Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sci Rep ; 13(1): 21480, 2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38057401

RESUMEN

Bone quality is commonly used to diagnose bone diseases such as osteoporosis, with many studies focusing on microarchitecture for fracture prediction. In this study a bovine distal femur was imaged using both micro-computed tomography (µCT) and tomosynthesis using focal construct geometry (FCG) for comparison of microarchitectural parameters. Six regions of interest (ROIs) were compared between the two imaging modalities, with both global and adaptive methods used to binarize the images. FCG images were downsampled to the same pixel size as the µCT images. Bone morphometrics were determined using BoneJ, for each imaging modality, binarization technique and ROI. Bone area/total area was found to have few significant differences between FCG and µCT (p < 0.05 for two of six ROIs). Fractal Dimension had only one significant difference (p < 0.05 for one of six ROIs) between µCT and downsampled FCG (where pixel size was equalized). Trabecular thickness and trabecular spacing were observed to follow trends as observed for the corresponding µCT images, although many absolute values were significantly different (p < 0.05 for between one and six ROIs depending on image types used). This study demonstrates the utility of tomosynthesis for measurement of microarchitectural morphometrics.


Asunto(s)
Huesos , Osteoporosis , Animales , Bovinos , Microtomografía por Rayos X/métodos , Rayos X , Fémur/diagnóstico por imagen , Densidad Ósea
2.
Forensic Sci Int ; 220(1-3): 197-209, 2012 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-22436330

RESUMEN

This paper demonstrates a numerical pattern recognition method applied to curvilinear image structures. These structures are extracted from physical cross-sections of cast internal pistol barrel surfaces. Variations in structure arise from gun design and manufacturing method providing a basis for discrimination and identification. Binarised curvilinear land transition images are processed with fast Fourier transform on which principal component analysis is performed. One-way analysis of variance (95% confidence interval) concludes significant differentiation between 11 barrel manufacturers when calculating weighted Euclidean distance between any trio of land transitions and an average land transition for each barrel in the database. The proposed methodology is therefore a promising novel approach for the classification and identification of firearms.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA