Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
PLoS One ; 17(9): e0269329, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36166414

RESUMEN

BACKGROUND: As new SARS-CoV-2 variants of concern emerge, there is a need to scale up testing to minimize transmission of the Coronavirus disease 2019 (COVID-19). Many countries especially those in the developing world continue to struggle with scaling up reverse transcriptase polymerase reaction (RT-PCR) to detect SARS-CoV-2 due to scarcity of resources. Alternatives such as antigen rapid diagnostics tests (Ag-RDTs) may provide a solution to enable countries scale up testing. METHODS: In this study, we evaluated the Panbio™ and STANDARD Q Ag-RDTs in the laboratory using 80 COVID-19 RT-PCR confirmed and 80 negative nasopharyngeal swabs. The STANDARD Q was further evaluated in the field on 112 symptomatic and 61 asymptomatic participants. RESULTS: For the laboratory evaluation, both tests had a sensitivity above 80% (Panbio™ = 86% vs STANDARD Q = 88%). The specificity of the Panbio™ was 100%, while that of the STANDARD Q was 99%. When evaluated in the field, the STANDARD Q maintained a high specificity of 99%, however the sensitivity was reduced to 56%. CONCLUSION: Using Ag-RDTs in low resource settings will be helpful in scaling-up SARS-CoV-2 testing, however, negative results should be confirmed by RT-PCR where possible to rule out COVID-19 infection.


Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales/análisis , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Namibia/epidemiología , ADN Polimerasa Dirigida por ARN , SARS-CoV-2/genética , Sensibilidad y Especificidad
2.
J Acquir Immune Defic Syndr ; 87(Suppl 1): S67-S72, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34166314

RESUMEN

BACKGROUND: In the population-based HIV impact assessment surveys, early infant diagnosis (EID) was provided to infants <18 months without a prior diagnosis. For the Namibia population-based HIV impact assessment (NAMPHIA), the GeneXpert platform was assessed for the feasibility of near POC EID testing compared with the standard Roche COBAS AmpliPrep/COBAS TaqMan (CAP/CTM) platform. Quality assurance measures and turnaround time were compared to improve EID results reporting. METHODS: NAMPHIA participants were screened for HIV exposure using Determine HIV-1/2 rapid test; samples reactive on Determine received EID testing on the GeneXpert instrument and Xpert HIV-1 Qual assay using whole blood. Results were confirmed at the Namibia Institute of Pathology using dried blood spots on the Roche CAP/CTM platform per national guidelines. RESULTS: Of the 762 screened infants, 61 (8.0%) were Determine-reactive and considered HIV-exposed. Of the 61 exposed infants, 2 were found to be HIV-infected whereas 59 were negative on both GeneXpert and Roche platforms, achieving 100% concordance. Average turnaround time was 3.4 days for the Xpert HIV-1 Qual assay, and average time from collection to testing was 1.0 days for GeneXpert compared with 10.7 days for Roche. No samples failed using GeneXpert whereas 1 sample failed using Roche and was repeated. CONCLUSION: Quality POC EID testing is feasible in a national survey through extensive training and external quality assurance measures. The use of decentralized POC EID for national testing would provide rapid diagnosis and improve TATs which may prevent loss to follow-up, ensure linkage to care, and improve clinical outcomes for infants.


Asunto(s)
Monitoreo Epidemiológico , Infecciones por VIH/diagnóstico , Prueba de VIH/métodos , VIH-1 , Encuestas Epidemiológicas , Pruebas en el Punto de Atención , Países en Desarrollo , Femenino , Humanos , Lactante , Recién Nacido , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA