Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Anal Chem ; 87(11): 5614-9, 2015 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-25946522

RESUMEN

Laser-induced acoustic desorption (LIAD) has recently been established as a tool for analytical chemistry. It is capable of launching intact, neutral, or low charged molecules into a high vacuum environment. This makes it ideally suited to mass spectrometry. LIAD can be used with fragile biomolecules and very massive compounds alike. Here, we apply LIAD time-of-flight mass spectrometry (TOF-MS) to the natural biochromophores chlorophyll, hemin, bilirubin, and biliverdin and to high mass fluoroalkyl-functionalized porphyrins. We characterize the variation in the molecular fragmentation patterns as a function of the desorption and the VUV postionization laser intensity. We find that LIAD can produce molecular beams an order of magnitude slower than matrix-assisted laser desorption (MALD), although this depends on the substrate material. Using titanium foils we observe a most probable velocity of 20 m/s for functionalized molecules with a mass m = 10,000 Da.


Asunto(s)
Rayos Láser , Porfirinas/química , Acústica , Bilirrubina/química , Clorofila/química , Hemina/química , Estructura Molecular , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
2.
Arch Osteoporos ; 17(1): 4, 2021 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-34893935

RESUMEN

PURPOSE: To investigate the time and effort needed to perform vertebral morphometry, as well as inter-observer agreement for identification of vertebral fractures on vertebral fracture assessment (VFA) images. METHODS: Ninety-six images were retrospectively selected, and three radiographers independently performed semi-automatic 6-point morphometry. Fractures were identified and graded using the Genant classification. Time needed to annotate each image was recorded, and reader fatigue was assessed using a modified Simulator Sickness Questionnaire (SSQ). Inter-observer agreement was assessed per-patient and per-vertebra for detecting fractures of all grades (grades 1-3) and for grade 2 and 3 fractures using the kappa statistic. Variability in measured vertebral height was evaluated using the intraclass correlation coefficient (ICC). RESULTS: Per-patient agreement was 0.59 for grades 1-3 fracture detection, and 0.65 for grades 2-3 only. Agreement for per-vertebra fracture classification was 0.92. Vertebral height measurements had an ICC of 0.96. Time needed to annotate VFA images ranged between 91 and 540 s, with a mean annotation time of 259 s. Mean SSQ scores were significantly lower at the start of a reading session (1.29; 95% CI: 0.81-1.77) compared to the end of a session (3.25; 95% CI: 2.60-3.90; p < 0.001). CONCLUSION: Agreement for detection of patients with vertebral fractures was only moderate, and vertebral morphometry requires substantial time investment. This indicates that there is a potential benefit for automating VFA, both in improving inter-observer agreement and in decreasing reading time and burden on readers.


Asunto(s)
Fracturas de la Columna Vertebral , Absorciometría de Fotón , Humanos , Vértebras Lumbares/lesiones , Variaciones Dependientes del Observador , Estudios Retrospectivos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Vértebras Torácicas
3.
Cardiovasc Diagn Ther ; 8(6): 820-824, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30740331

RESUMEN

Current balloon expandable and self-expanding valves have limitations for the treatment of the enlarged right ventricular outflow tract. We report the first use of a tailored Zenith graft in composition with an Edwards Sapien S3 valve as an alternative to high-risk surgery for the treatment of a spontaneously ruptured homograft in an adult congenital heart disease patient.

4.
J Phys Chem B ; 119(18): 5824-31, 2015 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-25861001

RESUMEN

The effect of ion binding in the selectivity filter of the potassium channel KcsA is investigated by combining amide I Fourier-transform infrared spectroscopy with structure-based spectral modeling. Experimental difference IR spectra between K(+)-bound KcsA and Na(+)-bound KcsA are in good qualitative agreement with spectra modeled from structural ensembles generated from molecular dynamics simulations. The molecular origins of the vibrational modes contributing to differences in these spectra are determined not only from structural differences in the selectivity filter but also from the pore helices surrounding this region. Furthermore, the coordination of K(+) or Na(+) to carbonyls in the selectivity filter effectively decouples the vibrations of those carbonyls from the rest of the protein, creating local probes of the electrostatic environment. The results suggest that it is necessary to include the influence of the surrounding helices in discussing selectivity and transport in KcsA and, on a more general level, that IR spectroscopy offers a nonperturbative route to studying the structure and dynamics of ion channels.


Asunto(s)
Iones/química , Canales de Potasio con Entrada de Voltaje/química , Escherichia coli , Simulación del Acoplamiento Molecular , Potasio/química , Canales de Potasio con Entrada de Voltaje/genética , Cloruro de Potasio/química , Conformación Proteica , Sodio/química , Cloruro de Sodio/química , Espectroscopía Infrarroja por Transformada de Fourier , Electricidad Estática , Vibración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA