Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Breast Cancer Res Treat ; 166(2): 501-509, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28780702

RESUMEN

BACKGROUND: Most published studies evaluating digital breast tomosynthesis (DBT) included a separate 2-dimensional full-field digital mammogram (FFDM) for DBT screening protocols, increasing radiation from screening mammography. Synthesized mammography (SM) creates a 2-dimensional image from the DBT source data, and if used in place of FFDM, it reduces radiation of DBT screening. This study evaluated the implementation of SM + DBT in routine screening practice in terms of recall rates, cancer detection rates (CDR), % of minimal cancers, % of node-positive cancers, and positive predictive values (PPV). MATERIALS AND METHODS: A multivariate retrospective institutional analysis was performed on 31,979 women who obtained screening mammography (10/2013-12/2015) with cohorts divided by modality (SM + DBT, FFDM + DBT, and FFDM). We adjusted for comparison mammograms, age, breast density, and the interpreting radiologist. Recall type was analyzed for differences (focal asymmetry, asymmetry, masses, calcifications, architectural distortion). RESULTS: SM + DBT significantly decreased the recall rate compared to FFDM (5.52 vs. 7.83%, p < 0.001) with no differences in overall CDR (p = 0.66), invasive and/or in situ CDR, or percentages of minimal and node-negative cancers. PPV1 significantly increased with SM + DBT relative to FFDM (9.1 vs. 6.2%, p = 0.02). SM + DBT did not differ significantly in recall rate or overall CDR compared to FFDM + DBT. There were statistically significant differences in certain findings recalled by screening modality (e.g., focal asymmetries). CONCLUSIONS: SM + DBT reduces false positives compared to FFDM, while maintaining the CDR and other desirable audit outcome data. SM + DBT is more accurate than FFDM alone, and is a desirable alternative to FFDM + DBT, given the added benefit of radiation reduction.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Densidad de la Mama , Detección Precoz del Cáncer , Femenino , Humanos , Tamizaje Masivo , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Breast Cancer Res Treat ; 153(3): 699-702, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26341750

RESUMEN

Mammography and ultrasound are often used concurrently for patients with palpable breast masses. While mammography has a false-negative rate of approximately 15 %, the addition of breast ultrasound decreases this rate among patients with palpable breast masses. There are no recent outcome data regarding the use of combined reporting of ultrasound and mammography (CRUM) for palpable breast masses. In this study, female patients presenting with a palpable breast mass were retrospectively reviewed in a prospectively entered database at a single institution from June 2010 to July 2013. All cancer cases and false-negative cases using CRUM were identified. Cancer rates, false-negative rates, and negative predictive values were calculated based on CRUM breast imaging-reporting and data system (BI-RADS) categories. One thousand two hundreds and twelve female patients presenting with a palpable breast mass were identified; 77 % of patients had CRUM and 73 % (682/932) were BI-RADS 1-2. Despite negative or benign BI-RADS, 9.5 % of patients with BI-RADS 1-2 (65/682) underwent biopsy, compared to 96 % of patients with a BI-RADS 4-5 designation. Eighty-one patients were found to have cancers; 2 had BI-RADS 1-2 imaging. The false-negative rate of CRUM was 2.4 % (2/81). Since 69 % (428/617) of BI-RADS 1-2 patients without tissue diagnosis had follow-up imaging and/or clinical exam (median: 27 months, range: 2-62 months) and none developed cancers, the cancer rate and negative predictive value of a palpable breast mass of BI-RADS 1-2 were estimated to be 0.3 % (2/682) and 99.7 %, respectively. In the modern era of combined imaging for breast masses, a patient with a low suspicion exam can be reassured with a negative CRUM report.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Mama/patología , Mamografía , Ultrasonografía Mamaria , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Neoplasias de la Mama/cirugía , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
3.
Breast Cancer Res Treat ; 153(2): 455-64, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26290416

RESUMEN

Stemming from breast density notification legislation in Massachusetts effective 2015, we sought to develop a collaborative evidence-based approach to density notification that could be used by practitioners across the state. Our goal was to develop an evidence-based consensus management algorithm to help patients and health care providers follow best practices to implement a coordinated, evidence-based, cost-effective, sustainable practice and to standardize care in recommendations for supplemental screening. We formed the Massachusetts Breast Risk Education and Assessment Task Force (MA-BREAST) a multi-institutional, multi-disciplinary panel of expert radiologists, surgeons, primary care physicians, and oncologists to develop a collaborative approach to density notification legislation. Using evidence-based data from the Institute for Clinical and Economic Review, the Cochrane review, National Comprehensive Cancer Network guidelines, American Cancer Society recommendations, and American College of Radiology appropriateness criteria, the group collaboratively developed an evidence-based best-practices algorithm. The expert consensus algorithm uses breast density as one element in the risk stratification to determine the need for supplemental screening. Women with dense breasts and otherwise low risk (<15% lifetime risk), do not routinely require supplemental screening per the expert consensus. Women of high risk (>20% lifetime) should consider supplemental screening MRI in addition to routine mammography regardless of breast density. We report the development of the multi-disciplinary collaborative approach to density notification. We propose a risk stratification algorithm to assess personal level of risk to determine the need for supplemental screening for an individual woman.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Detección Precoz del Cáncer , Medicina Basada en la Evidencia/legislación & jurisprudencia , Glándulas Mamarias Humanas/anomalías , Algoritmos , Densidad de la Mama , Manejo de la Enfermedad , Detección Precoz del Cáncer/métodos , Detección Precoz del Cáncer/normas , Medicina Basada en la Evidencia/normas , Femenino , Humanos , Imagen por Resonancia Magnética , Mamografía , Massachusetts , Medición de Riesgo , Ultrasonografía Mamaria
4.
Radiology ; 275(2): 377-83, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25575115

RESUMEN

PURPOSE: To assess the feasibility and accuracy of digital breast tomosynthesis (DBT)-guided needle localization for DBT-detected suspicious abnormalities not visualized with other modalities and to analyze the imaging and pathologic characteristics of abnormalities detected only with DBT to determine the positive predictive value for malignancy. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board, and the requirement to obtain informed consent was waived. A retrospective query of the imaging database identified 34 consecutive women (average age, 55 years; age range, 28-84 years) with 36 lesions who underwent DBT-guided needle localization between April 2011 and January 2013 with use of commercially available equipment. Imaging findings and medical records were reviewed. Findings that were attributable to previous surgical changes were classified as benign or probably benign and excluded from analysis because the lesions did not proceed to localization. RESULTS: Architectural distortion was the imaging finding identified in all 36 abnormalities (100%). Findings from pathologic examination after the first attempt at localization were concordant with those from imaging in 35 of the 36 lesions (97%), which is suggestive of appropriate sampling. Histologic findings were malignant in 17 of the 36 lesions (47%; 95% confidence interval: 30.4%, 64.5%). Thirteen of the 17 lesions (76%; 95% confidence interval: 50.1%, 93.1%) were invasive malignancies. Twenty-two of the 36 abnormalities (61%) were either malignant or high-risk lesions (atypical ductal hyperplasia, lobular carcinoma in situ, atypical lobular hyperplasia). CONCLUSION: DBT-guided needle localization is an accurate and feasible method with which to biopsy DBT-detected suspicious architectural distortions not visualized at mammography or sonography. The high risk of malignancy in abnormalities detected only with DBT (47%) confirms that routine biopsy is required for histologic analysis.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mamografía/métodos , Intensificación de Imagen Radiográfica , Ultrasonografía Mamaria , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja , Neoplasias de la Mama/cirugía , Estudios de Factibilidad , Femenino , Humanos , Biopsia Guiada por Imagen , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cuidados Preoperatorios , Reproducibilidad de los Resultados , Estudios Retrospectivos
5.
Radiographics ; 35(2): 302-15, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25763718

RESUMEN

Mammographic breast density is rapidly becoming a hot topic in both the medical literature and the lay press. In the United States, recent legislative changes in 19 states now require radiologists to notify patients regarding breast density as well as the possible need for supplemental screening. Federal legislation regarding breast density notification has been introduced, and its passage is likely on the horizon. An understanding of the context, scientific evidence, and controversies surrounding the topic of breast density as a risk factor for breast cancer is critical for radiologists. The current state of evidence is presented regarding supplemental screening for women with dense breasts, including the use of digital breast tomosynthesis, whole-breast ultrasonography, and gadolinium-enhanced magnetic resonance imaging. A review of current practice guidelines and additional sources of information will improve radiologists' understanding of the relevant subject of breast density and enable them to respond appropriately to questions from patients, clinicians, and the media.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/patología , Detección Precoz del Cáncer , Mamografía , Neoplasias de la Mama/diagnóstico , Femenino , Humanos , Imagen por Resonancia Magnética , Mamografía/métodos , Guías de Práctica Clínica como Asunto , Reproducibilidad de los Resultados , Factores de Riesgo , Ultrasonografía Mamaria
7.
Breast Cancer Res Treat ; 145(2): 331-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24748568

RESUMEN

Radial scars (RS's) are benign breast lesions known to be associated with carcinomas and other high-risk lesions (HRL's). The upgrade rate to carcinoma after core biopsy revealing RS is 0-40 %. We sought to determine the outcomes of RS with and without HRL diagnosed by core biopsy. Patients who underwent core biopsy revealing RS without carcinoma at our institution between 1/1996 and 11/2012 were identified from a surgical pathology database. Retrospective chart review was utilized to classify patients as RS-no HRL or RS-HRL. HRL was defined as ADH, LCIS, and/or ALH. We determined upgrade rate to carcinoma at surgical excision, and upgrade to HRL for RS-no HRL patients. Univariate analysis was performed to identify risk factors for upgrade in RS-no HRL patients. 156 patients underwent core biopsy revealing RS, 131 RS-no HRL (84 %), and 25 RS-HRL (16 %). The overall rate of upgrade to invasive carcinoma was 0.8 % (1/124). 1.0 % (1/102) of RS-no HRL and 13.6 % (3/22) of RS-HRL patients were upgraded to DCIS (P = 0.0023). The upgrade of RS-no HRL to HRL at excision was 21.6 % (22/102). By univariate analysis, RS-no HRL with radiologic appearance of a mass/architectural distortion had a significantly higher rate of upgrade to HRL or carcinoma compared with calcifications (P = 0.03). Excision of RS to rule out associated invasive carcinoma is not warranted, given a <1 % rate of upgrade at excision. However, excision to evaluate for non-invasive cancer or HRL may be considered to help guide clinical decision-making about use of chemoprevention.


Asunto(s)
Biopsia con Aguja Gruesa , Neoplasias de la Mama/patología , Glándulas Mamarias Humanas/patología , Glándulas Mamarias Humanas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
8.
Radiology ; 270(1): 49-56, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24354377

RESUMEN

PURPOSE: To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. MATERIALS AND METHODS: In this HIPAA-compliant, institutional review board-approved study, 10 radiologists prospectively read images from screening digital mammography or screening combined tomosynthesis and mammography examinations for 1-hour-long uninterrupted sessions. Images from 3665 examinations (1502 combined and 2163 digital mammography) from July 2012 to January 2013 were interpreted in at least five sessions per radiologist per modality. The number of cases reported during each session was recorded for each reader. The experience level for each radiologist was also correlated to the average number of cases reported per hour. Analysis of variance was used to assess the number of studies interpreted per hour. A linear regression model was used to evaluate correlation between breast imaging experience and time taken to interpret images from both modalities. RESULTS: The mean number of studies interpreted in hour was 23.8 ± 0.55 (standard deviation) (range, 14.4-40.4) for combined tomosynthesis and mammography and 34.0 ± 0.55 (range, 20.4-54.3) for digital mammography alone. A mean of 10.2 fewer studies were interpreted per hour during combined tomosynthesis and mammography compared with digital mammography sessions (P < .0001). The mean interpretation time was 2.8 minutes ± 0.9 (range, 1.5-4.2 minutes) for combined tomosynthesis and mammography and 1.9 minutes ± 0.6 (range, 1.1-3.0) for digital mammography; interpretation time with combined tomosynthesis and mammography was 0.9 minute longer (47% longer) compared with digital mammography alone (P < .0001). With the increase in years of breast imaging experience, the overall additional time required to read images from combined tomosynthesis and mammography examinations decreased (R(2) = 0.52, P = .03). CONCLUSION: Addition of tomosynthesis to mammography results in increased time to interpret images from screening examinations compared with time to interpret images from conventional digital mammography alone.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Tomografía Computarizada por Rayos X/métodos , Competencia Clínica , Femenino , Humanos , Tamizaje Masivo/estadística & datos numéricos , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Factores de Tiempo
9.
Radiographics ; 34(2): 343-58, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24617683

RESUMEN

Digital breast tomosynthesis (DBT) is rapidly emerging as an important clinical tool for both screening and diagnosis. DBT improves upon mammography by depicting breast tissue on a dynamic sequence of cross-sectional images reconstructed in planes corresponding to their mammographic planes of acquisition. DBT results in markedly reduced summation of overlapping tissue and depicts the margins of masses in far greater detail than mammography. Fat is commonly recognized in both benign and malignant breast masses at DBT, even when no fat is appreciated at mammography. In cases of encapsulated fat-containing masses, the increased detail at DBT often allows the radiologist to definitively classify a mass as benign (eg, lipoma, hamartoma, galactocele, lipid cyst) when mammographic findings alone are equivocal, thereby avoiding unnecessary biopsy or workup. However, when learning to read DBT images, many radiologists misinterpret this rule, mistaking the presence of any fat within a mass for an indication of benignity or an artifact and falsely concluding that an otherwise suspicious mass is not worrisome. If fat seen in breast masses at DBT is not appropriately analyzed, malignant breast masses may be incorrectly classified as probably or even definitely benign. With use of radiologic-pathologic correlation, the authors illustrate cases in which the presence of fat can help correctly classify a mass as benign, and pitfalls in which the presence or absence of fat within a mass is irrelevant and should not influence analysis.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Intensificación de Imagen Radiográfica , Tomografía , Femenino , Humanos
10.
Radiographics ; 34(7): 1807-16, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25384280

RESUMEN

Methods of axillary evaluation in invasive breast cancer continue to evolve. The recent American College of Surgeons Oncology Group Z0011 Trial is a prospective, randomized, multicenter trial that compared the survival and locoregional recurrence rates after complete axillary lymph node dissection (ALND) versus sentinel node biopsy (SNB) alone in women with a positive sentinel node in an effort to avoid the complications associated with ALND. As the results of this trial are implemented clinically, affecting surgical management of axillary metastatic disease, radiologists may need to redefine their role in the preoperative assessment of the axilla. Before the Z0011 trial, breast imagers worked to identify axillary metastases preoperatively, allowing appropriate patients to proceed directly to ALND and avoiding the need for SNB. However, the Z0011 trial concluded that ALND may not be necessary in women with metastatic axillary disease who meet the trial criteria. In the Z0011 trial, after 6 years of median follow-up there was no difference in either locoregional recurrence or survival among the women who underwent SNB alone compared with those who underwent ALND, suggesting that ALND is unnecessary in a subset of women with a positive node at SNB. These results raise questions about how aggressively radiologists should pursue percutaneous sampling of axillary nodes, as some practitioners conclude that, in an otherwise eligible woman, positive results from imaging-guided percutaneous biopsy preclude a Z0011 trial-directed pathway. Debate about the best way to implement the results of the Z0011 trial into daily clinical practice exists. It is important for breast imagers to work closely with breast surgeons to provide the most appropriate treatment course for each patient.


Asunto(s)
Axila/patología , Neoplasias de la Mama/patología , Biopsia Guiada por Imagen , Biopsia del Ganglio Linfático Centinela , Femenino , Humanos , Metástasis Linfática , Invasividad Neoplásica
11.
J Am Coll Radiol ; 21(6S): S126-S143, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38823941

RESUMEN

Early detection of breast cancer from regular screening substantially reduces breast cancer mortality and morbidity. Multiple different imaging modalities may be used to screen for breast cancer. Screening recommendations differ based on an individual's risk of developing breast cancer. Numerous factors contribute to breast cancer risk, which is frequently divided into three major categories: average, intermediate, and high risk. For patients assigned female at birth with native breast tissue, mammography and digital breast tomosynthesis are the recommended method for breast cancer screening in all risk categories. In addition to the recommendation of mammography and digital breast tomosynthesis in high-risk patients, screening with breast MRI is recommended. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Asunto(s)
Neoplasias de la Mama , Detección Precoz del Cáncer , Medicina Basada en la Evidencia , Sociedades Médicas , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Detección Precoz del Cáncer/métodos , Estados Unidos , Mamografía/normas , Mamografía/métodos , Medición de Riesgo , Tamizaje Masivo/métodos
13.
Ann Surg Oncol ; 20(10): 3218-22, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23975296

RESUMEN

BACKGROUND: Eligibility for nipple-sparing mastectomy (NSM) varies widely on the basis of patient and tumor factors. METHODS: Review of patients undergoing NSM from June 2007 to December 2012 at our institution was performed. Patient and tumor characteristics, complications, and recurrences were collected. NSM from 2007 to 2010 and 2011 to 2012 were compared to assess trends in eligibility and outcomes over time. RESULTS: NSM was performed on 645 breasts in 370 patients. Indications were risk reduction in 330 (51.2 %), invasive cancer in 226 (35.0 %), and ductal carcinoma-in situ in 89 (13.8 %) breasts. Fifty-one (13.8 %) patients had positive lymph nodes. Twenty-seven (7.3 %) patients received neoadjuvant chemotherapy. Forty-eight (7.4 %) breasts had prior radiotherapy. Total nipple necrosis occurred in 11 (1.7 %) breasts. Twenty-four (3.7 %) breasts had nipples removed as a result of positive subareolar/nipple margins. At 22 months' mean follow-up, local recurrence occurred in 4 of 156 (2.6 %) breasts operated on for cancer through 2011. No recurrences involved the nipple. NSM performed in 2011-2012 (n = 475) compared to 2007-2010 (n = 170), were more often for cancer, in patients with higher body mass index, and on larger breasts (p < 0.001). There was no significant difference in total nipple necrosis rates between groups. Nipple loss due to positive subareolar/nipple margins was significantly less in 2011-2012 (p = 0.027). CONCLUSIONS: Eligibility for NSM has expanded to include women with higher body mass index and larger breasts, with no increase in nipple loss due to ischemia. Rates of positive subareolar margins have decreased over time, even though NSM is being performed more frequently for cancer, suggesting improved patient selection.


Asunto(s)
Neoplasias de la Mama/cirugía , Carcinoma Intraductal no Infiltrante/cirugía , Mastectomía , Recurrencia Local de Neoplasia/cirugía , Pezones/cirugía , Selección de Paciente , Adulto , Anciano , Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Femenino , Estudios de Seguimiento , Humanos , Mamoplastia , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Pezones/patología , Pronóstico , Estudios Prospectivos , Estudios Retrospectivos , Colgajos Quirúrgicos , Adulto Joven
14.
Healthcare (Basel) ; 10(11)2022 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-36421586

RESUMEN

Breast tumor segmentation is a critical task in computer-aided diagnosis (CAD) systems for breast cancer detection because accurate tumor size, shape, and location are important for further tumor quantification and classification. However, segmenting small tumors in ultrasound images is challenging due to the speckle noise, varying tumor shapes and sizes among patients, and the existence of tumor-like image regions. Recently, deep learning-based approaches have achieved great success in biomedical image analysis, but current state-of-the-art approaches achieve poor performance for segmenting small breast tumors. In this paper, we propose a novel deep neural network architecture, namely the Enhanced Small Tumor-Aware Network (ESTAN), to accurately and robustly segment breast tumors. The Enhanced Small Tumor-Aware Network introduces two encoders to extract and fuse image context information at different scales, and utilizes row-column-wise kernels to adapt to the breast anatomy. We compare ESTAN and nine state-of-the-art approaches using seven quantitative metrics on three public breast ultrasound datasets, i.e., BUSIS, Dataset B, and BUSI. The results demonstrate that the proposed approach achieves the best overall performance and outperforms all other approaches on small tumor segmentation. Specifically, the Dice similarity coefficient (DSC) of ESTAN on the three datasets is 0.92, 0.82, and 0.78, respectively; and the DSC of ESTAN on the three datasets of small tumors is 0.89, 0.80, and 0.81, respectively.

15.
J Breast Imaging ; 4(2): 209-221, 2022 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38422423

RESUMEN

Autologous fat grafting (AFG) is a technique that is increasingly utilized in breast cosmetic and reconstructive surgery. In this procedure, fat is aspirated by liposuction from one area of the body and injected into the breast. The procedure and process of AFG has evolved over the last few decades, leading to more widespread use, though there is no standard method. Autologous fat grafting is generally considered a safe procedure but may result in higher utilization of diagnostic imaging due to development of palpable lumps related to fat necrosis. Imaging findings depend on surgical technique but typically include bilateral, symmetric, retromammary oil cysts and scattered dystrophic and/or coarse calcifications when AFG is used for primary breast augmentation. More focal findings occur when AFG is used to improve specific areas of cosmetic deformity, scarring, or pain following breast cancer surgery. As with any cause of fat necrosis, imaging features tend to appear more benign over time, with development of rim calcifications associated with oil cysts and a shift in echogenicity of oil cyst contents on ultrasound towards anechoic in some cases. This article reviews the AFG procedure, uses, complications, and imaging findings.

17.
Radiol Clin North Am ; 59(1): 1-11, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33222992

RESUMEN

"Starting in Wuhan, China, followed quickly in the United States in January 2020, an outbreak of a novel coronavirus, or COVID-19, escalated to a global pandemic by March. Significant disruptions occurred to breast imaging, including deferred screening mammography, triaging diagnostic breast imaging, and changes in breast cancer care algorithms. This article summarizes the effect of the global pandemic-and efforts to curtail its spread-on both breast cancer care and on breast imaging practices including effects on patients, clinical workflow, education, and research."


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/epidemiología , COVID-19/epidemiología , COVID-19/prevención & control , Mamografía/métodos , Atención al Paciente/tendencias , SARS-CoV-2 , COVID-19/virología , Comorbilidad , Detección Precoz del Cáncer , Humanos , Triaje , Estados Unidos/epidemiología
18.
Radiographics ; 30(7): 1891-913, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21057126

RESUMEN

Although numerous studies have outlined the benefits of contrast material-enhanced magnetic resonance (MR) imaging for the detection of breast parenchymal findings, the assessment of lesions of the skin and superficial tissue at breast MR imaging has largely been overlooked. Such lesions, both benign and malignant, are commonly encountered at breast MR imaging, and their detection and diagnosis are often imperative. These lesions include superficial, locally extensive, inflammatory, and recurrent breast cancers; iatrogenic changes; sebaceous cysts; and less prevalent diseases such as granulomatous mastitis and angiosarcomas, among others. As MR imaging continues to be used with increasing frequency in both the screening and diagnostic settings, these lesions will be encountered more often; consequently, a better understanding of which lesions may be ignored and which require further evaluation will become increasingly important. Frequently, MR imaging alone may not clearly indicate the cause of lesions of the breast skin and superficial tissue. However, radiologists should thoroughly assess such lesions, taking into consideration the spectrum of possible causes. Mammography, ultrasonography, consultation with clinicians or dermatologists regarding physical examination findings, and, when necessary, correlation with pathologic findings in biopsy specimens may be used in conjunction with MR imaging to establish both the importance of these lesions and their definitive diagnoses.


Asunto(s)
Mama/patología , Imagen por Resonancia Magnética/métodos , Neoplasias Cutáneas/patología , Piel/patología , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad
19.
Ultrasound Med Biol ; 46(10): 2819-2833, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32709519

RESUMEN

Incorporating human domain knowledge for breast tumor diagnosis is challenging because shape, boundary, curvature, intensity or other common medical priors vary significantly across patients and cannot be employed. This work proposes a new approach to integrating visual saliency into a deep learning model for breast tumor segmentation in ultrasound images. Visual saliency refers to image maps containing regions that are more likely to attract radiologists' visual attention. The proposed approach introduces attention blocks into a U-Net architecture and learns feature representations that prioritize spatial regions with high saliency levels. The validation results indicate increased accuracy for tumor segmentation relative to models without salient attention layers. The approach achieved a Dice similarity coefficient (DSC) of 90.5% on a data set of 510 images. The salient attention model has the potential to enhance accuracy and robustness in processing medical images of other organs, by providing a means to incorporate task-specific knowledge into deep learning architectures.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Aprendizaje Profundo , Ultrasonografía Mamaria , Atención , Femenino , Humanos , Aumento de la Imagen , Modelos Teóricos , Ultrasonografía Mamaria/métodos
20.
Radiol Clin North Am ; 55(3): 503-512, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28411676

RESUMEN

Synthesized mammography (SM) is a new imaging technique similar to digital mammography constructed from an acquired digital breast tomosynthesis (DBT) examination. SM allows for widespread screening using DBT, maintaining the benefits of DBT while decreasing the radiation of DBT by nearly half. This article reviews studies evaluating SM, most of which suggest that SM may be appropriate to use clinically to replace an actual acquired conventional 2-dimensional full-field digital mammogram (FFDM) when using DBT for breast cancer screening. These results should be interpreted with caution because there are inherent differences between SM and FFDM image quality and lesion visibility and larger, more robust studies still need to be performed.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Mama/diagnóstico por imagen , Femenino , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA