Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Scand J Clin Lab Invest ; 73(3): 262-4, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23402665

RESUMEN

Classic immunohematology approaches, based on agglutination techniques, have been used in manual and automated immunohematology laboratory routines. Red blood cell (RBC) agglutination depends on intermolecular attractive forces (hydrophobic bonds, Van der Walls, electrostatic forces and hydrogen bonds) and repulsive interactions (zeta potential). The aim of this study was to measure the force involved in RBC aggregation using double optical tweezers, in normal serum, in the presence of erythrocyte antibodies and associated to agglutination potentiator solutions (Dextran, low ionic strength solution [LISS] and enzymes). The optical tweezers consisted of a neodymium:yattrium aluminium garnet (Nd:YAG) laser beam focused through a microscope equipped with a minicam, which registered the trapped cell image in a computer where they could be analyzed using a software. For measuring RBC aggregation, a silica bead attached to RBCs was trapped and the force needed to slide one RBC over the other, as a function of the velocities, was determined. The median of the RBC aggregation force measured in normal serum (control) was 1 × 10(-3) (0.1-2.5) poise.cm. The samples analyzed with anti-D showed 2 × 10(-3) (1.0-4.0) poise.cm (p < 0.001). RBC diluted in potentiator solutions (Dextran 0.15%, Bromelain and LISS) in the absence of erythrocyte antibodies, did not present agglutination. High adherence was observed when RBCs were treated with papain. Results are in agreement with the imunohematological routine, in which non-specific results are not observed when using LISS, Dextran and Bromelain. Nevertheless, false positive results are frequently observed in manual and automated microplate analyzer using papain enzyme. The methodology proposed is simple and could provide specific information with the possibility of meansuration regarding RBC interaction.


Asunto(s)
Eritrocitos/citología , Procesamiento de Imagen Asistido por Computador/métodos , Pinzas Ópticas/normas , Células Cultivadas , Medios de Cultivo/química , Dextranos , Agregación Eritrocitaria/efectos de los fármacos , Eritrocitos/efectos de los fármacos , Humanos , Isoanticuerpos/química , Concentración Osmolar , Papaína/farmacología , Globulina Inmune rho(D) , Electricidad Estática
2.
J Biomed Opt ; 13(1): 014001, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18315359

RESUMEN

Red blood cell (RBC) aggregation in the blood stream is prevented by the zeta potential created by its negatively charged membrane. There are techniques, however, to decrease the zeta potential and allow cell agglutination, which are the basis of most of antigen-antibody tests used in immunohematology. We propose the use of optical tweezers to measure membrane viscosity, adhesion, zeta potential, and the double layer thickness of charges (DLT) formed around the cell in an electrolytic solution. For the membrane viscosity experiment, we trap a bead attached to RBCs and measure the force to slide one RBC over the other as a function of the velocity. Adhesion is quantified by displacing two RBCs apart until disagglutination. The DLT is measured using the force on the bead attached to a single RBC in response to an applied voltage. The zeta potential is obtained by measuring the terminal velocity after releasing the RBC from the trap at the last applied voltage. We believe that the methodology proposed here can provide information about agglutination, help to improve the tests usually performed in transfusion services, and be applied for zeta potential measurements in other samples.


Asunto(s)
Pruebas de Aglutinación/instrumentación , Pruebas de Aglutinación/métodos , Separación Celular/instrumentación , Membrana Eritrocítica/fisiología , Adhesiones Focales/fisiología , Pinzas Ópticas , Adhesividad , Separación Celular/métodos , Células Cultivadas , Elasticidad , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Potenciales de la Membrana , Estrés Mecánico
3.
Int J Nanomedicine ; 10: 4393-404, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26185442

RESUMEN

New methods of analysis involving semiconductor nanocrystals (quantum dots [QDs]) as fluorescent probes have been highlighted in life science. QDs present some advantages when compared to organic dyes, such as size-tunable emission spectra, broad absorption bands, and principally exceptional resistance to photobleaching. Methods applying QDs can be simple, not laborious, and can present high sensibility, allowing biomolecule identification and quantification with high specificity. In this context, the aim of this work was to apply dual-color CdTe QDs to quantify red blood cell (RBC) antigen expression on cell surface by flow cytometric analysis. QDs were conjugated to anti-A or anti-B monoclonal antibodies, as well as to the anti-H (Ulex europaeus I) lectin, to investigate RBCs of A1, B, A1B, O, A2, and Aweak donors. Bioconjugates were capable of distinguishing the different expressions of RBC antigens, both by labeling efficiency and by flow cytometry histogram profile. Furthermore, results showed that RBCs from Aweak donors present fewer amounts of A antigens and higher amounts of H, when compared to A1 RBCs. In the A group, the amount of A antigens decreased as A1 > A3 > AX = Ael, while H antigens were AX = Ael > A1. Bioconjugates presented stability and remained active for at least 6 months. In conclusion, this methodology with high sensibility and specificity can be applied to study a variety of RBC antigens, and, as a quantitative tool, can help in achieving a better comprehension of the antigen expression patterns on RBC membranes.


Asunto(s)
Antígenos de Grupos Sanguíneos/sangre , Compuestos de Cadmio/química , Citometría de Flujo/métodos , Puntos Cuánticos/química , Telurio/química , Anticuerpos Monoclonales , Eritrocitos/química , Humanos
4.
PLoS One ; 7(2): e31778, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22363729

RESUMEN

During storage, red blood cells (RBCs) for transfusion purposes suffer progressive deterioration. Sialylated glycoproteins of the RBC membrane are responsible for a negatively charged surface which creates a repulsive electrical zeta potential. These charges help prevent the interaction between RBCs and other cells, and especially among each RBCs. Reports in the literature have stated that RBCs sialylated glycoproteins can be sensitive to enzymes released by leukocyte degranulation. Thus, the aim of this study was, by using an optical tweezers as a biomedical tool, to measure the zeta potential in standard RBCs units and in leukocyte reduced RBC units (collected in CPD-SAGM) during storage. Optical tweezers is a sensitive tool that uses light for measuring cell biophysical properties which are important for clinical and research purposes. This is the first study to analyze RBCs membrane charges during storage. In addition, we herein also measured the elasticity of RBCs also collected in CPD-SAGM. In conclusion, the zeta potential decreased 42% and cells were 134% less deformable at the end of storage. The zeta potential from leukodepleted units had a similar profile when compared to units stored without leukoreduction, indicating that leukocyte lyses were not responsible for the zeta potential decay. Flow cytometry measurements of reactive oxygen species suggested that this decay is due to membrane oxidative damages. These results show that measurements of zeta potentials provide new insights about RBCs storage lesion for transfusion purposes.


Asunto(s)
Tecnología Biomédica/instrumentación , Conservación de la Sangre , Eritrocitos/fisiología , Pinzas Ópticas , Electricidad Estática , Movimiento Celular , Forma de la Célula , Elasticidad , Humanos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA