Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Z Med Phys ; 30(2): 116-134, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31859029

RESUMEN

BACKGROUND: Currently, there is a high interest in 177Lu targeted radionuclide therapies, which could be attributed to favorable results obtained from 177Lu compounds targeting neuro-endocrine and prostate tumors. SPECT based dosimetry could be used for deriving dose values for individual voxels, as is the standard in external-beam radiation-therapy (EBRT). For this a time-activity-curve (TAC) at voxel resolution and also a voxel-wise modeling of radiation energy deposition are necessary. But a voxel-wise determination of TACs is problematic, since several confounding factors exist, such as e.g. poor count-statistics or registration inaccuracies, which add noise to the observed activity states. A particle filter (PF) is a class of methods which applies regularization based on a model of the temporal evolution of activity states. The aim of this study is to introduce the application of PFs for de-noising of per-voxel time-activity curves. METHODS: We applied a PF for de-noising the TACs of 26 patients, who underwent 177Lu-DOTATOC or -PSMA therapy. The TACs were obtained from fully-quantitative, serial SPECT(/CT) data, acquired at 4h, 24h, 48h, 72h p.i. The model used in the PF was a mono-exponential decay and its free parameters were determined based on objective criteria. The time-integrated activities (TIA) resulting from the PF (PFF) were compared to the results of a mono-exponential fit (SF) of individual voxels in several volumes of interest (kidneys, spleen, tumors). Additionally, an organ-averaged TIA was derived from whole-organ VOIs and subsequent curve-fitting. This whole-organ TIA was also compared to the whole-organ TIAs obtained from summation of the voxel-wise TIAs from PFF and SF. RESULTS: The number of particles was set to 1000. Optimal values for noise of observations and noise of the model were 0.25 and 0.5, respectively. The deviation of whole-organ TIAs from conventional organ-based dosimetry and the summation of the voxel-wise TIAs was substantial for SF (kidneys -22.3%, spleen -49.6%, tumor -60.0%), as well as for PFF (kidneys -37.1%, spleen -57.9%, tumor -70.9%). The distribution of voxel-wise half-lives resulting from the PFF method was considerably closer to the organ-averaged value, and the number of implausibly long half-lives (>physical HL) was reduced. CONCLUSION: The PFF leads to voxel-wise half-lives, which are more plausible than those resulting from SF. However, one has to admit that voxel-wise fitting generally leads to considerable deviations from the organ-averaged TIA as obtained by conventional whole-organ evaluation. Unfortunately, we did not have ground-truth TIA of our patient data and proper ground-truth could even be impossible to obtain. Nevertheless, there are strong indicators that particle filtering can be used for reducing voxel-wise TAC noise.


Asunto(s)
Luteína/uso terapéutico , Tumores Neuroendocrinos/radioterapia , Octreótido/análogos & derivados , Neoplasias de la Próstata/radioterapia , Radiofármacos/uso terapéutico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico por imagen , Octreótido/uso terapéutico , Antígeno Prostático Específico/uso terapéutico , Neoplasias de la Próstata/diagnóstico por imagen , Radiometría , Relación Señal-Ruido , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada de Emisión de Fotón Único/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA