Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Endovasc Ther ; : 15266028221112259, 2022 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-35861466

RESUMEN

PURPOSE: Unintended false-lumen thoracic endovascular aortic repair (TEVAR) is under-reported and often fatal. We present percutaneous endovascular rescue techniques for true-lumen reperfusion with strategies to address the peripheral artery perfusion needs unique to each case. CASE REPORT: Two patients deteriorated 24 hours after uncomplicated and complicated acute aortic type-B dissection TEVAR treatment at a tertiary community hospital. Reevaluation of index and repeated imaging studies revealed inadvertent false-lumen TEVAR with severe visceral and peripheral ischemia. Stepwise subtraction angiography was used to confirm continuous true-lumen catheterization from femoral puncture into the thoracic aorta. Retrograde fenestration distal to the misplaced TEVAR from the true- into the false-lumen allowed for snorkeling by distal stent-extension across the dissection membrane. In one case, TEVAR stent graft extension resulted in true-lumen re-expansion and in the other case, bare-metal stent-extension for stabilization of the dissection membrane resulted in true-lumen re-expansion in addition to preservation of visceral and peripheral perfusion via the false-lumen. Despite excellent acute hemodynamic results and initial signs of recovery, both patients eventually died (multiorgan failure; cerebral hemorrhagic infarction). CONCLUSION: Correct indication and prompt recognition of potential inadvertent false-lumen stenting is critical to avoid disastrous sequelae, for example, malperfusion. Endovascular salvage is feasible for restoration of correct perfusion and must be performed in a timely manner. CLINICAL IMPACT: Clinically apparent, complicated type-B dissection necessitates instantaneous treatment. Prerequisite for an endovascular approach is a true-lumen guidewire continuously from access to the ascending aorta. DSA after TEVAR and prompt clinical re-evaluation are to verify effective visceral and peripheral restoration of blood flow. Despite these measures, inadvertent false-lumen TEVAR may occur rarely. Immediate recognition may allow for timely true-lumen re-expansion using percutaneous endovascular salvage techniques e.g. retrograde fenestration from the true- into the false-lumen for distal snorkeling of the misplaced TEVAR across the dissection membrane. However, morbidity and mortality are very high, if erroneous stent graft placement is not identified early.

2.
Q J Nucl Med Mol Imaging ; 66(3): 280-289, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31992688

RESUMEN

BACKGROUND: Accuracy of [68Ga]PSMA-11 PET/CT may be hampered by ureter accumulation, mimicking lymph node metastases depending on localization and configuration. The benefit of CT urography for differentiation of lymph node metastasis from urinary tract activity was evaluated in a "PET/CT with low-dose CT" setting. METHODS: Retrospective analysis of PET/CT for primary staging, biochemical recurrence or local treatment planning in patients with prostate cancer. For CT urography (CTU), iodinated contrast agent was administered 10 minutes prior to image acquisition. All potential pathologic (peri)ureteral tracer uptake was assigned to excretory ureteral accumulation or pathological lesion. To assess additional provided benefit of CTU all foci were rated with an introduced scoring system (ranging from 0 pts: CTU not needed; up to 3 pts: no differentiation possible without CTU). Success of ureter contrasting was assessed by measurement of Hounsfield units. Besides benefit for reading urography-enhanced PET/CT, the possible impact on subsequent patient treatment was evaluated. RESULTS: A number of N.=247 patients were included in this study. By CT urography, it was possible to identify each ureter on low-dose CT, with its major part contrasted. In 120/247 (48.6%) patients, urography increased the diagnostic confidence while providing substantial support for interpretation in 60 (24.3%) cases. In 42 (17.0%) patients, urography was clinically relevant (up-/downstaging) with potential impact on subsequent patient care. In 30 of these 42 cases (12.1% of all), discrepant treatment would have resulted from a misdiagnosed tracer accumulation without urography. CONCLUSIONS: CT urography benefits the interpretation of [68Ga]-PSMA-11 PET/CT with low-dose CT and leads to discrepant patient treatment in a small but significant subset of patients (12% in our cohort). The implementation of CT urography into standard protocols of [68Ga]PSMA-11 PET/CT with low-dose CT is recommended.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Radioisótopos de Galio , Humanos , Metástasis Linfática , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Urografía
3.
J Urol ; 206(1): 88-96, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33617326

RESUMEN

PURPOSE: Salvage lymph node dissection is a rescue treatment for patients with nodal recurrence after radical prostatectomy. Very limited data are available on robotic salvage lymph node dissection. Our purpose was to investigate perioperative and oncological outcomes of robotic salvage lymph node dissection in a large monocentric series. MATERIALS AND METHODS: Perioperative data, complications within 30 days after surgery and oncological outcomes as assessed by histology, prostate specific antigen changes, prostate specific antigen nadir after salvage lymph node dissection, and time to further therapy were analyzed. To identify predictive factors for oncological outcome, Kaplan-Meier and Cox-regression analyses were performed. For cases with a mismatch between preoperative positron emission tomography/computed tomography and the number of histologically positive lymph nodes, prostate specific membrane antigen immunohistochemistry was performed on removed lymph nodes. RESULTS: A total of 68 patients underwent robotic salvage lymph node dissection with a median operation time of 126 minutes, a blood loss of 50 ml, and a length of stay of 4 days. No major complications (>Clavien 3) occurred. Median followup was 12.1 months. Median time to further therapy was 12.4 months, 37% of patients experienced complete biochemical response (prostate specific antigen <0.2 ng/ml) and 11% reached an undetectable prostate specific antigen, which was maintained for >1 year in 3 cases. Lower preoperative prostate specific antigen, longer time between radical prostatectomy and salvage lymph node dissection, preoperative prostate specific membrane antigen positron emission tomography/computed tomography and complete biochemical response after salvage lymph node dissection were significant predictors of longer therapy-free survival (all p <0.005). Prostate specific membrane antigen immunohistochemistry revealed that prostate specific membrane antigen positron emission tomography/computed tomography tends to miss small lymph node metastases <5 mm. CONCLUSIONS: Robotic salvage lymph node dissection is a feasible approach with low perioperative morbidity and delays further systemic therapy in most patients. Prostate specific membrane antigen positron emission tomography/computed tomography detection is mostly limited to tumor foci >5 mm.


Asunto(s)
Escisión del Ganglio Linfático/métodos , Recurrencia Local de Neoplasia/cirugía , Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Procedimientos Quirúrgicos Robotizados , Terapia Recuperativa/métodos , Anciano , Anciano de 80 o más Años , Predicción , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento
4.
J Magn Reson Imaging ; 54(3): 763-774, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33825259

RESUMEN

BACKGROUND: For peripheral artery disease (PAD), MR angiography (MRA) is a well-established diagnostic modality providing morphologic and dynamic information comparable to digital subtraction angiography (DSA). However, relatively large amounts of contrast agents are necessary to achieve this. PURPOSE: To evaluate the diagnostic accuracy of time-resolved 4D MR-angiography with interleaved stochastic trajectories (TWIST-MRA) by using maximum intensity projections (MIPs) of dynamic images acquired with reduced doses of contrast agent. STUDY TYPE: Retrospective. POPULATION: Forty adult PAD patients yielding 1088 artery segments. FIELD STRENGTH/SEQUENCE: A 3.0 T, time-resolved 4D MR-angiography with TWIST-MRA and MIP of dynamic images. ASSESSMENT: DSA was available in 14 patients (256 artery segments) and used as reference standard. Three-segmental MIP reconstructions of TWIST-images after administration of 3 mL of gadolinium-based contrast agent (Gadoteridol/Prohance®, 0.5 M) per anatomical level (pelvis, thighs, and lower legs) yielded 256 artery segments for correlation between MRA and DSA. Three independent observers rated image quality (scale: 1 [nondiagnostic] to 4 [excellent]) and the degree of venous overlay (scale: 0 [none] to 2 [significant]) for all segments. Diagnostic accuracy for the detection of >50% stenosis and artery occlusion was calculated for all observers. STATISTICAL TESTS: Binary classification test (sensitivity, specificity, positive/negative predictive values, diagnostic accuracy). Intraclass correlation coefficients (ICCs), logistic regression analysis with comparison of areas under the receiver-operating-characteristics (ROC) curves (AUCs) with the DeLong method. Bland-Altman-comparison. RESULTS: High diagnostic performance was achieved for the detection of >50% stenosis (sensitivity 92.9% [84.3-99.9% (95%-CI)] and specificity 98.5% [95.7-99.8% (95%-CI)]) and artery occlusion (sensitivity 93.1% [77.2-99.2% (95%-CI)] and specificity 99.1% [96.9-99.9% (95%-CI)]). Inter-reader agreement was excellent with ICC values ranging from 0.95 to 1.0 for >50% artery stenosis and occlusion. Image quality was good to excellent for both readers (3.41 ± 0.72, 3.33 ± 0.65, and 3.38 ± 0.61 [mean ± SD]) with good correlation between observer ratings (ICC 0.71-0.81). No significant venous overlay was observed (0.06 ± 0.24, 0.23 ± 0.43 and 0.11 ± 0.45 [mean ± SD]). DATA CONCLUSION: MIPs of dynamic TWIST-MRA offer a promising diagnostic alternative necessitating only reduced amounts (50%) of gadolinium-based contrast agents for the entire runoff vasculature. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Extremidad Inferior , Angiografía por Resonancia Magnética , Adulto , Angiografía de Substracción Digital , Medios de Contraste , Humanos , Extremidad Inferior/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
5.
Pediatr Radiol ; 50(8): 1078-1082, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32415324

RESUMEN

BACKGROUND: One main challenge in pediatric imaging is to reduce motion artifacts by calming young patients. To that end, the Radiological Society of North America (RSNA) as early as 1997 stated the necessity of adults accompanying their child during the child's examination. Nonetheless, current research lacks data regarding radiation dose to these chaperones. OBJECTIVE: The aim of this study was to measure the radiation dose of accompanying adults during state-of-the-art pediatric CT protocols. MATERIALS AND METHODS: In addition to a 100-kV non-contrast-enhanced chest CT (Protocol 1), we performed a 70-kV contrast-enhanced chest protocol (Protocol 2) using a third-generation dual-source CT. We acquired data on the radiation dose around the scanner using digital dosimetry placed right at the gantry, 1 m away, as well as beside the gantry. We acquired the CT-surrounding radiation dose during scanning of a pediatric phantom as well as 12 pediatric patients. RESULTS: After conducting 10 consecutive phantom scans using Protocol 1, we found the location with the highest cumulative dose acquired was right next to the gantry opening, at 3 µSv. Protocol 2 showed highest cumulative dose of 2 µSv at the same location. For Protocol 1, the location with the highest radiation doses during pediatric scans was right next to the gantry opening, with doses of 0.75±0.70 µSv. For Protocol 2, the highest radiation was measured 1 m away at 0.50±0.60 µSv. No radiation dose was measured at any time beside the gantry. CONCLUSION: Our results provide proof that chaperones receive low radiation doses during state-of-the-art CT examinations. Given knowledge of these values as well as the optimal spots with the lowest radiation doses, parents as well as patients might be more relaxed during the examination.


Asunto(s)
Chaperones Médicos , Dosis de Radiación , Tomografía Computarizada por Rayos X , Adulto , Niño , Medios de Contraste , Femenino , Humanos , Masculino , Fantasmas de Imagen , Monitoreo de Radiación
6.
Arch Gynecol Obstet ; 302(5): 1075-1080, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32767070

RESUMEN

BACKGROUND: Internal herniation of small intestine in the lesser pelvis alongside iliac vasculature is a rare occurrence. Skeletonization of iliac vessels during pelvic lymph node dissection (LND), as part of surgical staging or treatment of patients with uterine, ovarian or urogenital cancer, is a strict prerequisite for orifice formation. CASE PRESENTATION: A 68-year-old woman presented at the emergency department with complaints of constipation for the last 3 days and acute-onset abdominal pain, nausea and vomiting since few hours. She had a history of laparoscopic hysterectomy, bilateral salpingo-oophorectomy and para-aortic and pelvic LND 7 years ago. A distended abdomen with diffuse tenderness on palpation was noted. A CT scan demonstrated bowel obstruction secondary to an incarcerated hernia underneath an elongated right external iliac artery. During an emergency exploratory laparotomy, the incarcerated bowel was reduced and the hernial orifice closed with a running suture. The patient had an uneventful postoperative period and was discharged on the fifth postoperative day. DISCUSSION: This rare internal hernia can manifest with non-specific symptoms of small bowel obstruction at any given point after index surgery, sometimes even after several years free of complaints. Contrast-enhanced computed tomography is the method of choice for fast and reliable diagnosis and helps in planning the necessary emergency laparotomy. CONCLUSION: This life-threatening complication adds to the current controversy of pelvic and para-aortic lymphadenectomy in patients with endometrial cancer. Primary closure of peritoneal defects should be considered to potentially prevent internal hernias, especially when elongated iliac vessels are present.


Asunto(s)
Dolor Abdominal/diagnóstico por imagen , Arteria Ilíaca/diagnóstico por imagen , Vena Ilíaca/diagnóstico por imagen , Hernia Interna/complicaciones , Obstrucción Intestinal/diagnóstico por imagen , Laparoscopía/efectos adversos , Laparotomía/métodos , Dolor Abdominal/etiología , Anciano , Femenino , Humanos , Histerectomía/efectos adversos , Obstrucción Intestinal/etiología , Laparoscopía/métodos , Laparotomía/efectos adversos , Escisión del Ganglio Linfático/efectos adversos , Náusea/etiología , Salpingooforectomía/efectos adversos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Vómitos/etiología
7.
Eur Radiol ; 29(9): 5007-5012, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30796569

RESUMEN

OBJECTIVES: To evaluate technical feasibility and safety of endovascular tumor specimen sampling using an escalating endovascular biopsy strategy using a directional atherectomy device compared with forceps biopsy and catheter aspiration. MATERIALS AND METHODS: Between 2013 and 2017, a cohort of ten consecutive patients (6 male; median age 56, range 39-73 years) was referred for sampling of endovascular masses. Localizations included the abdominal aorta (n = 4), left brachiocephalic vein (n = 2), inferior vena cava (n = 1), and left pulmonary artery (n = 3). For each individual mass, all three endovascular tissue sampling approaches were applied including catheter-based aspiration, straight two-jaw biopsy forceps, and directional atherectomy during a single session. RESULTS: Aspiration and forceps biopsy did not provide sufficient material for histological analyses. In contrast, technical success for endovascular tumor sampling using directional atherectomy was 100%. After two atherectomy passages, sufficient material was available for each vessel region allowing histologic diagnosis, which revealed sarcoma and chronic inflammation for masses in the aorta, angiosarcoma for brachiocephalic vein, hepatocellular carcinoma for inferior vena cava, and angiosarcoma for pulmonary artery. In case of a histologically benign diagnosis, no malignant tumor proliferation was obvious on follow-up imaging studies after 3 months and 1 year. Thus, the rate of false-negative results was considered 0%. No procedure-associated complications, e.g., vessel perforation, were recorded. CONCLUSION: Preliminary results in a limited number of patients proved directional atherectomy beneficial as a safe and feasible technique for endoluminal tissue sampling of vascular masses. Additional large-scale studies are necessary and worthy for further evaluation in clinical practice. KEY POINTS: • Endovascular masses pose a challenge to appropriate clinical management. • Off-label directional atherectomy proved to be a safe and feasible technique for endoluminal tissue sampling of vascular masses. Furthermore, directional atherectomy was superior to aspiration or forceps biopsy in our small study cohort. • Directional atherectomy may represent the last or only option for tissue probing as a prerequisite for further treatment decisions.


Asunto(s)
Aterectomía/métodos , Biopsia/métodos , Neoplasias Vasculares/patología , Adulto , Anciano , Aterectomía/instrumentación , Biopsia/instrumentación , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
8.
Magn Reson Med ; 79(2): 1052-1060, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28497643

RESUMEN

PURPOSE: To investigate the potential of 3D ultrashort echo time MRI and short T2 images generated by subtraction for determination of total tumor burden in lung cancer. METHODS: As an animal model of spontaneously developing non-small cell lung cancer, the K-rasLA1 transgenic mouse was used. Three-dimensional MR imaging was performed with radial k-space acquisition and echo times of 20 µs and 1 ms. For investigation of the short T2 component in the recorded signal, subtraction images were generated from these data sets and used for consensus identification of tumors. Next, manual segmentation was performed on all MR images by two independent investigators. MRI data were compared with the results from histologic investigations and among the investigators. RESULTS: Tumor number and total tumor burden from imaging experiments correlated strongly with the results of histologic investigations. Intra- and interuser comparison showed highest correlations between the individual measurements for ultra-short TE MRI. CONCLUSIONS: Three-dimensional MRI protocols facilitate accurate tumor identification in mice harboring lung tumors. Ultrashort TE MRI is the superior imaging strategy when investigating lung tumors of miscellaneous size with 3D MR imaging strategies. Magn Reson Med 79:1052-1060, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Animales , Femenino , Ratones , Ratones Transgénicos , Neoplasias Experimentales/diagnóstico por imagen , Técnica de Sustracción , Carga Tumoral
9.
Urol Int ; 100(2): 245-247, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-26863421

RESUMEN

The horseshoe kidney is one of the most common congenital disorders affecting the urogenital system. Following a fusion of the lower kidney poles, which in turn lead to the formation of an isthmus, this anatomical variation is accompanied by other characteristic properties like an incomplete ascension, ventral rotation of the pelvices as well as atypical vascular supply. Even though renal carcinoids and Wilms tumors are more common in horseshoe kidneys, the incidence of renal cell carcinomas seems to be unaffected. Here we report the case of a locally advanced renal cell carcinoma with extensive venous invasion occurring in a horseshoe kidney and its complex surgical management. The whole primary tumor as well as a majority of venous tumor thrombi could be removed by a combination of 2/3 nephrectomy and cavotomy with thrombectomy. During 1 year of follow-up, the patient neither suffered from a tumor relapse, nor did he require renal replacement therapy. Thus, we conclude that even in cases of RCC where advanced disease is associated with complex anatomical situations, organ-preserving surgical treatment should be pursued to achieve excellent functional and oncological results.


Asunto(s)
Carcinoma de Células Renales/cirugía , Riñón Fusionado/cirugía , Neoplasias Renales/cirugía , Nefrectomía , Tratamientos Conservadores del Órgano , Venas Renales/cirugía , Trombectomía , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Riñón Fusionado/diagnóstico por imagen , Riñón Fusionado/patología , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Venas Renales/patología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Carga Tumoral
10.
J Transl Med ; 14(1): 167, 2016 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-27277003

RESUMEN

BACKGROUND: Apolipoprotein E-deficient (ApoE(-/-)) rodents spontaneously develop severe hypercholesterolemia and increased aortic stiffness, both accepted risk factors for cardiovascular morbidity and mortality in humans. In patients with resistant hypertension renal denervation (RDN) may improve arterial stiffness, however the underlying mechanisms are incompletely understood. This study investigates the impact of RDN on aortic compliance in a novel atherosclerosis prone ApoE(-/-)-rat model. METHODS: Normotensive, 8 weeks old ApoE(-/-) and Sprague-Dawley (SD) rats were subjected to bilateral surgical RDN (n = 6 per group) or sham operation (n = 5 per group) and fed with normal chow for 8 weeks. Compliance of the ascending aorta was assessed by magnetic resonance imaging. Vasomotor function was measured by aortic ring tension recordings. Aortic collagen content was quantified histologically and plasma aldosterone levels were measured by enzyme-linked immunosorbent assay (ELISA). RESULTS: After 8 weeks, ApoE(-/-)-sham demonstrated a 58 % decrease in aortic distensibility when compared with SD-sham (0.0051 ± 0.0011 vs. 0.0126 ± 0.0023 1/mmHg; p = 0.02). This was accompanied by an impaired endothelium-dependent relaxation of aortic rings and an increase in aortic medial fibrosis (17.87 ± 1.4 vs. 12.27 ± 1.1 %; p = 0.006). In ApoE(-/-)-rats, RDN prevented the reduction of aortic distensibility (0.0128 ± 0.002 vs. 0.0051 ± 0.0011 1/mmHg; p = 0.01), attenuated endothelial dysfunction, and decreased aortic medial collagen content (12.71 ± 1.3 vs. 17.87 ± 1.4 %; p = 0.01) as well as plasma aldosterone levels (136.33 ± 6.6 vs. 75.52 ± 8.4 pg/ml; p = 0.0003). Cardiac function and metabolic parameters such as hypercholesterolemia were not influenced by RDN. CONCLUSION: ApoE(-/-)-rats spontaneously develop impaired vascular compliance. RDN improves aortic distensibility and attenuated endothelial dysfunction in ApoE(-/-)-rats. This was associated with a reduction in aortic fibrosis formation, and plasma aldosterone levels.


Asunto(s)
Aorta/fisiopatología , Apolipoproteínas E/deficiencia , Aterosclerosis/fisiopatología , Desnervación , Riñón/inervación , Sistema Nervioso Simpático/fisiopatología , Animales , Aorta/efectos de los fármacos , Aorta/patología , Apolipoproteínas E/metabolismo , Aterosclerosis/patología , Presión Sanguínea/efectos de los fármacos , Peso Corporal/efectos de los fármacos , Carbacol/farmacología , Progresión de la Enfermedad , Endotelio Vascular/fisiopatología , Fibrosis , Pruebas de Función Cardíaca , Técnicas In Vitro , Inflamación/patología , Riñón/fisiopatología , Nitroglicerina/farmacología , Norepinefrina/metabolismo , Ratas Sprague-Dawley , Sistema Renina-Angiotensina/efectos de los fármacos , Sistema Nervioso Simpático/efectos de los fármacos , Sistema Nervioso Simpático/patología , Vasodilatación/efectos de los fármacos
11.
AJR Am J Roentgenol ; 206(3): 481-6, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26901004

RESUMEN

OBJECTIVE: The purpose of this study was to prospectively compare the effect of inspiration and resting expiratory position on contrast enhancement in pulmonary CT angiography (CTA) in a randomized clinical trial. SUBJECTS AND METHODS: In accordance with a power analysis performed before the study, we included 28 consecutive patients referred for evaluation of suspected pulmonary embolism in this prospective study. Patients were randomly assigned to perform either inspiration (n = 14; six men, eight women; mean age [SD], 38.1 ± 9.8 years) or resting expiratory position (n = 14; six men, eight women; mean age: 42.1 ± 9.2 years). All patients were scanned in a standardized supine position and scanning parameters were kept constant. Contrast medium was injected automatically with bolus tracking. Objective pulmonary vessel attenuation was quantified with digital measurement. Results were analyzed by using the unpaired t test and chi-square test. RESULTS: Patients in the resting expiratory position showed significantly higher contrast attenuation than those who performed inspiration (302.9 ± 11.9 HU vs 221.5 ± 20.9 HU; p < 0.01). There were no significant differences in applied total volume of contrast agent (76.8 ± 1.9 mL vs 75.7 ± 1.6 mL; p = 0.6765), total volume including normal saline bolus (116.8 mL ± 2.8 mL vs 121.8 mL ± 2.3 mL; p = 0.1724) or flow rate (3.1 mL/s ± 0.1 mL/s vs 3.2 mL/s ± 0.1 mL/s). CONCLUSION: Pulmonary CTA should be performed in the resting expiratory position, and patients should be instructed to avoid inspiration to achieve the highest possible attenuation in the pulmonary arteries.


Asunto(s)
Angiografía , Pulmón/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Medios de Contraste , Espiración , Femenino , Humanos , Inhalación , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Pulmonar/fisiopatología , Embolia Pulmonar/fisiopatología
13.
J Endovasc Ther ; 22(1): 74-9, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25775684

RESUMEN

PURPOSE: To report a retrospective observational analysis of standard balloon angioplasty (BA) vs. paclitaxel-coated balloon angioplasty (PCBA) for symptomatic central vein restenoses in patients with impaired native hemodialysis fistulas. METHODS: A retrospective review was conducted of 27 consecutive patients (15 men; mean age 66 ± 13.8 years, range 39-90) with 32 central vein stenoses (CVS; 6 axillary, 11 subclavian, 12 brachiocephalic, and/or 3 superior caval veins) treated successfully using BA. Freedom from reintervention after BA of de novo lesions was 7.4 ± 7.9 months (range 1-24). Twenty-five (92.6%) patients developed symptomatic restenoses and were treated one or more times by BA (n = 32) or PCBA (n = 20) using custom-made paclitaxel-coated balloons (diameter 6-14 mm). RESULTS: Technical (< 30% residual stenosis) and clinical (functional fistula) success rates for the initial and secondary angioplasty procedures were 100%. No minor/major procedure-associated complications occurred. Mean follow-up was 18.4 ± 17.5 months. Kaplan-Meier analysis for freedom from target lesion revascularization (TLR) found PCBA superior to BA (p = 0.029). Median freedom from TLR after BA was 5 months; after PCBA, > 50% of patients were event-free during the observation period (mean freedom from TLR 10 months). Restenosis intervals were prolonged by PCBA (median 9 months) vs. BA (median 4 months; p = 0.023). CONCLUSION: Paclitaxel-coated balloon angioplasty of central vein restenosis in patients with hemodialysis shunts yields a statistically significant longer freedom from TLR compared to standard balloon angioplasty.


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica/efectos adversos , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Diálisis Renal/efectos adversos , Trombosis Venosa Profunda de la Extremidad Superior/etiología , Trombosis Venosa Profunda de la Extremidad Superior/terapia , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/métodos , Angioplastia de Balón/mortalidad , Fármacos Cardiovasculares/administración & dosificación , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Trombosis Venosa Profunda de la Extremidad Superior/diagnóstico , Trombosis Venosa Profunda de la Extremidad Superior/mortalidad
14.
Eur Heart J ; 35(33): 2224-31b, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-24603307

RESUMEN

AIMS: Sympathetic stimulation induces left ventricular hypertrophy and is associated with increased cardiovascular risk. Catheter-based renal denervation (RDN) has been shown to reduce sympathetic outflow and blood pressure (BP). The present multi-centre study aimed to investigate the effect of RDN on anatomic and functional myocardial parameters, assessed by cardiac magnetic resonance (CMR), in patients with resistant hypertension. METHODS AND RESULTS: Cardiac magnetic resonance was performed in 72 patients (mean age 66 ± 10 years) with resistant hypertension (55 patients underwent RDN, 17 served as controls) at baseline and after 6 months. Clinical data and CMR results were analysed blindly. Renal denervation significantly reduced systolic and diastolic BP by 22/8 mm Hg and left ventricular mass index (LVMI) by 7.1% (46.3 ± 13.6 g/m(1.7) vs. 43.0 ± 12.6 g/m(1.7), P < 0.001) without changes in the control group (41.9 ± 10.8 g/m(1.7) vs. 42.0 ± 9.7 g/m(1.7), P = 0.653). Ejection fraction (LVEF) in patients with impaired LVEF at baseline (<50%) significantly increased after RDN (43% vs. 50%, P < 0.001). Left ventricular circumferential strain as a surrogate of diastolic function in the subgroup of patients with reduced strain at baseline increased by 21% only in the RDN group (-14.8 vs. -17.9; P = 0.001) and not in control patients (-15.5 vs. -16.4, P = 0.508). CONCLUSIONS: Catheter-based RDN significantly reduced BP and LVMI and improved EF and circumferential strain in patients with resistant hypertension, occurring partly BP independently.


Asunto(s)
Hipertensión/cirugía , Simpatectomía/métodos , Anciano , Análisis de Varianza , Antihipertensivos/uso terapéutico , Presión Sanguínea/fisiología , Ablación por Catéter , Resistencia a Medicamentos , Femenino , Atrios Cardíacos , Humanos , Hipertensión/tratamiento farmacológico , Hipertensión/fisiopatología , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/fisiopatología , Angiografía por Resonancia Magnética , Masculino , Estrés Fisiológico/fisiología , Función Ventricular Izquierda/fisiología
15.
Radiol Med ; 120(12): 1100-11, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26088468

RESUMEN

OBJECTIVE: To evaluate low-dose gadobenate dimeglumine-enhanced MRI for the differential diagnosis of malignant renal tumors. METHODS: Sixty-two consecutive patients with unclear diagnosis at MDCT/ultrasound underwent dynamic CE-MRI of the kidneys with 0.05 mmol/kg gadobenate dimeglumine. Retrospective image evaluation was performed by two blinded readers. Lesion diagnosis at CE-MRI was correlated with findings from histology following tumor resection or from imaging follow-up after at least 1 year. Assessments were performed of diagnostic quality and level of diagnostic information. RESULTS: Thirty-nine (63 %) patients were correctly diagnosed with malignant lesions (36 with RCC, 2 with renal metastases, 1 with lymphoma) while 14 (22.6 %) patients were correctly diagnosed with benign (n = 12) or no (n = 2) lesions. Eight patients were considered false positive (5 with oncocytoma, 3 with atypical AML) and 1 patient false negative (atypical RCC). The sensitivity, specificity, accuracy, PPV, and NPV for the diagnosis of malignant renal lesions were 97.5 % (39/40), 63.6 % (14/22), 85.5 % (53/62), 83.0 % (39/47), and 93.3 % (14/15), respectively. Images were excellent in 60 and good in 2 patients. Minimal artifacts that did not compromise diagnosis were noted in 4/62 patients. CONCLUSION: Low-dose gadobenate dimeglumine-enhanced MRI is effective for the differential diagnosis of malignant renal tumors.


Asunto(s)
Medios de Contraste/administración & dosificación , Neoplasias Renales/diagnóstico , Riñón/patología , Imagen por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos/administración & dosificación , Adolescente , Adulto , Anciano , Artefactos , Carcinoma de Células Renales/diagnóstico , Carcinoma de Células Renales/patología , Niño , Diagnóstico Diferencial , Reacciones Falso Negativas , Reacciones Falso Positivas , Femenino , Humanos , Neoplasias Renales/secundario , Linfoma/diagnóstico , Masculino , Meglumina/administración & dosificación , Persona de Mediana Edad
16.
Eur Heart J ; 34(36): 2839-49, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22833515

RESUMEN

AIMS: In diabetes mellitus, heart failure with preserved ejection fraction (HFPEF) is a significant comorbidity. No therapy is available that improves cardiovascular outcomes. The aim of this study was to characterize myocardial function and ventricular-arterial coupling in a mouse model of diabetes and to analyse the effect of selective heart rate (HR) reduction by If-inhibition in this HFPEF-model. METHODS AND RESULTS: Control mice, diabetic mice (db/db), and db/db mice treated for 4 weeks with the If-inhibitor ivabradine (db/db-Iva) were compared. Aortic distensibility was measured by magnetic resonance imaging. Left ventricular (LV) pressure-volume analysis was performed in isolated working hearts, with biochemical and histological characterization of the cardiac and aortic phenotype. In db/db aortic stiffness and fibrosis were significantly enhanced compared with controls and were prevented by HR reduction in db/db-Iva. Left ventricular end-systolic elastance (Ees) was increased in db/db compared with controls (6.0 ± 1.3 vs. 3.4 ± 1.2 mmHg/µL, P < 0.01), whereas other contractility markers were reduced. Heart rate reduction in db/db-Iva lowered Ees (4.0 ± 1.1 mmHg/µL, P < 0.01), and improved the other contractility parameters. In db/db active relaxation was prolonged and end-diastolic capacitance was lower compared with controls (28 ± 3 vs. 48 ± 8 µL, P < 0.01). These parameters were ameliorated by HR reduction. Neither myocardial fibrosis nor hypertrophy were detected in db/db, whereas titin N2B expression was increased and phosphorylation of phospholamban was reduced both being prevented by HR reduction in db/db-Iva. CONCLUSION: In db/db, a model of HFPEF, selective HR reduction by If-inhibition improved vascular stiffness, LV contractility, and diastolic function. Therefore, If-inhibition might be a therapeutic concept for HFPEF, if confirmed in humans.


Asunto(s)
Antiarrítmicos/farmacología , Benzazepinas/farmacología , Insuficiencia Cardíaca/tratamiento farmacológico , Frecuencia Cardíaca/efectos de los fármacos , Animales , Aorta/metabolismo , Glucemia/metabolismo , Colágeno/metabolismo , Diástole , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/efectos de los fármacos , Insulina/metabolismo , Ivabradina , Angiografía por Resonancia Magnética , Masculino , Ratones , Ratones Endogámicos C57BL , Proteínas Quinasas/metabolismo , ARN Mensajero/metabolismo , Volumen Sistólico/fisiología , Sístole , Rigidez Vascular/efectos de los fármacos , Disfunción Ventricular Izquierda/tratamiento farmacológico , Disfunción Ventricular Izquierda/fisiopatología
17.
Artículo en Inglés | MEDLINE | ID: mdl-38419579

RESUMEN

OBJECTIVES: In patients with aortic root aneurysm, the aortic basal ring is frequently dilated. It has been speculated that the muscular part of the basal ring dilates most. The purpose of this study was to analyse the segmental dilatation of the basal ring, comparing normal and dilated roots in patients with tricuspid aortic valves. METHODS: Retrospective analysis of computed tomography studies in patients with normal and dilated aortic roots was performed. Lengths of segments of the basal ring corresponding to each of the 3 sinuses, and to the muscular and fibrous parts were measured. Fractions of these segments relative to the total basal ring perimeter were calculated. RESULTS: We analysed 152 normal and 126 dilated aortic roots and 86 propensity-matched pairs. Basal ring dilatation was present in all segments of dilated aortic roots with subtle differences between the segments corresponding to the 3 sinuses. The muscular part of the basal ring dilated proportionately to its fibrous part, with no difference in fractions of measured muscular part in normal and dilated roots [42.2% (interquartile range 4.3%) vs 42.1% (interquartile range 6.3%)]. CONCLUSIONS: Basal ring dilatation was present in all segments corresponding to the 3 sinuses in dilated aortic roots. Both muscular and fibrous parts dilated equally, supporting the need to stabilize the entire basal ring when performing aortic valve repair surgery.

18.
Int J Cardiovasc Imaging ; 40(3): 569-577, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38143250

RESUMEN

Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare but potentially curable cause of pulmonary hypertension (PH). Currently PH is diagnosed by right heart catheterisation. Computed tomography (CT) is used for ruling out other causes and operative planning. This study aims to evaluate importance of different quantitative/qualitative imaging features and develop a supervised machine learning (ML) model to predict hemodynamic risk groups. 127 Patients with diagnosed CTEPH who received preoperative right heart catheterization and thoracic CTA examinations (39 ECG-gated; 88 non-ECG gated) were included. 19 qualitative/quantitative imaging features and 3 hemodynamic parameters [mean pulmonary artery pressure, right atrial pressure (RAP), pulmonary artery oxygen saturation (PA SaO2)] were gathered. Diameter-based CT features were measured in axial and adjusted multiplane reconstructions (MPR). Univariate analysis was performed for qualitative and quantitative features. A random forest algorithm was trained on imaging features to predict hemodynamic risk groups. Feature importance was calculated for all models. Qualitative and quantitative parameters showed no significant differences between ECG and non-ECG gated CTs. Depending on reconstruction plane, five quantitative features were significantly different, but mean absolute difference between parameters (MPR vs. axial) was 0.3 mm with no difference in correlation with hemodynamic parameters. Univariate analysis showed moderate to strong correlation for multiple imaging features with hemodynamic parameters. The model achieved an AUC score of 0.82 for the mPAP based risk stratification and 0.74 for the PA SaO2 risk stratification. Contrast agent retention in hepatic vein, mosaic attenuation pattern and the ratio right atrium/left ventricle were the most important features among other parameters. Quantitative and qualitative imaging features of reconstructions correlate with hemodynamic parameters in preoperative CTEPH patients-regardless of MPR adaption. Machine learning based analysis of preoperative imaging features can be used for non-invasive risk stratification. Qualitative features seem to be more important than previously anticipated.


Asunto(s)
Hipertensión Pulmonar , Embolia Pulmonar , Humanos , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X/métodos , Hemodinámica , Aprendizaje Automático , Enfermedad Crónica
20.
Kidney Blood Press Res ; 37(1): 58-67, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23548813

RESUMEN

BACKGROUND/AIMS: Dry weight estimation in hemodialysis patients is still a substantial problem. Despite meticulous clinical assessment, fluid overload is common, leading to hypertension and left ventricular hypertrophy (LVH). Segmental calf bioimpedance spectroscopy (cBIS) is a novel tool for dry weight assessment. Here we tested the hypothesis, that its clinical routine use reduces arterial hypertension and left ventricular mass. METHODS: Left ventricular mass (determined by magnetic resonance imaging), blood pressure and antihypertensive medication (defined daily doses, ddd) were assessed at baseline (BL). Thereafter post-dialytic target weight was reduced until cBIS-defined dry weight was reached (DW). During a 6-month follow up, DW was re-evaluated monthly by cBIS and end-dialytic weight was adjusted correspondingly. At the end, left ventricular mass, blood pressure and antihypertensive medication were determined a 3rd time (follow-up, FU). RESULTS: Eleven out of 15 patients were available for analysis after 6 months. Left ventricular mass showed a declining trend during the study period (Mean±SD; BL 145±54 g; DW 142±55 g; FU 137±52 g; p=0.61, linear mixed model). Comparable results were obtained for systolic blood pressure (BL 158±18 mmHg; DW 144±19 mmHg; FU 149±21 mmHg; p=0.07), and antihypertensive medication (BL 3.28±2.82ddd; DW 2.86±2.81ddd; FU 3.36±3.05ddd; p=0.37). CONCLUSIONS: We conclude that attainment of dry weight assessed by cBIS tends to reduce left ventricular mass and blood pressure while antihypertensive medication remains unchanged. While the study was underpowered, its results provide an important hypothesis generating data basis for the design of larger studies.


Asunto(s)
Composición Corporal/fisiología , Peso Corporal/fisiología , Espectroscopía Dieléctrica , Hipertensión/fisiopatología , Hipertrofia Ventricular Izquierda/fisiopatología , Diálisis Renal , Adulto , Anciano , Anciano de 80 o más Años , Espectroscopía Dieléctrica/métodos , Impedancia Eléctrica , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/diagnóstico , Hipertensión/terapia , Hipertrofia Ventricular Izquierda/diagnóstico , Hipertrofia Ventricular Izquierda/terapia , Pierna/fisiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diálisis Renal/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA