Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 387(25): 2356-2361, 2022 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-36546627

RESUMEN

A 27-year-old patient with a history of severe obstetrical complications and arterial thrombosis received a diagnosis of hereditary thrombotic thrombocytopenic purpura (TTP) due to severe ADAMTS13 deficiency when she presented with an acute episode in the 30th week of her second pregnancy. When the acute episode of hereditary TTP became plasma-refractory and fetal death was imminent, weekly injections of recombinant ADAMTS13 at a dose of 40 U per kilogram of body weight were initiated. The patient's platelet count normalized, and the growth of the fetus stabilized. At 37 weeks 1 day of gestation, a small-for-gestational-age boy was delivered by cesarean section. At the time of this report, the patient and her son were well, and she continued to receive injections of recombinant ADAMTS13 every 2 weeks. (Funded by the Swiss National Science Foundation.).


Asunto(s)
Complicaciones Hematológicas del Embarazo , Púrpura Trombocitopénica Trombótica , Adulto , Femenino , Humanos , Embarazo , Proteína ADAMTS13/administración & dosificación , Proteína ADAMTS13/deficiencia , Proteína ADAMTS13/genética , Proteína ADAMTS13/uso terapéutico , Cesárea , Plasma , Recuento de Plaquetas , Púrpura Trombocitopénica Trombótica/diagnóstico , Púrpura Trombocitopénica Trombótica/genética , Púrpura Trombocitopénica Trombótica/terapia , Resultado del Embarazo , Complicaciones Hematológicas del Embarazo/genética , Complicaciones Hematológicas del Embarazo/terapia
2.
Br J Anaesth ; 132(4): 675-684, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38336516

RESUMEN

BACKGROUND: In 2022, the European Society of Cardiology updated guidelines for preoperative evaluation. The aims of this study were to quantify: (1) the impact of the updated recommendations on the yield of pathological findings compared with the previous guidelines published in 2014; (2) the impact of preoperative B-type natriuretic peptide (NT-proBNP) use for risk estimation on the yield of pathological findings; and (3) the association between 2022 guideline adherence and outcomes. METHODS: This was a secondary analysis of MET-REPAIR, an international, prospective observational cohort study (NCT03016936). Primary endpoints were reduced ejection fraction (EF<40%), stress-induced ischaemia, and major adverse cardiovascular events (MACE). The explanatory variables were class of recommendations for transthoracic echocardiography (TTE), stress imaging, and guideline adherence. We conducted second-order Monte Carlo simulations and multivariable regression. RESULTS: In total, 15,529 patients (39% female, median age 72 [inter-quartile range: 67-78] yr) were included. The 2022 update changed the recommendation for preoperative TTE in 39.7% patients, and for preoperative stress imaging in 12.9% patients. The update resulted in missing 1 EF <40% every 3 fewer conducted TTE, and in 4 additional stress imaging per 1 additionally detected ischaemia events. For cardiac stress testing, four more investigations were performed for every 1 additionally detected ischaemia episodes. Use of NT-proBNP did not improve the yield of pathological findings. Multivariable regression analysis failed to find an association between adherence to the updated guidelines and MACE. CONCLUSIONS: The 2022 update for preoperative cardiac testing resulted in a relevant increase in tests receiving a stronger recommendation. The updated recommendations for TTE did not improve the yield of pathological cardiac testing.


Asunto(s)
Cardiología , Humanos , Femenino , Anciano , Masculino , Estudios Prospectivos , Ecocardiografía , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Isquemia , Biomarcadores
3.
Br J Anaesth ; 127(5): 769-777, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34454710

RESUMEN

BACKGROUND: Acoustic alarms in medical devices are vital for patient safety. State-of-the-art patient monitoring alarms are indistinguishable and contribute to alarm fatigue. There are two promising new sound modalities for vital sign alarms. Auditory icons convey alarms as brief metaphorical sounds, and voice alerts transmit information using a clear-spoken language. We compared how reliably healthcare professionals identified alarms using these two modalities. METHODS: This investigator-initiated computer-based multicentre simulation study included 28 anaesthesia providers who were asked to identify vital sign alarms in randomised order, once with voice alerts and once with auditory icons. We further assessed time to decision, diagnostic confidence, and perceived helpfulness. We analysed the results using mixed models, adjusted for possible confounders. RESULTS: We assessed 14 alarms for each modality, resulting in 392 comparisons across all participants. Compared with auditory icons, healthcare providers had 58 times higher odds of correctly identifying alarms using voice alerts (odds ratio 58.0; 95% confidence interval [CI]: 25.1-133.6; P<0.001), made their decisions about 14 s faster (coefficient -13.9; 95% CI: -15.8 to -12.1 s; P<0.001), perceived higher diagnostic confidence (100% [392 of 392] vs 43% [169 of 392; P<0.001]), and rated voice alerts as more helpful (odds ratio 138.2; 95% CI: 64.9-294.1; P<0.001). The participants were able to identify significantly higher proportions of alarms with voice alerts (98.5%; P<0.001) and auditory icons (54.1%; P<0.001) compared with state-of-the-art alarms (17.9%). CONCLUSIONS: Voice alerts were superior to auditory icons, and both were superior to current state-of-the-art auditory alarms. These findings demonstrate the potential that voice alerts hold for patient monitoring.


Asunto(s)
Acústica , Alarmas Clínicas , Monitoreo Fisiológico/métodos , Voz , Adulto , Percepción Auditiva , Simulación por Computador , Toma de Decisiones , Diseño de Equipo , Femenino , Personal de Salud/estadística & datos numéricos , Humanos , Masculino , Factores de Tiempo
4.
BMC Med Inform Decis Mak ; 20(1): 26, 2020 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-32041584

RESUMEN

BACKGROUND: Maintaining adequate situation awareness is crucial for patient safety. Previous studies found that the use of avatar-based monitoring (Visual Patient Technology) improved the perception of vital signs compared to conventional monitoring showing numerical and waveform data; and was further associated with a reduction of perceived workload. In this study, we aimed to evaluate the effectiveness of Visual Patient Technology on perceptive performance and perceived workload when monitoring multiple patients at the same time, such as in central station monitors in intensive care units or operating rooms. METHODS: A prospective, within-subject, computer-based laboratory study was performed in two tertiary care hospitals in Switzerland in 2018. Thirty-eight physician and nurse anesthetists volunteered for the study. The participants were shown four different central monitor scenarios in sequence, where each scenario displayed two critical and four healthy patients simultaneously for 10 or 30 s. After each scenario, participants had to recall the vital signs of the critical patients. Perceived workload was assessed with the National Aeronautics and Space Administration Task-Load-Index (NASA TLX) questionnaire. RESULTS: In the 10-s scenarios, the median number of remembered vital signs significantly improved from 7 to 11 using avatar-based versus conventional monitoring with a mean of differences of 4 vital signs, 95% confidence interval (CI) 2 to 6, p < 0.001. At the same time, the median NASA TLX scores were significantly lower for avatar-based monitoring (67 vs. 77) with a mean of differences of 6 points, 95% CI 0.5 to 11, p = 0.034. In the 30-s scenarios, vital sign perception and workload did not differ significantly. CONCLUSIONS: In central monitor multiple patient monitoring, we found a significant improvement of vital sign perception and reduction of perceived workload using Visual Patient Technology, compared to conventional monitoring. The technology enabled improved assessment of patient status and may, thereby, help to increase situation awareness and enhance patient safety.


Asunto(s)
Anestesistas/psicología , Tecnología Biomédica/instrumentación , Simulación por Computador , Terminales de Computador , Monitoreo Fisiológico/instrumentación , Signos Vitales , Adulto , Anciano , Concienciación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Percepción , Estudios Prospectivos , Suiza , Carga de Trabajo
5.
J Clin Monit Comput ; 34(6): 1369-1378, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31768924

RESUMEN

Patient monitoring requires constant attention and may be particularly vulnerable to distractions, which frequently occur during perioperative work. In this study, we compared anesthesia providers' perceptive performance and perceived workload under distraction for conventional and avatar-based monitoring, a situation awareness-based technology that displays patient status as an animated patient model. In this prospective, multicenter study with a within-subject design, 38 participants evaluated scenarios of 3- and 10-s durations using conventional and avatar-based monitoring, under standardized distraction in the form of a simple calculation task. We quantified perceptual performance as the number of vital signs correctly remembered out of the total of 11 vital signs shown. We quantified perceived workload using the National Aeronautics and Space Administration Task Load Index score. Anesthesia providers remembered more vital signs under distraction using the avatar monitoring technology in the 3-s scenario: 6 (interquartile range [IQR] 5-7) vs. 3 (IQR 2-4), p < 0.001, mean of differences (MoD): 3 (95% confidence interval [95% CI] 1 to 4), and in the 10-s monitoring task: 6 (IQR 5-8) vs. 4 (IQR 2-7), p = 0.028, MoD: 1 (95% CI 0.2 to 3). Participants rated perceived workload lower under distraction with the avatar in the 3-s scenario: 65 (IQR 40-79) vs. 75 (IQR 51-88), p = 0.007, MoD: 9 (95% CI 3 to 15), and in the 10-s scenario: 68 (IQR 50-80) vs. 75 (IQR 65-86), p = 0.019, MoD: 10 (95% CI 2 to 18). Avatar-based monitoring improved anesthesia providers' perceptive performance under distraction and reduced perceived workload. This technology could help to improve caregivers' situation awareness, especially in high-workload situations.


Asunto(s)
Cuidadores , Signos Vitales , Humanos , Monitoreo Fisiológico , Estudios Prospectivos , Carga de Trabajo
7.
J Med Internet Res ; 21(7): e13041, 2019 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-31317870

RESUMEN

BACKGROUND: Continuous patient monitoring has been described by the World Health Organization as extremely important and is widely used in anesthesia, intensive care medicine, and emergency medicine. However, current state-of-the-art number- and waveform-based monitoring does not ideally support human users in acquiring quick, confident interpretations with low cognitive effort, and there are additional problematic aspects such as alarm fatigue. We developed a visualization technology (Visual Patient), specifically designed to help caregivers gain situation awareness quickly, which presents vital sign information in the form of an animated avatar of the monitored patient. We suspected that because of the way it displays the information as large, colorful, moving graphic objects, caregivers might be able to perform patient monitoring using their peripheral vision, which may facilitate quicker detection of anomalies, independently of acoustic alarms. OBJECTIVE: In this study, we tested the hypothesis that avatar-based monitoring, when observed with peripheral vision only, increases the number of perceptible changes in patient status as well as caregivers' perceived diagnostic confidence compared with a high-fidelity simulation of conventional monitoring, when observed with peripheral vision only. METHODS: We conducted a multicenter comparative study with a within-participant design in which anesthesiologists with their peripheral field of vision looked at 2 patient-monitoring scenarios and tried to identify changes in patient status. To ensure the best possible experimental conditions, we used an eye tracker, which recorded the eye movements of the participants and confirmed that they only looked at the monitoring scenarios with their peripheral vision. RESULTS: Overall, 30 participants evaluated 18 different patient status changes with each technology (avatar and conventional patient monitoring). With conventional patient monitoring, participants could only detect those 3 changes in patient status that are associated with a change in the auditory pulse tone display, that is, tachycardia (faster beeping), bradycardia (slower beeping), and desaturation (lower pitch of beeping). With the avatar, the median number of detected vital sign changes quadrupled from 3 to 12 (P<.001) in scenario 1, and more than doubled from 3 to 8 (P<.001) in scenario 2. Median perceived diagnostic confidence was confident for both scenarios with the avatar and unconfident in scenario 1 (P<.001), and very unconfident in scenario 2 (P=.024) with conventional monitoring. CONCLUSIONS: This study introduces the concept of peripheral vision monitoring. The test performed showed clearly that an avatar-based display is superior to a standard numeric display for peripheral vision. Avatar-based monitoring could potentially make much more of the patient monitoring information available to caregivers for longer time periods per case. Our results indicate that the optimal information transmission would consist of a combination of auditory and avatar-based monitoring.


Asunto(s)
Movimientos Oculares/fisiología , Monitoreo Fisiológico/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
8.
BMC Anesthesiol ; 18(1): 55, 2018 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-29788919

RESUMEN

BACKGROUND: Functional hemodynamic parameters such as stroke volume and pulse pressure variation (SVV and PPV) have been shown to be reliable predictors of fluid responsiveness in mechanically ventilated patients. Today, different minimally- and non-invasive hemodynamic monitoring systems measure functional hemodynamic parameters. Although some of these parameters are described by the same name, they differ in their measurement technique and thus may provide different results. We aimed to test the performance of seven functional hemodynamic parameters simultaneously in the same clinical setting. METHODS: Hemodynamic measurements were done in 30 cardiac surgery patients that were mechanically ventilated. Before and after a standardized intravenous fluid bolus, hemodynamics were measured by the following monitoring systems: PiCCOplus (SVVPiCCO, PPVPiCCO), LiDCOrapid (SVVLiDCO, PPVLiDCO), FloTrac (SVVFloTrac), Philips Intellivue (PPVPhilips) and Masimo pulse oximeter (pleth variability index, PVI). Prediction of fluid responsiveness was tested by calculation of receiver operating characteristic (ROC) curves including a gray zone approach and compared using Fisher's Z-Test. RESULTS: Fluid administration resulted in an increase in cardiac output, while all functional hemodynamic parameters decreased. A wide range of areas under the ROC-curve (AUC's) was observed: AUC-SVVPiCCO = 0.91, AUC-PPVPiCCO = 0.88, AUC-SVVLiDCO = 0.78, AUC-PPVLiDCO = 0.89, AUC-SVVFloTrac = 0.87, AUC-PPVPhilips = 0.92 and AUC-PVI = 0.68. Optimal threshold values for prediction of fluid responsiveness ranged between 9.5 and 17.5%. Lowest threshold values were observed for SVVLiDCO, highest for PVI. CONCLUSION: All functional hemodynamic parameters tested except for PVI showed that their use allows a reliable identification of potential fluid responders. PVI however, may not be suitable after cardiac surgery to predict fluid responsiveness. TRIAL REGISTRATION: NCT02571465 , registered on October 7th, 2015 (retrospectively registered).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Fluidoterapia , Hemodinámica/fisiología , Monitoreo Fisiológico/métodos , Respiración Artificial , Equilibrio Hidroelectrolítico/fisiología , Humanos , Reproducibilidad de los Resultados
9.
J Cardiothorac Vasc Anesth ; 32(2): 715-722, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29217236

RESUMEN

OBJECTIVE: The aim of this study was to analyze the accuracy, precision, and trending ability of the following 4 pulse wave analysis devices to measure continuous cardiac output: PiCCO2 ([PCCO]; Pulsion Medical System, Munich, Germany); LiDCORapid ([LCCO]; LiDCO Ltd, London, UK); FloTrac/Vigileo ([FCCO]; Edwards Lifesciences, Irvine, CA); and Nexfin ([NCCO]; BMEYE, Amsterdam, The Netherlands). DESIGN: Prospective, observational clinical study. SETTING: Intensive care unit of a single-center, teaching hospital. PARTICIPANTS: The study comprised 22 adult patients after elective coronary artery bypass surgery. INTERVENTIONS: Three measurement cycles were performed in all patient durings their immediate postoperative intensive care stay before and after fluid loading. Hemodynamic measurements were performed 5 minutes before and immediately after the administration of 500 mL colloidal fluid over 20 minutes. MEASUREMENTS AND MAIN RESULTS: PCCO, LCCO, FCCO, and NCCO were assessed and compared with cardiac output derived from intermittent transpulmonary thermodilution (ICO). One hundred thirty-two matched sets of data were available for analysis. Bland-Altman analysis using linear mixed effects models with random effects for patient and trial revealed a mean bias ±2 standard deviation (%error) of -0.86 ± 1.41 L/min (34.9%) for PCCO-ICO, -0.26 ± 2.81 L/min (46.3%) for LCCO-ICO, -0.28 ± 2.39 L/min (43.7%) for FCCO-ICO, and -0.93 ± 2.25 L/min (34.6%) for NCCO-ICO. Bland-Altman plots without adjustment for repeated measurements and replicates yielded considerably larger limits of agreement. Trend analysis for all techniques did not meet criteria for acceptable performance. CONCLUSIONS: All 4 tested devices using pulse wave analysis for measuring cardiac output failed to meet current criteria for meaningful and adequate accuracy, precision, and trending ability in cardiac output monitoring.


Asunto(s)
Gasto Cardíaco/fisiología , Unidades de Cuidados Intensivos/normas , Monitoreo Fisiológico/normas , Cuidados Posoperatorios/normas , Análisis de la Onda del Pulso/normas , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Cuidados Posoperatorios/métodos , Periodo Posoperatorio , Estudios Prospectivos , Análisis de la Onda del Pulso/métodos
10.
Anesthesiology ; 127(2): 307-316, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28570294

RESUMEN

BACKGROUND: Supraglottic airway devices commonly are used for securing the airway during general anesthesia. Occasionally, intubation with an endotracheal tube through a supraglottic airway is indicated. Reported success rates for blind intubation range from 15 to 97%. The authors thus investigated as their primary outcome the fraction of patients who could be intubated blindly with an Air-Qsp supraglottic airway device (Mercury Medical, USA). Second, the authors investigated the influence of muscle relaxation on air leakage pressure, predictors for failed blind intubation, and associated complications of using the supraglottic airway device. METHODS: The authors enrolled 1,000 adults having elective surgery with endotracheal intubation. After routine induction of general anesthesia, a supraglottic airway device was inserted and patients were ventilated intermittently. Air leak pressure was measured before and after full muscle relaxation. Up to two blind intubation attempts were performed. RESULTS: The supraglottic airway provided adequate ventilation and oxygenation in 99% of cases. Blind intubation succeeded in 78% of all patients (95% CI, 75 to 81%). However, the success rate was inconsistent among the three centers (P < 0.001): 80% (95% CI, 75 to 85%) at the Institute of Anesthesia and Pain Therapy, Kantonsspital Winterthur, Winterthur, Switzerland; 41% (95% CI, 29 to 53%) at the Department of Anesthesiology and Intensive Therapy, Medical University of Lodz, Lodz, Poland; and 84% (95% CI, 80 to 88%) at the Institute of Anesthesiology, University Hospital Zurich, Zurich, Switzerland. Leak pressure before relaxation correlated reasonably well with air leak pressure after relaxation. CONCLUSIONS: The supraglottic airway device reliably provided a good airway and allowed blind intubation in nearly 80% of patients. It is thus a reasonable initial approach to airway control. Muscle relaxation can be used safely when unparalyzed leak pressure is adequate.


Asunto(s)
Equipos Desechables , Intubación Intratraqueal/instrumentación , Máscaras Laríngeas , Adulto , Anciano , Estudios de Cohortes , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polonia , Estudios Prospectivos , Suiza
11.
Anesth Analg ; 124(3): 925-933, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28067701

RESUMEN

BACKGROUND: Pharmacologic pre- and postconditioning with sevoflurane compared with total IV anesthesia in patients undergoing liver surgery reduced complication rates as shown in 2 recent randomized controlled trials. However, the potential health economic consequences of these different anesthesia regimens have not yet been assessed. METHODS: An expostcost analysis of these 2 trials in 129 patients treated between 2006 and 2010 was performed. We analyzed direct medical costs for in-hospital stay and compared pharmacologic pre- and postconditioning with sevoflurane (intervention) with total IV anesthesia (control) from the perspective of a Swiss university hospital. Year 2015 costs, converted to US dollars, were derived from hospital cost accounting data and compared with a multivariable regression analysis adjusting for relevant covariables. Costs with negative prefix indicate savings and costs with positive prefix represent higher spending in our analysis. RESULTS: Treatment-related costs per patient showed a nonsignificant change by -12,697 US dollars (95% confidence interval [CI], 10,956 to -36,352; P = .29) with preconditioning and by -6139 US dollars (95% CI, 6723 to -19,000; P = .35) with postconditioning compared with the control group. Results were robust in our sensitivity analysis. For both procedures (control and intervention) together, major complications led to a significant increase in costs by 86,018 US dollars (95% CI, 13,839-158,198; P = .02) per patient compared with patients with no major complications. CONCLUSIONS: In this cost analysis, reduced in-hospital costs by pharmacologic conditioning with sevoflurane in patients undergoing liver surgery are suggested. This possible difference in costs compared with total IV anesthesia is the result of reduced complication rates with pharmacologic conditioning, because major complications have significant cost implications.


Asunto(s)
Anestesia Intravenosa/economía , Análisis Costo-Beneficio , Hepatopatías/economía , Hepatopatías/cirugía , Éteres Metílicos/administración & dosificación , Éteres Metílicos/economía , Adulto , Anciano , Anestesia Intravenosa/métodos , Análisis Costo-Beneficio/métodos , Femenino , Humanos , Tiempo de Internación/economía , Tiempo de Internación/tendencias , Hepatopatías/epidemiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/economía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Sevoflurano , Suiza/epidemiología
12.
J Clin Monit Comput ; 30(1): 13-22, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25721853

RESUMEN

Septic shock is a serious medical condition. With increased concerns about invasive techniques, a number of non-invasive and semi-invasive devices measuring cardiac output (CO) have become commercially available. The aim of the present study was to determine the accuracy, precision and trending abilities of the FloTrac and the continuous pulmonary artery catheter thermodilution technique determining CO in septic shock patients. Consecutive septic shock patients were included in two centres and CO was measured every 4 h up to 48 h by FloTrac (APCO) and by pulmonary artery catheter (PAC) using the continuous (CCO) and intermittent (ICO) technique. Forty-seven septic shock patients with 326 matched sets of APCO, CCO and ICO data were available for analysis. Bland and Altman analysis revealed a mean bias ±2 SD of 0.0 ± 2.14 L min(-1) for APCO-ICO (%error = 34.5 %) and 0.23 ± 2.55 L min(-1) for CCO-ICO (%error = 40.4 %). Trend analysis showed a concordance of 85 and 81 % for APCO and CCO, respectively. In contrast to CCO, APCO was influenced by systemic vascular resistance and by mean arterial pressure. In septic shock patients, APCO measurements assessed by FloTrac but also the established CCO measurements using the PAC did not meet the currently accepted statistical criteria indicating acceptable clinical performance.


Asunto(s)
Gasto Cardíaco , Diagnóstico por Computador/métodos , Presión Esfenoidal Pulmonar , Análisis de la Onda del Pulso/instrumentación , Choque Séptico/diagnóstico , Programas Informáticos , Calibración , Cateterismo Periférico/instrumentación , Cateterismo Periférico/métodos , Diagnóstico por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Pruebas de Función Cardíaca/instrumentación , Pruebas de Función Cardíaca/métodos , Humanos , Masculino , Persona de Mediana Edad , Análisis de la Onda del Pulso/métodos , Reproducibilidad de los Resultados , Arabia Saudita , Sensibilidad y Especificidad , Suiza , Termodilución/métodos
13.
J Cardiothorac Vasc Anesth ; 29(3): 715-22, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25864405

RESUMEN

OBJECTIVES: The aim of the study was to determine if Sonoclot with its sensitive glass bead-activated, viscoelastic test can predict postoperative bleeding in patients undergoing cardiac surgery at predefined time points. DESIGN: A prospective, observational clinical study. SETTING: A teaching hospital, single center. PARTICIPANTS: Consecutive patients undergoing cardiac surgery (N = 300). INTERVENTIONS: Besides routine laboratory coagulation studies and heparin management with standard (kaolin) activated clotting time, additional native blood samples were analyzed on a Sonoclot using glass bead-activated tests. Glass bead-activated clotting time, clot rate, and platelet function were recorded immediately before anesthesia induction and at the end of surgery after heparin reversal but before chest closure. MEASUREMENTS AND MAIN RESULTS: Primary outcome was postoperative blood loss (chest tube drainage at 4, 8, and 12 hours postoperatively). Secondary outcome parameters were transfusion requirements, need for surgical re-exploration, time of mechanical ventilation, length of intensive care unit and hospital stay, and hospital morbidity and mortality. Patients were categorized into "bleeders" and "nonbleeders." Patient characteristics, operations, preoperative standard laboratory parameters, and procedural times were comparable between bleeders and nonbleeders except for sex and age. Bleeders had higher rates of transfusions, surgical re-explorations, and complications. Only glass bead measurements by Sonoclot after heparin reversal before chest closure but not preoperatively were predictive for increased postoperative bleeding. CONCLUSIONS: Sonoclot with its glass bead-activated tests may predict the risk for postoperative bleeding in patients undergoing cardiac surgery at the end of surgery after heparin reversal but before chest closure.


Asunto(s)
Anticoagulantes/uso terapéutico , Coagulación Sanguínea/efectos de los fármacos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Antagonistas de Heparina/uso terapéutico , Heparina/uso terapéutico , Hemorragia Posoperatoria/diagnóstico , Anciano , Anticoagulantes/efectos adversos , Coagulación Sanguínea/fisiología , Pruebas de Coagulación Sanguínea/métodos , Femenino , Heparina/efectos adversos , Antagonistas de Heparina/farmacología , Humanos , Masculino , Persona de Mediana Edad , Hemorragia Posoperatoria/sangre , Hemorragia Posoperatoria/etiología , Valor Predictivo de las Pruebas , Estudios Prospectivos
14.
Curr Opin Anaesthesiol ; 27(1): 28-35, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24304864

RESUMEN

PURPOSE OF REVIEW: Advanced hemodynamic monitoring is indispensable for adequate management of patients undergoing major surgery. This article will summarize minimally invasive hemodynamic monitoring technologies and their potential use in thoracic anesthesia. RECENT FINDINGS: According to their inherent principle, currently available technologies can be classified into four groups: bioimpedance and bioreactance, applied Fick's principle, pulse wave analysis and Doppler. All devices measure stroke volume and cardiac output. Functional hemodynamic variables and volumetric parameters have been integrated in some devices. Two major indications can be identified: the 'hemodynamically unstable' patient and the patient 'at risk' for hemodynamic instability. Although there is evidence for the first indication, pre-emptive hemodynamic therapy or perioperative hemodynamic optimization for the patient 'at risk' is still an issue of ongoing debate. There is a growing body of evidence that this approach can positively influence patients' outcome with less postoperative complications in selected patient groups. SUMMARY: Many different minimally invasive hemodynamic monitoring devices have been developed and clinically introduced in the last years. They offer the advantage of being less invasive and easier to use. However, these techniques have several limitations and data are scarce in patients undergoing thoracic anesthesia, preventing their widespread use so far.


Asunto(s)
Anestesia/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Monitoreo Intraoperatorio/métodos , Procedimientos Quirúrgicos Torácicos/métodos , Gasto Cardíaco/fisiología , Hemodinámica/fisiología , Humanos , Ácido Láctico/sangre , Oxígeno/sangre
15.
Bioengineering (Basel) ; 10(3)2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-36978731

RESUMEN

Interpreting blood gas analysis results can be challenging for the clinician, especially in stressful situations under time pressure. To foster fast and correct interpretation of blood gas results, we developed Visual Blood. This computer-based, multicentre, noninferiority study compared Visual Blood and conventional arterial blood gas (ABG) printouts. We presented six scenarios to anaesthesiologists, once with Visual Blood and once with the conventional ABG printout. The primary outcome was ABG parameter perception. The secondary outcomes included correct clinical diagnoses, perceived diagnostic confidence, and perceived workload. To analyse the results, we used mixed models and matched odds ratios. Analysing 300 within-subject cases, we showed noninferiority of Visual Blood compared to ABG printouts concerning the rate of correctly perceived ABG parameters (rate ratio, 0.96; 95% CI, 0.92-1.00; p = 0.06). Additionally, the study revealed two times higher odds of making the correct clinical diagnosis using Visual Blood (OR, 2.16; 95% CI, 1.42-3.29; p < 0.001) than using ABG printouts. There was no or, respectively, weak evidence for a difference in diagnostic confidence (OR, 0.84; 95% CI, 0.58-1.21; p = 0.34) and perceived workload (Coefficient, 2.44; 95% CI, -0.09-4.98; p = 0.06). This study showed that participants did not perceive the ABG parameters better, but using Visual Blood resulted in more correct clinical diagnoses than using conventional ABG printouts. This suggests that Visual Blood allows for a higher level of situation awareness beyond individual parameters' perception. However, the study also highlighted the limitations of today's virtual reality headsets and Visual Blood.

16.
Diagnostics (Basel) ; 13(21)2023 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-37958287

RESUMEN

Visual Patient Avatar ICU is an innovative approach to patient monitoring, enhancing the user's situation awareness in intensive care settings. It dynamically displays the patient's current vital signs using changes in color, shape, and animation. The technology can also indicate patient-inserted devices, such as arterial lines, central lines, and urinary catheters, along with their insertion locations. We conducted an international, multi-center study using a sequential qualitative-quantitative design to evaluate users' perception of Visual Patient Avatar ICU among physicians and nurses. Twenty-five nurses and twenty-five physicians from the ICU participated in the structured interviews. Forty of them completed the online survey. Overall, ICU professionals expressed a positive outlook on Visual Patient Avatar ICU. They described Visual Patient Avatar ICU as a simple and intuitive tool that improved information retention and facilitated problem identification. However, a subset of participants expressed concerns about potential information overload and a sense of incompleteness due to missing exact numerical values. These findings provide valuable insights into user perceptions of Visual Patient Avatar ICU and encourage further technology development before clinical implementation.

17.
JAMA Netw Open ; 6(11): e2342527, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37938844

RESUMEN

Importance: Nearly 16 million surgical procedures are conducted in North America yearly, and postoperative cardiovascular events are frequent. Guidelines suggest functional capacity or B-type natriuretic peptides (BNP) to guide perioperative management. Data comparing the performance of these approaches are scarce. Objective: To compare the addition of either N-terminal pro-BNP (NT-proBNP) or self-reported functional capacity to clinical scores to estimate the risk of major adverse cardiac events (MACE). Design, Setting, and Participants: This cohort study included patients undergoing inpatient, elective, noncardiac surgery at 25 tertiary care hospitals in Europe between June 2017 and April 2020. Analysis was conducted in January 2023. Eligible patients were either aged 45 years or older with a Revised Cardiac Risk Index (RCRI) of 2 or higher or a National Surgical Quality Improvement Program, Risk Calculator for Myocardial Infarction and Cardiac (NSQIP MICA) above 1%, or they were aged 65 years or older and underwent intermediate or high-risk procedures. Exposures: Preoperative NT-proBNP and the following self-reported measures of functional capacity were the exposures: (1) questionnaire-estimated metabolic equivalents (METs), (2) ability to climb 1 floor, and (3) level of regular physical activity. Main Outcome and Measures: MACE was defined as a composite end point of in-hospital cardiovascular mortality, cardiac arrest, myocardial infarction, stroke, and congestive heart failure requiring transfer to a higher unit of care. Results: A total of 3731 eligible patients undergoing noncardiac surgery were analyzed; 3597 patients had complete data (1258 women [35.0%]; 1463 (40.7%) aged 75 years or older; 86 [2.4%] experienced a MACE). Discrimination of NT-proBNP or functional capacity measures added to clinical scores did not significantly differ (Area under the receiver operating curve: RCRI, age, and 4MET, 0.704; 95% CI, 0.646-0.763; RCRI, age, and 4MET plus floor climbing, 0.702; 95% CI, 0.645-0.760; RCRI, age, and 4MET plus physical activity, 0.724; 95% CI, 0.672-0.775; RCRI, age, and 4MET plus NT-proBNP, 0.736; 95% CI, 0.682-0.790). Benefit analysis favored NT-proBNP at a threshold of 5% or below, ie, if true positives were valued 20 times or more compared with false positives. The findings were similar for NSQIP MICA as baseline clinical scores. Conclusions and relevance: In this cohort study of nearly 3600 patients with elevated cardiovascular risk undergoing noncardiac surgery, there was no conclusive evidence of a difference between a NT-proBNP-based and a self-reported functional capacity-based estimate of MACE risk. Trial Registration: ClinicalTrials.gov Identifier: NCT03016936.


Asunto(s)
Infarto del Miocardio , Preescolar , Femenino , Humanos , Biomarcadores , Estudios de Cohortes , Complicaciones Posoperatorias/epidemiología , Valor Predictivo de las Pruebas , Medición de Riesgo , Autoinforme
18.
J Biol Chem ; 285(7): 4278-90, 2010 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-19996317

RESUMEN

Exogenous or endogenous beta(2)-adrenergic receptor agonists enhance alveolar epithelial fluid transport via a cAMP-dependent mechanism that protects the lungs from alveolar flooding in acute lung injury. However, impaired alveolar fluid clearance is present in most of the patients with acute lung injury and is associated with increased mortality, although the mechanisms responsible for this inhibition of the alveolar epithelial fluid transport are not completely understood. Here, we found that transforming growth factor beta1 (TGF-beta1), a critical mediator of acute lung injury, inhibits beta(2)-adrenergic receptor agonist-stimulated vectorial fluid and Cl(-) transport across primary rat and human alveolar epithelial type II cell monolayers. This inhibition is due to a reduction in the cystic fibrosis transmembrane conductance regulator activity and biosynthesis mediated by a phosphatidylinositol 3-kinase (PI3K)-dependent heterologous desensitization and down-regulation of the beta(2)-adrenergic receptors. Consistent with these in vitro results, inhibition of the PI3K pathway or pretreatment with soluble chimeric TGF-beta type II receptor restored beta(2)-adrenergic receptor agonist-stimulated alveolar epithelial fluid transport in an in vivo model of acute lung injury induced by hemorrhagic shock in rats. The results demonstrate a novel role for TGF-beta1 in impairing the beta- adrenergic agonist-stimulated alveolar fluid clearance in acute lung injury, an effect that could be corrected by using PI3K inhibitors that are safe to use in humans.


Asunto(s)
AMP Cíclico/metabolismo , Regulador de Conductancia de Transmembrana de Fibrosis Quística/metabolismo , Células Epiteliales/efectos de los fármacos , Células Epiteliales/metabolismo , Fosfatidilinositol 3-Quinasas/metabolismo , Alveolos Pulmonares/citología , Factor de Crecimiento Transformador beta1/farmacología , Antagonistas de Receptores Adrenérgicos beta 2 , Animales , Transporte Biológico/efectos de los fármacos , Western Blotting , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Cloruros/metabolismo , Humanos , Masculino , Ratas , Ratas Sprague-Dawley , Receptores Adrenérgicos beta 2/metabolismo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Choque Hemorrágico/metabolismo
19.
Swiss Med Wkly ; 151(33-34)2021 08 20.
Artículo en Inglés | MEDLINE | ID: mdl-34448557

RESUMEN

AIMS OF THE STUDY: The Swiss healthcare system is highly ranked, given its unrestricted access to specialised care and short waiting lists for surgery. However, the need for anaesthetic and surgical care is escalating owing to the increasing size and ageing of the Swiss population. In addition, to address the persistent and recurrent SARS-CoV-2 pandemic crisis, the speciality of anaesthesia is under tremendous pressure to maintain an effective workforce in order to address population needs. The current number, characteristics and future evolution of the physician anaesthesia workforce in Switzerland are currently unknown. The purpose of this study was to assess the size and professional and sociodemographic characteristics of the current anaesthesia workforce in Switzerland and to forecast its development up to 2034. METHODS: We performed a cross-sectional study using a 150-item questionnaire prepared by the National Anaesthesia Workforce Study Group (NAWOS). We included all physicians (trainees and certified) practising anaesthesia in Switzerland. We collected demographic and professional information, such as the current position, hospital characteristics, workload, number of shifts and future life plans. We built a computer-based Markov model with Monte Carlo simulations to project both supply and demand for physician anaesthesia provider positions. RESULTS: Of the 2661 distributed questionnaires, 1985 (74.2%) were completed and returned. We found that the average age of anaesthesiologists practising in Switzerland was 45.2 years, with 44.3% of them being women and 76.9% holding a Swiss specialist title. Only 59.6% of respondents worked full time. The forecasting model showed a steady increase in the number of anaesthesiologists retiring by 2034, with 27% of full-time equivalent jobs being lost in the next 8 years. Even if existing full-time equivalent training positions are all filled, a gradual deficit of anaesthesiologists is to be expected after 2022, and the deficit should culminate in 2034 with a deficit ratio of 0.87. CONCLUSIONS: Due to the upcoming high retirement rate of anaesthesiologists, Switzerland is likely to face a shortage of anaesthesiologists in the near future. To compensate for the shortage, the country will likely increase its reliance on medical staff trained abroad. Southern and eastern cantons of Switzerland are particularly at risk, given that they already heavily rely on foreign anaesthesia workforce. This reliance should be considered a national priority because anaesthesiologists are heavily involved in both the treatment of patients with respiratory complications of SARS-CoV2 infection and the care of surgical patients, the number of which is expected to rise steadily in upcoming years.


Asunto(s)
Anestesia , COVID-19 , Médicos , Estudios Transversales , Femenino , Humanos , ARN Viral , SARS-CoV-2 , Suiza , Recursos Humanos
20.
Am J Respir Cell Mol Biol ; 43(1): 99-108, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19717814

RESUMEN

Hypoxia and epithelial stretch that are commonly observed in patients with acute lung injury have been shown to promote the release of serotonin (5-hydroxytryptamine, 5-HT) in vitro. However, whether 5-HT contributes to the decrease of alveolar epithelial fluid transport, which is a hallmark of lung injury, is unknown. Thus, we investigated the effect of 5-HT on ion and fluid transport across the alveolar epithelium. 5-HT caused a dose-dependent inhibition of the amiloride-sensitive current across primary rat and human alveolar epithelial type II cell monolayers, but did not affect Na(+)/K(+) ATPase function. Furthermore, we found that the 5-HT induced inhibition of ion transport across the lung epithelium was receptor independent, as it was not prevented by the blockade of 5-HT2R (5-HT receptor 2), 5-HT3R (5-HT receptor 3), or by pretreatment with an intracellular calcium-chelating agent, BAPTA-AM (1,2-bis(o-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid tetra(acetoxymethyl) ester). In addition, the stimulation of 5-HT1R (5-HT receptor 1), 5-HT2R (5-HT receptor 2), 5-HT4R (5-HT receptor 4), and 5-HT7R (5-HT receptor 7) failed to reproduce the 5-HT effect on amiloride-sensitive sodium transport. We ascertained that 5-HT directly inhibited the function of rat alphabetagamma epithelial sodium channel (ENaC), as determined by heterologous expression of rat ENaC in Xenopus oocytes that do not express endogenous ENaC nor 5-HT receptors (5-HTR). Exposure of mice to hypoxia for 1 hour induced a 30% increase of 5-HT secretion into the distal airways of mice. Finally, the intratracheal instillation of 5-HT inhibited the amiloride-sensitive fraction of alveolar fluid clearance in mice. Together, these results indicate that 5-HT inhibits the amiloride-sensitive fraction of the alveolar epithelial fluid transport via a direct interaction with ENaC, and thus can be an endogenous inhibitor of this ion channel.


Asunto(s)
Canales Epiteliales de Sodio/metabolismo , Alveolos Pulmonares/metabolismo , Serotonina/metabolismo , Amilorida/farmacología , Animales , Línea Celular , Línea Celular Tumoral , Epitelio/patología , Humanos , Hipoxia , Iones/metabolismo , Pulmón/metabolismo , Ratones , Ratones Endogámicos C57BL , Oocitos/metabolismo , Técnicas de Placa-Clamp , Ratas , Tráquea/metabolismo , Xenopus
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA