RESUMEN

This report provides new CDC recommendations for tests that can support a diagnosis of syphilis, including serologic testing and methods for the identification of the causative agent Treponema pallidum. These comprehensive recommendations are the first published by CDC on laboratory testing for syphilis, which has traditionally been based on serologic algorithms to detect a humoral immune response to T. pallidum. These tests can be divided into nontreponemal and treponemal tests depending on whether they detect antibodies that are broadly reactive to lipoidal antigens shared by both host and T. pallidum or antibodies specific to T. pallidum, respectively. Both types of tests must be used in conjunction to help distinguish between an untreated infection or a past infection that has been successfully treated. Newer serologic tests allow for laboratory automation but must be used in an algorithm, which also can involve older manual serologic tests. Direct detection of T. pallidum continues to evolve from microscopic examination of material from lesions for visualization of T. pallidum to molecular detection of the organism. Limited point-of-care tests for syphilis are available in the United States; increased availability of point-of-care tests that are sensitive and specific could facilitate expansion of screening programs and reduce the time from test result to treatment. These recommendations are intended for use by clinical laboratory directors, laboratory staff, clinicians, and disease control personnel who must choose among the multiple available testing methods, establish standard operating procedures for collecting and processing specimens, interpret test results for laboratory reporting, and counsel and treat patients. Future revisions to these recommendations will be based on new research or technologic advancements for syphilis clinical laboratory science.


Asunto(s)
Sífilis , Humanos , Estados Unidos , Sífilis/diagnóstico , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum , Pruebas Serológicas , Centers for Disease Control and Prevention, U.S.
2.
BMC Infect Dis ; 24(Suppl 1): 194, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38418989

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) such as syphilis and HIV remain to be a significant public health issue worldwide. Dual rapid point-of-care tests (POCTs) have shown promise for detecting antibodies to HIV and syphilis but have not been fully evaluated in the field. Our study supported the WHO ProSPeRo study on Sexually Transmitted Infection Point-of-Care Testing (STI POCT) by providing external quality assessment (EQA) for HIV and syphilis testing in reference laboratories and their associated clinical sites in seven countries. METHODS: HIV/syphilis serum liquid and dried tube specimen (DTS) panels were prepared by CDC. Liquid panels were distributed to the reference laboratories for three rounds of testing using commercially and locally available laboratory-based serological tests. DTS panels were sent to the clinical testing sites for 8 rounds of POC testing using the Abbott SD BIOLINE HIV/Syphilis Duo test (hereafter referred to as SD BIOLINE) and the Chembio Dual Path Platform (DPP) HIV-Syphilis assay. EQA panels were tested at CDC using the Rapid Plasma Reagin (RPR) test and the Treponema pallidum Particle Agglutination assay (TP-PA) for syphilis antibodies. Genetic Systems HIV-1/HIV-2 Plus O EIA, Geenius HIV Supplemental Assay and the Oraquick Advance HIV test were used to detect HIV antibodies in the EQA panels. Results from the reference laboratories and POCT sites were compared to those obtained at the CDC and a percentage agreement was calculated. RESULTS: Qualitative RPR and TP-PA performed at the reference laboratories demonstrated 95.4-100% agreement with CDC results while quantitative RPR and TP-PA tests demonstrated 87.7% and 89.2% agreement, respectively. A 93.8% concordance rate was observed for qualitative HIV testing in laboratories. EQA testing at clinical sites using dual tests showed 98.7% and 99.1% agreement for detection of HIV antibodies and eight out of 10 sites had > 95.8% agreement for syphilis testing. However, two clinical sites showed only 65.0-66.7% agreement for SD BIOLINE and 84.0-86.7% for DPP, respectively, for syphilis testing. CONCLUSIONS: Overall, laboratories demonstrated high EQA performance in this study. Both HIV/syphilis POCTs gave expected results in the clinic-based evaluations using DTS. However, testing errors were identified in a few testing sites suggesting the necessity for continuous training and monitoring the quality of POC testing.


Asunto(s)
Infecciones por VIH , VIH-1 , Sífilis , Humanos , Treponema pallidum , Anticuerpos Anti-VIH , Infecciones por VIH/diagnóstico , Sensibilidad y Especificidad , Anticuerpos Antibacterianos , Pruebas en el Punto de Atención , Serodiagnóstico de la Sífilis/métodos , VIH-2 , Organización Mundial de la Salud , Sistemas de Atención de Punto
3.
J Clin Microbiol ; 61(6): e0016823, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37219422

RESUMEN

Automated nontreponemal rapid plasma reagin (RPR) tests were recently introduced in the United States for syphilis testing and limited performance data are available. In collaboration with the Association of Public Health Laboratories, three public health laboratories (PHL) were chosen through a competitive selection process to evaluate the performance of three FDA-cleared automated RPR test systems: BioPlex 2200 Syphilis Total & RPR assay (Bio-Rad Laboratories), AIX 1000 (Gold Standard Diagnostics), and ASI Evolution (Arlington Scientific). Panels prepared at the CDC included: a qualitative panel comprised of 734 syphilis reactive/nonreactive sera; a quantitative panel of 50 syphilis reactive sera (RPR titer 1:64 to 1:1,024); and a reproducibility panel of 15 nonreactive and reactive sera (RPR titer 1:1 to 1:64). Panels were shipped frozen to the PHL and tested on the automated RPR systems following manufacturers' instructions. Prior test results were blinded to all laboratories. When compared to manual RPR (Arlington Scientific) performed at the CDC as a reference test, the qualitative panel results demonstrated an overall concordance of 95.9% for AIX 1000, 94.6% for ASI Evolution, and 92.6% for Bioplex RPR; quantitative panel showed within range titer of 2-fold for 94% of specimens for AIX 1000, 68% for ASI Evolution, and 64% for BioPlex RPR, and the reproducibility testing panel demonstrated point estimates ranging from 69 to 95%. Automated RPR instruments could reduce turnaround time and minimize interpretation errors. However, additional evaluations with more specimens could assist laboratories with implementing automated RPR tests and understanding their limitations.


Asunto(s)
Sífilis , Humanos , Sífilis/diagnóstico , Reaginas , Reproducibilidad de los Resultados , Anticuerpos Antibacterianos , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum
4.
J Clin Microbiol ; 60(5): e0234821, 2022 05 18.
Artículo en Inglés | MEDLINE | ID: mdl-35387497

RESUMEN

Diagnostic assays that can simultaneously determine the presence of infection with multiple pathogens are key for diagnosis and surveillance. Current multiplex diagnostic assays are complex and often have limited availability. We developed a simple, multianalyte, pathogen detection assay for screening and serosurveillance using the Luminex Magpix platform that is high throughput and can be helpful in monitoring multiple diseases. The Luminex bead-based 10-plex immunoassay for the detection of HIV-1, HIV-2, Treponema pallidum, hepatitis B virus (HBV), hepatitis C virus (HCV), herpes simplex virus 1 (HSV-1), and HSV-2 infections was accomplished by coupling beads with specific antigens to detect IgG antibodies in plasma or serum samples. Each coupled antigen was systematically optimized, and the performance was evaluated using a panel of well-characterized specimens (n = 417) that contained antibodies to HIV-1, HIV-2, T. pallidum, HBV, HCV, HSV-1, and HSV-2. The multiplex assay had a sensitivity of 92.2% (95% Clopper-Pearson confidence interval [CI], 90.2 to 94.0%) and a specificity of 98.1% (95% CI, 97.6 to 98.7%). The sensitivities and specificities for disease-specific biomarker detection ranged from 68.7 to 100% and 95.6 to 100%, respectively. The results showed that the 10-plex immunoassay had an overall agreement of 96.7% (95% CI, 96.7 to 97.3%) with reference tests and a corresponding kappa value of 0.91 (95% CI, 0.90 to 0.93). Kappa values for the individual pathogens ranged from 0.69 to 1.00. The assay is robust and allows the simultaneous detection of antibodies to multiple antigens using a small sample volume in a high-throughput format. This assay has the potential to simplify disease surveillance by providing an alternative to expensive and highly specialized individual tests.


Asunto(s)
Infecciones por VIH , VIH-1 , Hepatitis C , Herpes Simple , Sífilis , VIH-2 , Hepacivirus , Virus de la Hepatitis B , Hepatitis C/diagnóstico , Herpes Simple/diagnóstico , Humanos , Sensibilidad y Especificidad , Sífilis/diagnóstico , Sífilis/epidemiología , Treponema pallidum
5.
Clin Infect Dis ; 71(Suppl 1): S13-S20, 2020 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-32578866

RESUMEN

We conducted a systematic review of relevant syphilis diagnostic literature to address the question, "What is the sensitivity and specificity of the treponemal tests currently approved by the Food and Drug Administration (FDA) for the diagnosis of syphilis (by stage)?" There were 16 treponemal assays evaluated: 13 immunoassays and 3 manual assays (fluorescent treponemal antibody absorbed test [FTA-ABS], microhemagglutination assay for Treponema pallidum antibodies [MHA-TP], Treponema pallidum particle agglutination assay [TP-PA]). MHA-TP and FTA-ABS were less sensitive in primary and secondary syphilis than TP-PA; TP-PA is the most specific manual treponemal assay. There is insufficient evidence to recommend one particular treponemal immunoassay (eg, enzyme immunoassays, chemiluminescence immunoassays, microbead immunoassays) over another based on published performance data. For diagnosis of neurosyphilis, cerebrospinal fluid (CSF) TP-PA has similar performance to CSF FTA-ABS in studies with patients with definitive or presumptive neurosyphilis. However, CSF treponemal testing has limitations in its sensitivity and specificity and should be interpreted within the context of the clinical scenario, additional CSF test results and syphilis prevalence.


Asunto(s)
Neurosífilis , Sífilis , Anticuerpos Antibacterianos , Humanos , Sensibilidad y Especificidad , Sífilis/diagnóstico , Serodiagnóstico de la Sífilis , Treponema pallidum
6.
J Clin Microbiol ; 58(6)2020 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-32238434

RESUMEN

Measurement of measles virus-specific IgG is used to assess presumptive evidence of immunity among immunocompetent individuals with uncertain immune or vaccination status. False-negative test results may lead to unnecessary quarantine and exclusion from activities such as employment, education, and travel or result in unnecessary revaccination. In contrast, false-positive results may fail to identify susceptible individuals and promote spread of disease by those who are exposed and unprotected. To better understand the performance characteristics of tests to detect measles IgG, we compared five widely used, commercially available measles IgG test platforms using a set of 223 well-characterized serum samples. Measles virus neutralizing antibodies were also measured by in vitro plaque reduction neutralization, the gold standard method, and compared to IgG test results. Discrepant results were observed for samples in the low-positive ranges of the most sensitive tests, but there was good agreement across platforms for IgG-negative sera and for samples with intermediate to high levels of IgG. False-negative test results occurred in approximately 11% of sera, which had low levels of neutralizing antibody.


Asunto(s)
Virus del Sarampión , Sarampión , Anticuerpos Antivirales , Ensayo de Inmunoadsorción Enzimática , Humanos , Inmunoensayo , Inmunoglobulina G , Sarampión/diagnóstico , Pruebas de Neutralización , Sensibilidad y Especificidad
7.
Sex Transm Infect ; 96(6): 411-416, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32376729

RESUMEN

OBJECTIVES: Serological tests of non-treponemal and treponemal types are the most frequently used for syphilis diagnosis. Treponemal tests are available in wide variety of assay formats; however, limited advances have been made for the improvement of conventional non-treponemal tests. The objective of this work was to develop a novel non-treponemal magnetic particle-based agglutination assay (NT-MAA) and evaluate its feasibility for syphilis testing. METHODS: Cardiolipin was modified and coupled to magnetic microbeads. Serum diluted in phosphate-buffered saline was mixed with cardiolipin-coupled beads and incubated in a round bottom microplate for 90-120 min followed by visual inspection. A panel of reported syphilis (n=127) and non-reactive (n=244) specimens was prepared to evaluate the NT-MAA performance in comparison to conventional rapid plasma reagin (RPR). Treponema pallidum particle agglutination (TP-PA) assay and enzyme immunoassay (EIA) were included. Analytical sensitivity and reproducibility of NT-MAA were also determined. RESULTS: The non-treponemal NT-MAA and RPR showed sensitivity of 90.6% and 88.2% and specificity of 96.7% and 100%, respectively. The treponemal TP-PA and EIA yielded sensitivity of 100% and 99.2%, respectively, and 100% specificity by both assays. The per cent agreement between NT-MAA and RPR was 97% (kappa=0.931, 95% CI 0.891 to 0.971). Analytical sensitivity determined with IgM anticardiolipin antibody (ACA) was 2.6 µg/mL for both NT-MAA and RPR, while IgG ACA yielded 0.9 µg/mL and 1.7 µg/mL for NT-MAA and RPR, respectively. Qualitative results of intra-assay and interassay reproducibility revealed 100% consistency for NT-MAA. CONCLUSION: Preliminary evaluation of the novel NT-MAA validated proof of concept using laboratory-characterised syphilis sera and demonstrated performance comparable to RPR. Further validation of NT-MAA using additional specimens with better clinical staging may broaden the scope of developed test for syphilis diagnosis.


Asunto(s)
Pruebas de Aglutinación/métodos , Anticuerpos Anticardiolipina/inmunología , Sífilis/diagnóstico , Estudios de Casos y Controles , Cromatografía de Afinidad , Estudios de Factibilidad , Humanos , Inmunoensayo , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Imanes , Sensibilidad y Especificidad , Sífilis/inmunología
8.
Clin Infect Dis ; 68(6): 913-918, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-29986091

RESUMEN

BACKGROUND: Treponemal immunoassays are increasingly used for syphilis screening with the reverse sequence algorithm. There are few data describing performance of treponemal immunoassays compared to traditional treponemal tests in patients with and without syphilis. METHODS: We calculated sensitivity and specificity of 7 treponemal assays: (1) ADVIA Centaur (chemiluminescence immunoassay [CIA]); (2) Bioplex 2200 (microbead immunoassay); (3) fluorescent treponemal antibody absorption test (FTA-ABS); (4) INNO-LIA (line immunoassay); (5) LIAISON CIA; (6) Treponema pallidum particle agglutination assay (TPPA); and (7) Trep-Sure (enzyme immunoassay [EIA]), using a reference standard combining clinical diagnosis and serology results. Sera were collected between May 2012-January 2013. Cases were characterized as: (1) current clinical diagnosis of syphilis: primary, secondary, early latent, late latent; (2) prior treated syphilis only; (3) no evidence of current syphilis, no prior history of syphilis, and at least 4 of 7 treponemal tests negative. RESULTS: Among 959 participants, 262 had current syphilis, 294 had prior syphilis, and 403 did not have syphilis. FTA-ABS was less sensitive for primary syphilis (78.2%) than the immunoassays or TPPA (94.5%-96.4%) (all P ≤ .01). All immunoassays were 100% sensitive for secondary syphilis, 95.2%-100% sensitive for early latent disease, and 86.8%-98.5% sensitive in late latent disease. TPPA had 100% specificity. CONCLUSIONS: Treponemal immunoassays demonstrated excellent sensitivity for secondary, early latent, and seropositive primary syphilis. Sensitivity of FTA-ABS in primary syphilis was poor. Given its high specificity and superior sensitivity, TPPA is preferred to adjudicate discordant results with the reverse sequence algorithm over the FTA-ABS.


Asunto(s)
Inmunoensayo , Serodiagnóstico de la Sífilis , Sífilis/diagnóstico , Sífilis/microbiología , Treponema pallidum , Adulto , Algoritmos , Coinfección , Femenino , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Sífilis/epidemiología , Serodiagnóstico de la Sífilis/métodos , Serodiagnóstico de la Sífilis/normas , Treponema pallidum/inmunología
9.
Sex Transm Dis ; 46(4): 250-253, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30628945

RESUMEN

BACKGROUND: In this study, we evaluate the performance of the Syphilis Health Check (SHC) in clinical and laboratory settings using fingerstick whole blood and serum. METHODS: Fingerstick whole blood and serum specimens from adult patients (n = 562) without prior syphilis history presenting at 2 county health department STD clinics in North Carolina were tested. Fingerstick specimens were tested with the SHC in clinic, and serum specimens were tested at the North Carolina State Laboratory of Public Health with: (1) qualitative rapid plasma reagin, (2) treponemal EIA, and (3) SHC. Sensitivity and specificity were calculated with 95% confidence intervals. RESULTS: The fingerstick whole blood had a sensitivity of 100% (7 of 7) and specificity of 95.7% (531 of 555), compared with consensus reference testing (CRT) (rapid plasma reagin and EIA reactive), but a sensitivity of 50% (8 of 16), and specificity of 95.9% (523 of 546), when compared with the treponemal EIA. Both laboratory-based SHC on serum and whole-blood SHC performed similarly, compared with CRT, and the treponemal EIA alone. Twenty-four specimens SHC reactive on whole blood were nonreactive by CRT. In 8 of these 24 cases, STD clinic staff reported difficulty reading the test line for the SHC. Of the fingerstick whole-blood SHC reactive specimens, only 14 of 31 were also serum SHC reactive. CONCLUSIONS: The SHC on whole blood appears to be sensitive at detecting patients likely to have syphilis and could be an option for testing among high-risk populations. However, given challenges in interpreting SHC test results, adequate training of persons performing testing and ongoing quality assurance measures are key.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Serodiagnóstico de la Sífilis/normas , Sífilis/diagnóstico , Adulto , Algoritmos , Instituciones de Atención Ambulatoria/estadística & datos numéricos , Femenino , Humanos , Masculino , North Carolina , Sensibilidad y Especificidad , Sífilis/sangre , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum , Adulto Joven
10.
Sex Transm Dis ; 46(7): 429-433, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30839394

RESUMEN

BACKGROUND: Syphilis transmission can be prevented by prompt diagnosis and treatment of primary and secondary infection. We evaluated the performance of a point-of-care rapid syphilis treponemal (RST) test in an emergency department (ED) setting. METHODS: Between June 2015 and April 2016, men aged 18 to 34 years seeking services in a Detroit ED, and with no history of syphilis, were screened for syphilis with the RST test, rapid plasma reagin (RPR) test, and Treponema pallidum particle agglutination assay (TP-PA). A positive reference standard was both a reactive RPR and a reactive TP-PA. We compared test results in self-reported men who have sex with men (MSM) to non-MSM. RESULTS: Among 965 participants, 10.9% of RST tests were reactive in MSM and only 1.5% in non-MSM (P < 0.001). Sensitivity of the RST test was 76.9% and specificity was 99.0% (positive predictive value, 50.0%) compared with the positive reference standard. Three discordant specimens found negative with the RST test but positive with the reference standard had an RPR titer of 1:1, compared with 10 specimens with concordant positive results that had a median RPR titer of 1:16. The RST sensitivity was 50.0% (positive predictive value, 68.4%) compared to the TP-PA test alone. Among men seeking care in an ED, the RST detected 76.9% of participants with a reactive RPR and TP-PA. CONCLUSIONS: The RST test detected all of the participants with an RPR titer ≥1:2 but less than 20% of participants with a positive TP-PA and negative RPR. The RST test was useful to detect a high proportion of participants with an active syphilis in an urban ED.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Reaginas/sangre , Sífilis/diagnóstico , Treponema pallidum/inmunología , Adolescente , Adulto , Pruebas de Aglutinación , Servicio de Urgencia en Hospital , Humanos , Masculino , Michigan/epidemiología , Pruebas en el Punto de Atención , Sensibilidad y Especificidad , Minorías Sexuales y de Género , Sífilis/epidemiología , Sífilis/microbiología , Serodiagnóstico de la Sífilis , Factores de Tiempo , Treponema pallidum/aislamiento & purificación , Adulto Joven
11.
J Infect Dis ; 217(7): 1139-1144, 2018 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-29309603

RESUMEN

Among men who have sex with men (MSM), those with a diagnosis of syphilis or other rectal sexually transmitted infections (STIs) are at a higher risk for human immunodeficiency virus acquisition, which is concerning given the large increase in recently reported syphilis cases in the United States. We have developed the first nonhuman primate model for rectally transmitted syphilis by exposing simian/human immunodeficiency virus-infected and naive rhesus macaques to Treponema pallidum in the rectum. All animals showed mucosal lesions, systemic dissemination, and seroconversion (treponemal antibodies). This model would be valuable for studying the manifestations of and interventions for T. pallidum infection, with and without human immunodeficiency virus coinfection.


Asunto(s)
Macaca mulatta , Síndrome de Inmunodeficiencia Adquirida del Simio/complicaciones , Sífilis/transmisión , Animales , Linfocitos T CD4-Positivos , Coinfección , Modelos Animales de Enfermedad , Femenino , Masculino , Péptidos Cíclicos , Recto , Enfermedades de Transmisión Sexual , Virus de la Inmunodeficiencia de los Simios , Treponema pallidum , Viremia
12.
J Clin Microbiol ; 56(10)2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30021825

RESUMEN

Serological diagnosis of syphilis depends on assays that detect treponemal and nontreponemal antibodies. Laboratory certification and trained personnel are needed to perform most of these tests, while high costs and long turnaround time can hinder treatment initiation or linkage to care. A rapid treponemal syphilis test (RST) that is simple to perform, accessible, and inexpensive would be ideal. The Syphilis Health Check (SHC) assay is the only Food and Drug Administration (FDA)-cleared and Clinical Laboratory Improvement Amendments (CLIA)-waived RST in the United States. In this study, 1,406 archived human serum samples were tested using SHC and traditional treponemal and nontreponemal assays. Rapid test results were compared with treponemal data alone and with a laboratory test panel consensus defined as being reactive by both treponemal and nontreponemal assays for a given specimen, or nonreactive by both types of assays. The sensitivity and specificity of the SHC assay compared with treponemal tests alone were 88.7% (95% confidence interval [CI], 86.2 to 90.0%) and 93.1% (95% CI, 90.0 to 94.9%), respectively, while comparison with the laboratory test panel consensus showed 95.7% (95% CI, 93.6 to 97.2%) sensitivity and 93.2% (95% CI, 91.0 to 95.1%) specificity. The data were further stratified based on age, sex, pregnancy, and HIV status. The sensitivity and specificity of the SHC assay ranged from 66.7% (95% CI, 46.0 to 83.5%) to 91.7% (95% CI, 87.7 to 94.7%) and 88% (95% CI, 68.8 to 97.5%) to 100% (95% CI, 47.8 to 100%), respectively, across groups compared to traditional treponemal assays, generally increasing for all groups except the HIV-positive (HIV+) population when factoring in the laboratory test panel consensus. These data contribute to current knowledge of the SHC assay performance for distinct populations and may guide use in various settings.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , Pruebas Diagnósticas de Rutina/métodos , Sífilis/diagnóstico , Treponema pallidum/aislamiento & purificación , Anticuerpos Antibacterianos/sangre , Técnicas de Laboratorio Clínico/normas , Pruebas Diagnósticas de Rutina/normas , Femenino , Humanos , Masculino , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Sífilis/sangre , Serodiagnóstico de la Sífilis , Factores de Tiempo , Treponema pallidum/inmunología
13.
J Clin Microbiol ; 56(1)2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29046410

RESUMEN

Automated treponemal immunoassays are used for syphilis screening with the reverse-sequence algorithm; discordant results (e.g., enzyme immunoassay [EIA] reactive and reactive plasma reagin [RPR] nonreactive) are resolved with a second treponemal test. We conducted a study to determine automated immunoassay signal strength values consistently correlating with reactive confirmatory treponemal testing. We conducted a cross-sectional analysis of four automated immunoassays (BioPlex 2200 microbead immunoassay [MBIA], Liaison chemiluminescence immunoassay [CIA], Advia-Centaur CIA, and Trep-Sure EIA) and three manual assays (Treponema pallidum particle agglutination [TP-PA], fluorescent treponemal antibody absorption [FTA-ABS] test, and Inno-LIA line immunoassay). We compared signal strength values of automated immunoassays and positive and negative agreement. Among 1,995 specimens, 908 (45.5%) were true positives (≥4/7 tests reactive) and 1,087 (54.5%) were true negatives (≥4/7 tests nonreactive). Positive agreement ranged from 86.1% (83.7 to 88.2%) for FTA-ABS to 99.7% (99.0 to 99.9%) for Advia-Centaur CIA; negative agreement ranged from 86.3% (84.1 to 88.2%) for Trep-Sure EIA to 100% for TP-PA (99.6 to 100%). Increasing signal strength values correlated with increasing reactivity of confirmatory testing (P < 0.0001 for all automated immunoassays by Cochran-Armitage test for trend). All automated immunoassays had signal strength cutoffs corresponding to ≥4/7 reactive treponemal tests. BioPlex MBIA and Liaison CIA had signal strength cutoffs correlating with ≥99% and 100% TP-PA reactivity, respectively. The Advia-Centaur CIA and Trep-Sure EIA had signal strength cutoffs correlating with at least 95% TP-PA reactivity. All automated immunoassays had signal strength cutoffs correlating with at least 95% FTA-ABS reactivity. Assuming that a 95% level of confirmation is adequate, these signal strength values can be used in lieu of confirmatory testing with TP-PA and FTA-ABS.


Asunto(s)
Inmunoensayo , Tamizaje Masivo/métodos , Serodiagnóstico de la Sífilis/métodos , Sífilis/diagnóstico , Algoritmos , Anticuerpos Antibacterianos/sangre , Estudios Transversales , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sífilis/sangre , Sífilis/inmunología , Treponema pallidum/inmunología
14.
J Infect Dis ; 210(8): 1239-47, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-24755433

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) are associated with an increased risk of human immunodeficiency virus (HIV) infection, but their biological effect on HIV susceptibility is not fully understood. METHODS: Female pig-tailed macaques inoculated with Chlamydia trachomatis and Trichomonas vaginalis (n = 9) or medium (controls; n = 7) were repeatedly challenged intravaginally with SHIVSF162p3. Virus levels were evaluated by real-time polymerase chain reaction, plasma and genital cytokine levels by Luminex assays, and STI clinical signs by colposcopy. RESULTS: Simian/HIV (SHIV) susceptibility was enhanced in STI-positive macaques (P = .04, by the log-rank test; relative risk, 2.5 [95% confidence interval, 1.1-5.6]). All STI-positive macaques were SHIV infected, whereas 3 controls (43%) remained uninfected. Moreover, relative to STI-negative animals, SHIV infections occurred earlier in the menstrual cycle in STI-positive macaques (P = .01, by the Wilcoxon test). Levels of inflammatory cytokines (interferon γ, interleukin 6, and granulocyte colony-stimulating factor [G-CSF]) were higher in STI-positive macaques during STI inoculation and SHIV exposure periods (P ≤ .05, by the Wilcoxon test). CONCLUSIONS: C. trachomatis and T. vaginalis infection increase the susceptibility to SHIV, likely because of prolonged genital tract inflammation. These novel data demonstrate a biological link between these nonulcerative STIs and the risk of SHIV infection, supporting epidemiological associations of HIV and STIs. This study establishes a macaque model for studies of high-risk HIV transmission and prevention.


Asunto(s)
Infecciones por Chlamydia/complicaciones , Chlamydia trachomatis , Coinfección/inmunología , Virus de la Inmunodeficiencia de los Simios/fisiología , Vaginitis por Trichomonas/complicaciones , Trichomonas vaginalis , Animales , Cuello del Útero/microbiología , Cuello del Útero/parasitología , Cuello del Útero/patología , Colposcopía , Femenino , Macaca nemestrina , Factores de Riesgo , Enfermedades de Transmisión Sexual/complicaciones , Síndrome de Inmunodeficiencia Adquirida del Simio/transmisión , Síndrome de Inmunodeficiencia Adquirida del Simio/virología
15.
Clin Microbiol Newsl ; 36(24): 195-202, 2014 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-28845073

RESUMEN

Syphilis is a human infection of global importance. Its diagnosis can be challenging, requiring construction of a serologic profile based on the results of at least two types of antibody tests: treponemal and nontreponemal. The traditional approach to the serodiagnosis of syphilis has been the use of a nontreponemal screening assay followed by the performance of a treponemal confirmatory test if the initial nontreponemal screening test was reactive. With the increasing availability of automated, easier-to-perform, and rapid treponemal assays, an increasing number of laboratory testing sites are adopting reverse sequence screening for the serodiagnosis of syphilis: screening with a treponemal assay first, then confirmation with a nontreponemal assay and, when necessary, discrepant resolution using another treponemal test. In addition to offering automation and increased throughput, a reverse algorithm can increase disease detection, especially in late latent and early primary stages of infection when the nontreponemal antibody test may be nonreactive. However, a disadvantage to this approach is that there can be an increase in false-positive test results. This article reviews the clinical and workflow benefits and limitations of a reverse testing algorithm and discusses current guidance available from the Centers for Disease Control and Prevention.

16.
Diagn Microbiol Infect Dis ; 102(2): 115588, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34883351

RESUMEN

The effect of extended refrigerated storage of 14 serum and plasma specimens on 5 syphilis serologic tests was evaluated for 16 weeks. Higher stability of nontreponemal and treponemal antibodies in serum was recorded compared to plasma. Described work may provide insights on refrigerated specimens' stability and suitability for syphilis tests.


Asunto(s)
Anticuerpos Antibacterianos/análisis , Anticuerpos Antibacterianos/sangre , Refrigeración/métodos , Manejo de Especímenes/métodos , Serodiagnóstico de la Sífilis/métodos , Sífilis/sangre , Sífilis/diagnóstico , Sífilis/microbiología , Humanos , Plasma/microbiología , Suero/microbiología
17.
JMIR Res Protoc ; 11(11): e40095, 2022 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-36331528

RESUMEN

BACKGROUND: In the United States, the rates of primary and secondary syphilis have increased more rapidly among men who have sex with men (MSM) than among any other subpopulation. Rising syphilis rates among MSM reflect changes in both individual behaviors and the role of sexual networks (eg, persons linked directly or indirectly by sexual contact) in the spread of the infection. Decades of research examined how sexual networks influence sexually transmitted infections (STIs) among MSM; however, few longitudinal data sources focusing on syphilis have collected network characteristics. The Centers for Disease Control and Prevention, in collaboration with 3 sites, enrolled a prospective cohort of MSM in 3 US cities to longitudinally study sexual behaviors and STIs, including HIV, for up to 24 months. OBJECTIVE: The Network Epidemiology of Syphilis Transmission (NEST) study aimed to collect data on the factors related to syphilis transmission and acquisition among MSM. METHODS: The NEST study was a prospective cohort study that enrolled 748 MSM in Baltimore, Maryland; Chicago, Illinois; and Columbus, Ohio. NEST recruitment used a combination of convenience sampling, venue-based recruitment, and respondent-driven sampling approaches. At quarterly visits, participants completed a behavioral questionnaire and were tested for syphilis, HIV, gonorrhea, and chlamydia. The participants also provided a list of their sexual partners and described their 3 most recent partners in greater detail. RESULTS: The NEST participants were enrolled in the study from July 2018 to December 2021. At baseline, the mean age of the participants was 31.5 (SD 9.1) years. More than half (396/727. 54.5%) of the participants were non-Hispanic Black, 29.8% (217/727) were non-Hispanic White, and 8.8% (64/727) were Hispanic or Latino. Multiple recruitment strategies across the 3 study locations, including respondent-driven sampling, clinic referrals, flyers, and social media advertisements, strengthened NEST participation. Upon the completion of follow-up visits in March 2022, the mean number of visits per participant was 5.1 (SD 3.2; range 1-9) in Baltimore, 2.2 (SD 1.6; range 1-8) in Chicago, and 7.2 (SD 2.9; range 1-9) in Columbus. Using a community-based participatory research approach, site-specific staff were able to draw upon collaborations with local communities to address stigma concerning STIs, particularly syphilis, among potential NEST participants. Community-led efforts also provided a forum for staff to describe the NEST study objectives and plans for research dissemination to the target audience. Strategies to bolster data collection during the COVID-19 pandemic included telehealth visits (all sites) and adaptation to self-collection of STI specimens (Baltimore only). CONCLUSIONS: Data from NEST will be used to address important questions regarding individual and partnership-based sexual risk behaviors among MSM, with the goal of informing interventions to prevent syphilis in high-burden areas. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/40095.

19.
J Med Primatol ; 40(4): 214-23, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21781129

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) are associated with an increased risk of HIV infection. To model the interaction between STIs and HIV infection, we evaluated the capacity of the pigtail macaque model to sustain triple infection with Trichomonas vaginalis, Chlamydia trachomatis, and SHIV(SF162P3). METHODS: Seven SHIV(SF162P3) -infected pigtail macaques were inoculated with T. vaginalis only (n = 2), C. trachomatis only (n = 1), both T. vaginalis and C. trachomatis (n = 2), or control media (no STI; n = 2). Infections were confirmed by culture and/or nucleic acid testing. Genital mucosa was visualized by colposcopy. RESULTS: Characteristic gynecologic signs were observed for both STIs, but not in control animals. Manifestations were most prominent at days 7-10 post-infection. STIs persisted between 4 and 6 weeks and were cleared with antibiotics. CONCLUSIONS: These pilot studies demonstrate the first successful STI-SHIV triple infection of pigtail macaques, with clinical presentation of genital STI symptoms similar to those observed in humans.


Asunto(s)
Infecciones por Chlamydia/patología , Modelos Animales de Enfermedad , Infecciones por VIH/complicaciones , Enfermedades de Transmisión Sexual/complicaciones , Síndrome de Inmunodeficiencia Adquirida del Simio/complicaciones , Vaginitis por Trichomonas/patología , Animales , Cuello del Útero/microbiología , Cuello del Útero/parasitología , Cuello del Útero/patología , Infecciones por Chlamydia/sangre , Infecciones por Chlamydia/complicaciones , Chlamydia trachomatis , Colposcopía , Femenino , Infecciones por VIH/sangre , Infecciones por VIH/virología , Macaca nemestrina , Proyectos Piloto , Enfermedades de Transmisión Sexual/sangre , Enfermedades de Transmisión Sexual/microbiología , Enfermedades de Transmisión Sexual/parasitología , Síndrome de Inmunodeficiencia Adquirida del Simio/sangre , Virus de la Inmunodeficiencia de los Simios , Vaginitis por Trichomonas/sangre , Vaginitis por Trichomonas/complicaciones , Trichomonas vaginalis , Enfermedades del Cuello del Útero/sangre , Enfermedades del Cuello del Útero/complicaciones , Enfermedades del Cuello del Útero/microbiología , Enfermedades del Cuello del Útero/parasitología , Vagina/microbiología , Vagina/parasitología , Vagina/patología
20.
BMJ Open ; 10(1): e029434, 2020 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-31924629

RESUMEN

OBJECTIVES: Syphilis morbidity is high among pregnant women in lower income countries with limited laboratory capacity. We evaluated a long-standing global Syphilis Serology Proficiency Programme (SSPP) that supports testing quality in national reference laboratories to determine if participation affects congenital syphilis elimination strategies. DESIGN: In this observational cross-sectional study, we calculated coverage on type, frequency and quality of syphilis testing reported by laboratories enrolled in the SSPP from 2008 to 2015. We used country-reported data to WHO on four congenital syphilis (CS) indicators and World Bank country economic data to compare coverage and completeness of reporting of indicators in lower income countries with and without an SSPP-enrolled laboratory. PARTICIPANTS: From 2008-2015, 78 laboratories from 51 countries participated in >1 SSPP evaluation; 56% were national reference laboratories, of which most (93%) participated for >3 years and 11 (22%) in all 24 cycles. RESULTS: Median proficiency performance score was >95% regardless of test conducted. Of the 51 countries with an SSPP-enrolled laboratory, 22 (43%) were lower-income countries, of which 21 reported CS data during 2008-2015. Comparing CS data from 87 (90% of total) lower income countries with and without an SSPP-enrolled laboratory, countries with an SSPP-laboratory had stronger reporting on antenatal syphilis testing (p=0.04). For 2015, an estimated 74% of prenatal syphilis tests and 63% of positive tests reported to WHO from countries with an SSPP-enrolled laboratory. CONCLUSION: The SSPP has focused well on national reference laboratories, but has been only partially successful in recruiting laboratories from lower income countries. The finding that over half of syphilis infections in pregnant women living in countries with SSPP-enrolled laboratories suggests wide reach of the current quality assurance programme. However, reach could expand with focussed recruitment of laboratories from lower income countries.


Asunto(s)
Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Complicaciones Infecciosas del Embarazo/diagnóstico , Atención Prenatal/métodos , Diagnóstico Prenatal/métodos , Sífilis/diagnóstico , Adulto , Niño , Estudios Transversales , Femenino , Humanos , Incidencia , Masculino , Embarazo , Complicaciones Infecciosas del Embarazo/epidemiología , Estudios Retrospectivos , Sífilis/prevención & control , Sífilis/transmisión , Serodiagnóstico de la Sífilis/métodos , Estados Unidos/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA