Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Magn Reson Imaging ; 54(3): 763-774, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33825259

RESUMEN

BACKGROUND: For peripheral artery disease (PAD), MR angiography (MRA) is a well-established diagnostic modality providing morphologic and dynamic information comparable to digital subtraction angiography (DSA). However, relatively large amounts of contrast agents are necessary to achieve this. PURPOSE: To evaluate the diagnostic accuracy of time-resolved 4D MR-angiography with interleaved stochastic trajectories (TWIST-MRA) by using maximum intensity projections (MIPs) of dynamic images acquired with reduced doses of contrast agent. STUDY TYPE: Retrospective. POPULATION: Forty adult PAD patients yielding 1088 artery segments. FIELD STRENGTH/SEQUENCE: A 3.0 T, time-resolved 4D MR-angiography with TWIST-MRA and MIP of dynamic images. ASSESSMENT: DSA was available in 14 patients (256 artery segments) and used as reference standard. Three-segmental MIP reconstructions of TWIST-images after administration of 3 mL of gadolinium-based contrast agent (Gadoteridol/Prohance®, 0.5 M) per anatomical level (pelvis, thighs, and lower legs) yielded 256 artery segments for correlation between MRA and DSA. Three independent observers rated image quality (scale: 1 [nondiagnostic] to 4 [excellent]) and the degree of venous overlay (scale: 0 [none] to 2 [significant]) for all segments. Diagnostic accuracy for the detection of >50% stenosis and artery occlusion was calculated for all observers. STATISTICAL TESTS: Binary classification test (sensitivity, specificity, positive/negative predictive values, diagnostic accuracy). Intraclass correlation coefficients (ICCs), logistic regression analysis with comparison of areas under the receiver-operating-characteristics (ROC) curves (AUCs) with the DeLong method. Bland-Altman-comparison. RESULTS: High diagnostic performance was achieved for the detection of >50% stenosis (sensitivity 92.9% [84.3-99.9% (95%-CI)] and specificity 98.5% [95.7-99.8% (95%-CI)]) and artery occlusion (sensitivity 93.1% [77.2-99.2% (95%-CI)] and specificity 99.1% [96.9-99.9% (95%-CI)]). Inter-reader agreement was excellent with ICC values ranging from 0.95 to 1.0 for >50% artery stenosis and occlusion. Image quality was good to excellent for both readers (3.41 ± 0.72, 3.33 ± 0.65, and 3.38 ± 0.61 [mean ± SD]) with good correlation between observer ratings (ICC 0.71-0.81). No significant venous overlay was observed (0.06 ± 0.24, 0.23 ± 0.43 and 0.11 ± 0.45 [mean ± SD]). DATA CONCLUSION: MIPs of dynamic TWIST-MRA offer a promising diagnostic alternative necessitating only reduced amounts (50%) of gadolinium-based contrast agents for the entire runoff vasculature. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Extremidad Inferior , Angiografía por Resonancia Magnética , Adulto , Angiografía de Substracción Digital , Medios de Contraste , Humanos , Extremidad Inferior/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Arch Gynecol Obstet ; 302(5): 1075-1080, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32767070

RESUMEN

BACKGROUND: Internal herniation of small intestine in the lesser pelvis alongside iliac vasculature is a rare occurrence. Skeletonization of iliac vessels during pelvic lymph node dissection (LND), as part of surgical staging or treatment of patients with uterine, ovarian or urogenital cancer, is a strict prerequisite for orifice formation. CASE PRESENTATION: A 68-year-old woman presented at the emergency department with complaints of constipation for the last 3 days and acute-onset abdominal pain, nausea and vomiting since few hours. She had a history of laparoscopic hysterectomy, bilateral salpingo-oophorectomy and para-aortic and pelvic LND 7 years ago. A distended abdomen with diffuse tenderness on palpation was noted. A CT scan demonstrated bowel obstruction secondary to an incarcerated hernia underneath an elongated right external iliac artery. During an emergency exploratory laparotomy, the incarcerated bowel was reduced and the hernial orifice closed with a running suture. The patient had an uneventful postoperative period and was discharged on the fifth postoperative day. DISCUSSION: This rare internal hernia can manifest with non-specific symptoms of small bowel obstruction at any given point after index surgery, sometimes even after several years free of complaints. Contrast-enhanced computed tomography is the method of choice for fast and reliable diagnosis and helps in planning the necessary emergency laparotomy. CONCLUSION: This life-threatening complication adds to the current controversy of pelvic and para-aortic lymphadenectomy in patients with endometrial cancer. Primary closure of peritoneal defects should be considered to potentially prevent internal hernias, especially when elongated iliac vessels are present.


