1.
Br J Radiol ; 93(1115): 20200645, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32822540

RESUMEN

OBJECTIVE: To report our experience on stereotactic body radiotherapy (SBRT) in adrenal metastases from lung cancer. METHODS: 37 oligometastatic lung cancer patients with 38 adrenal metastases submitted to SBRT were retrospectively analyzed. SBRT was delivered by volumetric modulated arc therapy (VMAT) or helical tomotherapy (HT). Primary study end point was local recurrence-free survival (LR-FS) and secondary end points were distant-progression free survival (d-PFS) and overall survival (OS). RESULTS: Median age was 67 years and primary tumor was non-small-cell lung cancer in 27 (73%) and small-cell lung cancer in 10 (27%) patients. Adrenal metastases were in the left side in 66% cases. Median prescribed dose was 30 Gy in 5 fractions for a median biologically equivalent dose (α/ß ratio 10 Gy, BED10) of 48 Gy. Most patients (62%) were submitted to SBRT alone, while the others (38%) received chemo-, immune- or target- therapies. Median follow-up was 10.5 months, median OS 16 months and median d-PFS 3 months. 27 (70%) patients obtained a local control with a median LR-FS of 32 months. LR-FS was significantly related to BED10 with a better LC with BED10 ≥72 Gy, 1- and 2 year LR-FS rates were 54.1±11.6% and 45±12.7% vs 100 and 100% for BED ≤59.5 Gy and BED ≥72 Gy, respectively (p = 0.05). There was no severe toxicity. CONCLUSION: SBRT was effective and safe in lung cancer adrenal metastases. A dose-response relationship was found between BED10 >72 Gy and better local control. No significant toxicity was registered thanks to the respect of dose constraints and suspension of chemo- and target-therapies. ADVANCES IN KNOWLEDGE: SBRT with a BED10 >72 Gy is an effective treatment for adrenal oligometastatic lung cancer patients.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/patología , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Carcinoma Pulmonar de Células Pequeñas/radioterapia , Neoplasias de las Glándulas Suprarrenales/mortalidad , Neoplasias de las Glándulas Suprarrenales/secundario , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/secundario , Terapia Combinada/métodos , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Neoplasias Pulmonares/mortalidad , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Estudios Retrospectivos , Carcinoma Pulmonar de Células Pequeñas/mortalidad , Carcinoma Pulmonar de Células Pequeñas/secundario
2.
Phys Med ; 41: 117-123, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28457786

RESUMEN

PURPOSE: The aim was to calibrate gamma cameras in the framework of the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases. Equipments of several manufacturers and different models were used. METHODS: Eleven gamma cameras (3/8- and 5/8-inch crystal) were used, acquiring planar static images with double-peak (82 and 154keV, 20% wide) and MEGP collimator. The sensitivity was measured in air, varying source-detector distance and source size. Transmission curves were measured, calculating the parameters used for attenuation/scatter correction with the pseudo-extrapolation number method, and assessing their variations with the source size. RESULTS: Values of the calibration factor (geometric mean of both detector sensitivities) ranged from 41.1 to 113.9cps/MBq. For the smallest source (diameter of 3.5cm), the calibration factor decrease ranged from -30% to -4%, highlighting the importance of partial volume effects according to the equipment involved. The sensitivity variation with the source-detector distance, with respect to the 15cm-value, reached 10% (in absolute value) in the range 5-30cm, but fixing the distance between the two heads, the calibration factor variation with the distance from the midline was within 3.6%. Appreciable variation of the transmission curves with the source size were observed, examining the results obtained with six gamma cameras. CONCLUSION: Assessments of sensitivity and transmission curve variations with source size should be regularly implemented in calibration procedures. The results of this study represent a useful compendium to check the obtained calibrations for dosimetric purposes.


Asunto(s)
Neoplasias Óseas/radioterapia , Cámaras gamma , Radiometría/normas , Calibración , Humanos , Italia