1.
Health Phys ; 121(1): 18-29, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33867436

RESUMEN

ABSTRACT: The influence of the angular deviation of the tube during digital breast tomosynthesis (DBT) acquisition to the dose in the examined breast and in other organs and tissues is not well known. In this work, the Monte Carlo method was used with an adult female virtual anthropomorphic phantom to investigate the impact of this angular variation on the breast dose. The absorbed dose in the examined breast was normalized by the air kerma, which resulted in an absorbed dose coefficient (DT/Kair) for the breast. The absorbed dose in each organ was normalized by the glandular dose in the breast, resulting in the relative organ dose (ROD). An adult female virtual anthropomorphic phantom (FSTA_M50_H50) was incorporated into a scenario containing tomosynthesis equipment with Mo/Mo, Mo/Rh, and W/Rh target/filter combinations and tube voltages of 28 kV. The comparison between the results of the simulations considering digital mammography (DM) and DBT data showed that the DT/Kair values for the examined breast obtained with the DBT parameters were up to 24 times higher than with the DT/Kair obtained with DM parameters. A DT/Kair of 0.97 × 10-1 mGy mGy-1 was obtained in a DBT exam of the right breast. Considering the other organs, the highest ROD values were observed in the thyroid (6.45 × 10-4), eyes (3.87 × 10-4), liver (1.95 × 10-5), and eye lenses (3.21 × 10-3). A variation in the absorbed dose values for the breast and other organs was observed for all projections different from 0°.


Asunto(s)
Mamografía , Radiometría , Mama/diagnóstico por imagen , Femenino , Humanos , Método de Montecarlo , Fantasmas de Imagen , Dosis de Radiación , Radiometría/métodos
2.
Phys Med ; 45: 35-43, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29472088

RESUMEN

In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes. In addition to these phantoms, a female and a male phantom, named FASH3 and MASH3 (reference virtual anthropomorphic phantoms), were also used to represent the medical radiation workers. The CC values, obtained as a function of the dose area product, were calculated for 87 exposure scenarios. In each exposure scenario, three phantoms, implemented in the MCNPX 2.7.0 code, were simultaneously used. These phantoms were utilized to represent a patient and medical radiation workers. The results showed that increasing the BMI of the patient, adjusted for each patient protocol, the CC values for medical radiation workers decrease. It is important to note that these results were obtained with fixed exposure parameters.


Asunto(s)
Abdomen/diagnóstico por imagen , Fluoroscopía/efectos adversos , Personal de Salud , Exposición Profesional , Dosis de Radiación , Índice de Masa Corporal , Peso Corporal , Simulación por Computador , Femenino , Fluoroscopía/instrumentación , Humanos , Masculino , Modelos Anatómicos , Método de Montecarlo , Fantasmas de Imagen , Interfaz Usuario-Computador