Asunto(s)
Dolor Abdominal/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Vena Ilíaca/diagnóstico por imagen , Hernia Interna/complicaciones , Obstrucción Intestinal/diagnóstico por imagen , Laparoscopía/efectos adversos , Laparotomía/métodos , Dolor Abdominal/etiología , Anciano , Femenino , Humanos , Histerectomía/efectos adversos , Obstrucción Intestinal/etiología , Laparoscopía/métodos , Laparotomía/efectos adversos , Escisión del Ganglio Linfático/efectos adversos , Náusea/etiología , Salpingooforectomía/efectos adversos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Vómitos/etiología
3.
Eur Heart J ; 35(43): 3021-32, 2014 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-24658767

RESUMEN

AIMS: Cardiovascular events remain the leading cause of death in Western world. Atherosclerosis is the most common underlying complication driven by low-density lipoproteins (LDL) disturbing vascular integrity. Carbamylation of lysine residues, occurring primarily in the presence of chronic kidney disease (CKD), may affect functional properties of lipoproteins; however, its effect on endothelial function is unknown. METHODS AND RESULTS: Low-density lipoprotein from healthy donors was isolated and carbamylated. Vascular reactivity after treatment with native LDL (nLDL) or carbamylated LDL (cLDL) was examined in organ chambers for isometric tension recording using aortic rings of wild-type or lectin-like-oxidized LDL receptor-1 (LOX-1) transgenic mice. Reactive oxygen species (ROS) and nitric oxide (NO) production were determined using electron spin resonance spectroscopy. The effect of LDL-carbamyl-lysine levels on cardiovascular outcomes was determined in patients with CKD during a median follow-up of 4.7 years. Carbamylated LDL impaired endothelium-dependent relaxation to acetylcholine or calcium-ionophore A23187, but not endothelium-independent relaxation to sodium nitroprusside. In contrast, nLDL had no effect. Carbamylated LDL enhanced aortic ROS production by activating NADPH-oxidase. Carbamylated LDL stimulated endothelial NO synthase (eNOS) uncoupling at least partially by promoting S-glutathionylation of eNOS. Carbamylated LDL-induced endothelial dysfunction was enhanced in LOX-1 transgenic mice. In patients with CKD, LDL-carbamyl-lysine levels were significant predictors for cardiovascular events and all-cause mortality. CONCLUSIONS: Carbamylation of LDL induces endothelial dysfunction via LOX-1 activation and increased ROS production leading to eNOS uncoupling. This indicates a novel mechanism in the pathogenesis of atherosclerotic disease which may be pathogenic and prognostic in patients with CKD and high plasma levels of cLDL.


Asunto(s)
Endotelio Vascular/fisiopatología , Lipoproteínas LDL/fisiología , Acetilcolina/farmacología , Análisis de Varianza , Animales , Aorta/fisiología , Enfermedades Cardiovasculares/fisiopatología , Inhibidores Enzimáticos/farmacología , Voluntarios Sanos , Humanos , Técnicas In Vitro , Lipoproteínas LDL/metabolismo , Lipoproteínas LDL/farmacología , Ratones Endogámicos C57BL , Ratones Transgénicos , Óxido Nítrico Sintasa de Tipo III/metabolismo , Compuestos Onio/farmacología , Especies Reactivas de Oxígeno/metabolismo , Insuficiencia Renal Crónica/metabolismo , Insuficiencia Renal Crónica/fisiopatología , Receptores Depuradores de Clase E/metabolismo , Vasodilatación/efectos de los fármacos , Vasodilatadores/farmacología
4.
Front Bioeng Biotechnol ; 12: 1370837, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38524192

RESUMEN

Introduction: The management of fractured bones is a key domain within orthopedic trauma surgery, with the prevention of delayed healing and non-unions forming a core challenge. This study evaluates the efficacy of the AO Fracture Monitor in conjunction with biomechanical simulations to better understand the local mechanics of fracture gaps, which is crucial for comprehending mechanotransduction, a key factor in bone healing. Through a series of experiments and corresponding simulations, the study tests four hypotheses to determine the relationship between physical measurements and the predictive power of biomechanical models. Methods: Employing the AO Fracture Monitor and Digital Image Correlation techniques, the study demonstrates a significant correlation between the surface strain of implants and interfragmentary movements. This provides a foundation for utilizing one-dimensional AO Fracture Monitor measurements to predict three-dimensional fracture behavior, thereby linking mechanical loading with fracture gap dynamics. Moreover, the research establishes that finite element simulations of bone-implant systems can be effectively validated using experimental data, underpinning the accuracy of simulations in replicating physical behaviors. Results and Discussion: The findings endorse the combined use of monitoring technologies and simulations to infer the local mechanical conditions at the fracture site, offering a potential leap in personalized therapy for bone healing. Clinically, this approach can enhance treatment outcomes by refining the assessment precision in trauma trials, fostering the early detection of healing disturbances, and guiding improvements in future implant design. Ultimately, this study paves the way for more sophisticated patient monitoring and tailored interventions, promising to elevate the standard of care in orthopedic trauma surgery.

5.
Eur Radiol Exp ; 7(1): 12, 2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-37009937

RESUMEN

BACKGROUND: We investigated the feasibility of aneurysm sac embolization using a novel self-expanding porous shape memory polymer (SMP) device during endovascular aortic abdominal or thoracic aneurysm repair (EVAR). METHODS: Retrospective analysis of consecutive patients treated at 2 centers in Germany. Patients were treated from January 2019 to July 2021 with follow-up at 7 days and 3, 6, and 12 months. Aneurysm sacs were implanted with SMP devices immediately following endograft placement during the same procedure. Primary endpoint was technically successful SMP-device deployment into the aneurysm sac outside the endograft. Secondary endpoints were changes in aneurysm volume and associated complications (e.g., endoleaks). RESULTS: We included 18 patients (16 males), aged 72 ± 9 years, achieving 100% technical success. Mean preprocedure aortic aneurysm sac volume was 195 ± 117 mL with a perfused aneurysm volume of 97 ± 60 mL. A mean of 24 ± 12 SMP devices per patient were used (range 5-45, corresponding to 6.25-56.25 mL expanded embolic material volume). All evaluable patients exhibited sac regression except 2 patients yet to reach 3-month follow-up. At mean 11 ± 7 months (range 3-24), change in aneurysm volume from baseline was -30 ± 21 mL (p < 0.001). In 8 patients, aneurysm regression was observed despite type 2 endoleaks in 6 and type 1A endoleaks in 2, none of them requiring further intervention to date. No morbidity or mortality related to this treatment occurred. CONCLUSIONS: SMP devices for aortic aneurysm sac embolization during endovascular repair appear feasible and safe in this small case series. Prospective studies are needed. KEY POINTS: • Shape memory polymer is a novel, self-expanding, porous, and radiolucent embolic device material. • Aortic aneurysm sacs were treated with polymer devices immediately following endograft placement. • Aortic aneurysm sac regression was observed in all patients with over 3-month follow-up. • Aortic aneurysm sac regression was observed even in the presence of endoleaks.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta , Implantación de Prótesis Vascular , Masculino , Humanos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Endofuga/diagnóstico por imagen , Endofuga/terapia , Endofuga/etiología , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Estudios de Factibilidad , Resultado del Tratamiento , Aneurisma de la Aorta/complicaciones
6.
Diagn Interv Radiol ; 28(4): 383-386, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35731712

RESUMEN

This study aimed to report on complication management in a 58-year-old woman referred for transjugular biopsy for the evaluation of unknown liver disease. After an initial uneventful biopsy procedure, the patient complained of severe upper abdominal pain. Laboratory tests revealed increasing liver enzymes. Imaging studies depicted an iatrogenic pseudoaneurysm associated with an arterio-biliary fistula originating from the right peripheral hepatic artery. Angiography and percutaneous transarterial superselective embolotherapy was performed by means of a microcatheter and microvascular plug. Precise device positioning allowed for successful closure of the bleeding site without compromising the hepatic vasculature.


Asunto(s)
Aneurisma Falso , Fístula Biliar , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Fístula Biliar/complicaciones , Biopsia , Femenino , Arteria Hepática/diagnóstico por imagen , Humanos , Enfermedad Iatrogénica , Hígado/diagnóstico por imagen , Persona de Mediana Edad
7.
Ann Anat ; 240: 151851, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34774666

RESUMEN

Different techniques are available for carpal tunnel release such as classical surgical operations or minimally invasive procedures. A minimally invasive approach and the relevant regional anatomy are reported in this pilot study which was conducted with bodies from a body donation program. The method described here uses a hook knife to cut through the transverse carpal ligament or flexor retinaculum under ultrasound guidance. The results are documented by means of magnetic resonance and ultrasound imaging as well as by anatomical dissection.


Asunto(s)
Síndrome del Túnel Carpiano , Síndrome del Túnel Carpiano/diagnóstico por imagen , Síndrome del Túnel Carpiano/cirugía , Humanos , Ligamentos Articulares , Proyectos Piloto , Radiografía , Ultrasonografía
8.
Rofo ; 194(1): 49-61, 2022 01.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-34352916

RESUMEN

PURPOSE: To analyze the quality of endovascular aortic aneurysm repair using the data of the DeGIR quality management system. Comparison of data between 2011 and 2019. MATERIALS AND METHODS: A retrospective analysis of all data registered in the DeGIR quality management system of the year 2019 was performed regarding the treatment quality for endovascular aortic aneurysm repair. Registration of data was voluntary. As quality parameters indication, treatment process data and quality of results were examined. The latter was judged by treatment success, complication rates and radiation exposure. RESULTS: Out of 189 590 data sets overall 1639 cases of EVAR were registered; compared to 2011 this was an increase of 472 cases. 5.9 % of these cases encompassed emergency treatments. The most frequent indication was an abdominal aneurysm with 72 % of cases. In 54 % of cases, the aortic diameter ranged 50-70 mm. The rates for technical success, over all complications and major complications were 92.8 %, 6.7 % and 6.0 % respectively for all EVAR including emergency indications. In general, EVAR yielded a mortality rate of 1.2 % while emergency procedures had a mortality rate of 7.3 %. Median dose area product and fluoroscopy time were 10 503 cGy × cm2 and 20 minutes respectively at a mean procedure time of 114 minutes. CONCLUSION: Data analysis of the DeGIR quality management system persistently showed a very high technical success rate for endovascular aortic aneurysm repair performed by interventional radiologists accompanied by a low complication rate. KEY POINTS: · The voluntary DeGIR quality assurance-system has reached high acceptance among interventional radiologists.. · The database has nearly 200 000 submissions on record for 2019.. · EVAR by interventional radiologists has shown very high technical success as well as a low complication rate.. CITATION FORMAT: · Frenzel F, Bücker A, Paprottka P et al. DeGIR Quality Report 2019: Report on the treatment quality of minimally invasive methods - Interventional therapy (EVAR) of abdominal aortic aneurysms. Fortschr Röntgenstr 2022; 194: 49 - 61.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Fluoroscopía , Humanos , Complicaciones Posoperatorias/diagnóstico por imagen , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
9.
Invest Radiol ; 57(4): 233-241, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-34743133

RESUMEN

OBJECTIVES: The aim of this study was to compare the diagnostic accuracy of apparent diffusion coefficient (ADC) ratios as a monoparametric magnetic resonance imaging (MRI) protocol for the detection of prostate cancer (PCa) with the established multiparametric (mp) MRI at 3.0 T. MATERIALS AND METHODS: According to power analysis, 52 male patients were included in this monocenter study with prospective data collection and retrospective, blinded multireader image analysis. The study was approved by the local ethics committee. Patients were recruited from January to December 2020. Based on mpMRI findings, patients underwent in-bore MR biopsy or prostatectomy for histopathologic correlation of suspicious lesions. Three readers, blinded to the histopathologic results and images of mpMRI, independently evaluated ADC maps for the detection of PCa. The ADC ratio was defined as the lowest signal intensity (SI) of lesions divided by the SI of normal tissue in the zone of origin. Predictive accuracy of multiparametric and monoparametric MRI were compared using logistic regression analysis. Moreover, both protocols were compared applying goodness-of-fit analysis with the Hosmer-Lemeshow test for continuous ADC ratios and Pearson χ2 test for binary decision calls, correlation analysis with Spearman ρ and intraclass correlation coefficients, as well as noninferiority assessment with a TOST ("two one-sided test"). RESULTS: Eighty-one histopathologically proven, unique PCa lesions (Gleason score [GS] ≥ 3 + 3) in 52 patients could be unequivocally correlated, with 57 clinically significant (cs) PCa lesions (GS ≥ 3 + 4). Multiparametric MRI detected 95%, and monoparametric ADC detected ratios 91% to 93% of csPCa. Noninferiority of monoparametric MRI was confirmed by TOST (P < 0.05 for all comparisons). Logistic regression analysis revealed comparable predictive diagnostic accuracy of ADC ratios (73.7%-87.8%) versus mpMRI (72.2%-84.7%). Spearman rank correlation coefficient for PCa aggressiveness revealed satisfactory correlation of ADC ratios (P < 0.013 for all correlations). The Hosmer-Lemeshow test for the logistic regression analysis for continuous ADC ratios indicated adequate predictive accuracy (P = 0.55-0.87), and the Pearson χ2 test showed satisfactory goodness of fit (P = 0.35-0.69, χ2 = 0.16-0.87). CONCLUSIONS: Normalized ADC ratios based on advanced DWI are noninferior to mpMRI at 3.0 T for the detection of csPCa in a preselected patient cohort and proved a fast and accurate assessment tool, thus showing a potential prospect of easing the development of future screening methods for PCa.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Recolección de Datos , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Imagen por Resonancia Magnética , Masculino , Clasificación del Tumor , Neoplasias de la Próstata/patología , Estudios Retrospectivos
10.
J Clin Med ; 10(4)2021 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-33671708

RESUMEN

BACKGROUND: This paper aimed to prospectively evaluate the safety of embolization therapy of pulmonary arteriovenous malformations (PAVMs) for the detection of cerebral infarctions by pre- and post-interventional MRI. Method One hundred and five patients (male/female = 44/61; mean age 48.6+/-15.8; range 5-86) with pre-diagnosed PAVMs on contrast-enhanced MRA underwent embolization therapy. The number of PAVMs treated in each patient ranged from 1-8 PAVMs. Depending on the size and localization of the feeding arteries, either Nester-Coils or Amplatzer vascular plugs were used for embolization therapy. cMRI was performed immediately before, and at the 4 h and 3-month post-embolization therapy. Detection of peri-interventional cerebral emboli was performed via T2w and DWI sequences using three different b-values, with calculation of ADC maps. Results Embolization did not show any post-/peri-interventional, newly developed ischemic lesions in the brain. Only one patient who underwent re-embolization and was previously treated with tungsten coils that corroded over time showed newly developed, small, diffuse emboli in the post-interventional DWI sequence. This patient already had several episodes of brain emboli before re-treatment due to the corroded coils, and during treatment, when passing the corroded coils, experienced additional small, clinically inconspicuous brain emboli. However, this complication was anticipated but accepted, since the vessel had to be occluded distally. Conclusion Catheter-based embolization of PAVMs is a safe method for treatment and does not result in clinically inconspicuous cerebral ischemia, which was not demonstrated previously.

11.
Ultrasound Med Biol ; 47(3): 488-498, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33358051

RESUMEN

The study described here systematically analyzed how specific artifacts in contrast-enhanced ultrasound (CEUS) can affect the detection of endoleaks during follow-up after endovascular aortic repair (EVAR). Patients undergoing EVAR of atherosclerotic or mycotic abdominal aortic aneurysms using various standard and branched stent-graft material for visceral and iliac preservation were enrolled over 5 y and followed up with computed tomography angiography (CTA) and CEUS simultaneously. CEUS artifacts were frequently identified after EVAR procedures (59% of examinations) and were caused mainly by contrast agent, different prosthesis or embolization material and postinterventional changes in the aneurysm sac. This article describes how to identify important artifacts and how to avoid false-negative or false-positive interpretations of endoleaks. Despite artifacts, CEUS had higher sensitivity for endoleak detection after EVAR than CTA. CEUS was superior to CTA in the identification of late endoleaks type II and in follow-up examinations after embolization procedures, where beam-hardening artifacts limited CTA.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Artefactos , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares , Ultrasonografía , Anciano , Anciano de 80 o más Años , Medios de Contraste , Endofuga/diagnóstico , Procedimientos Endovasculares/métodos , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
12.
J Cardiol ; 76(2): 211-216, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32402666

RESUMEN

BACKGROUND: This was a retrospective single-center evaluation for off-label use of a single Angio-Seal-VIP 8F vascular closure device (VCD) (Terumo Interventional Systems, Somerset, NJ, USA) for retrograde transfemoral arterial access exceeding 8F. METHODS: Between 2010 and 2018, in 32 consecutive patients (3 females; mean age 67±9; range 46-86 years) retrograde femoral access was performed in 48 groins for aortoiliac stent or stent graft implantations using 9-14F sheaths. For vascular closure, one single Angio-Seal™-VIP 8F was used. Procedural success, closure-related complications, and risk factors were retrospectively evaluated using patient characteristics, duplex-ultrasound, and contrast-enhanced computed tomography angiography (CTA). Receiver-operating-characteristics were used for statistical analysis. RESULTS: Technical success for deployment of VCD was 100%. Visual inspection and duplex-ultrasound confirmed immediate hemostasis in 100%. Postinterventional CTA depicted major vascular access site complications in 6.3% (3/48 groins) requiring surgical treatment. A subgroup of 13 patients underwent surgical cut-down one day after VCD deployment as part of a two-staged complex endovascular aortic aneurysm repair procedure, allowing for visual assessment of prior used undersized Angio-SealTM. Patient's height (p=0.028) and severe access site calcifications (p=0.028) proved as predictors for one vessel occlusion and two pseudoaneurysms. Low body-mass-index (BMI) showed a non-significant trend. Sheath-size, common femoral artery depth, or body weight were not indicative for occurrence of complications. CONCLUSIONS: In selected cases, without availability of appropriate VCDs, a single Angio-SealTM-VIP 8F served as a feasible option to achieve sufficient hemostasis of transfemoral access exceeding 8F without relevant bleeding complications. Very low BMI, tall body-height, and severe atherosclerosis were identified to predispose to access site complications.


Asunto(s)
Arteria Femoral/cirugía , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta/cirugía , Estatura , Índice de Masa Corporal , Procedimientos Endovasculares , Femenino , Técnicas Hemostáticas , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA