1.
Int J Radiat Oncol Biol Phys ; 111(4): 1011-1022, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34343608

RESUMEN

PURPOSE: To establish and investigate the effects of dose, linear energy transfer (LET), and O2 concentration on biologic response to ultrahigh dose rate (uHDR; FLASH) helium ion beams compared with standard dose rate (SDR) irradiation. METHODS AND MATERIALS: Beam delivery settings for raster-scanned helium ions at both uHDR and SDR were tuned to achieve >100 Gy/s and ∼0.1 Gy/s, respectively. For both SDR and uHDR, plan optimization and calibration for 10 × 10-mm2 fields were performed to assess in vitro response at an LET range of 4.5 to 16 keV/µm. Clonogenic survival assay was conducted at doses ranging from 2 to 12 Gy in 2 human lung epithelial cell lines (A549 and H1437). Radiation-induced nuclear γH2AX foci (RIF) were assessed in both epithelial cell lines and primary human pulmonary fibroblasts. RESULTS: Average dose rates achieved were 185 Gy/s and 0.12 Gy/s for uHDR and SDR, respectively. No differences in cellular response to SDR versus uHDR were observed for all tested doses at 21% O2, and at 2 and 4 Gy at 1% O2. In contrast, at 1% O2 and a dose threshold of ≳8 Gy cell survival was higher and correlated with reduced nuclear γH2AX RIF signal, indicating FLASH sparing effect in the investigated cell lines irradiated with uHDR compared with SDR. CONCLUSIONS: The first uHDR delivery of raster-scanned particle beams was achieved using helium ions, reaching FLASH-level dose-rates of >100 Gy/s. Baseline oxygen levels and delivered dose (≳8 Gy) play a pivotal role, irrespective of the studied cell lines, for observation of a sparing effect for helium ions.


Asunto(s)
Helio , Transferencia Lineal de Energía , Línea Celular Tumoral , Supervivencia Celular , Humanos , Iones , Oxígeno
2.
Phys Med Biol ; 60(3): N59-69, 2015 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-25590354

RESUMEN

At particle therapy facilities with pencil beam scanning, the implementation of a ripple filter (RiFi) broadens the Bragg peak, so fewer energy steps from the accelerator are required for a homogeneous dose coverage of the planning target volume (PTV). However, sharply focusing the scanned pencil beams at the RiFi plane by ion optical settings can lead to a Moiré effect, causing fluence inhomogeneities at the isocenter. This has been experimentally proven at the Heidelberg Ionenstrahl-Therapiezentrum (HIT), Universitätsklinikum Heidelberg, Germany. 150 MeV u(-1) carbon-12 ions are used for irradiation with a 3 mm thick RiFi. The beam is focused in front of and as close to the RiFi plane as possible. The pencil beam width is estimated to be 0.78 mm at a 93 mm distance from the RiFi. Radiographic films are used to obtain the fluence profile 30 mm in front of the isocenter, 930 mm from the RiFi. The Monte Carlo (MC) code SHIELD-HIT12A is used to determine the RiFi-induced inhomogeneities in the fluence distribution at the isocenter for a similar setup, pencil beam widths at the RiFi plane ranging from σχ(RiFi to 1.2 mm and for scanning step sizes ranging from 1.5 to 3.7 mm. The beam application and monitoring system (BAMS) used at HIT is modelled and simulated. When the width of the pencil beams at the RiFi plane is much smaller than the scanning step size, the resulting inhomogeneous fluence distribution at the RiFi plane interfers with the inhomogeneous RiFi mass distribution and fluence inhomogeneity can be observed at the isocenter as large as an 8% deviation from the mean fluence. The inverse of the fluence ripple period at the isocenter is found to be the difference between the inverse of the RiFi period and the inverse of the scanning step size. We have been able to use MC simulations to reproduce the spacing of the ripple stripes seen in films irradiated at HIT. Our findings clearly indicate that pencil beams sharply focused near the RiFi plane result in fluence inhomogeneity at the isocenter. In the normal clinical application, such a setting should generally be avoided.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioisótopos de Carbono/uso terapéutico , Método de Montecarlo , Dosificación Radioterapéutica , Película para Rayos X