Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Vasc Endovasc Surg ; 43(5): 499-503, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22342694

RESUMEN

OBJECTIVES: The aim was internal vascular centre quality-control measures to compare single-centre results with the national perspective, as well as analysing the Swedish results from carotid artery stenting (CAS) and comparing a relatively high-volume single centre with the Swedish Vascular Registry (Swedvasc) data. The second aim was to compare CAS and carotid artery endarterectomy (CEA) outcomes for the same 7-year period. DESIGN: Retrospective review of a single high-volume centre (Södersjukhuset (SÖS)) (approximately 30 CAS year(-1) approximately 90 CEA year(-1)) versus Swedvasc National data. MATERIALS AND METHODS: All consecutive selective patients treated with CAS at SÖS for a stenosis of the internal carotid artery (n = 208) or CEA (n = 552) between 2004 and 2011 were compared with all patients in Swedvasc registered for CAS (n = 258) and CEA (n = 6474). Primary outcome was 30-day frequency of stroke or death. Secondary outcome was stroke/death/acute myocardial infarction (AMI). RESULTS: The 30-day frequency of any stroke or death after CAS at SÖS compared to the national data was 2.9% and 7.4%, respectively (P = 0.04). The 30-day AMI/stroke/death frequency was 3.4% and 9.5%, respectively (P = 0.01). After CEA during the same time period, the Swedvasc national data had a 4.4% frequency of 30-day stroke and death and 5.8% for AMI/stroke/death. CONCLUSIONS: CAS is not as safe as CEA from a national perspective but our results indicate that a single centre can achieve acceptable results with CAS.


Asunto(s)
Arteria Carótida Interna/cirugía , Estenosis Carotídea/terapia , Endarterectomía Carotidea , Implantación de Prótesis , Stents , Anciano , Estenosis Carotídea/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Control de Calidad , Sistema de Registros , Estudios Retrospectivos , Accidente Cerebrovascular , Suecia , Resultado del Tratamiento
2.
Scand J Surg ; 99(4): 226-9, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21159593

RESUMEN

BACKGROUND AND AIMS: This retrospective study was undertaken to examine the risks associated with obstruction of the coeliac trunk in the process of treating aneurysms with endografting. MATERIAL AND METHODS: 120 patients were treated by endografting for aneurysmal disease. Of these, a subgroup of 9 patients had their celiac trunk covered. If possible, a preoperative angiography was performed to evaluate collateral flow from the superior mesenteric artery. This was considered to predict the risk for ischemia. RESULTS: None of the patients had any severe clinical event of the celiac trunk occlusion or clinical signs of intestinal ischemia. Three patients had transient increase of liver enzymes. CONCLUSIONS: In cases where the distal landing zone of the descending thoracic aorta is to short for endografting, covering of the celiac trunk may be an option if no other surgical alter-native is apparent. Preoperative angiography to visualise the presence of collateral vessels from the superior mesenteric artery is recommended.


Asunto(s)
Angioplastia , Aneurisma de la Aorta/terapia , Oclusión con Balón , Arteria Celíaca , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/etiología , Implantación de Prótesis Vascular , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Stents
3.
Arterioscler Thromb ; 14(2): 261-4, 1994 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-8305418

RESUMEN

To evaluate ultrasonographically determined intima-media thickness as a measure of early atherosclerosis, three studies were performed. Ultrasound measurements of intima-media thickness in the carotid artery were directly validated by comparing the same thickness measured by light microscopy. The values were closely correlated (r = .82, P < .001). Intima-media thickness determined by light microscopy was consistently smaller than that determined by ultrasound, probably due to shrinkage during histological preparation. As an indirect validation, mean intima-media thickness was calculated in three large groups of patients with no plaque (n = 224), one plaque (n = 105), and one circumferential or two or more plaques (n = 54) in the carotid bifurcation. Intima-media thickness increased significantly with increasing plaque score, indicating that diffuse intima-media thickening is more pronounced with more severe atherosclerosis. The intima-media thickness also increased with increasing multifactorial cardiovascular risk, reflecting a positive relation between signs of early atherosclerosis and the burden of known risk factors for the disease. Our studies support earlier findings that have found that ultrasonographically determined intima-media thickness is a valid way to study early atherosclerosis.


Asunto(s)
Arteriosclerosis/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Túnica Íntima/diagnóstico por imagen , Túnica Media/diagnóstico por imagen , Arteriosclerosis/patología , Enfermedades Cardiovasculares/etiología , Arterias Carótidas/patología , Estudios de Evaluación como Asunto , Humanos , Factores de Riesgo , Túnica Íntima/patología , Túnica Media/patología , Ultrasonografía
4.
Arterioscler Thromb ; 12(2): 261-6, 1992 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-1543698

RESUMEN

A noninvasive method based on high-resolution B-mode ultrasonography and a computerized image-analyzing system were used for the quantification of early (thickening of the intima-media complex) and late (plaque) atherosclerosis in the carotid and the femoral artery. The difference between repeated measurements was assessed to estimate intraobserver and interobserver differences. The results were satisfactory, with a coefficient of variation for measurement of lumen diameter in the common carotid artery of 3.8 +/- 4.1% (r = 0.91) and for the femoral artery of 4.8 +/- 4.1% (r = 0.93). Corresponding figures for intima-media thickness in the common carotid artery and the femoral artery were 10.0 +/- 8.5% (r = 0.86) and 16.2 +/- 12.6% (r = 0.91), respectively. The coefficient of variation for measurements of maximal intima-media thickness at the site of the plaque was 14.6 +/- 10.5% (r = 0.88); for plaque base, 13.1 +/- 9.0% (r = 0.91); and for plaque area, 16.3 +/- 12.6% (r = 0.90). The method seems promising for the detection and quantification of early and late atherosclerotic lesions in the carotid and femoral arteries.


Asunto(s)
Arteriosclerosis/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Arteria Femoral/diagnóstico por imagen , Anciano , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA