Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 259(1): 257-262, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32529278

RESUMEN

PURPOSE: To report a retrospective series of patients implanted with a novel hydrophilic acrylic single-piece intraocular lens (IOL) designed for sutureless scleral fixation (FIL-SSF Carlevale lens, Soleko, Italy) injectable through a 2.2-mm incision. METHODS: Seventy-eight patients with minimum 6-month follow-up were divided into 6 groups: dropped nucleus, luxated IOL, trauma, aphakia, IOL exchange, and Marfan's syndrome. Surgery included peritomy and scleral flap creation at 3 and 9 o'clock position. The IOL was then injected and grasped with 25G forceps through a hole created 2 mm posterior to the limbus underneath the sculped scleral flap. RESULTS: The study included 78 patients (mean age 71.9 ± 12.6 years) and average follow-up 10.2 ± 4.2 months. Average surgery duration was 69.4 ± 26.1 min and vision significantly improved from 0.86 ± 0.56 logMAR to 0.38 ± 0.42 logMAR at 6 months post-operative (p < 0.001). Intraoperative complications included corneal edema, retinal tears, and vitreous bleeding each in 2/78 patients (2.5%); 1/78 (1.3%) localized retinal detachment and 1/78 (1.3%) rupture of one T-shaped IOL harpoon. Post-operative complications included 4/78 (5.1%) cystoid macular edemas, 2/78 retinal tears, 2/78 retinal detachments, 2/78 developed ocular hypertension, and 1/78 corneal decompensation requiring DSAEK. CONCLUSION: The Carlevale lens is designed for sutureless intrascleral fixation and can be successfully used in a variety of indications including difficult trauma cases with good rehabilitation. An implant requires experience and delicate manipulation.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Anciano , Humanos , Estudios Retrospectivos , Esclerótica/cirugía , Técnicas de Sutura , Agudeza Visual
2.
Ophthalmic Res ; 63(1): 34-40, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31352453

RESUMEN

AIM: To report the outcomes of ab externo surgery using a surgical microscope, wide-angle viewing system, and chandelier endoilluminator (microscope-assisted ab externo surgery) for rhegmatogenous retinal detachment (RRD). METHODS: This was a retrospective study. Consecutive charts of patients with RRD who underwent microscope-assisted ab externo surgery were analyzed. The following demographic parameters were analyzed: age (years), gender (male/female), and eye (right/left). Clinical parameters were axial length (AL) measured in millimeters (mm), preoperative best-corrected visual acuity (BCVA) measured in logarithm of minimum angle of resolution (logMAR), intraocular pressure (IOP), and lens status (phakic/pseudophakic). The parameters of RRD were number and type of retinal breaks, location of retinal breaks, extent of retinal detachment (RD) (number of detached quadrants), and macular detachment (MD), as well as retinal breaks not detected preoperatively. Use of cryopexy, circumferential or segmental scleral buckle, drainage of subretinal fluid, injection of air or gas, and duration of surgery were recorded. The postoperative parameters analyzed were BCVA, IOP and recurrence of RD and postoperative complications. Follow-up was established at 3 months. RESULTS: A total of 213 eyes (97 right, 116 left) of 205 patients (114 males, 91 females) affected by primary RRD were included. Fifty-two eyes (24.4%) were affected by high myopia (AL >26.5 mm), and 160 patients (75.1%) were affected by RRD caused by a single retinal break and involving only one quadrant. The superior quadrant was the most frequently involved (49.3%). Forty-two eyes (19.7%) were affected by MD. In 13 eyes (11.3%), retinal breaks were not detected preoperatively. The duration of surgery was 75.5 ± 42 min. No significant BCVA changes were observed in the whole group, whereas a significant improvement of BCVA from the baseline (2.83 ± 0.87 logMAR) to each time point of follow-up was observed in the subgroup of patients affected by MD. Six eyes (2.8%) developed a recurrent RD, secondary to proliferative vitreoretinopathy (3 eyes) and secondary to a new retinal break (3 eyes). Two eyes developed a persistent vitreous hemorrhage, and one eye developed a macular hole after 1 week. PPV was performed for both. CONCLUSION: Microscope-assisted ab externo surgery is effective and safe, it reduces discomfort, it allows the surgeon to work with both hands free, and provides an adequate visualization of each step being performed.


Asunto(s)
Crioterapia/métodos , Endotaponamiento/métodos , Procedimientos Quirúrgicos Oftalmológicos/métodos , Desprendimiento de Retina/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Microscopía/métodos , Persona de Mediana Edad , Perforaciones de la Retina/cirugía , Estudios Retrospectivos , Agudeza Visual
3.
J Craniofac Surg ; 30(8): 2544-2545, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31335575

RESUMEN

PURPOSE: The aim of this study was to describe a simple technique to insert a venous catheter as a stent for the treatment of acquired punctal and canalicular stenosis. METHODS: We performed this technique using a central venous catheter as a stent for the treatment of acquired punctal and canalicular stenosis. RESULTS: The results show the easy availability of the material used for the intervention, its easy execution, and the low costs of materials. The goal of this technique is to have a lacrimal dot dilated and canalicular duct easy to irrigate. CONCLUSION: The use of a venous catheter as a stent for treatment of acquired punctal and canalicular stenosis seems to be simple, safe, repeatable, and noninvasive.


Asunto(s)
Enfermedades de los Párpados/cirugía , Stents , Cateterismo Periférico , Constricción Patológica/cirugía , Dacriocistorrinostomía/métodos , Humanos , Aparato Lagrimal
4.
Retina ; 38(9): 1770-1776, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-28723849

RESUMEN

PURPOSE: To determine whether internal limiting membrane (ILM) peeling during pars plana vitrectomy for rhegmatogenous retinal detachment reduces the incidence of epiretinal membrane (ERM) formation. METHODS: In this retrospective study, preoperative, intraoperative, and postoperative data from all eyes undergoing pars plana vitrectomy for rhegmatogenous retinal detachment between January 2007 and December 2013 was analyzed. All cases with at least 1-year of follow-up were included. Data collection included vision, intraoperative complications, occurrence of ERM, and spectral domain optical coherence tomography characteristics. The OCTs were retrieved for all eyes and were graded by a single masked grader. RESULTS: Out of 159 eyes recruited, ILM peeling was done in 78 eyes (49%). Overall occurrence of ERM was 20%. Seven eyes (9%) in ILM peeling group and 25 eyes in the non-ILM peeling group (31%) showed ERM (P = 0.001). Postoperative vision was significantly better in eyes that had ILM peeling (0.48 ± 0.4 logarithm of the minimum angle of resolution [20/63] vs. 0.77 ± 0.6 logarithm of the minimum angle of resolution [20/125], P = 0.003). In multivariable models adjusting for type of tamponade, ILM peeling reduced the likelihood of ERM formation by 75% (P = 0.01). CONCLUSION: Internal limiting membrane peeling during pars plana vitrectomy for rhegmatogenous retinal detachment significantly reduces ERM formation in the postoperative period and is associated with better visual and anatomical outcomes.


Asunto(s)
Membrana Basal/cirugía , Membrana Epirretinal/prevención & control , Complicaciones Posoperatorias/prevención & control , Desprendimiento de Retina/cirugía , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Vitrectomía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Membrana Basal/patología , Membrana Epirretinal/epidemiología , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Desprendimiento de Retina/diagnóstico , Desprendimiento de Retina/fisiopatología , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
5.
BMC Ophthalmol ; 16(1): 50, 2016 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-27145831

RESUMEN

BACKGROUND: Several techniques for fixation of the posterior chamber intraocular lens (IOL) have been developed. We evaluate long-term functional outcomes and safety of posterior chamber IOL implantation using Hoffman scleral haptic fixation and sutureless Sharioth technique in patients with posttraumatic and postoperative aphakia. METHODS: This retrospective case-series included 42 eyes operated by one surgeon. The data including demographic data, ocular history, preoperative, early postoperative and final best corrected visual acuity (BCVA), rate of complications as well as postoperative IOL position were collected. The mean follow-up was 14.5 months. Hoffman haptic scleral fixation was performed in 31 eyes, Sharioth technique-in 11 eyes. Aphakia was due to eye trauma (19) or complicated cataract surgery (23). RESULTS: Overall, the final BCVA improved in 26 eyes, did not change in 5 eyes, and worsened in 11 eyes. No significant differences in BCVA were found between groups operated with Hoffman scleral fixation and Sharioth technique. Postoperatively, we noticed two dislocations of IOL fixated using Sharioth technique and none after Hoffman technique. No severe complications were observed. CONCLUSION: Both transscleral fixation techniques are feasible methods of secondary IOL implantation in posttraumatic and postoperative aphakia. with low incidence of complications, however visual outcomes are diverse.


Asunto(s)
Afaquia/cirugía , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Esclerótica/cirugía , Técnicas de Sutura , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Complicaciones Intraoperatorias , Implantación de Lentes Intraoculares/efectos adversos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Agudeza Visual , Adulto Joven
6.
BMC Ophthalmol ; 15: 143, 2015 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-26507387

RESUMEN

BACKGROUND: The ideal intraocular lens in cases of aphakia without capsular support is debated. Choices include anterior chamber lenses, iris- or scleral-sutured lenses, and iris-claw lenses. Our aim was to report our long-term evaluation of the use of retropupillary implantation of the Artisan iris-claw intraocular lens (RPICIOL) in several aphakic conditions without capsular support. METHODS: A retrospective analysis of consecutive 320 eyes of 320 patients (222 males and 98 females) without capsular support in which we performed RPICIOL implantation in post-traumatic aphakia (141 eyes, group 1), post-cataract surgery aphakia (122 eyes, group 2), and in cases in which penetrating keratoplasty was associated with vitrectomy (57 eyes, group 3). Either anterior or posterior vitrectomy procedures were performed with 20-, 23-, or 25-gauge techniques for different associated anterior or posterior segment indications. We reviewed the refractive outcome, anatomical outcome, long-term stability of the implants, and possible long-term complications. RESULTS: The mean patient age was 59.7 years (range, 16-84 years) in group 1; 60.1 years (range, 14-76 years) in group 2; and 65.8 years (range, 25-71.5 years) in group 3. The mean follow-up time was 5.3 years (range, 1 month to 8 years). At the end of the follow-up period, the mean post-operative best-corrected LogMAR visual acuity was 0.6 (range, perception of light to 0.3) in group 1; 0.3 (range, 0.5-0.1) in group 2; and 0.6 (range, hand movement to 0.2) in group 3. Disenclavation of RPICIOLs occurred in three cases because of slippage of one of the iris-claw haptics and spontaneous complete posterior dislocation occurred in one case. One case presented with retinal detachment, and no cases of uveitis were observed. Eight cases complained of chronic dull pain, and severe iridodonesis was seen in five cases. One case of post-operative macular edema was observed without post-operative increase in the mean intraocular pressure. There was no statistically different change in the endothelial cell density (cells/mm(2)) at the end of the follow-up period. CONCLUSIONS: RPICIOL for secondary implantations is a valid alternative strategy to scleral-fixated or angle-supported IOL implantation.


Asunto(s)
Afaquia Poscatarata/cirugía , Iris/cirugía , Implantación de Lentes Intraoculares/métodos , Subluxación del Cristalino/cirugía , Lentes Intraoculares , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Recuento de Células , Endotelio Corneal/patología , Estudios de Factibilidad , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Diseño de Prótesis , Pupila , Estudios Retrospectivos
7.
Klin Oczna ; 117(1): 5-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26349150

RESUMEN

BACKGROUND: Open globe injuries complicated with the presence of an intraocular foreign body constitute a vision threatening condition. PURPOSE: To present the results of pars plana vitrectomy in patients with intraocular foreign body. MATERIAL AND METHODS: Medical records of 22 patients were analyzed. Retrospective analysis of data included visual acuity, age, gender and type of injury. RESULTS: All patients were men and the mean age was 37 years. All injuries occurred while working with a hammer. All patients were treated with pars plana vitrectomy combined with intraocular foreign body removal and internal limiting membrane peeling. The visual acuities improved in 9 cases (41%), in 13 cases (59%) the deterioration of visual acuity was observed, no eye was enucleated. In 14 eyes pars plana vitrectomy was combined with lens removal, in 14 eyes silicone oil was used as a tamponade. CONCLUSIONS: Surgical intervention with pars plana vitrectomy combined with intraocular foreign body removal and cataract extraction may preserve severely traumatized eyes and maintain or even improve vision. ocular trauma, vitrectomy, intraocular foreign body.


Asunto(s)
Cuerpos Extraños en el Ojo/cirugía , Lesiones Oculares Penetrantes/cirugía , Desprendimiento de Retina/cirugía , Vitrectomía/métodos , Adulto , Cuerpos Extraños en el Ojo/complicaciones , Cuerpos Extraños en el Ojo/diagnóstico , Lesiones Oculares Penetrantes/complicaciones , Lesiones Oculares Penetrantes/diagnóstico , Femenino , Humanos , Implantación de Lentes Intraoculares/métodos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Desprendimiento de Retina/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual , Adulto Joven
9.
Graefes Arch Clin Exp Ophthalmol ; 251(3): 889-94, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23180235

RESUMEN

BACKGROUND: A database study to test a new model of surgical safety checklist for eye surgery in the outpatient operating room, especially for cataract surgery and intravitreal anti-VEGF injections. METHODS: WHO Surgical Safety Checklist analysis, and changes to obtain a customized surgical safety checklist for eye surgery. Testing of the new checklist in the outpatient operating room of the Institute of Ophthalmology, University of Modena during a period of 4 months (January-April 2011). All cataract surgery and intravitreal anti-VEGF operations were included in the study, and controlled by the new surgical safety checklist. The percentage of answers to each safety check was calculated to obtain an estimate of adherence to our new checklist. RESULT: Eight hundred and forty nine procedures (390 cataract, 452 anti-VEGF injections, seven combined surgery) were analyzed. The study showed a high level of adherence to the majority of the safety checks in the checklist. Important differences were identified in consent confirmation (correct confirmation in 99.76 %, no confirmation in 0.24 %), surgical site marking (correct marking in 99.29 %, no marking in 0.71 %), patient cooperation during operation (95.17 % of patients were cooperative, 4.83 % of patients were uncooperative), adherence to antibiotic prophylaxis (correct prophylaxis in 93.17 %, no prophylaxis in 6.83 %), critical situation during surgical procedures (no critical situation in 91.76 %, critical situation in 8.24 %) CONCLUSION: The study showed a high level of adherence to the checklist. A surgical safety checklist could improve the management of an eye surgery operating room.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios , Inhibidores de la Angiogénesis/administración & dosificación , Extracción de Catarata , Lista de Verificación , Quirófanos/normas , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Adulto , Anciano , Anciano de 80 o más Años , Instituciones de Atención Ambulatoria , Femenino , Adhesión a Directriz , Humanos , Inyecciones Intravítreas , Masculino , Errores Médicos/prevención & control , Persona de Mediana Edad , Control de Calidad , Indicadores de Calidad de la Atención de Salud , Gestión de Riesgos , Administración de la Seguridad/métodos , Organización Mundial de la Salud
10.
Graefes Arch Clin Exp Ophthalmol ; 251(3): 667-75, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23324893

RESUMEN

BACKGROUND: Combined post-traumatic aniridia and aphakia demand extensive and complex reconstructive surgery. We present our approach for simultaneous correction of this surgical situation with the use of the ArtificialIris (Dr. Schmidt Intraocularlinsen GmbH, Germany) with a foldable acrylic IOL Lentis L-313 (Oculentis, GmbH, Germany) sutured to its surface. The novelty (our first operation was on June 2010) of this surgical technique is based on the combined use of foldable (with closed haptics) IOL and Artificialiris to correct post-traumatic aniridia and aphakia. METHODS: Four consecutive cases of combined post-traumatic lesions of iris and lens, corrected with complex device ArtificialIris and foldable IOL. In two cases, the compound implant was sutured to the sclera in sulcus during the penetrating keratoplasty; in another case, it was positioned through a corneal incision of about 5.0 mm with transscleral fixation, and in one patient with preserved capsular support and possibility of IOL in-the-bag implantation the ArtificialIris was placed in sulcus sutureless through a clear corneal tunnel. RESULTS: Maximal follow-up was 6 months. The complex device was placed firmly fixed within the sulcus, including in the eye implanted without sutures, and showed a stable and centered position without any tilt or torque. CONCLUSION: Management of post-traumatic aniridia combined with aphakia by haptic fixation of a foldable acrylic IOL on a foldable iris prosthesis appears to be a promising approach which gives the surgeon the possibility to correct a complex lesion with one procedure, which is less traumatic and faster. Existence of foldable materials, both iris and IOL, permits relatively small corneal incisions (4.0-5.0 mm). Moreover, the custom-tailored iris prosthesis gives a perfect aesthetic result.


Asunto(s)
Aniridia/cirugía , Afaquia/cirugía , Órganos Artificiales , Lesiones Oculares Penetrantes/cirugía , Iris , Implantación de Lentes Intraoculares , Adolescente , Aniridia/etiología , Afaquia/etiología , Extracción de Catarata , Lesiones de la Cornea , Endotaponamiento , Lesiones Oculares Penetrantes/etiología , Humanos , Queratoplastia Penetrante , Persona de Mediana Edad , Aceites de Silicona/administración & dosificación , Vitrectomía
11.
Retina ; 38(5): e41-e42, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29578941
12.
J Evid Based Med ; 15(3): 302-314, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36151612

RESUMEN

Severe mechanical ocular trauma with no light perception (NLP) predicts a poor prognosis of visual acuity and enucleation of the eyeball. Since the innovative treatment concept of exploratory vitreoretinal surgery has developed and treatment technology has advanced, the outcomes of severe ocular trauma treatment in NLP patients have greatly improved. However, there remains a lack of unified standards for the determination, surgical indication, and timing of vitrectomy in NLP eye treatment. To address these problems, we aimed to create evidence-based medical guidelines for the diagnosis, treatment, and prognosis of mechanical ocular trauma with NLP. Sixteen relevant recommendations for mechanical ocular trauma with NLP were obtained, and a consensus was reached. Each recommendation was explained in detail to guide the treatment of mechanical ocular trauma associated with NLP.


Asunto(s)
Lesiones Oculares Penetrantes , Lesiones Oculares Penetrantes/diagnóstico , Lesiones Oculares Penetrantes/cirugía , Humanos , Pronóstico , Estudios Retrospectivos , Agudeza Visual , Vitrectomía
13.
J Cataract Refract Surg ; 47(6): 792-801, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-33278236

RESUMEN

Cataract surgery via phacoemulsification with intraocular lens (IOL) placement in the capsular bag is the gold standard in the presence of adequate capsular support. However, when capsule and/or zonular fibers are weak or absent, alternate fixation strategies are required. Common alternative options include retropupillary iris-claw IOLs (RP-IC IOLs) and scleral-fixated IOLs (SF IOLs). In the present review of 87 articles with 2174 eyes implanted with RP-IC IOLs and 2980 eyes with SF IOLs, we discuss the published literature with respect to safety and efficacy. Although the studies reporting outcomes of these IOLs have been performed in patients with different concomitant conditions, visual and refractive outcomes were found to be comparable between RP-IC IOLs and SF IOLs. RP-IC IOL implantation seemed to provide equivalent or a potentially lower rate of complications than SF IOL implantation. Data from the literature also suggest that the surgical technique of RP-IC IOL implantation is relatively simpler with correspondingly shorter surgical times.


Asunto(s)
Cristalino , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Esclerótica/cirugía
14.
J Cataract Refract Surg ; 47(3): 316-322, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32991506

RESUMEN

PURPOSE: To evaluate the optic plate and haptics of a specially designed sutureless intrascleral-fixated intraocular lens (IOL) using ultrasound biomicroscopy and anterior segment optical coherence tomography (AS-OCT). SETTING: Department of Ophthalmology, San Marino Hospital, Republic of San Marino. DESIGN: Retrospective observational case series. METHODS: Eyes that underwent intrascleral fixation with IOL implantation (Carlevale) were included. Preoperative and postoperative refractive outcomes were reported. Optic plate tilt and haptics position were assessed with ultrasound biomicroscopy, whereas intrascleral plug depth and conformation were evaluated with AS-OCT. RESULTS: The study comprised 10 aphakic eyes. Postoperative visual acuity improved in all patients. At postoperative month 3, 3 eyes (30%) had a vertical tilt of more than 100 µm, whereas no horizontal tilt was observed in any patient. The mean vertical intraocular tilt was 0.19 ± 0.22 mm. Of 20 haptics, 13 (65%) passed through the ciliary sulcus, 4 (20%) posterior to the ciliary body, and 3 (15%) through the ciliary body. AS-OCT scans showed a mean intrascleral plug depth of 247.20 ± 62.82 µm in the nasal sector and 265.50 ± 30.11 µm in the temporal sector, with adequate integration of the T-shaped plugs in the scleral tissue. CONCLUSIONS: This secondary IOL showed good intraocular stability and safe haptics fixation, making it suitable for the intrascleral fixation technique. The specific foldable design results in a low predisposition to optic plate tilt and haptic torsion. In long eyes, the sulcus-to-sulcus distance should be carefully evaluated preoperatively because the flexible structure of the IOL could be subjected to excessive stretching.


Asunto(s)
Lentes Intraoculares , Microscopía Acústica , Humanos , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Esclerótica/diagnóstico por imagen , Esclerótica/cirugía , Tomografía de Coherencia Óptica
15.
Am J Ophthalmol Case Rep ; 23: 101179, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34381925

RESUMEN

PURPOSE: to report the utility of Anterior Segment Optical Coherence Tomography (AS OCT) for planning superficial sclerectomy in a patient with nevus of Ota. OBSERVATIONS: Oculodermal melanocytosis, also called nevus of Ota, is a benign pigmentary disorder that involves the skin innervated by the first and second branches of the trigeminal nerve. To reduce these black or brownish lesions, different surgical treatments have been reported, such as flipped scleral flap, sclera allograft and the grabbing method. Superficial sclerectomy is a recent technique that has proven effective in improving scleral pigmentation. Although this procedure allows the operating time to be reduced and results in a smoother scleral bed surface, it has a limitation, represented by the difficulty of estimating the depth of the sclerectomy: an inaccurate estimate or incorrect depth could cause an inadequate deep scleral dissection with excessive weakening of the sclera. We report a case of a 27-year-old patient with nevus of Ota undergoing superficial sclerectomy. The depth of scleral pigmentation was evaluated with AS OCT images before the surgery, allowing a superficial sclerectomy to be performed with a precalibrated diamond blade. CONCLUSIONS AND IMPORTANCE: In oculodermal melanocytosis (nevus of Ota) the use of AS OCT images showing the depth of scleral pigmentation could lead to the most effective and safest surgical choice for each case.

16.
J Ophthalmol ; 2021: 9933486, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34557313

RESUMEN

PURPOSE: To evaluate the efficacy and safety of the following three distinct surgical procedures for secondary IOL implantation without capsular support: Iris-claw lens, flanged transscleral fixated IOLs (Yamane technique), and sutureless transscleral hook IOL fixation (Carlevale IOL). MATERIALS AND METHODS: In this retrospective comparative study, three different sutureless IOL implantation techniques were compared in patients without any capsular support. Visual acuity and outcomes were analyzed in 24 eyes of 23 patients (14 male and 9 female). Study included 13 iris-claw lenses (Artisan Ophtec), 6 flanged transscleral fixated IOLs (Yamane technique using a MA60MA Alcon Inc IOL), and 5 transscleral Carlevale IOLS (Carlevale IOL, Soleko, Italy). RESULTS: logMAR mean best-corrected visual acuity (BCVA) improved from 0.49 ± 0.19 to 0.19 ± 0.10 at three months after surgery (p < 0.05). Postoperative BCVA was similar in all three groups, and no intergroup difference was noted. Three eyes (12.5%) had a raised IOP >25 mmHg, 2 eyes (8%) presented a subluxated/dislocated IOL, 4 eyes (16%) had corneal edema longer than 7 days, 3 eyes (12.5%) had irregular pupil profile, 2 eyes (8%) had vitreous hemorrhage, 7 eyes had (29%) corneal astigmatism over 3 diopters, and one patient (4%) developed cystoid macular edema (CME). CONCLUSIONS: All three surgical procedures can be considered adequate to correct aphakia in patients without capsular support with significant improvement in visual acuity and low complication.

17.
J Ophthalmol ; 2021: 3838456, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34484813

RESUMEN

PURPOSE: To assess one year results and stability of the implantation of a scleral anchored intraocular lens (IOL). DESIGN: Interventional prospective case series. METHODS: Sixty eyes of 60 patients affected by either aphakia or IOL dislocation were included in this study. Patients underwent vitrectomy, scleral fixation of the IOL, and, if present, dislocated IOL removal. Patients were evaluated preoperatively and at 1, 3, 6, and 12 months after surgery by best-corrected distance visual acuity (BCVA) assessment, intraocular pressure (IOP) measurement, corneal specular microscopy, and optical coherence tomography (OCT) of both the macula and anterior segment. RESULTS: At twelve months, mean BCVA significantly improved (p < 0.0001), and none of the patients experienced a decrease of visual acuity. A 10% decrease of endothelial cell count occurred after surgery. Cystoid macular edema occurred in three patients (5%). A transient increase of intraocular pressure was noted in 7 cases (12%). At one month, horizontal and vertical IOL tilt was 1.04 ± 0.87 and 0.74 ± 0.71 degrees, respectively, and did not significantly change in the follow-up (p > 0.05). None of the patients had decentration or dislocation of scleral-fixated IOL during the follow-up. CONCLUSION: Implantations of scleral plug fixated IOL provide good visual results, low complication rate, and excellent stability of the lens until one-year follow-up.

18.
J Ophthalmol ; 2020: 8891057, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33414956

RESUMEN

AIM: This study aims to evaluate the morphology of ganglion cell complex (GCC) along with functional outcomes in patients undergoing vitrectomy with ILM peeling and macular abrasion with Tano diamond dusted membrane scrapers (DDMS) for three different stages of the idiopathic macular hole (IMH). METHODS: This retrospective study was conducted between April 2019 and December 2019. 33 patients with IMH were included and divided into three groups: stage I, stage II, and stage IV. All patients were subjected to vitrectomy with ILM peeling. Gentle and vigorous macular abrasion was additionally performed for stage II and stage IV patients, respectively. The best-corrected visual acuity (BCVA), GCC thickness (measured by spectral domain-optical coherence tomography (SD-OCT)), and photopic contrast sensitivity (Rodenstock CV 900 Chart Panel) were determined before surgery and at 1- and 3-month follow-ups. RESULTS: Closure of MH was achieved in all the patients. The difference between the preoperative and one- and three-month postoperative values of BCVA was statistically significant in the three groups (P < 0.01). Contrast sensitivity progressively improved in all patients and was statistically significant (P < 0.01). The reduction in GCC thickness during follow-up was 34%-42% of the preoperative measurements. On comparing the mean GCC thickness of the operated and healthy eyes, it was not statistically significant in stage I patients. However, the same when done in stage II and IV was statistically significant with P value < 0.05 and P < 0.01, respectively. CONCLUSION: Combining ILM peeling with macular abrasion in advanced stages of MH may facilitate its closure without significantly affecting the functional outcome.

19.
J Ophthalmol ; 2020: 6871207, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33149943

RESUMEN

PURPOSE: To evaluate whether limited vitrectomy is as effective as complete vitrectomy in eyes with epiretinal membrane (ERM) and to compare the surgical times and rates of complications. METHODS: In this multicentre European study, data of eyes with ERM that underwent vitrectomy from January 2017 to July 2018 were analyzed retrospectively. In the limited vitrectomy group, a posterior vitreous detachment (PVD) was induced up till the equator as opposed to complete PVD induction till the vitreous base in the comparison group. Incidence of iatrogenic retinal breaks, retinal detachment, surgical time, and visual outcomes were compared between groups. RESULTS: We included 139 eyes in the analysis with a mean age being 72.2 ± 6.9 years. In this, sixty-five eyes (47%) underwent limited vitrectomy and 74 eyes (53%) underwent complete vitrectomy. Iatrogenic retinal tears were seen in both groups (5% in limited vitrectomy versus 7% in complete vitrectomy, p=0.49). Retinal detachment occurred in 2 eyes in the limited vitrectomy group (3%) compared to none in the complete vitrectomy group (p=0.22). Best-corrected visual acuity (BCVA) and central macular thickness improved significantly with no intergroup differences (p=0.18). Surgical time was significantly shorter in the limited vitrectomy group with 91% surgeries taking less than 1 hour compared to 71% in the complete vitrectomy group (p < 0.001). CONCLUSION: A limited vitrectomy is a time-efficient and effective surgical procedure for removal of epiretinal membrane with no additional complications.

20.
J Clin Med ; 9(2)2020 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-32098215

RESUMEN

Remarkable improvements in optical coherence tomography (OCT) technology have resulted in highly sophisticated, noninvasive machines allowing detailed and advanced morphological evaluation of all retinal and choroidal layers. Postproduction semiautomated imaging analysis with dedicated public-domain software allows precise quantitative analysis of binarized OCT images. In this regard, the choroidal vascularity index (CVI) is emerging as a new imaging tool for the measurement and analysis of the choroidal vascular system by quantifying both luminal and stromal choroidal components. Numerous reports have been published so far regarding CVI and its potential applications in healthy eyes as well as in the evaluation and management of several chorioretinal diseases. Current literature suggests that CVI has a lesser variability and is influenced by fewer physiologic factors as compared to choroidal thickness. It can be considered a relatively stable parameter for evaluating the changes in the choroidal vasculature. In this review, the principles and the applications of this advanced imaging modality for studying and understanding the contributing role of choroid in retinal and optic nerve diseases are discussed. Potential advances that may allow the widespread adoption of this tool in the routine clinical practice are also presented.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA