Aprotinin (160, 320, and 500 KIU/mL) significantly prolongs the ACT value with celite and kaolin activators but not with the aprotinin-insensitive activator.


Asunto(s)
Aprotinina/farmacología , Coagulación Sanguínea/efectos de los fármacos , Inhibidores de Serina Proteinasa/farmacología , Adulto , Puente Cardiopulmonar , Tierra de Diatomeas/farmacología , Humanos , Caolín/farmacología , Estudios Prospectivos , Tiempo de Coagulación de la Sangre Total
13.
Anesth Analg ; 103(4): 833-40, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17000789

RESUMEN

Fenoldopam, a selective dopamine-1-receptor agonist, decreases arterial blood pressure rapidly, with a brief duration of action similar to sodium nitroprusside (SNP), but in contrast to SNP, it increases renal blood flow. We compared the hemodynamic and renal effects of fenoldopam in patients undergoing abdominal aortic surgery requiring cross-clamping of the aorta with another therapeutic option, dopamine and SNP. Fenoldopam or 2 mcg x kg(-1) x min(-1) of dopamine and SNP was infused before incision in 60 randomly selected patients in a double-blind fashion. Hemodynamic variables were recorded before incision, immediately before clamping the aorta, 5 min after cross-clamp release and upon completion of surgery. Urine output, serum creatinine, and creatinine clearance were measured intraoperatively and postoperatively. Characteristics were compared between groups using two-sample rank sum test for continuous variables and Fisher's exact test for discrete variables. The occurrence of severe hypotension, maximum systolic blood pressure, and need for additional antihypertensive drugs were not different between the groups. Most intraoperative hemodynamic variables and all indices of renal function did not differ according to treatment. Therefore, fenoldopam has no therapeutic advantage compared with similar therapies in patients undergoing major vascular surgery involving cross-clamping of the aorta.


Asunto(s)
Antihipertensivos/uso terapéutico , Aorta Abdominal/cirugía , Dopamina/uso terapéutico , Fenoldopam/uso terapéutico , Nitroprusiato/uso terapéutico , Procedimientos Quirúrgicos Vasculares/métodos , Anciano , Anciano de 80 o más Años , Anestesia/métodos , Presión Sanguínea/efectos de los fármacos , Método Doble Ciego , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Riñón/irrigación sanguínea , Riñón/efectos de los fármacos , Masculino , Persona de Mediana Edad
14.
JSLS ; 10(3): 302-6, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17212884

RESUMEN

OBJECTIVES: We evaluated the efficacy of Microporous Polysaccharide Hemospheres (MPH) for parenchymal hemostasis during laparoscopic partial nephrectomy (LPN) in the porcine model. METHODS: Six female farm pigs underwent a transperitoneal right lower-pole LPN during occlusion of the renal hilum. Renal parenchyma was excised using cold Endoshears. MPH was applied to the defect and the hilar clamp released. Animals were kept alive for one week. Before sacrifice, left LPN was similarly performed using MPH. Study variables included blood loss, number of MPH applications, hilar clamp time, hemostasis time, perioperative complications, and abnormalities noted at sacrifice. RESULTS: Hemostasis was achieved in all kidneys solely by using MPH. The average excised specimen represented 5.6% (range, 3.6 to 8.5) of renal weight. Mean hilar clamp and hemostatic times were 12.8 minutes (range, 6 to 18) and 2 minutes (range, 1 to 3), respectively. Hemostasis occurred after one MPH application in 8 kidneys (67%). In 3 kidneys, additional MPH powder was required to treat minor residual bleeding. In the remaining kidney, a second standard MPH application was required for hemostasis. No operative complications were encountered. No hematomas or residual MPH was found at necropsy; however, small urinomas were found in 2 of 6 kidneys. CONCLUSIONS: In the experimental porcine model, this initial study suggests that MPH provides effective parenchymal hemostasis during laparoscopic resection of an exophytic kidney lesion.


Asunto(s)
Hemostasis Endoscópica/instrumentación , Nefrectomía , Polisacáridos/administración & dosificación , Animales , Pérdida de Sangre Quirúrgica/prevención & control , Femenino , Nefrectomía/métodos , Atención Perioperativa/métodos , Polvos , Porcinos , Factores de Tiempo
15.
Am Heart J ; 150(4): 796-9, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16209984

RESUMEN

BACKGROUND: The active metabolite of clopidogrel binds the P2Y12 ADP receptor on the platelet surface via a disulfide bond. N-Acetylcysteine (NAC) is able to reduce disulfide bonds. We postulated that NAC might reverse clopidogrel's effect on platelets. METHODS: Two groups of patients were investigated. Group 1 included 11 patients with stable coronary disease who, after discontinuation of aspirin, received 14 days of clopidogrel, 75 mg/day. Bleeding time and whole-blood platelet aggregometry (with 5 micromol/L ADP) were compared before and after the 14 days. Patients were then treated with 6 g of NAC orally, followed by repeat measurement of bleeding time and aggregometry. In group 2, 14 patients were treated with clopidogrel (300 mg) and aspirin before a percutaneous coronary intervention. Blood was drawn 22 +/- 3 hours later and divided into 2 samples. One was sent immediately for platelet-rich plasma aggregometry (using 5 and 2 micromol/L ADP, collagen, and arachidonic acid as agonists), thromboelastography, and aggregometry using the Plateletworks assay (Helena Laboratories, Beaumont, Tex). The other sample was treated with NAC (500 mg/L), after which these same platelet function tests were performed. RESULTS: In group 1, NAC therapy did not significantly change the bleeding time or results of aggregometry. In group 2, neither aggregometry nor the Plateletworks assay suggested reversal of inhibition by NAC. CONCLUSIONS: These studies reveal that a large dose of NAC does not reduce inhibition of platelet aggregation by clopidogrel in vitro or in vivo.


Asunto(s)
Acetilcisteína/farmacología , Inhibidores de Agregación Plaquetaria/farmacología , Agregación Plaquetaria/efectos de los fármacos , Ticlopidina/análogos & derivados , Clopidogrel , Interacciones Farmacológicas , Humanos , Estudios Prospectivos , Ticlopidina/antagonistas & inhibidores
16.
J Thorac Cardiovasc Surg ; 127(6): 1670-7, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15173722

RESUMEN

OBJECTIVES: Infants and children undergoing cardiopulmonary bypass for repair of congenital heart defects are at substantial risk for excessive bleeding, contributing greatly to morbidity and mortality. Aprotinin significantly reduces bleeding and transfusion requirements in adults but is of indeterminate value for pediatric patients. The aim of this study was to determine plasma aprotinin concentrations in these patients with a functional aprotinin assay. METHODS: Thirty patients less than 16 years of age scheduled for cardiac surgery with aprotinin were enrolled. Aprotinin was administered as a 25,000 KIU/kg bolus, 35,000 KIU/kg cardiopulmonary bypass prime, and 12,500 KIU.kg(-1).h(-1) continuous infusion. Blood samples for aprotinin concentrations (kallikrein-inhibiting units/milliliter) were obtained before aprotinin; 5 minutes post-bolus; 5 minutes after cardiopulmonary bypass initiation; 30 and 60 minutes on cardiopulmonary bypass; on discontinuation of aprotinin; 1 hour after aprotinin discontinuation; and 4 hours after permanent separation from cardiopulmonary bypass. For analysis, patients were grouped according to weight (<10 kg, 10-20 kg, >20 kg). Differences between weight groups were assessed using an exact test for categoric variables and 1-way analysis of variance for continuous variables. RESULTS: Aprotinin concentrations differed significantly across weight groups. Five minutes after aprotinin bolus and initiation of cardiopulmonary bypass, there was significant correlation between weight and aprotinin concentration (r =.57, P =.003; r =.69, P =.001, respectively). CONCLUSION: A functional assay reveals significant variability in aprotinin concentration for pediatric patients using current weight-based aprotinin dosing. Additional investigation is necessary to determine target aprotinin concentration dosing regimens to provide better efficacy.


Asunto(s)
Aprotinina/administración & dosificación , Aprotinina/farmacocinética , Pérdida de Sangre Quirúrgica/prevención & control , Puente Cardiopulmonar/métodos , Cardiopatías Congénitas/cirugía , Adolescente , Peso Corporal , Niño , Preescolar , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico , Humanos , Infusiones Intravenosas , Masculino , Monitoreo Intraoperatorio/métodos , Cuidados Preoperatorios/métodos , Probabilidad , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas , Resultado del Tratamiento
17.
Ann Thorac Surg ; 75(5): 1506-12, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12735570

RESUMEN

BACKGROUND: Infants and children undergoing cardiopulmonary bypass become substantially hemodiluted secondary to the volume used to prime the oxygenator. Fresh-frozen plasma has been included in the prime to lessen dilution of clotting factors and correspondingly minimize blood loss and transfusions. METHODS: We prospectively randomized 56 patients weighing 10 kg or less who required cardiopulmonary bypass to receive either one unit of fresh-frozen plasma or 200 mL of albumin 5% in the prime. After protamine administration, samples for prothrombin time, fibrinogen, platelet count, and thromboelastogram were obtained. Mediastinal chest tube drainage and transfusion requirements were documented. RESULTS: There were no significant differences between groups regarding demographic or surgical characteristics. Blood loss during the first 24 hours was similar in both groups, but total transfusions were significantly greater in those who received fresh-frozen plasma instead of albumin 5% in the prime (8.0 +/- 4.2 versus 6.1 +/- 4.5 U, respectively; p = 0.035). Post hoc analyses suggest that for cyanotic patients and patients undergoing complex operations, fresh-frozen plasma in the prime results in less blood loss than albumin 5%. CONCLUSIONS: Substitution of albumin 5% for fresh-frozen plasma in the prime of acyanotic patients weighing 10 kg or less who undergo noncomplex operations requiring cardiopulmonary bypass significantly reduces perioperative transfusions without increasing blood loss. Further investigation is needed to determine whether increased blood loss is associated with increased transfusions when albumin 5% is substituted for fresh-frozen plasma in the prime of infants and children who are cyanotic or undergoing complex operations.


Asunto(s)
Pérdida de Sangre Quirúrgica , Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Plasma , Albúmina Sérica/administración & dosificación , Pruebas de Coagulación Sanguínea , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Preescolar , Método Doble Ciego , Femenino , Hemoglobinas/análisis , Humanos , Lactante , Masculino , Estudios Prospectivos
18.
J Bone Joint Surg Am ; 86(9): 1983-8, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15342761

RESUMEN

BACKGROUND: Hip fractures are associated with a substantial mortality rate. Previous reports on perioperative mortality associated with hip arthroplasty for the treatment of acute fracture have not documented demographic and surgical characteristics that increase the likelihood of death. The purpose of the present study was to determine the prevalence of, and associated risk factors for, perioperative death following hip arthroplasty for the treatment of acute fracture. METHODS: Data were compiled from the computerized total joint registry at a single institution to determine the mortality rate following hip arthroplasty according to age, gender, diagnosis, implant type, and fixation mode. A review of this database revealed that 7774 consecutive patients had undergone hip arthroplasty for the treatment of an acute fracture between 1969 and 1997. The medical records of all patients who had died within thirty days after hip arthroplasty were reviewed retrospectively. RESULTS: The overall mortality rate within thirty days after hip arthroplasty for the treatment of an acute fracture was 2.4% (186 of 7774), yet notable variations in the mortality rate were seen within clinical subgroups. The thirty-day mortality rate was significantly higher for patients who had received a cemented implant, female patients, elderly patients, patients with cardiorespiratory comorbidities, and patients with intertrochanteric fractures. With the numbers available, there was no significant difference in mortality between patients who had been managed with total hip arthroplasty and those who had been managed with hemiarthroplasty. CONCLUSIONS: Hip arthroplasty for the diagnosis of acute fracture is associated with a nearly tenfold higher rate of perioperative mortality compared with elective hip arthroplasty. Medical optimization, appropriate choice of implants, and vigilant intraoperative management of these patients are essential.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas de Cadera/mortalidad , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Causas de Muerte , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
20.
Mayo Clin Proc ; 88(4): 354-9, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23541010

RESUMEN

OBJECTIVE: To determine whether the use of a computerized bar code-based blood identification system resulted in a reduction in transfusion errors or near-miss transfusion episodes. PATIENTS AND METHODS: Our institution instituted a computerized bar code-based blood identification system in October 2006. After institutional review board approval, we performed a retrospective study of transfusion errors from January 1, 2002, through December 31, 2005, and from January 1, 2007, through December 31, 2010. RESULTS: A total of 388,837 U were transfused during the 2002-2005 period. There were 6 misidentification episodes of a blood product being transfused to the wrong patient during that period (incidence of 1 in 64,806 U or 1.5 per 100,000 transfusions; 95% CI, 0.6-3.3 per 100,000 transfusions). There was 1 reported near-miss transfusion episode (incidence of 0.3 per 100,000 transfusions; 95% CI, <0.1-1.4 per 100,000 transfusions). A total of 304,136 U were transfused during the 2007-2010 period. There was 1 misidentification episode of a blood product transfused to the wrong patient during that period when the blood bag and patient's armband were scanned after starting to transfuse the unit (incidence of 1 in 304,136 U or 0.3 per 100,000 transfusions; 95% CI, <0.1-1.8 per 100,000 transfusions; P=.14). There were 34 reported near-miss transfusion errors (incidence of 11.2 per 100,000 transfusions; 95% CI, 7.7-15.6 per 100,000 transfusions; P<.001). CONCLUSION: Institution of a computerized bar code-based blood identification system was associated with a large increase in discovered near-miss events.


Asunto(s)
Seguridad de la Sangre/métodos , Transfusión Sanguínea/estadística & datos numéricos , Procesamiento Automatizado de Datos , Errores Médicos/prevención & control , Sistemas de Identificación de Pacientes , Etiquetado de Productos , Humanos , Errores Médicos/estadística & datos numéricos , Evaluación de Programas y Proyectos de Salud , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA