Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
2.
Catheter Cardiovasc Interv ; 102(6): 1132-1139, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668083

RESUMEN

BACKGROUND: Limited data are available on transcatheter heart valves (THVs) durability in bicuspid aortic valve (BAV) stenosis. AIMS: To evaluate evaluating 4-year clinical and echocardiographic outcomes of patients with BAV undergoing transcatheter aortic valve implantation (TAVI). METHODS: The bicuSpid TAvi duraBILITY (STABILITY) registry is an Italian multicentre registry including all consecutive patients with BAV and severe aortic stenosis (AS), treated by means of TAVI between January 2011 and December 2017. Outcomes of interest were all-cause death at 4-year, over time changes in echocardiographic measurements, and THV durability according to the valve aortic research consortium (VARC)-3 update definitions. RESULTS: Study population included 109 patients (50% females; mean age 78 ± 7.5 years) with a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.1 ± 4.3%. Median follow-up (FU) duration was 4.1 years [interquartile range: 2.8-5.1]. The overall cumulative incidence of all-cause death by Kaplan-Meier estimates at 4 years was 32%. Compared to baseline, a significant decrease in transprosthetic mean gradient was obtained after TAVI (54 ± 16 vs. 10 ± 5 mmHg; p < 0.001), whereas a significant increase was observed at 4-year (13 ± 6.4 mmHg, p = 0.03). Cumulative incidence of hemodynamic valve dysfunction (HVD) was 4%. Six patients met HVD criteria: three moderate and three severe HVD. All three cases of severe HVD were clinically relevant (bioprosthetic valve failure [BVF]) with two patients receiving a reintervention (TAVI in TAVI), and one patient experiencing a valve-related death due to endocarditis. CONCLUSIONS: The STABILITY registry suggests that in patients with severe AS and BAV undergoing TAVI, postprocedural clinical benefits might last, over time, up to 4-year FU. The low rates of severe HVD and BVF may support the hypothesis of good THV durability also in BAV recipient.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Estenosis de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Constricción Patológica , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros
3.
Circulation ; 143(2): 104-116, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-32975133

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Sistema de Registros , Reoperación/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación/tendencias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
4.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
5.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-33733675

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
Eur Heart J ; 41(20): 1876-1886, 2020 05 21.
Artículo en Inglés | MEDLINE | ID: mdl-31904800

RESUMEN

AIMS: In the last decade, transcatheter aortic valve (TAV) replacement determined a paradigm shift in the treatment of patients with severe symptomatic aortic stenosis. Data on long-term TAV performance are still limited. We sought to evaluate the clinical and haemodynamic outcomes of the CoreValve self-expandable valve up to 8-year follow-up (FU). METHODS AND RESULTS: Nine hundred and ninety inoperable or high-risk patients were treated with the CoreValve TAV in eight Italian Centres from June 2007 to December 2011. The median FU was 4.4 years (interquartile range 1.4-6.7 years). Longest FU reached 11 years. A total of 728 died within 8-year FU (78.3% mortality from Kaplan-Meier curve analysis). A significant functional improvement was observed in the majority of patients and maintained over time, with 79.3% of surviving patients still classified New York Heart Association class ≤ II at 8 years. Echocardiographic data showed that the mean transprosthetic aortic gradient remained substantially unchanged (9 ± 4 mmHg at discharge, 9 ± 5 mmHg at 8 years, P = 0.495). The rate of Grade 0/1 paravalvular leak was consistent during FU with no significant change from post-procedure to FU ≥5 years in paired analysis (P = 0.164). Structural valve deterioration (SVD) and late bioprosthetic valve failure (BVF) were defined according to a modification of the 2017 EAPCI/ESC/EACTS criteria. In cumulative incidence functions at 8 years, moderate and severe SVD were 3.0% [95% confidence interval (CI) 2.1-4.3%] and 1.6% (95% CI 0.6-3.9%), respectively, while late BVF was 2.5% (95% CI 1.2-5%). CONCLUSION: While TAVs are questioned about long-term performance and durability, the results of the present research provide reassuring 8-year evidence on the CoreValve first-generation self-expandable bioprosthesis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
7.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32592401

RESUMEN

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 96(7): 1500-1508, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32644300

RESUMEN

AIMS: We aim at exploring whether severe chronic kidney disease (CKD) may modify the impact of acute kidney injury (AKI) post-transcatheter aortic valve implantation (TAVI) on early, mid, and long-term mortality. METHODS AND RESULTS: The analysis included 2,733 TAVI patients from the Italian Clinical Service Project. The population was stratified in four groups according to the presence of baseline severe CKD and postprocedural AKI. All-cause mortality was the primary end point. Postprocedural AKI is associated with an increased risk of early and mid-term mortality after TAVI regardless of baseline severe CKD. Preprocedural severe CKD is associated with an increased risk of long-term mortality after TAVI regardless of postprocedural AKI. No interaction between preprocedural severe CKD and postprocedural AKI was observed in predicting mortality at both 30-day (CKD: hazard ratio [HR] = 2.65, 95% confidence interval [CI] = 1.15-6.12; no-CKD: HR = 3.83, 95% CI = 2.23-6.58; Pint = .129) and 1-year (CKD: HR = 2.29, 95% CI = 1.37-3.82; no-CKD: HR = 2.47, 95% CI = 1.75-3.49; Pint = .386). Preprocedural severe CKD is an independent predictor of postprocedural AKI (HR = 2.17, 95% CI = 1.56-3.03; p < .001) as well as general anesthesia and access alternative to femoral. Among no-AKI patients, those with severe CKD at admission underwent kidney function recovery after TAVI (serum creatinine at baseline 2.24 ± 1.57 mg/dL and at 48-hr 1.80 ± 1.17 mg/dL; p = .003). CONCLUSIONS: Preprocedural severe CKD did not modify the impact of postprocedural AKI in predicting early and mid-term mortality after TAVI. Closely monitoring of serum creatinine and strategies to prevent AKI post-TAVI are needed also in patients without severe CKD at admission.


Asunto(s)
Lesión Renal Aguda/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Tasa de Filtración Glomerular , Riñón/fisiopatología , Insuficiencia Renal Crónica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Biomarcadores/sangre , Causas de Muerte , Creatinina/sangre , Femenino , Humanos , Italia/epidemiología , Masculino , Estudios Prospectivos , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/fisiopatología , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 96(5): 1128-1135, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32627924

RESUMEN

OBJECTIVES: Aim of this study is to evaluate safety, feasibility, and mid-term outcome of transcatheter aortic valve implantation (TAVI) in cardiogenic shock (CS). BACKGROUND: Balloon aortic valvuloplasty in patients with severe aortic valve stenosis (SAS) complicated by CS is indicated but associated with a grim prognosis. TAVI might be a more reasonable treatment option in this setting but data are scant. METHODS: From March 2008 to February 2019, 51 patients with severe aortic valvulopathy (native SAS or degenerated aortic bioprosthesis) and CS treated by TAVI in 11 European centers were included in this multicenter registry. Demographic, clinical, and procedural data were collected, as well as clinical and echocardiographic follow-up. RESULTS: The mean age of our study population was 75.8 ± 13, 49% were women, and mean Society of Thoracic Surgeons (STS) score was 19 ± 15%. Device success was achieved in 94.1%, with a 5% incidence of moderate/severe paravalvular leak. The 30-day events were mortality 11.8%, stroke 2.0%, vascular complications 5.9%, and acute kidney injury 34%. Valve Academic Research Consortium-2 early safety endpoint was reached in 35.3% of cases. At 1-year of follow-up, the mortality rate was 25.7% and the readmission for congestive heart failure was 8.6%. CONCLUSIONS: TAVI seems to be a therapeutic option for patients with CS and SAS or degenerated aortic bioprosthesis in terms of both safety and efficacy at early and long-term follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Choque Cardiogénico/etiología , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Europa (Continente) , Estudios de Factibilidad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/mortalidad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
10.
Am Heart J ; 217: 32-41, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31473325

RESUMEN

Limited evidence is available on 5-year clinical outcomes after percutaneous edge-to-edge mitral valve repair. METHODS: The Getting Reduction of mitrAl inSufficiency by Percutaneous clip implantation in ITaly (GRASP-IT) is a multicenter registry including 304 consecutive patients undergoing Mitraclip between October 2008 and October 2013 at 4 Italian centers. Primary end point (all-cause mortality) and secondary end point (all-cause mortality or heart failure [HF] hospitalization) were evaluated up to 5 years and between 1 and 5 years. RESULTS: Cumulative incidence of the primary and secondary end points at 1, 2, 3, 4, and 5 years were 15.1%, 26.4%, 35.5%, 42.1%, and 47.3% and 29.1%, 41.7%, 49.8%, 56%, and 62.3%, respectively. Landmark analysis between 1 and 5 years showed an incidence of primary and secondary end point of 37.9% and 46.8%, respectively. Five-year event rates were significantly higher in patients with functional ischemic mitral regurgitation (MR) compared to other etiologies. MR recurrence and left ventricular ejection fraction <30% were associated with an increased risk of both primary and secondary end points. EuroSCORE II >5% was associated with an increased risk of 5-year mortality. Ischemic etiology of MR, baseline serum creatinine >1.5 mg/dL, chronic obstructive pulmonary disease, and previous HF hospitalizations were independent predictors of 5-year secondary end point. CONCLUSIONS: At 5-year follow-up after Mitraclip, nearly half of patients died and almost two thirds died or were admitted for HF. MR recurrence, ischemic etiology, high comorbidity burden (ie, EuroSCORE II >5%, chronic obstructive pulmonary disease), and advanced cardiomyopathy (ie, left ventricular ejection fraction <30%, prior HF admission, creatinine >1.5 mg/dL) significantly increase the relative risk of 5-year clinical events.


Asunto(s)
Insuficiencia Cardíaca/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Complicaciones Posoperatorias/epidemiología , Anciano , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Causas de Muerte , Femenino , Insuficiencia Cardíaca/etiología , Hospitalización/estadística & datos numéricos , Humanos , Incidencia , Italia , Masculino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/mortalidad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Enfermedad Pulmonar Obstructiva Crónica/epidemiología , Recurrencia , Sistema de Registros/estadística & datos numéricos , Estudios Retrospectivos , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
11.
Eur Heart J ; 39(8): 687-695, 2018 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-29020413

RESUMEN

Aims: There are limited data on coronary obstruction following transcatheter valve-in-valve (ViV) implantation inside failed aortic bioprostheses. The objectives of this study were to determine the incidence, predictors, and clinical outcomes of coronary obstruction in transcatheter ViV procedures. Methods and results: A total of 1612 aortic procedures from the Valve-in-Valve International Data (VIVID) Registry were evaluated. Data were subject to centralized blinded corelab computed tomography (CT) analysis in a subset of patients. The virtual transcatheter valve to coronary ostium distance (VTC) was determined. A total of 37 patients (2.3%) had clinically evident coronary obstruction. Baseline clinical characteristics in the coronary obstruction patients were similar to controls. Coronary obstruction was more common in stented bioprostheses with externally mounted leaflets or stentless bioprostheses than in stented with internally mounted leaflets bioprostheses (6.1% vs. 3.7% vs. 0.8%, respectively; P < 0.001). CT measurements were obtained in 20 (54%) and 90 (5.4%) of patients with and without coronary obstruction, respectively. VTC distance was shorter in coronary obstruction patients in relation to controls (3.24 ± 2.22 vs. 6.30 ± 2.34, respectively; P < 0.001). Using multivariable analysis, the use of a stentless or stented bioprosthesis with externally mounted leaflets [odds ratio (OR): 7.67; 95% confidence interval (CI): 3.14-18.7; P < 0.001] associated with coronary obstruction for the global population. In a second model with CT data, a shorter VTC distance predicted this complication (OR: 0.22 per 1 mm increase; 95% CI: 0.09-0.51; P < 0.001), with an optimal cut-off level of 4 mm (area under the curve: 0.943; P < 0.001). Coronary obstruction was associated with a high 30-day mortality (52.9% vs. 3.9% in the controls, respectively; P < 0.001). Conclusion: Coronary obstruction following aortic ViV procedures is a life-threatening complication that occurred more frequently in patients with prior stentless or stented bioprostheses with externally mounted leaflets and in those with a short VTC.


Asunto(s)
Oclusión Coronaria/epidemiología , Tomografía Computarizada Multidetector/métodos , Falla de Prótesis/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Femenino , Prótesis Valvulares Cardíacas , Humanos , Incidencia , Masculino , Análisis Multivariante , Sistema de Registros , Factores de Riesgo
12.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-33044863
13.
JAMA ; 316(10): 1083-92, 2016 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-27623462

RESUMEN

IMPORTANCE: Limited data exist on clinical characteristics and outcomes of patients who had infective endocarditis after undergoing transcatheter aortic valve replacement (TAVR). OBJECTIVE: To determine the associated factors, clinical characteristics, and outcomes of patients who had infective endocarditis after TAVR. DESIGN, SETTING, AND PARTICIPANTS: The Infectious Endocarditis after TAVR International Registry included patients with definite infective endocarditis after TAVR from 47 centers from Europe, North America, and South America between June 2005 and October 2015. EXPOSURE: Transcatheter aortic valve replacement for incidence of infective endocarditis and infective endocarditis for in-hospital mortality. MAIN OUTCOMES AND MEASURES: Infective endocarditis and in-hospital mortality after infective endocarditis. RESULTS: A total of 250 cases of infective endocarditis occurred in 20 006 patients after TAVR (incidence, 1.1% per person-year; 95% CI, 1.1%-1.4%; median age, 80 years; 64% men). Median time from TAVR to infective endocarditis was 5.3 months (interquartile range [IQR], 1.5-13.4 months). The characteristics associated with higher risk of progressing to infective endocarditis after TAVR was younger age (78.9 years vs 81.8 years; hazard ratio [HR], 0.97 per year; 95% CI, 0.94-0.99), male sex (62.0% vs 49.7%; HR, 1.69; 95% CI, 1.13-2.52), diabetes mellitus (41.7% vs 30.0%; HR, 1.52; 95% CI, 1.02-2.29), and moderate to severe aortic regurgitation (22.4% vs 14.7%; HR, 2.05; 95% CI, 1.28-3.28). Health care-associated infective endocarditis was present in 52.8% (95% CI, 46.6%-59.0%) of patients. Enterococci species and Staphylococcus aureus were the most frequently isolated microorganisms (24.6%; 95% CI, 19.1%-30.1% and 23.3%; 95% CI, 17.9%-28.7%, respectively). The in-hospital mortality rate was 36% (95% CI, 30.0%-41.9%; 90 deaths; 160 survivors), and surgery was performed in 14.8% (95% CI, 10.4%-19.2%) of patients during the infective endocarditis episode. In-hospital mortality was associated with a higher logistic EuroSCORE (23.1% vs 18.6%; odds ratio [OR], 1.03 per 1% increase; 95% CI, 1.00-1.05), heart failure (59.3% vs 23.7%; OR, 3.36; 95% CI, 1.74-6.45), and acute kidney injury (67.4% vs 31.6%; OR, 2.70; 95% CI, 1.42-5.11). The 2-year mortality rate was 66.7% (95% CI, 59.0%-74.2%; 132 deaths; 115 survivors). CONCLUSIONS AND RELEVANCE: Among patients undergoing TAVR, younger age, male sex, history of diabetes mellitus, and moderate to severe residual aortic regurgitation were significantly associated with an increased risk of infective endocarditis. Patients who developed endocarditis had high rates of in-hospital mortality and 2-year mortality.


Asunto(s)
Endocarditis Bacteriana/epidemiología , Endocarditis/etiología , Mortalidad Hospitalaria/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Edad , Anciano , Endocarditis Bacteriana/etiología , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca , Humanos , Masculino , Oportunidad Relativa , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Infecciones Estafilocócicas/epidemiología , Infecciones Estafilocócicas/etiología , Staphylococcus aureus , Resultado del Tratamiento
14.
J Interv Cardiol ; 28(1): 61-8, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25689549

RESUMEN

OBJECTIVES: To assess outcomes for MitraClip therapy in patients with refractory heart failure (HF) and mitral regurgitation (MR) ≥3+. BACKGROUND: The beneficial role of Mitraclip also in patients with severe HF has been reported. METHODS: Out of 45 patients undergoing MitraClip implantation at our institute, 16 were on refractory HF defined as diuretics and/or inotropics infusion and/or IABP dependence (group A) or labile haemodynamic balance (group B). RESULTS: Patients were aged 69 ± 13 years and 75% were males. Group A (8 patients) had a mean hospitalization length before MitraClip procedure of 5333 days. Group B (8 patients) had a mean rate of hospitalization, in the last 50 days before procedure, of 254 days. Acute procedural success was observed in 94% of patients. All but one patients of group A were quickly weaned from pharmacologic and/or mechanical supports within 5 ± 3 days from procedure and discharged at 20±10 days. All patients of group B were discharged after 10±8 days from MitraClip. At 1 year: a) cumulative survival rate was 78%; b) all patients were in NYHA functional class ≤ II; c) residual MR ≤ 2 was observed in 90%; d) systolic pulmonary arterial pressure was significantly reduced compared to the baseline (from 5410 to 398; p = 0,008); e) significant reduction of cumulative HF hospitalization days in the post-procedure year (10 days) compared to the pre-implantation year (280 days; p = 0.023) was observed. CONCLUSIONS: In patients with refractory HF and MR ≥3+, MitraClip implantation resulted in acute and persistent clinical benefit and net reduction of HF re-hospitalization.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Presión Arterial , Cateterismo Cardíaco , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Readmisión del Paciente/estadística & datos numéricos , Diseño de Prótesis , Arteria Pulmonar
15.
Circulation ; 128(19): 2145-53, 2013 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-24088530

RESUMEN

BACKGROUND: Little is known of the prognostic significance of mitral regurgitation (MR) on transcatheter aortic valve replacement (TAVR), the impact of TAVR on MR severity, and the variables associated with possible post-TAVR improvement in MR. We evaluated these issues in a multicenter registry of patients undergoing CoreValve Revalving System-TAVR. METHODS AND RESULTS: Among 1007 consecutive patients, 670 (66.5%), 243 (24.1%), and 94 (9.3%) presented with no/mild, moderate, and severe MR, respectively. At 1 month after TAVR, patients with severe or moderate MR showed comparable mortality rates (odds ratio, 1.1; 95% confidence interval [95% CI], 0.7-1.55; P=0.2), but both were significantly higher compared with patients with mild/no MR (odds ratio, 2.2; 95% CI, 1.78-3.28; P<0.001; and odds ratio, 1.9; 95% CI, 1.1-3.3; P=0.02, respectively). One-year mortality was also similar between patients with severe and those with moderate MR (hazard ratio, 1.4; 95% CI, 0.94-2.4; P=0.06) and still significantly higher compared with patients with mild/no MR (hazard ratio, 1.7; 95% CI, 1.2-3.41; P<0.001; and hazard ratio, 1.4; 95% CI, 1.2-2.2; P=0.03, respectively). Severe pulmonary hypertension, atrial fibrillation, and MR more than mild, but not an improvement of ≥1 grade in MR severity, were independent predictors of mortality at 1 year. At 1 year, an improved MR was observed in 47% and 35% of patients with severe and moderate MR, respectively. The rate of low implantation was consistent across groups with improved, unchanged, or worsened MR. A functional type of MR and the absence of severe pulmonary hypertension and atrial fibrillation independently predicted the improvement in MR severity. CONCLUSIONS: Baseline MR greater than mild is associated with higher mortality after CoreValve Revalving System-TAVR. A significant improvement in MR was more likely in patients with functional MR and without severe pulmonary hypertension or atrial fibrillation. The improvement in MR did not independently predict mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Insuficiencia de la Válvula Mitral/mortalidad , Anciano , Anciano de 80 o más Años , Comorbilidad , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Estimación de Kaplan-Meier , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Modelos de Riesgos Proporcionales , Sistema de Registros/estadística & datos numéricos , Índice de Severidad de la Enfermedad
16.
Catheter Cardiovasc Interv ; 84(2): 264-71, 2014 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-24408011

RESUMEN

BACKGROUND: The impact of female sex on mortality after transcatheter aortic valve implantation (TAVI) is controversial. Post-procedural aortic regurgitation (AR) ≥ 2 has been associated with poor outcomes. Whether sex differences in post-procedural AR ≥ 2 could contribute to a mortality difference between women and men is not known. METHODS: Six hundred fifty-six patients, women (53.1%), men (46.9%), with aortic stenosis underwent TAVI with the CoreValve system (92.8%) or the Edwards SAPIEN valve system (7.2%). AR was graded semiquantitatively as 0 = none, 1 = trivial, 2 = mild, 3 = moderate, and 4 = severe. The incidence of post-procedural AR ≥ 2 was reported. RESULTS: Procedural success was similar in women as compared to men (97.9 vs 96.7%, P = 0.32). Post-procedural AR ≥ 2 occurred less frequently in women than in men (20.9 vs 29.6%, P = 0.01). After a median follow-up of 434 days, all-cause mortality tended to be lower in women than in men (20.7 vs 26.6%, logrank P = 0.10), and was significantly higher in patients with AR ≥ 2 than in those without (34.8 vs 19.7%, logrank P < 0.001). AR ≥ 2 [hazard ratio (HR) 1.73, 95% confidence interval (CI) 1.22-2.43, P = 0.002], but not female sex (P = 0.17) was an independent predictor of all-cause death at multivariable Cox regression. The predictive value of AR ≥ 2 was restricted to men (HR 2.96, P < 0.001 among men; HR 0.86, P = 0.60 among women; P for interaction = 0.002). CONCLUSIONS: Women, as compared to men, present a trend toward lower mortality. A significant lower incidence of post-procedural AR ≥ 2 among women contributes to this finding. Female sex, however, was not a significant independent predictor of death.


Asunto(s)
Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/terapia , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento
17.
JAMA ; 312(2): 162-70, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25005653

RESUMEN

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Análisis de Supervivencia , Resultado del Tratamiento
18.
Am J Cardiol ; 210: 146-152, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37838072

RESUMEN

Limited data are available about the impact of permanent pacemaker (PPM) implantation on long-term survival in patients with a bicuspid aortic valve (BAV) and severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR). We aimed to evaluate the long-term clinical outcomes of patients with BAV with AS who underwent periprocedural PPM implantation after TAVR with a self-expandable prosthesis. Data from patients with BAV and severe AS who underwent TAVR between April 2009 and January 2022 and followed in the framework of the One Hospital ClinicalService-CoreValve Project were collected. Patients were categorized in 2 groups according to PPM implantation after TAVR ("PPM" group) or not ("no PPM" group). The coprimary end points were all-cause death and a composite of cardiac mortality, rehospitalization because of cardiac causes, stroke, and myocardial infarction. Overall, 106 patients were considered (74 in the "no PPM" group and 32 in the "PPM" group). No statistically significant difference was found between the groups in terms of follow-up and baseline characteristics. Patients in the PPM group were more likely to show baseline conduction abnormalities (p = 0.023). Patients in the PPM group were more often treated with older generation prosthesis than those in the no PPM group (28.1% vs 5.4%, respectively, p = 0.013). At 2 years of follow-up, all-cause death in the no PPM and PPM groups occurred in 20.0% and 10.0% of patients, respectively (hazard ratio 0.37, 95% confidence interval 0.08 to 1.67). Similarly, no difference was evident for the composite end point between the 2 groups (no PPM vs PPM: 8 [14.6%] vs 6 [19.3%], hazard ratio 1.67, 95% CI 0.58 to 4.81). In conclusion, patients with severe AS and BAV treated with TAVR complicated by PPM implantation are not exposed to an increased risk of major adverse events at 2 years of follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
19.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986659

RESUMEN

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Femenino , Masculino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Readmisión del Paciente , Recuperación de la Función , Europa (Continente) , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico , Hemodinámica
20.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA