Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 31(7): 5106-5115, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33449184

RESUMEN

OBJECTIVE: Speckle-tracking echocardiography (STE) deformation parameters detect latent LV dysfunction in chronic aortic regurgitation (AR) and are associated with outcomes. The aim of the study was to evaluate cardiac magnetic resonance (CMR) feature tracking (FT) deformation parameters in asymptomatic patients with AR and implications in outcomes. METHODS: Fifty-five patients with AR and 54 controls were included. Conventional functional CMR parameters, aortic regurgitant volume, and fraction were assessed. CMR-FT analysis was performed with a dedicated software. Clinical data was obtained from hospital records. A combined endpoint included all-cause mortality, cardiovascular mortality, aortic valve surgery, or cardiovascular hospital admission due to heart failure. RESULTS: Left ventricular (LV) mechanics is impaired in patients with significant AR. Significant differences were noted in global longitudinal strain (GLS) between controls and AR patients (- 19.1 ± 2.9% vs - 16.5 ± 3.2%, p < 0.001) and among AR severity groups (- 18.3 ± 3.1% vs - 16.2 ± 1.6% vs - 15 ± 3.5%; p = 0.02 for AR grades I-II, III, and IV). In univariate and multivariate analyses, circumferential strain (GCS) and global radial strain (GRS) but not GLS were associated with and increased risk of the end point with a HR of 1.26 (p = 0.016, 1.04-1.52) per 1% worsening for GCS and 0.90 (p = 0.012, 0.83-0.98) per 1% worsening for GRS. CONCLUSIONS: CMR-FT myocardial deformation parameters are impaired in patients with AR not meeting surgical criteria. GLS decreases early in the course of the disease and is a marker of AR severity while GCS and GRS worsen later but predict a bad prognosis, mainly the need of aortic valve surgery. KEY POINTS: • CMR feature tracking LV mechanic parameters may be reduced in significant chronic AR with normal EF. • LV mechanics, mainly global longitudinal strain, worsens as AR severity increases. • LV mechanics, specially global radial and circumferential strain, is associated with a worse prognosis in AR patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Disfunción Ventricular Izquierda , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Pronóstico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
2.
Echocardiography ; 37(4): 586-591, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32212399

RESUMEN

INTRODUCTION: Limited data are available regarding the evaluation of right ventricular (RV) performance in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). OBJECTIVE: To evaluate the prevalence of RV dysfunction in patients with severe AS undergoing TAVI and long-term changes. METHODS: Consecutive patients with severe AS undergoing TAVI from January 2016 to July 2017 were included. RV anatomical and functional parameters were analyzed: RV diameters, fractional area change, tricuspid annular plane systolic excursion (TAPSE), S-wave tissue Doppler of the tricuspid annulus (RV-S'TDI), global longitudinal strain (RV-GLS), and free wall strain (RV-FWS). Preprocedure and 1-year echo were analyzed. RESULTS: Final population included 114 patients, mean age 83.63 ± 6.31 years, and 38.2% women. The prevalence of abnormal RV function was high, variable depending on the parameter that we analyzed, and it showed a significant reduction 1 year after TAVI implantation: 13.9% vs 6.8% (TAPSE < 17mm), P = .04; 26.3% vs 20% (fractional area change < 35%), P = .048; 41.2% vs 29.2% (RV-S'TDI < 9.5cm/s), P = .04; 48.7% vs 39.5% (RV-GLS > [20]), P = .049; and 48.7% vs 28.9% (RV-FWS > [20]), P = .03. Significant differences were noted between patients with low-flow (LF) vs normal-flow (NF) AS in RV dysfunction prevalence as well as in RV function recovery which is less evident in LF compared with NF patients. CONCLUSIONS: RV dysfunction is high among symptomatic AS patients undergoing TAVI, with variable prevalence depending on the echocardiographic parameter used.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Derecha , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Disfunción Ventricular Derecha/cirugía , Función Ventricular Derecha
3.
Cardiology ; 143(1): 52-61, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31307038

RESUMEN

PURPOSE: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has become a widespread technique for patients with severe AS considered inoperable or high risk for open surgery. This procedure could have a positive impact in LV mechanics. The aim of the study was to evaluate the effect of TAVR on LV function recovery, as assessed by myocardial deformation parameters, both immediately and in the long term. METHODS: One-hundred nineteen consecutive patients (81.2 ± 6.9 years, 50.4% female) from 10 centres in Europe with severe AS who successfully underwent TAVR with either a self-expanding CoreValve (Medtronic, Minneapolis, MN, USA) or a mechanically expanded Lotus valve (Boston Scientific, Natick, MA, USA) were enrolled in a prospective observational study. A complete echocardiographic examination was performed prior to device implantation, before discharge and 1 year after the procedure, including the assessment of LV strain using standard 2D images. RESULTS: Between baseline and discharge, only a modest but statistically significant improvement in GLS (global longitudinal strain) could be seen (GLS% -14.6 ± 5.0 at baseline; -15.7 ± 5.1 at discharge, p = 0.0116), although restricted to patients in the CoreValve group; 1 year after the procedure, a greater improvement in GLS was observed (GLS% -17.1 ± 4.9, p < 0.001), both in the CoreValve and the Lotus groups. CONCLUSIONS: Immediate and sustained improvement in GLS was appreciated after the TAVR procedure. Whether this finding continues to be noted in a more prolonged follow-up and its clinical implications need to be assessed in further studies.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Izquierda/terapia , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Estudios Prospectivos , Disfunción Ventricular Izquierda/etiología
4.
Cardiovasc Ultrasound ; 17(1): 28, 2019 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-31752893

RESUMEN

BACKGROUND: The search for reliable cardiac functional parameters is crucial in patients with mitral regurgitation (MR). In the Italian arm of the European Registry of MR, we compared the ability of global longitudinal strain (GLS) and left ventricular (LV) ejection fraction (LVEF) to detect cardiac damage in MR. METHODS: Five hundred four consecutive patients with MR underwent a complete echo-Doppler exam. A total of 431, 53 and 20 patients had degenerative, secondary and mixed MR, respectively. The main echocardiographic parameters, including LV and left atrial (LA) size measurements, pulmonary artery systolic pressure (PASP) and GLS were compared between patients with mild MR (n = 392) vs. moderate to severe MR (n = 112). RESULTS: LVEF and GLS were related one another in the pooled population, and separately in patients with mild and moderate/severe MR (all p < 0.0001). However, a certain number of patients were above the upper or below the lower limits of the 95% confidence interval (CI) of the normal relation in the pooled population and in patients with mild MR. Only 2 patients were below the 95% CI in moderate to severe MR. After adjusting for confounders by separate multivariate models, LVEF and GLS were independently associated with LV and left atrial size in the pooled population and in mild and moderate/severe MR. GLS, but not LVEF, was also independently associated with PASP in patients with mild and moderate to severe MR. CONCLUSIONS: Both LVEF and GLS are independently associated with LV and LA size, but only GLS is related to pulmonary arterial pressure. GLS is a powerful hallmark of cardiac damage in MR.


Asunto(s)
Ecocardiografía Doppler/métodos , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico , Válvula Mitral/diagnóstico por imagen , Contracción Miocárdica/fisiología , Volumen Sistólico/fisiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Ventrículos Cardíacos/fisiopatología , Humanos , Italia , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/fisiopatología , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Función Ventricular Izquierda/fisiología , Adulto Joven
5.
Am Heart J ; 185: 123-129, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28267465

RESUMEN

The optimal approach to assess right ventricular (RV) function in patients with acute symptomatic pulmonary embolism (PE) lacks clarity. METHODS: This study aimed to evaluate the optimal approach to assess RV function in normotensive patients with acute symptomatic PE. Outcomes assessed through 30-days after the diagnosis of PE included all-cause mortality and complicated course. RESULTS: Eight hundred forty-eight patients were enrolled. Multidetector computed tomography (MDCT) and transthoracic echocardiography agreed on the presence or absence of RV overload in 449 (53%) patients. The combination of the simplified Pulmonary Embolism Severity Index (sPESI) and MDCT showed a negative predictive value for 30-day all-cause mortality of 100%. Of the 43% that had an sPESI of >0 points and MDCT RV enlargement, 41 (11.3%) experienced a complicated course that included 24 (6.6%) deaths. One hundred twenty-nine patients (15%) had an sPESI of >0 points, MDCT, and echocardiographic RV overload. Of these, 21 (16.3%) experienced a complicated course within the first 30days, and 10 (7.7%) of them died. CONCLUSIONS: Incorporation of echocardiographic RV overload to the sPESI and MDCT did not improve identification of low-risk PE patients, whereas it improved identification of those at intermediate-high risk for short-term complications.


Asunto(s)
Mortalidad , Embolia Pulmonar/fisiopatología , Disfunción Ventricular Derecha/diagnóstico por imagen , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Causas de Muerte , Comorbilidad , Ecocardiografía , Femenino , Insuficiencia Cardíaca/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Pronóstico , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Embolia Pulmonar/complicaciones , Embolia Pulmonar/epidemiología , Medición de Riesgo , Índice de Severidad de la Enfermedad , Disfunción Ventricular Derecha/complicaciones , Disfunción Ventricular Derecha/epidemiología , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha
6.
Echocardiography ; 34(8): 1122-1129, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28589566

RESUMEN

AIMS: To evaluate how often patients with moderate-to-severe or severe mitral regurgitation (MR) meet the anatomical criteria for MitraClip implant and to examine the role of transthoracic echocardiography (TTE) for this task. METHODS AND RESULTS: From February to June 2015, all patients undergoing a TTE in nine Spanish hospitals were prospectively included. Patients with moderate-to-severe and severe mitral regurgitation were selected for analysis. Anatomical eligibility criteria for MitraClip were defined according to the EVEREST trial. A total of 39 855 consecutive TTE were reviewed, and 1403 patients with moderate-to-severe and severe MR were finally included. Primary MR was found in 779 patients (56%). Only in 74 patients (16%), all anatomical criteria for MitraClip could be assessed by TTE. Of these, 56% of patients had optimal valve morphology. Secondary MR was described in 361 patients (26%), and at least 249 of these (69%) had a high surgical risk. All five criteria for MitraClip were adequately assessed by TTE in 299 patients (83%). Of them, 118 patients (39%) had optimal valve morphology. CONCLUSIONS: A considerable proportion of patients have optimal mitral valve morphology for MitraClip. Moreover, TTE was particularly useful in determining whether or not the anatomical criteria for MitraClip implant were met in the majority of patients with secondary MR but in only a minority of those with primary MR.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico , Válvula Mitral/diagnóstico por imagen , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Prevalencia , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , España/epidemiología
8.
J Heart Valve Dis ; 25(6): 724-729, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-28290172

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Although mitral regurgitation (MR) is a well-recognized prognosis factor, its true prevalence is probably underestimated and its etiology and mechanisms have not been sufficiently explored. The study aim was to evaluate the burden of MR, focusing attention on its frequency, severity, etiology, mechanism, and other associated conditions. METHODS: Between February and June 2015, a total of 39,855 consecutive echocardiographic studies was performed at nine tertiary hospitals, and were prospectively included in the study. MR severity was graded into four groups, ranging from none or trace to severe MR, in accordance with the recommendations of the European Association of Cardiovascular Imaging. Patients with moderate to severe MR were selected for the analysis. RESULTS: MR was detected in 22.6% of cases. MR severity was mild in 82.5% of patients (n = 7,376), moderate in 11.7% (n = 1,048), and severe in 5.8% (n = 521). Concomitant valvular heart disease was present in 3,544 patients (39.7%), with tricuspid regurgitation the most frequently encountered (21.6%). Among moderate and severe MR, primary MR was more frequent than secondary MR (58.8% versus 23.5%), with degenerative valve disease being the most common cause of primary MR (49.2%). A third group composed of mixed forms of MR was described in 17.8% of cases. CONCLUSIONS: MR is a common finding on echocardiography, and is frequently associated with other valvular heart disease. Most MRs are of degenerative origin. The primary and secondary forms of MR differ significantly in their clinical presentation with regard to gender, age, and ventricular function. There appears to be a gap for a 'mixed' group, though further studies are needed to confirm this suggestion.


Asunto(s)
Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Anciano , Ecocardiografía , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Humanos , Masculino , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/epidemiología , Prevalencia , Estudios Prospectivos , Índice de Severidad de la Enfermedad
9.
Cardiovasc Ultrasound ; 14(1): 17, 2016 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-27184953

RESUMEN

BACKGROUND: 3D transesophageal echocardiography (TEE) is superior to 2D TEE in quantitative anatomic evaluation of the mitral valve (MV) but it shows limitations regarding automatic quantification. Here, we tested the inter-/intra-observer reproducibility of a novel full-automated software in the evaluation of MV anatomy compared to manual 3D assessment. METHODS: Thirty-six out of 61 screened patients referred to our Cardiac Imaging Unit for TEE were retrospectively included. 3D TEE analysis was performed both manually and with the automated software by two independent operators. Mitral annular area, intercommissural distance, anterior leaflet length and posterior leaflet length were assessed. RESULTS: A significant correlation between both methods was found for all variables: intercommissural diameter (r = 0.84, p < 0.01), mitral annular area (r = 0.94, p > 0, 01), anterior leaflet length (r = 0.83, p < 0.01) and posterior leaflet length (r = 0.67, p < 0.01). Interobserver variability assessed by the intraclass correlation coefficient was superior for the automatic software: intercommisural distance 0.997 vs. 0.76; mitral annular area 0.957 vs. 0.858; anterior leaflet length 0.963 vs. 0.734 and posterior leaflet length 0.936 vs. 0.838. Intraobserver variability was good for both methods with a better level of agreement with the automatic software. CONCLUSIONS: The novel 3D automated software is reproducible in MV anatomy assessment. The incorporation of this new tool in clinical MV assessment may improve patient selection and outcomes for MV interventions as well as patient diagnosis and prognosis stratification. Yet, high-quality 3D images are indispensable.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Enfermedades de las Válvulas Cardíacas/diagnóstico , Válvula Mitral/diagnóstico por imagen , Programas Informáticos , Anciano , Femenino , Humanos , Masculino , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
10.
Echocardiography ; 32(1): 96-105, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24661050

RESUMEN

BACKGROUND: Swirling flow, organized in vortices, contributes to adequate left ventricular function. In this study, we apply a novel echocardiographic flow-mapping technique, vector flow mapping (VFM), to evaluate the main characteristics of left ventricular vortices and its relation to filling parameters. METHODS: Forty-eight subjects underwent conventional transthoracic echocardiographic examination with additional intracardiac flow assessment with VFM using a Aloka Alpha-10 system and experimental VFM analysis software. To analyze vortex behavior, its rotation direction, duration, location inside the left ventricle, size, and intensity were assessed in apical long-axis view. Its relation to conventional left ventricular filling parameters was then analyzed. RESULTS: Two vortex components were consistently identified following each transmitral filling wave. The anterior component of these visualized vortices was analyzed, due to its higher significance in the cardiac cycle, following early filling (V1) and atrial contraction (V2). Differences were observed in several aspects of vortex behavior between V1 and V2, particularly in patients with normal left ventricular filling parameters. These differences may be related to varying roles of vortices in different periods of the cardiac cycle. CONCLUSIONS: Vector flow mapping allowed visualization and measurement of several parameters defining vortex behavior inside the cardiac cycle. The differences observed in these parameters between vortices in different phases of the cardiac cycle may be related to their role in optimizing cardiac function.


Asunto(s)
Velocidad del Flujo Sanguíneo , Ecocardiografía/métodos , Ventrículos Cardíacos/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Reología/métodos , Sensibilidad y Especificidad
11.
Cardiovasc Ultrasound ; 12: 29, 2014 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-25092465

RESUMEN

OBJECTIVES: To evaluate the interobserver reliability of echocardiographic findings of right ventricle (RV) dysfunction for prognosticating normotensive patients with pulmonary embolism (PE). METHODS: A central panel of cardiologists evaluated echocardiographic studies of 75 patients included in the PROTECT study for the following signs: RV diameter, RV/left ventricular (LV) diameter ratio, hypokinesis of the RV free wall, and tricuspid plane systolic excursion (TAPSE). Investigators used intraclass correlation to assess agreement between the measurements of the central panel and each of the local cardiologists. Investigators used the single weighted kappa statistic to test for agreement between readers of interpretation of RV enlargement and RV hypokinesis. RESULTS: The two observers had fair agreement (k = 0.45) for RV enlargement assessed by the RV diameter, and good agreement (k = 0.65) for RV enlargement assessed by the RV/LV diameter ratio. The interobserver reliability of the assessment whether hypokinesis of the RV free wall is present was good (к = 0.70), and whether RV dysfunction (assessed by TAPSE measurement) is present was very good (k = 0.86). The intraclass correlation for the RV/LV diameter ratio was fair (0.55; 95% confidence interval [CI], 0.37-0.69), for the RV diameter was good (0.70; 95% CI, 0.56-0.80), and for the TAPSE measurement was very good (0.85; 95% CI, 0.77-0.90). On Bland-Altman analysis, the mean differences for RV diameter, RV/LV diameter ratio and TAPSE measurement were 2.33 (±5.38), 0.06 (±0.23) and 0.08 (±2.20), respectively. CONCLUSION: TAPSE measurement is the least user dependent and most reproducible echocardiographic finding of RV dysfunction in normotensive patients with PE.


Asunto(s)
Ecocardiografía/métodos , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Volumen Sistólico , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Anciano , Estudios de Cohortes , Femenino , Humanos , Hipertensión/complicaciones , Hipertensión/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Pronóstico , Estudios Prospectivos , Radiografía , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad , España
12.
Echocardiography ; 31(1): E10-2, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24102705

RESUMEN

We describe the use of vector flow mapping (VFM), a novel echocardiographic technique allowing intracardiac flow visualization, to quantify flow intensity inside a left ventricular aneurysm in a 68-year-old man. VFM successfully identified areas of stagnant flow corresponding to the wall region where a thrombus had been formed.


Asunto(s)
Ecocardiografía/métodos , Aneurisma Cardíaco/complicaciones , Aneurisma Cardíaco/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Trombosis/etiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Anciano , Estudios de Factibilidad , Humanos , Masculino , Reología/métodos
13.
J Invasive Cardiol ; 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662952

RESUMEN

The authors present a case of percutaneous closure of an incomplete surgical left atrial appendage (LAA) ligation with a new device LAmbre (Lifetech ScientificCo Ltd).

14.
Eur Heart J Cardiovasc Imaging ; 25(4): 520-529, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37956101

RESUMEN

AIMS: Right ventricular (RV) performance determines clinical management in severe tricuspid regurgitation (TR). Right atrial (RA) function complements RV assessment in TR. This study aimed to design a novel index by speckle-tracking echocardiography (STREI index) integrating RA and RV strain information and to evaluate the clinical utility of combining RV and RA strain for prediction of cardiovascular (CV) outcomes. METHODS AND RESULTS: Consecutive patients with at least (≥) severe TR evaluated in the Heart Valve Clinic (n = 300) were prospectively included. An additional independent TR cohort was included for external validation (n = 50). STREI index was developed with the formula: [2 ∗ RV-free wall longitudinal strain (RV-FWLS)] + reservoir RA strain (RASr). The composite endpoint included hospital admission due to heart failure and all-cause mortality. A total of 176 patients with ≥severe TR were finally included. STREI index identified a higher percentage of patients with RV dysfunction compared with conventional parameters. After a median follow-up of 2.2 years (interquartile range: 12-41 months), a total of 38% reached the composite endpoint. STREI values were predictors of outcomes independently of TR severity and RV dimensions. The combination of prognostic cut-off values of RASr (<10%) and RV-FWLS (>-20%) (STREI stratification) stratified four different groups of risk independently of TR severity, RV dimensions, and clinical status (adj HR per stratum 1.89 (1.4-2.34), P < 0.001). Pre-defined cut-off values achieved similar prognostic performance in the validation cohort (n = 50). CONCLUSION: STREI index is a novel parameter of RV performance that independently predicts CV events. The combination of RA and RV strain stratifies better patients' risk, reflecting a broader effect of TR on right heart chambers.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Ecocardiografía/métodos , Pronóstico , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha
15.
ESC Heart Fail ; 11(4): 2272-2286, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38638083

RESUMEN

AIM: Severe functional tricuspid regurgitation (FTR) is associated with high risk of cardiovascular events, particularly heart failure (HF) and mortality. MicroRNAs (miRNAs) have been recently identified as novel biomarkers in different cardiovascular conditions, but no studies have focused on FTR. We sought to (1) to identify and validate circulating miRNAs as regulators of FTR and (2) to test association of miRNA with heart failure and mortality in FTR. METHODS AND RESULTS: Consecutive patients with isolated severe FTR (n = 100) evaluated in the outpatient Heart Valve Clinic and age- and gender-matched subjects with no TR (controls, n = 50) were prospectively recruited. The experimental design included (1) a screening phase to identify candidate miRNA differentially expressed in FTR (n = 8) compared with controls (n = 8) through miRNA array profiling of 192 miRNAs using quantitative reverse transcription PCR arrays [qRT-PCR]) and (2) a validation phase in which candidate miRNAs identified in the initial screening were selected for further validation by qRT-PCR in a prospectively recruited cohort of FTR (n = 92) and controls (n = 42). Bioinformatics analysis was used to predict their potential target genes and functional pathways elicited. A combined endpoint of hospital admission due to heart failure (HF) and all-cause mortality was defined. Initial screening identified 16 differentially expressed miRNAs in FTR compared with controls, subsequently confirmed in the validation phase (n = 16 were excluded due to significant haemolysis). miR-186-5p, miR-30e-5p, and miR-152-3p identified FTR with high predictive value [AUC of 0.93 (0.88-0.97), 0.83 (0.75-0.91) and 0.84 (0.76-0.92), respectively]. During a median follow-up of 20.4 months (IQR 8-35 months), 32% of FTR patients reached the combined endpoint. Patients with low relative expression of miR-15a-5p, miR-92a-3p, miR101-3p, and miR-363-3p, miR-324-3p, and miR-22-3p showed significantly higher rates of events (log-rank test for all P < 0.01). Both miR-15a-5p [hazard ratio: 0.21 (0.06-0.649, P = 0.007) and miR-92a-3p (0.27 (0.09-0.76), P = 0.01] were associated with outcomes after adjusting for age, gender, and New York Heart Association functional class. CONCLUSIONS: Circulating miRNAs are novel diagnostic and prognostic biomarkers in severe FTR. The quantification of miR-186-5p, miR-30e-5p, and miR-152-3p held strong diagnostic value, and the quantification of miR-15a-5p and miR-92a-3p are independently associated with outcomes. The recognition of specific miRNAs offers a novel perspective for TR evaluation.


Asunto(s)
Biomarcadores , MicroARN Circulante , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Femenino , Insuficiencia Cardíaca/genética , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/diagnóstico , Proyectos Piloto , Insuficiencia de la Válvula Tricúspide/genética , Insuficiencia de la Válvula Tricúspide/epidemiología , Estudios Prospectivos , MicroARN Circulante/sangre , MicroARN Circulante/genética , Biomarcadores/sangre , Persona de Mediana Edad , Anciano , Pronóstico , MicroARNs/sangre , MicroARNs/genética , Estudios de Seguimiento
16.
Echocardiography ; 30(5): E125-7, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23489108

RESUMEN

A young patient underwent a screening electrocardiogram (EKG) that suggested apical hypertrophic cardiomyopathy. Serial investigation with echocardiography showed a well-defined hyperechogenic mass involving the interventricular septal. To better define the lesion extension three-dimensional (3D) echocardiography was done and it demonstrated a mass invading the septal myocardium, involving the major part of the muscular portion. The findings were highly suggestive of a cardiac fibroma. A cardiac magetic resonance image (MRI) was also compatible with this diagnosis. In our case, 3D echo showed a high accuracy, proving to be a useful tool to determine the anatomy of the lesion, complementary to MRI, guiding best management strategy.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico , Ecocardiografía Tridimensional/métodos , Fibroma/diagnóstico , Neoplasias Cardíacas/diagnóstico , Ventrículos Cardíacos/patología , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Diagnóstico Diferencial , Electrocardiografía/métodos , Fibroma/cirugía , Estudios de Seguimiento , Neoplasias Cardíacas/cirugía , Ventrículos Cardíacos/cirugía , Humanos , Imagen por Resonancia Cinemagnética/métodos , Masculino , Rol , Resultado del Tratamiento , Adulto Joven
17.
JACC Case Rep ; 12: 101774, 2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37091052

RESUMEN

A 78-year-old woman with severe symptomatic secondary atrial tricuspid regurgitation and a long segment of right coronary artery proximity in the posterior tricuspid annulus was treated with transcatheter annuloplasty. Six consecutive anchors were implanted at the level of the atrial wall, crossing the right coronary artery, achieving residual mild regurgitation. (Level of Difficulty: Advanced.).

18.
J Am Soc Echocardiogr ; 36(6): 615-623, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36828258

RESUMEN

BACKGROUND: Right ventricular (RV) systolic function is an established marker of outcomes in patients with severe tricuspid regurgitation (TR). Timely detection of RV dysfunction using conventional two-dimensional echocardiography is challenging. RV strain has emerged as an accurate and sensitive tool for the evaluation of RV function, with the capability to detect subclinical RV dysfunction. The aim of this study was to evaluate the prognostic value of RV strain parameters in early stages of severe TR. METHODS: Consecutive patients with at least severe TR (severe, massive, or torrential) and the absence of a formal indication for tricuspid valve intervention in secondary TR evaluated in the Heart Valve Clinic were prospectively included. RV systolic function was measured using conventional echocardiographic indices (RV fractional area change, tricuspid annular plane systolic excursion, and Doppler tissue imaging S wave [S']) and speckle-tracking echocardiography-derived automatic peak global longitudinal strain and free wall longitudinal strain (FWLS) using an automated two-dimensional strain analytic software. A combined end point of hospital admission due to heart failure or all-cause mortality was defined. RESULTS: A total of 266 patients were enrolled in the study, and 151 were ultimately included. Strain parameters detected a higher percentage of abnormal RV values compared with conventional indices. During a median follow-up period of 26 months (interquartile range, 13-42 months), 35% of the patients reached the combined end point. Cumulative event-free survival was significantly worse in patients with impaired RV global longitudinal strain and RV FWLS. Conventional indices of RV systolic function were not associated with outcomes (P > .05 for all). On multivariate analysis, RV FWLS was independently associated with mortality and heart failure (adjusted hazard ratio for abnormal RV FWLS, 5.90; 95% CI, 3.17-10.99; P < .001). CONCLUSION: In early stages of severe TR, RV FWLS is more frequently impaired compared with conventional indices of RV function. Among all parameters, RV FWLS is the strongest predictor of mortality and heart failure, independent of additional prognostic markers.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Pronóstico , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Ecocardiografía/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología
19.
Rev Esp Cardiol (Engl Ed) ; 76(11): 845-851, 2023 Nov.
Artículo en Inglés, Español | MEDLINE | ID: mdl-36898521

RESUMEN

INTRODUCTION AND OBJECTIVES: Significant tricuspid regurgitation (TR) is associated with increased morbidity and mortality. Clinical evaluation of TR patients is challenging. Our aim was to establish a new clinical classification specific for patients with TR, the 4A classification, and evaluate its prognostic performance. METHODS: We included patients with isolated TR that was at least severe and without previous episodes of heart failure (HF) who were assessed in the heart valve clinic. We registered signs and symptoms of asthenia, ankle swelling, abdominal pain or distention and/or anorexia and followed up the patients every 6 months. The 4A classification ranged from A0 (no A) to A3 (3 or 4 As present). We defined a combined endpoint consisting of hospital admission due to right HF or cardiovascular mortality. RESULTS: We included 135 patients with significant TR between 2016 and 2021 (69% females, mean age 78±7 years). During a median follow-up of 26 [IQR, 10-41] months, 39% (n=53) patients had the combined endpoint: 34% (n=46) were admitted for HF and 5% (n=7) died. At baseline, 94% of the patients were in NYHA I or II, while 24% were in classes A2 or A3. The presence of A2 or A3 conferred a high incidence of events. The change in 4A class remained an independent marker of HF and cardiovascular mortality (adjusted HR per unit of change of 4A class, 1.95 [1.37-2.77]; P<.001). CONCLUSIONS: This study reports a novel clinical classification specifically for patients with TR that is based on signs and symptoms of right HF and has prognostic value for events.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Masculino , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/epidemiología , Pronóstico , Morbilidad , Incidencia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/complicaciones , Resultado del Tratamiento
20.
Eur Heart J Cardiovasc Imaging ; 24(8): 1092-1101, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37073554

RESUMEN

AIMS: The optimal management of severe tricuspid regurgitation (TR) remains controversial. While right ventricular systolic function is an established prognostic marker of outcomes, the potential role of right atrial (RA) function is unknown. This study aimed to describe RA function by 2D speckle-tracking echocardiography (STE) in at least severe TR and to evaluate its potential association with cardiovascular outcomes. METHODS AND RESULTS: Consecutive patients with at least (≥) severe TR (severe, massive, or torrential TR) evaluated in the Heart Valve Clinic following a comprehensive clinical protocol were included. Consecutive control subjects and patients with permanent isolated atrial fibrillation (AF) were included for comparison (control and AF group, respectively). RA function was measured with 2D-STE and two components of RA function were calculated: reservoir (RASr) and contractile (RASct) strain (AutoStrain, Philips Medical Systems the EPIQ system). A combined endpoint of hospital admission due to heart failure (HF) or all-cause mortality was defined. Patients with ≥ severe TR (n = 140) showed lower RASr compared with controls (n = 20) and with the AF group (n = 20) (P < 0.001). Atrial TR showed lower RASr compared with other aetiologies of TR (P < 0.001). After a median follow-up of 2.2 years (IQR: 12-41 months), RASr remained an independent predictor of mortality and HF. A cut-off value of RASr of <9.4% held the best accuracy to predict outcomes. CONCLUSION: RA function by 2D-STE independently predicts mortality and HF hospitalizations in patients with ≥ severe TR.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Pronóstico , Función del Atrio Derecho , Ecocardiografía , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA