Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Epilepsy Behav ; 161: 110034, 2024 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-39306979

RESUMEN

OBJECTIVES: As epilepsy management medical devices emerge as potential technological solutions for prediction and prevention of sudden death in epilepsy (SUDEP), there is a gap in understanding the features and priorities that should be included in the design of these devices. This study aims to bridge the gap between current technology and emerging needs by leveraging insights from persons with epilepsy (PWE) and caregivers (CG) on current epilepsy management devices and understanding how SUDEP awareness influences preferences and design considerations for potential future solutions. METHODS: Two cross-sectional surveys were designed to survey PWE and CG on medical device design features, SUDEP awareness, and participation in medical device research. Data analysis included both qualitative thematic analysis and quantitative statistical analysis. RESULTS: The survey revealed that among 284 responses, CG were more aware of SUDEP than PWE. Comfort was identified as the primary concern regarding wearable medical devices for epilepsy management with significant differences between PWE and CG regarding acceptance and continuous use preferences. The thematic analysis identified integration with daily life, aesthetic and emotional resonance, adaptability to seizure characteristics, and user-centric design specifications as crucial factors to be considered for enhanced medical device adoption. The integration of a companion app is seen as an important tool to enhance communication and data sharing. DISCUSSION: This study reveals that while SUDEP awareness can promote the development of future SUDEP predictive and preventive medical devices, these should be designed to mitigate its impact on daily life and anxiety of both PWE and CG. Comfort and acceptance are seen as key priorities to support continuous use and are seen as a technical requirement of future medical devices for SUDEP prediction and prevention. Widespread adoption requires these technologies to be customizable to adapt to different lifestyles and social situations. A holistic approach should be used in the design of future medical devices to capture several dimensions of PWE and CG epilepsy management journey and uphold communication between healthcare professionals, PWE and CG. CONCLUSION: Data from this study highlight the importance of considering user preferences and experiences in the design of epilepsy management medical devices with potential applicability for SUDEP prediction and prevention. By employing user-centered design methods this research provides valuable insights to inform the development of future SUDEP prediction and prevention devices.

2.
Vet Pathol ; 56(2): 208-219, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30381007

RESUMEN

Histopathology remains the cornerstone for diagnosing canine mammary tumors (CMTs). Recently, 2 classification systems (the World Health Organization [WHO] classification of 1999 and the proposal of 2011) and 2 grading methods based on the human Nottingham grade have been used by pathologists. Despite some evidence that the histological subtype and grade are prognostic factors, there is no comprehensive comparative study of these classification and grading systems in the same series of CMTs. In this study, the 2 classifications and the 2 grading methods were simultaneously applied to a cohort of 134 female dogs with CMTs. In 85 animals with malignant tumors, univariable and multivariable survival analyses were performed. Using the 2 systems, the proportion of benign (161/305, 53%) and malignant (144/305, 47%) tumors was similar and no significant differences existed in categorization of benign tumors. However, the 2011 classification subdivided malignant tumors in more categories-namely, those classified as complex, solid, and tubulopapillary carcinomas by the WHO system. Histological subtype according to both systems was significantly associated with survival. Carcinomas arising in benign tumors, complex carcinomas, and mixed carcinomas were associated with a better prognosis. In contrast, carcinosarcomas and comedocarcinomas had a high risk of tumor-related death. Slight differences existed between the 2 grading methods, and grade was related to survival only in univariable analysis. In this cohort, age, completeness of surgical margins, and 2 index formulas adapted from human breast cancer studies (including tumor size, grade, and vascular/lymph node invasion) were independent prognostic factors.


Asunto(s)
Enfermedades de los Perros/clasificación , Neoplasias Mamarias Animales/clasificación , Clasificación del Tumor/veterinaria , Animales , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/mortalidad , Enfermedades de los Perros/patología , Perros , Femenino , Glándulas Mamarias Animales/patología , Neoplasias Mamarias Animales/diagnóstico , Neoplasias Mamarias Animales/mortalidad , Neoplasias Mamarias Animales/patología , Pronóstico , Análisis de Supervivencia
3.
Biomater Res ; 22: 38, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30619619

RESUMEN

Autologous bone remains the gold standard grafting substrate for bone fusions used for small gaps and critical defects. However, significant morbidity is associated with the harvesting of autologous bone grafts and, for that reason, alternative bone graft substitutes have been developed. In the present case series, a glass-reinforced hydroxyapatite synthetic bone substitute, with osteoinductive and osteoconductive proprieties, was applied. This synthetic bone substitute comprises the incorporation of P2O5-CaO glass-based system within a hydroxyapatite matrix, moulded into spherical pellets with 250-500 µm of diameter. A total of 14 veterinary clinical cases of appendicular bone defects and maxillary / mandibular bone defects are described. In all clinical cases, the synthetic bone substitute was used to fill bone defects, enhancing bone regeneration and complementing the recommended surgical techniques. Results demonstrated that it is an appropriate synthetic bone graft available to be used in veterinary patients. It functioned as a space filler in association with standard orthopaedic and odontological procedures of stabilization, promoting a faster bone fusion without any local or systemic adverse reactions. This procedure improves the animals' quality of life, decreasing pain and post-operative recovery period, as well as increasing bone stability improving positive clinical outcomes.

4.
World J Stem Cells ; 7(6): 956-75, 2015 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-26240682

RESUMEN

AIM: To study the therapeutic effect of three tube-guides with electrical conductivity associated to mesenchymal stem cells (MSCs) on neuro-muscular regeneration after neurotmesis. METHODS: Rats with 10-mm gap nerve injury were tested using polyvinyl alcohol (PVA), PVA-carbon nanotubes (CNTs) and MSCs, and PVA-polypyrrole (PPy). The regenerated nerves and tibialis anterior muscles were processed for stereological studies after 20 wk. The functional recovery was assessed serially for gait biomechanical analysis, by extensor postural thrust, sciatic functional index and static sciatic functional index (SSI), and by withdrawal reflex latency (WRL). In vitro studies included cytocompatibility, flow cytometry, reverse transcriptase polymerase chain reaction and karyotype analysis of the MSCs. Histopathology of lung, liver, kidneys, and regional lymph nodes ensured the biomaterials biocompatibility. RESULTS: SSI remained negative throughout and independently from treatment. Differences between treted groups in the severity of changes in WRL existed, showing a faster regeneration for PVA-CNTs-MSCs (P < 0.05). At toe-off, less acute ankle joint angles were seen for PVA-CNTs-MSCs group (P = 0.051) suggesting improved ankle muscles function during the push off phase of the gait cycle. In PVA-PPy and PVA-CNTs groups, there was a 25% and 42% increase of average fiber area and a 13% and 21% increase of the "minimal Feret's diameter" respectively. Stereological analysis disclosed a significantly (P < 0.05) increased myelin thickness (M), ratio myelin thickness/axon diameter (M/d) and ratio axon diameter/fiber diameter (d/D; g-ratio) in PVA-CNT-MSCs group (P < 0.05). CONCLUSION: Results revealed that treatment with MSCs and PVA-CNTs tube-guides induced better nerve fiber regeneration. Functional and kinematics analysis revealed positive synergistic effects brought by MSCs and PVA-CNTs. The PVA-CNTs and PVA-PPy are promising scaffolds with electric conductive properties, bio- and cytocompatible that might prevent the secondary neurogenic muscular atrophy by improving the reestablishment of the neuro-muscular junction.

5.
Neural Regen Res ; 7(29): 2247-58, 2012 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25538746

RESUMEN

Many studies have been dedicated to the development of scaffolds for improving post-traumatic nerve regeneration. The goal of this study was to assess the effect on nerve regeneration, associating a hybrid chitosan membrane with non-differentiated human mesenchymal stem cells isolated from Wharton's jelly of umbilical cord, in peripheral nerve reconstruction after crush injury. Chromosome analysis on human mesenchymal stem cell line from Wharton's jelly was carried out and no structural alterations were found in metaphase. Chitosan membranes were previously tested in vitro, to assess their ability in supporting human mesenchymal stem cell survival, expansion, and differentiation. For the in vivo testing, Sasco Sprague adult rats were divided in 4 groups of 6 or 7 animals each: Group 1, sciatic axonotmesis injury without any other intervention (Group 1-Crush); Group 2, the axonotmesis lesion of 3 mm was infiltrated with a suspension of 1 250-1 500 human mesenchymal stem cells (total volume of 50 µL) (Group 2-CrushCell); Group 3, axonotmesis lesion of 3 mm was enwrapped with a chitosan type III membrane covered with a monolayer of non-differentiated human mesenchymal stem cells (Group 3-CrushChitIIICell) and Group 4, axonotmesis lesion of 3 mm was enwrapped with a chitosan type III membrane (Group 4-CrushChitIII). Motor and sensory functional recovery was evaluated throughout a healing period of 12 weeks using sciatic functional index, static sciatic index, extensor postural thrust, and withdrawal reflex latency. Stereological analysis was carried out on regenerated nerve fibers. Results showed that infiltration of human mesenchymal stem cells, or the combination of chitosan membrane enwrapment and human mesenchymal stem cell enrichment after nerve crush injury provide a slight advantage to post-traumatic nerve regeneration. Results obtained with chitosan type III membrane alone confirmed that they significantly improve post-traumatic axonal regrowth and may represent a very promising clinical tool in peripheral nerve reconstructive surgery. Yet, umbilical cord human mesenchymal stem cells, that can be expanded in culture and induced to form several different types of cells, may prove, in future experiments, to be a new source of cells for cell therapy, including targets such as peripheral nerve and muscle.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA